Minmax MSKW2021 Dc/dc converter 5w, smd-package Datasheet

MSKW2000 SERIES
DC/DC CONVERTER 5W, SMD-Package
FEATURES
►Industrial SMD Package
►Wide 2:1 Input Voltage Range
►Fully Regulated Output Voltage
►I/O Isolation 1500 VDC
►Operating Ambient Temp. Range -40°C to +85°C
►Overload and Short Circuit Protection
►Remote On/Off Control
►Conducted EMI meets EN55022 Class A & FCC Level A
►Qualified for Lead-free Reflow Solder Process
According to IPC/JEDEC J-STD-020D.1
►Tape & Reel Package Available
►UL/cUL/IEC/EN 60950-1 Safety Approval
PRODUCT OVERVIEW
The MINMAX MSKW2000 series is a range of isolated 5W DC/DC converter modules featuring fully regulated output voltages and wide 2:1 input voltage
ranges.
These products are in a low profile SMD package with dimensions of 33.4 x 20.8 x 9.8 mm. All models are qualified for lead free reflow solder processes
according IPC J-STD-020D.1. An excellent efficiency allows an operating temperature range of–40° to +85°C (with derating).
Typical applications for these converters are battery operated equipment and instrumentation, communication and general industrial electronics.
Model Selection Guide
Model
Number
Input
Voltage
(Range)
Output
Voltage
VDC
VDC
Output Current
Input Current
Max.
Min.
@Max. Load
@No Load
Reflected
Ripple
Current
mA
mA
mA(typ.)
mA(typ.)
mA(typ.)
MSKW2021
3.3
1200
120
434
MSKW2022
5
1000
100
521
MSKW2023
12
417
41.7
502
15
333
33.3
502
MSKW2024
MSKW2025
12
(9 ~ 18)
Max. capacitive
Load
μF
Efficiency
(typ.)
@Max. Load
%
76
680
45
25
80
83
83
±5
±500
±50
521
MSKW2026
±12
±208
±20.8
501
MSKW2027
±15
±167
±16.7
503
MSKW2031
3.3
1200
120
212
78
MSKW2032
5
1000
100
254
82
12
417
41.7
245
MSKW2033
MSKW2034
24
(18 ~ 36)
80
100#
83
83
680
85
15
333
33.3
245
±5
±500
±50
254
MSKW2036
±12
±208
±20.8
245
MSKW2037
±15
±167
±16.7
246
85
MSKW2041
3.3
1200
120
106
78
MSKW2042
5
1000
100
127
MSKW2043
12
417
41.7
123
MSKW2035
MSKW2044
48
(36 ~ 75)
15
333
33.3
122
±5
±500
±50
127
MSKW2046
±12
±208
±20.8
122
MSKW2047
±15
±167
±16.7
123
MSKW2045
15
85
15
82
100#
680
6
10
2016/07/26
Tel:886-6-2923150
REV : 9 Page 1 of 5
82
85
85
82
100#
85
85
# For each output
E-mail:[email protected]
85
MSKW2000 SERIES
DC/DC CONVERTER 5W, SMD-Package
Input Specifications
Parameter
Input Surge Voltage (1 sec. max.)
Start-Up Threshold Voltage
Under Voltage Shutdown
Model
Min.
Typ.
Max.
12V Input Models
-0.7
---
25
24V Input Models
-0.7
---
50
48V Input Models
-0.7
---
100
12V Input Models
7.5
8
9
24V Input Models
14
16
18
48V Input Models
30
33
36
12V Input Models
6.5
7
8
24V Input Models
13
15
17
48V Input Models
28
31
34
---
1000
3000
Short Circuit Input Power
Input Filter
All Models
Unit
VDC
mW
Internal Pi Type
Conducted EMI
Compliance to EN 55022,class A and FCC part 15,class A
Remote On/Off Control
Parameter
Conditions
Converter On
Min.
Typ.
Max.
Unit
2.5V ~ 5.5V or Open Circuit
Converter Off
-0.7V ~ 0.8V
Control Input Current (on)
Vctrl = Min. to Max.
---
---
-200
μA
Control Input Current (off)
Vctrl = Min. to Max.
---
---
-300
μA
---
---
10
mA
Min.
Typ.
Max.
Unit
---
---
±1.0
%Vnom.
Dual Output, Balanced Loads
---
±0.5
±2.0
%
Vin=Min. to Max.
---
±0.1
±0.3
%
Load Regulation
Io=20% to 100%
---
±0.3
±1.0
%
Ripple & Noise
0-20 MHz Bandwidth
---
---
85
mV P-P
---
250
500
μsec
---
±2
±6
%
---
±0.01
±0.02
%/℃
115
140
165
%
Control Common
Referenced to Negative Input
Standby Input Current
Output Specifications
Parameter
Conditions
Output Voltage Setting Accuracy
Output Voltage Balance
Line Regulation
Transient Recovery Time
25% Load Step Change
Transient Response Deviation
Temperature Coefficient
Over Load Protection
Foldback
Short Circuit Protection
Continuous, Automatic Recovery
General Specifications
Parameter
I/O Isolation Voltage
Conditions
Min.
Typ.
Max.
Unit
60 Seconds
1500
---
---
VDC
1 Seconds
1800
---
---
VDC
I/O Isolation Resistance
500 VDC
1000
---
---
MΩ
I/O Isolation Capacitance
100KHz, 1V
---
650
750
pF
200
260
350
KHz
Switching Frequency
MTBF (calculated)
MIL-HDBK-217F@25℃, Ground Benign
Moisture Sensitivity Level (MSL)
IPC/JEDEC J-STD-020D.1
Safety Approvals
Level 2
UL/cUL 60950-1 recognition(CSA certificate), IEC/EN 60950-1(CB-report)
E-mail:[email protected]
2016/07/26
1,000,000
Tel:886-6-2923150
REV : 9 Page 2 of 5
Hours
MSKW2000 SERIES
DC/DC CONVERTER 5W, SMD-Package
Environmental Specifications
Parameter
Operating Ambient Temperature Range (See Power Derating Curve)
Case Temperature
Storage Temperature Range
Humidity (non condensing)
Cooling
Lead-free Reflow Solder Process
Conditions
Natural Convection
Min.
Max.
-40
+85
--+90
-50
+125
--95
Natural Convection
IPC/JEDEC J-STD-020D.1
Unit
℃
℃
℃
% rel. H
Power Derating Curve
100
Natural
convection
20LFM
Output Power (%)
80
400LFM
60
40
20
0
~
-40
0
20
40
60
80
100 110
Ambient Temperature C
Notes
1
2
3
4
5
6
7
Specifications typical at Ta=+25℃, resistive load, nominal input voltage and rated output current unless otherwise noted.
Transient recovery time is measured to within 1% error band for a step change in output load of 75% to 100%.
These power converters require a minimum output loading to maintain specified regulation, operation under no-load conditions will not damage these
modules; however they may not meet all specifications listed.
We recommend to protect the converter by a slow blow fuse in the input supply line.
Other input and output voltage may be available, please contact factory.
That “natural convection” is about 20LFM but is not equal to still air (0 LFM).
Specifications are subject to change without notice.
Package Specifications
Mechanical Dimensions
Connecting Pin Patterns
27.94 [1.10]
33.4 [1.31]
9 10 11 12
20.8 [0.82]
1 2 3
23.9 [0.94]
16 15 14 13
20.8 [0.82]
24 23 22
27.0 [1.06]
15.24 [0.60]
7.62
[0.3]
25.6 [1.01]
15.24 [0.6]
5.08
[0.2]
22.6 [0.89]
2.76
[0.11]
10.2 0.5
[0.4 0.02]
5
►All dimensions in mm
0.15 S
►Tolerance: X.X±0.25
2016/07/26
Tel:886-6-2923150
REV : 9 Page 3 of 5
(inches)
(X.XX±0.01)
X.XX±0.13 ( X.XXX±0.005)
►Pins ±0.05
E-mail:[email protected]
1.7 [0.07]
S SEATING
PLANE
0~
0.4
[0.02]
9.8 [0.39]
2.54 [0.10]
(±0.002)
3.1
[0.12]
1.50 [0.06]
MSKW2000 SERIES
DC/DC CONVERTER 5W, SMD-Package
Pin Connections
Physical Characteristics
Pin
Single Output
Dual Output
1
Remote On/Off
Remote On/Off
2
-Vin
-Vin
3
-Vin
-Vin
9
NC
Common
10
NC
NC
11
NC
-Vout
12
NC
NC
13
NC
NC
14
+Vout
+Vout
15
NC
NC
16
-Vout
Common
22
+Vin
+Vin
23
+Vin
+Vin
24
NC
NC
NC : No Connection
E-mail:[email protected]
2016/07/26
Tel:886-6-2923150
REV : 9 Page 4 of 5
Case Size
:
33.4x20.8x10.2mm (1.31x0.82x0.4 inches)
Case Material
:
Non-Conductive Black Plastic (flammability to UL 94V-0 rated)
Pin Material
:
Phosphor Bronze
Weight
:
14g
MSKW2000 SERIES
DC/DC CONVERTER 5W, SMD-Package
Test Setup
Input Reflected-Ripple Current Test Setup
Input reflected-ripple current is measured with a inductor Lin (4.7μH) and Cin (220μF, ESR < 1.0Ω at 100 KHz) to simulate source impedance.
Capacitor Cin, offsets possible battery impedance. Current ripple is measured at the input terminals of the module, measurement bandwidth is 0-500 KHz.
To Oscilloscope
+
+
+Vin
Lin
Current
Probe
Cin
Battery
+Out
DC / DC
Converter
-Vin
Load
-Out
Peak-to-Peak Output Noise Measurement Test
Use a Cout 0.47μF ceramic capacitor. Scope measurement should be made by using a BNC socket, measurement bandwidth is 0-20 MHz. Position the load
between 50 mm and 75 mm from the DC/DC Converter.
+Vin
+Out
Copper Strip
Single Output
DC / DC
Converter
-Vin
Cout
-Out
Scope
Resistive
Load
Copper Strip
+Vin
+Out
Copper Strip
Dual Output
DC / DC
Converter
Com.
Copper Strip
-Vin
-Out
Scope
Cout
Resistive
Load
Cout
Scope
Copper Strip
Technical Notes
Remote On/Off
Positive logic remote on/off turns the module on during a logic high voltage on the remote on/off pin, and off during a logic low. To turn the power module on and off,
the user must supply a switch to control the voltage between the on/off terminal and the -Vin terminal. The switch can be an open collector or equivalent.
A logic low is -0.7V to 0.8V. A logic high is 2.5V to 5.5V.
The maximum sink current of the switch at on/off terminal during a logic low is 300μA. The maximum sink current of the switch at on/off terminal = 2.5 to 5.5V is
200μA or open.
Overcurrent Protection
To provide protection in a fault (output overload) condition, the unit is equipped with internal current limiting circuitry and can endure current limiting for an unlimited
duration. At the point of current-limit inception, the unit shifts from voltage control to current control. The unit operates normally once the output current is brought back
into its specified range.
Input Source Impedance
The power module should be connected to a low ac-impedance input source. Highly inductive source impedances can affect the stability of the power module.
In applications where power is supplied over long lines and output loading is high, it may be necessary to use a capacitor at the input to ensure startup.
Capacitor mounted close to the power module helps ensure stability of the unit, it is recommended to use a good quality low Equivalent Series Resistance (ESR <
1.0Ω at 100 KHz) capacitor of a 3.3μF for the 12V input devices and a 2.2μF for the 24V and 48V devices.
+
DC Power
Source
+Vin
+
+Out
DC / DC
Converter
Load
Cin
-
-Vin
-Out
Output Ripple Reduction
A good quality low ESR capacitor placed as close as practicable across the load will give the best ripple and noise performance. To reduce output ripple, it is
recommended to use 3.3μF capacitors at the output.
+
+Vin
DC Power
Source
-
+Out
Single Output
DC / DC
Converter
-Vin
+
Cout
Load
-Out
Dual Output
Com.
DC / DC
Converter
DC Power
Source
-
+Out
+Vin
-Vin
-Out
Cout
Load
Load
Cout
Maximum Capacitive Load
The MSKW2000 series has limitation of maximum connected capacitance at the output. The power module may be operated in current limiting mode during start-up,
affecting the ramp-up and the startup time. For optimum performance we recommend 100μF maximum capacitive load for dual outputs and 680μF capacitive load for
single outputs. The maximum capacitance can be found in the data sheet.
Thermal Considerations
Many conditions affect the thermal performance of the power module, such as orientation, airflow over the module and board spacing. To avoid exceeding the
maximum temperature rating of the components inside the power module, the case temperature must be kept below 90℃. The derating curves are determined from
measurements obtained in a test setup.
Position of air velocity
probe and thermocouple
15mm / 0.6in
50mm / 2in
Air Flow
DUT
18, Sin Sin Road, An-Ping Industrial District, Tainan 702, Taiwan
Tel: 886-6-2923150 Fax: 886-6-2923149 E-mail: [email protected]
Minmax Technology Co., Ltd.
2016/07/26
REV : 9
Page 5 of 5