RoHS Compliant Small Form Factor Pluggable Transceiver for Fiber Channel with Digital Diagnostic Monitoring Function FEATURES z Compliant with SFP Transceiver SFF-8472 MSA specification z LCP-2125B4QDR compliant with the 2.125GBd Fiber Channel 200-SM-LC-L FC-PI Rev.13 z Compliant with Specifications for IEEE 802.3z/Gigabit Ethernet z EEPROM with Serial ID and Digital Diagnostic Functionality z Laser Class 1 Product which comply with the requirements of IEC 60825-1 and IEC 60825-2 z Duplex LC Connector interface Description Applications The LCP-2125 series are hot pluggable 3.3V Small-Form-Factor transceiver modules designed z Switch to Switch interface expressly for high-speed communication z Switched backplane applications applications that require rates up to 2.125Gb/s. The transceiver is data rate transparent, which z File server interface means it can support 2x Fiber channel as well as Performance GbE (1.25Gb/s) and 1x Fiber channel (1.062Gb/s). The LCP-2125 series are designed to be z LCP-2125B4QDR Data Link up to 10km in compliant with SFF-8472 SFP Multi-source 9/125μm Single Mode Fiber Agreement (MSA) with digital monitoring functions: Temperature, VCC, TX optical power, TX laser bias current, and RX received optical power. The post-amplifier of the LCP-2125 series also includes a Loss of Signal (LOS) circuit that provides a TTL logic-high output when the received optical level is bellow a preset LOS Assert threshold. 1 DELTA ELECTRONICS, INC. Nov., 2006 Rev. 1D www.deltaww.com Absolute Maximum Ratings Parameter Storage Temperature Supply Voltage Symbol Ts VCC Min. -40 0 Typ. Max. 85 5 Unit ºC V Note Symbol TC VCC Min. -5 3.135 Typ. Max. 70 3.465 Unit ºC V Note 1 Symbol ICCT Min. Typ. Max. 300 Unit mA Note VDT VDISH VDISL 0.5 2 0 4.7 2 0 2.4 VCC+0.3 0.8 10 VCC+0.3 0.8 V V V kΩ V V 1 0.35 4.7 2 0 2.0 10 VCC+0.3 0.8 2.5 V kΩ V V nsec Recommended Operating Conditions Parameter Case Operating Temperature Supply Voltage Note 1: See order information Electrical Characteristics (VCC=3.3V ± 5%) Parameter Total Supply Current Transmitter Transmitter Differential Input Voltage Transmitter Disable Input-High Transmitter Disable Input-Low Transmitter Fault Pull up Resistor Transmitter Fault Output-High Transmitter Fault Output-Low Receiver Receiver Differential Output Voltage Receiver LOS Load LOS Output Voltage-High LOS Output Voltage-Low Output Data Rise/Fall Time RTX_FAULT VTXFH VTXFL VDR RRXLOS VLOSH VLOSL tr / t f 2 3 2 4 Notes: 1. Internally AC coupled and terminated to 100Ohm differential load. 2. Pull up to VCC on host Board. 3. Internally AC coupled, but requires a 100Ohm differential termination at or internal to Serializer/ Deserializer. 4. These are 20%~80% values. 2 DELTA ELECTRONICS, INC. Nov., 2006 Rev. 1D www.deltaww.com Optical Characteristics (VCC=3.3V ± 5%, Data Rate=2.125 Gb/sec, PRBS=27-1 NRZ) Parameter Transmitter Output Optical Power (Avg.) Optical Extinction Ratio Center Wavelength Spectral Width (RMS) Optical Rise/Fall Time Output Eye Receiver Sensitivity (Avg.) Input Optical Wavelength LOS-Deasserted (Avg.) LOS-Asserted (Avg.) LOS-Hysteresis Overload Symbol Min. PO -10 9 1270 Typ. Max. Unit Note dBm dB λC 1310 1360 nm σ 4 nm 160 psec 1 tr/ tf Complies with the ANSI FC-PI Rev. 13 specification, and is class 1 laser eye safety PIN λ PA PD PA-PD PO -3 -17 1310 -17 -30 0.5 -3 dBm nm dBm dBm dB dBm 2 Notes: 1. These are 20%~80% values 2. The sensitivity is provided at a BER of 1×10-10 or better with an input signal consisting of 2.125Gb/s, 27-1 PRBS and ER=9dB. Mask of the eye diagram for the optical transmit signal 3 DELTA ELECTRONICS, INC. Nov., 2006 Rev. 1D www.deltaww.com SFP Transceiver Electrical Pad Layout Pin Function Definitions Pin Num. 1 2 Name VeeT TX Fault 3 TX Disable 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 MOD-DEF2 MOD-DEF1 MOD-DEF0 Rate Select LOS VeeR VeeR VeeR RDRD+ VeeR VccR VccT VeeT TD+ TDVeeT Function Transmitter Ground Transmitter Fault Indication Plug Seq. 1 3 Transmitter Disable 3 Module Definition 2 Module Definition 1 Module Definition 0 Not Connect Loss of Signal Receiver Ground Receiver Ground Receiver Ground Inv. Received Data Out Received Data Out Receiver Ground Receiver Power Transmitter Power Transmitter Ground Transmit Data In Inv. Transmit Data In Transmitter Ground 3 3 3 3 3 1 1 1 3 3 1 2 2 1 3 3 1 Notes Note 1 Note 2 Module disables on high or open Note 3, 2 wire serial ID interface Note 3, 2 wire serial ID interface Note 3, Grounded in Module Function not available Note 4 Note 5 Note 5 Note 5 Note 6 Note 7 Note 5 3.3 ± 5%, Note 7 3.3 ± 5%, Note 7 Note 5 Note 8 Note 8 Note 5 Plug Seq.: Pin engagement sequence during hot plugging. 4 DELTA ELECTRONICS, INC. Nov., 2006 Rev. 1D www.deltaww.com Notes: 1) TX Fault is an open collector/drain output, which should be pulled up with a 4.7K – 10KΩ resistor on the host board. Pull up voltage between 2.0V and VccT, R+0.3V. When high, output indicates a laser fault of some kind. Low indicates normal operation. In the low state, the output will be pulled to < 0.8V. 2) TX disable is an input that is used to shut down the transmitter optical output. It is pulled up within the module with a 4.7 – 10 K Ω resistor. Its states are: 3) Low (0 – 0.8V): Transmitter on (>0.8, < 2.0V): Undefined High (2.0 – 3.465V): Transmitter Disabled Open: Transmitter Disabled Mod-Def 0,1,2. These are the module definition pins. They should be pulled up with a 4.7K – 10KΩresistor on the host board. The pull-up voltage shall be VccT or VccR (see Section IV for further details). Mod-Def 0 is grounded by the module to indicate that the module is present Mod-Def 1 is the clock line of two wire serial interface for serial ID Mod-Def 2 is the data line of two wire serial interface for serial ID 4) LOS (Loss of Signal) is an open collector/drain output, which should be pulled up with a 4.7K – 10KΩ resistor. Pull up voltage between 2.0V and VccT, R+0.3V. When high, this output indicates the received optical power is below the worst-case receiver sensitivity (as defined by the standard in use). Low indicates normal operation. In the low state, the output will be pulled to < 0.8V. 5) VeeR and VeeT may be internally connected within the SFP module. 6) RD-/+: These are the differential receiver outputs. They are AC coupled 100Ω differential lines which should be terminated with 100Ω (differential) at the user SERDES. The AC coupling is done inside the module and is thus not required on the host board. The voltage swing on these lines will be between 370 and 2000 mV differential (185 – 1000 mV single ended) when properly terminated. 7) VccR and VccT are the receiver and transmitter power supplies. They are defined as 3.3V ±5% at the SFP connector pin. Maximum supply current is 300mA. Recommended host board power supply filtering is shown below. Inductors with DC resistance of less than 1=should be used in order to maintain the required voltage at the SFP input pin with 3.3V supply voltage. When the recommended supply-filtering network is used, hot plugging of the SFP transceiver module will result in an inrush current of no more than 30mA greater than the steady state value. VccR and VccT may be internally connected within the SFP transceiver module. 8) TD-/+: These are the differential transmitter inputs. They are AC-coupled, differential lines with 100Ω differential termination inside the module. The AC coupling is done inside the module and is thus not required on the host board. The inputs will accept differential swings of 500 – 2400 mV (250 – 1200 mV single-ended), though it is recommended that values between 500 and 1200 mV differential (250 – 600 mV single-ended) be used for best EMI performance. 5 DELTA ELECTRONICS, INC. Nov., 2006 Rev. 1D www.deltaww.com Recommend Circuit Schematic VCC 1uH 3.3V DELTA SFP Module Protocol Vcc 1uH RES1 10uF 0.1uF 0.1uF VccT 10k Ohms Tx_Disable Tx_Disable Tx_Fault Tx_Fault TD + 0.01uF 100 Ohms Laser Driver Laser Diode TD - Protocol IC 0.01uF VeeT SerDes IC VccR RES1 10uF 0.1uF RD + 0.01uF RD - 0.01uF 100 Ohms* Preamp & Quantizer Photo Diode Rx_LOS Rx_LOS 3.3V VeeR RES1 RES1 RES1 PLD / PAL Mod_def 2 EEPROM Mod_def 1 Mod_def 0 RES1 = 4.7k to 10k Ohms * Depands on SerDes IC used 6 DELTA ELECTRONICS, INC. Nov., 2006 Rev. 1D www.deltaww.com Package Outline Drawing 7 DELTA ELECTRONICS, INC. Nov., 2006 Rev. 1D www.deltaww.com SFP timing parameters for SFP management Parameter TX_DISABLE Assert time TX_DISABLE Negate time Time to initialize, including reset of TX_FAULT TX Fault Assert Time TX_DISABLE to reset LOS Assert Time LOS Deassert Time Serial ID Clock Rate Symbol t_off t_on Min. t_init t_fault t_rest t_loss_on t_loss_off f_serial_clock Max. 10 1 Unit μsec msec Note 1 2 300 msec 3 100 μsec μsec μsec μsec kHz 4 5 6 7 10 100 100 100 Notes: 1) Time from rising edge of TX_DISABLE to when the optical output falls below 10% of nominal. 2) Time from falling edge of TX_DISABLE to when the modulated optical output rises above 90% of nominal. 3) From power on or negation of TX_Fault using TX Disable. 4) Time from fault to TX fault on. 5) 6) Time TX Disable must be held high to reset TX_Fault Time from LOS state to Rx LOS assert 7) Time from non-LOS state to Rx LOS deassert 8 DELTA ELECTRONICS, INC. Nov., 2006 Rev. 1D www.deltaww.com Enhanced Digital Diagnostic Interface The memory map in the following describes an extension to the memory map defined in SFP MSA. The enhanced interface uses the two wire serial bus address 1010001X(A2h) to provide diagnostic information about the module’s present operating conditions. 2 wire address 1010000 X (A0h) 2 wire address 1010001 X (A2h) 0 0 Alarm and Warning Thresholds (56 bytes) Serial ID Defined by SFP MSA (96 bytes) 55 56 Cal Constants (40 bytes) 95 96 95 96 Real Time Diagnostic Interface (24 bytes) Vender Specific (32 bytes) 119 120 Vender Specific 127 127 128 128 User Writable EEPROM (120 bytes) Reserved in SFP MSA (128 bytes) 247 248 255 255 Vender Specific (8 bytes) Digital Diagnostic Memory Map Specific Data Field Descriptions 9 DELTA ELECTRONICS, INC. Nov., 2006 Rev. 1D www.deltaww.com EEPROM Serial ID Memory Contents (2-Wire Address A0h) Address 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 Hex 03 04 07 00 00 00 xx xx xx xx xx 01 15 00 xx xx 00 00 00 00 44 45 4C 54 41 20 20 20 20 20 20 20 20 20 20 20 00 00 00 00 PN PN PN ASCII Note 1 Note 2 Note 3 D E L T A Note4 Address 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 Hex PN PN PN PN PN PN PN PN PN PN PN PN PN 30 30 30 0A CW CW 00 CS1 00 1A 05 05 SN SN SN SN SN SN SN SN SN SN SN SN SN SN SN SN DC DC ASCII Note 5 Note 5 Note 6 Note 7 Note 8 Address 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 Hex DC DC DC DC DC DC 68 B0 02 CS2 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 ASCII Note 9 Note 10 Notes: 1) Byte 3~10: Code for electronic compatibility or optical compatibility. 2) Byte 14:Transmission distance in km 3) Byte 15: Transmission distance in 100m, distance >25.5km: FFh 4) Byte 40-55: Delta part number 5) Byte 60-61: The center wavelength of transmitter 6) Byte 63: Check sum of bytes 0-62 7) Byte 68-83: Serial number 10 DELTA ELECTRONICS, INC. Nov., 2006 Rev. 1D www.deltaww.com 8) Byte 84-91: Date code 9) Byte 95: Check sum of bytes 64-94 10) Byte 128 to 255 had been set hex 00 Digital Diagnostic Monitoring Interface Alarm and Warning Thresholds (2-Wire Address A2h) Address # Bytes 00-01 02-03 04-05 06-07 08-09 10-11 12-13 14-15 16-17 18-19 20-21 22-23 24-25 26-27 28-29 30-31 32-33 34-35 36-37 38-39 40-45 56-91 92-94 95 96-97 98-99 100-101 102-103 104-105 106-109 110 111 112-119 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 16 36 3 1 2 2 2 2 2 4 1 1 8 Name Temp High Alarm Temp Low Alarm Temp High Warning Temp Low Warning Voltage High Alarm Voltage Low Alarm Voltage High Warning Voltage Low Warning Bias High Alarm Bias Low Alarm Bias High Warning Bias Low Warning TX Power High Alarm TX Power Low Alarm TX Power High Warning TX Power Low Warning RX Power High Alarm RX Power Low Alarm RX Power High Warning RX Power Low Warning Reversed External Calibration Constants Reversed Checksum Real Time Temperature Real Time Supply Voltage Real Time Tx Bias Current Real Time Tx Optical Power Real Time Rx Received Power Reserved Optional Status/ Control Bits Reserved Optional Set of Alarm and Warning Value (Dec.) Unit Note TC (MAX.)+15 TC (MIN.) TC (MAX.)+10 TC (MIN.)+10 Vcc+5% Vcc-5% Vcc+3% Vcc-3% IOP*2+20 IOP-20 IOP *2+10 IOP -10 P+3 P-3 P+2 P-2 P0+3 PS-2 P0+2 PS ℃ 1 Volt mA 2 dBm 3 dBm 4 5 6 7 Notes: 1) TC: Case Operating temperature 2) IOP: Operating current at room temperature. The min. setting current is 0 mA. 3) P: Operating optical power of transmitter at room temperature. 4) P0: Overload optical power of receiver 11 DELTA ELECTRONICS, INC. Nov., 2006 Rev. 1D www.deltaww.com PS: Sensitivity optical power of receiver 5) Byte 95 contains the low order 8bits of sum of bytes 0-94 6) State/ Control Bits Byte 110 110 110 110 110 110 110 110 Bit 7 6 5 4 3 2 1 0 Name Tx Disable State Soft Tx Disable Reserved Rate Select tate Soft Rate Select Tx Fault LOS Data_Ready_Bar Description Digital state of the Tx disable input pin Read/ Write bit that allow software disable of laser NA NA Digital state of the Tx fault output pin Digital state of the LOS output pin. NA 7) Optional Set of Alarm and Warning Byte 112 112 112 112 112 112 112 112 113 113 113 116 116 116 116 116 116 116 116 117 117 117 Bit 7 6 5 4 3 2 1 0 7 6 5-0 7 6 5 4 3 2 1 0 7 6 5-0 Name Temp High Alarm Temp Low Alarm Vcc High Alarm Vcc Low Alarm Tx Bias High Alarm Tx Bias Low Alarm Tx Power High Alarm Tx Power Low Alarm Rx Power High Alarm Rx Power Low Alarm Reserved Temp High Warning Temp Low Warning Vcc High Warning Vcc Low Warning Tx Bias High Warning Tx Bias Low Warning Tx Power High Warning Tx Power Low Warning Rx Power High Warning Rx Power Low Warning Reserved Description Set when internal temperature exceeds high alarm level Set when internal temperature is below low alarm level Set when internal supply voltage exceeds high alarm level Set when internal supply voltage is below low alarm level Set when Tx Bias current exceeds high alarm level Set when Tx Bias current is below low alarm level Set when Tx output power exceeds high alarm level Set when Tx output power is below low alarm level Set when received power exceeds high alarm level Set when received power is below low alarm level Set when internal temperature exceeds high warning level Set when internal temperature is below low warning level Set when internal supply voltage exceeds high warning level Set when internal supply voltage is below low warning level Set when Tx Bias current exceeds high warning level Set when Tx Bias current is below low warning level Set when Tx output power exceeds high warning level Set when Tx output power is below low warning level Set when received power exceeds high warning level Set when received power is below low warning level Digital Diagnostic Monitor Accuracy Parameter Transceiver Temperature Power Supply Voltage TX Bias Current TX Optical Power RX Optical Power Typical Value Note ± 3℃ ± 3% ± 10% ± 1.5dB ± 3dB 1 2 Notes: 12 DELTA ELECTRONICS, INC. Nov., 2006 Rev. 1D www.deltaww.com 1) Temperature is measured internal to the transceiver. 2) Voltage is measured internal to the transceiver. Regulatory Compliance Test Item Reference (#1) FCC Class B Electromagnetic Interference EN 55022 Class B EMC CISPR 22 (#2) Immunity: Qty’ 5 EN 61000-4-3 Radio Frequency Electromagnetic Field IEC 1000-4-3 (#3) Immunity: EN 61000-4-2 Electrostatic Discharge to the Duplex SC Receptacle IEC 1000-4-2 Evaluation 5 (1) Satisfied with electrical characteristics of product spec. 5 (2) No physical damage IEC 801.2 (#4) Electrostatic Discharge to MIL-STD-883C the Electrical Pins Method 3015.4 EIAJ#1988.3.2B 5 Version 2, Machine model 13 DELTA ELECTRONICS, INC. Nov., 2006 Rev. 1D www.deltaww.com Ordering information for SFP modules LCP-2125X1X2X3X4X5X6 X1: Fiber X4: Digital Diagnostic Function B: Single-mode 1310nm D: DDM series, with digital diagnostic function X2: Power Supply Voltage and SD Level X5: Housing Type 4: 3.3V, TTL SD Level R: RoHS Compliant X3: Distance X6: Temperature Q: 10km Blank: -5 to +70 degree C H: -10 to +85 degree C T: -40 to +85 degree C 14 DELTA ELECTRONICS, INC. Nov., 2006 Rev. 1D www.deltaww.com