Dallas DS1306EN+TR Serial alarm real-time clock Datasheet

DS1306
Serial Alarm Real-Time Clock
www.maxim-ic.com
FEATURES
§
§
§
§
§
§
§
§
§
§
§
§
Real-Time Clock (RTC) Counts Seconds,
Minutes, Hours, Date of the Month, Month,
Day of the Week, and Year with Leap-Year
Compensation Valid Up to 2100
96-Byte, Battery-Backed NV RAM for Data
Storage
Two Time-of-Day Alarms, Programmable on
Combination of Seconds, Minutes, Hours,
and Day of the Week
1Hz and 32.768kHz Clock Outputs
Supports Motorola SPI™ (Serial Peripheral
Interface) Modes 1 and 3 or Standard 3-Wire
Interface
Burst Mode for Reading/Writing Successive
Addresses in Clock/RAM
Dual-Power Supply Pins for Primary and
Backup Power Supplies
Optional Trickle Charge Output to Backup
Supply
2.0V to 5.5V Operation
Optional Industrial Temperature Range:
-40°C to +85°C
Available in Space-Efficient, 20-Pin TSSOP
Package
Underwriters Laboratory (UL) Recognized
PIN CONFIGURATIONS
1
2
3
4
5
6
7
8
9
10
VCC2
VBAT
X1
N.C.
X2
N.C.
INT0
INT1
1Hz
GND
VCC1
N.C.
32kHz
VCCIF
SDO
SDI
SCLK
N.C.
CE
SERMODE
20
19
18
17
16
15
14
13
12
11
TSSOP (4.4mm)
1
16
VCC1
VBAT
2
15
32kHz
X1
3
14
VCCIF
X2
4
13
SDO
5
12
SDI
INT1
6
11
SCLK
1Hz
7
10
CE
GND
8
9
VCC2
INT0
SERMODE
DIP (300 mils)
Package Dimension Information can be found at:
www.maxim-ic.com/DallasPackInfo
TYPICAL OPERATING CIRCUIT
SPI is a trademark of Motorola, Inc.
1 of 21
REV: 071105
DS1306
ORDERING INFORMATION
PART
DS1306
DS1306+
DS1306N
DS1306N+
DS1306E+
DS1306EN+
DS1306EN+T&R
DS1306E+T&R
DS1306E
DS1306EN
DS1306EN/T&R
DS1306E/T&R
TEMP RANGE PIN-PACKAGE
TOP MARK*
0°C to +70°C
0°C to +70°C
-40°C to +85°C
0°C to +70°C
0°C to +70°C
-40°C to +85°C
-40°C to +85°C
0°C to +70°C
0°C to +70°C
-40°C to +85°C
-40°C to +85°C
0°C to +70°C
DS1306
DS1306 +
DS1306N
DS1306N +
DS1306 +
DS1306N +
DS1306N +
DS1306 +
DS1306
DS1306N
DS1306N
DS1306
16 DIP (300 mils)
16 DIP (300 mils)
16 DIP (300 mils)
16 DIP (300 mils)
20 TSSOP (173 mils)
20 TSSOP (173 mils)
20 TSSOP (173 mils)
20 TSSOP (173 mils)
20 TSSOP (173 mils)
20 TSSOP (173 mils)
20 TSSOP (173 mils)
20 TSSOP (173 mils)
+ Denotes a lead-free/RoHS-compliant device.
* An “N” on the top mark indicates an industrial device.
PIN DESCRIPTION
PIN
TSSOP
DIP
NAME
1
1
VCC2
2
2
VBAT
3
3
X1
5
4
X2
7
5
INT0
8
6
INT1
FUNCTION
Backup Power Supply. This is the secondary power supply pin. In systems
using the trickle charger, the rechargeable energy source is connected to this
pin.
Battery Input for Any Standard +3V Lithium Cell or Other Energy
Source. If not used, VBAT must be connected to ground. Diodes must not be
placed in series between VBAT and the battery, or improper operation will
result. UL recognized to ensure against reverse charging current when used
in conjunction with a lithium battery. See “Conditions of Acceptability” at
www.maxim-ic.com/TechSupport/QA/ntrl.htm.
Connections for Standard 32.768kHz Quartz Crystal. The internal
oscillator is designed for operation with a crystal having a specified load
capacitance of 6pF. For more information on crystal selection and crystal
layout considerations, refer to Application Note 58, “Crystal Considerations
with Dallas Real-Time Clocks.” The DS1306 can also be driven by an
external 32.768kHz oscillator. In this configuration, the X1 pin is connected
to the external oscillator signal and the X2 pin is floated.
Active-Low Interrupt 0 Output. The INT0 pin is an active-low output of
the DS1306 that can be used as an interrupt input to a processor. The INT0
pin can be programmed to be asserted by Alarm 0. The INT0 pin remains
low as long as the status bit causing the interrupt is present and the
corresponding interrupt enable bit is set. The INT0 pin operates when the
DS1306 is powered by VCC1, VCC2, or VBAT. The INT0 pin is an open-drain
output and requires an external pullup resistor.
Interrupt 1 Output. The INT1 pin is an active high output of the DS1306
that can be used as an interrupt input to a processor. The INT1 pin can be
programmed to be asserted by Alarm 1. When an alarm condition is present,
the INT1 pin generates a 62.5ms active-high pulse. The INT1 pin operates
only when the DS1306 is powered by VCC2 or VBAT. When active, the INT1
pin is internally pulled up to VCC2 or VBAT. When inactive, the INT1 pin is
internally pulled low.
2 of 21
DS1306
PIN DESCRIPTION (continued)
PIN
TSSOP
DIP
9
7
10
8
11
9
12
10
14
11
15
12
16
13
17
14
18
15
20
16
4, 6, 13,
19
—
NAME
FUNCTION
1Hz Output. The 1Hz pin provides a 1Hz square wave output. This output
is active when the 1 Hz bit in the control register is a logic 1. Both INT0 and
1Hz
1Hz pins are open-drain outputs. The interrupt, 1Hz signal, and the internal
clock continue to run regardless of the level of VCC (as long as a power
source is present).
GND
Ground
Serial Interface Mode. The SERMODE pin offers the flexibility to choose
between two serial interface modes. When connected to GND, standard
SERMODE
3-wire communication is selected. When connected to VCC, SPI
communication is selected.
Chip Enable. The chip enable signal must be asserted high during a read or
CE
a write for both 3-wire and SPI communication. This pin has an internal 55k
pulldown resistor (typical).
Serial Clock. SCLK is used to synchronize data movement on the serial
SCLK
interface for either the SPI or 3-wire interface.
Serial Data In. When SPI communication is selected, the SDI pin is the
serial data input for the SPI bus. When 3-wire communication is selected,
SDI
this pin must be tied to the SDO pin (the SDI and SDO pins function as a
single I/O pin when tied together).
Serial Data Out. When SPI communication is selected, the SDO pin is the
serial data output for the SPI bus. When 3-wire communication is selected,
SDO
this pin must be tied to the SDI pin (the SDI and SDO pins function as a
single I/O pin when tied together). VCCIF provides the logic high level.
Interface Logic Power-Supply Input. The VCCIF pin allows the DS1306 to
drive SDO and 32kHz output pins to a level that is compatible with the
VCCIF
interface logic, thus allowing an easy interface to 3V logic in mixed supply
systems. This pin is physically connected to the source connection of the pchannel transistors in the output buffers of the SDO and 32kHz pins.
32.768kHz Output. The 32kHz pin provides a 32.768kHz output. This
32kHz
signal is always present. VCCIF provides the logic high level.
Primary Power Supply. DC power is provided to the device on this pin.
VCC1
VCC1 is the primary power supply.
N.C.
No Connection
3 of 21
DS1306
DESCRIPTION
The DS1306 serial alarm real-time clock (RTC) provides a full binary coded decimal (BCD) clock
calendar that is accessed by a simple serial interface. The clock/calendar provides seconds, minutes,
hours, day, date, month, and year information. The end of the month date is automatically adjusted for
months with fewer than 31 days, including corrections for leap year. The clock operates in either the 24hour or 12-hour format with AM/PM indicator. In addition, 96 bytes of NV RAM are provided for data
storage.
An interface logic-power supply input pin (VCCIF) allows the DS1306 to drive SDO and 32kHz pins to a
level that is compatible with the interface logic. This allows an easy interface to 3V logic in mixed supply
systems. The DS1306 offers dual-power supplies as well as a battery-input pin. The dual-power supplies
support a programmable trickle charge circuit that allows a rechargeable energy source (such as a super
cap or rechargeable battery) to be used for a backup supply. The VBAT pin allows the device to be backed
up by a non-rechargeable battery. The DS1306 is fully operational from 2.0V to 5.5V.
Two programmable time-of-day alarms are provided by the DS1306. Each alarm can generate an
interrupt on a programmable combination of seconds, minutes, hours, and day. “Don’t care” states can be
inserted into one or more fields if it is desired for them to be ignored for the alarm condition. A 1Hz and a
32kHz clock output are also available.
The DS1306 supports a direct interface to SPI serial data ports or standard 3-wire interface. An easy-touse address and data format is implemented in which data transfers can occur 1 byte at a time or in
multiple-byte burst mode.
OPERATION
The block diagram in Figure 1 shows the main elements of the serial alarm RTC. The following
paragraphs describe the function of each pin.
Figure 1. BLOCK DIAGRAM
1Hz
4 of 21
DS1306
RECOMMENDED LAYOUT FOR CRYSTAL
Local ground plane (Layer 2)
X1
crystal
X2
GND
CLOCK ACCURACY
The accuracy of the clock is dependent upon the accuracy of the crystal and the accuracy of the match
between the capacitive load of the oscillator circuit and the capacitive load for which the crystal was
trimmed. Additional error is added by crystal frequency drift caused by temperature shifts. External
circuit noise coupled into the oscillator circuit can result in the clock running fast. Refer to Application
Note 58: Crystal Considerations with Dallas Real-Time Clocks for detailed information.
CLOCK, CALENDAR, AND ALARM
The time and calendar information is obtained by reading the appropriate register bytes. The RTC
registers are illustrated in Figure 2. The time, calendar, and alarm are set or initialized by writing the
appropriate register bytes. Note that some bits are set to 0. These bits always read 0 regardless of how
they are written. Also note that registers 12h to 1Fh (read) and registers 92h to 9Fh are reserved. These
registers always read 0 regardless of how they are written. The contents of the time, calendar, and alarm
registers are in the BCD format.. Values in the day register that correspond to the day of the week are
user-defined, but must be sequential (e.g. if 1 equals Sunday, 2 equals Monday and so on). The day
register increments at midnight. Illogical time and date entries result in undefined operation.
WRITING TO THE CLOCK REGISTERS
The internal time and date registers continue to increment during write operations. However, the
countdown chain is reset when the seconds register is written. Writing the time and date registers within
one second after writing the seconds register ensures consistent data.
Terminating a write before the last bit is sent aborts the write for that byte.
READING FROM THE CLOCK REGISTERS
Buffers are used to copy the time and date register at the beginning of a read. When reading in burst
mode, the user copy is static while the internal registers continue to increment.
5 of 21
DS1306
Figure 2. RTC REGISTERS AND ADDRESS MAP
HEX ADDRESS
READ
00H
01H
WRITE
80H
81H
02H
82H
Bit
7
0
0
0
03H
04H
05H
06H
07H
08H
83H
84H
85H
86H
87H
88H
0
0
0
M
M
09H
89H
M
Bit6
Bit5
Bit4
10 SEC
10 MIN
P
12
10-HR
A
24
10
0
0
0
0
10-DATE
0
10-MONTH
10-YEAR
10-SEC ALARM 0
10-MIN ALARM 0
P
12
10-HR
A
24
10
0AH
8AH
M
0
0BH
0CH
8BH
8CH
M
M
0DH
8DH
M
10 SEC ALARM 1
10 MIN ALARM 1
P
12
10-HR
A
24
10
0
0
0
0EH
8EH
0FH
10H
11H
12–1FH
8FH
90H
91H
92–9FH
A0–
FFH
20–7FH
M
Bit3
0
0
Bit2
Bit1
Bit0
SEC
MIN
HOURS
0
DAY
DATE
MONTH
YEAR
SEC ALARM 0
MIN ALARM 0
HOUR ALARM 0
RANGE
00–59
00–59
01–12 + P/A
00–23
01–07
1–31
01–12
00–99
00–59
00–59
01–12 + P/A
00–23
0
DAY ALARM 0
SEC ALARM 1
MIN ALARM 1
HOUR ALARM 1
0
DAY ALARM 1
—
CONTROL REGISTER
STATUS REGISTER
TRICKLE CHARGER REGISTER
RESERVED
96-BYTES USER RAM
01–07
00–59
00–59
01–12 + P/A
00–23
01–07
—
—
—
—
—
Note: Range for alarm registers does not include mask’m’ bits.
The DS1306 can be run in either 12-hour or 24-hour mode. Bit 6 of the hours register is defined as the
12- or 24-hour mode select bit. When high, the 12-hour mode is selected. In the 12-hour mode, bit 5 is
the AM/PM bit with logic high being PM. In the 24-hour mode, bit 5 is the second 10-hour bit (20 to 23
hours).
The DS1306 contains two time-of-day alarms. Time-of-day alarm 0 can be set by writing to registers 87h
to 8Ah. Time-of-day Alarm 1 can be set by writing to registers 8 Bh to 8 Eh. Bit 7 of each of the time-ofday alarm registers are mask bits (Table 1). When all of the mask bits are logic 0, a time-of-day alarm
only occurs once per week when the values stored in timekeeping registers 00h to 03h match the values
stored in the time-of-day alarm registers. An alarm is generated every day when bit 7 of the day alarm
register is set to a logic 1. An alarm is generated every hour when bit 7 of the day and hour alarm
registers is set to a logic 1. Similarly, an alarm is generated every minute when bit 7 of the day, hour, and
6 of 21
DS1306
minute alarm registers is set to a logic 1. When bit 7 of the day, hour, minute, and seconds alarm registers
is set to a logic 1, an alarm occurs every second.
During each clock update, the RTC compares the Alarm 0 and Alarm 1 registers with the corresponding
clock registers. When a match occurs, the corresponding alarm flag bit in the status register is set to a 1. If
the corresponding alarm interrupt enable bit is enabled, an interrupt output is activated.
Table 1. TIME-OF-DAY ALARM MASK BITS
ALARM REGISTER MASK BITS (BIT 7)
SECONDS MINUTES HOURS
DAYS
1
1
1
1
0
1
1
1
0
0
1
1
0
0
0
1
0
0
0
0
FUNCTION
Alarm once per second
Alarm when seconds match
Alarm when minutes and seconds match
Alarm hours, minutes, and seconds match
Alarm day, hours, minutes and seconds match
SPECIAL PURPOSE REGISTERS
The DS1306 has three additional registers (control register, status register, and trickle charger register)
that control the real-time clock, interrupts, and trickle charger.
CONTROL REGISTER (READ 0FH, WRITE 8FH)
BIT7
0
BIT6
WP
BIT5
0
BIT4
0
BIT3
0
BIT2
1Hz
BIT1
AIE1
BIT0
AIE0
WP (Write Protect) – Before any write operation to the clock or RAM, this bit must be logic 0. When
high, the write protect bit prevents a write operation to any register, including bits 0, 1, and 2 of the
control register. Upon initial power-up, the state of the WP bit is undefined. Therefore, the WP bit should
be cleared before attempting to write to the device. When WP is set, it must be cleared before any other
control register bit can be written.
1Hz (1Hz Output Enable) – This bit controls the 1Hz output. When this bit is a logic 1, the 1Hz output
is enabled. When this bit is a logic 0, the 1Hz output is high-Z.
AIE0 (Alarm Interrupt Enable 0) – When set to a logic 1, this bit permits the interrupt 0 request flag
(IRQF0) bit in the status register to assert INT0 . When the AIE0 bit is set to logic 0, the IRQF0 bit does
not initiate the INT0 signal.
AIE1 (Alarm Interrupt Enable 1) – When set to a logic 1, this bit permits the interrupt 1 request flag
(IRQF1) bit in the status register to assert INT1. When the AIE1 bit is set to logic 0, the IRQF1 bit does
not initiate an interrupt signal, and the INT1 pin is set to a logic 0 state.
7 of 21
DS1306
STATUS REGISTER (READ 10H)
BIT7
0
BIT6
0
BIT5
0
BIT4
0
BIT3
0
BIT2
0
BIT1
IRQF1
BIT0
IRQF0
IRQF0 (Interrupt 0 Request Flag) – A logic 1 in the interrupt request flag bit indicates that the current
time has matched the Alarm 0 registers. If the AIE0 bit is also a logic 1, the INT0 pin goes low. IRQF0 is
cleared when the address pointer goes to any of the Alarm 0 registers during a read or write. IRQF0 is
activated when the device is powered by VCC1, VCC2, or VBAT.
IRQF1 (Interrupt 1 Request Flag) – A logic 1 in the interrupt request flag bit indicates that the current
time has matched the Alarm 1 registers. If the AIE1 bit is also a logic 1, the INT1 pin generates a 62.5ms
active-high pulse. IRQF1 is cleared when the address pointer goes to any of the alarm 1 registers during a
read or write. IRQF1 is activated only when the device is powered by VCC2 or VBAT.
TRICKLE CHARGE REGISTER (READ 11H, WRITE 91H)
This register controls the trickle charge characteristics of the DS1306. The simplified schematic of Figure
3 shows the basic components of the trickle charger. The trickle charge select (TCS) bits (bits 4–7)
control the selection of the trickle charger. In order to prevent accidental enabling, only a pattern of 1010
enables the trickle charger. All other patterns disable the trickle charger. The DS1306 powers up with the
trickle charger disabled. The diode select (DS) bits (bits 2–3) select whether one diode or two diodes are
connected between VCC1 and VCC2. The diode select (DS) bits (bits 2–3) select whether one diode or two
diodes are connected between VCC1 and VCC2. The resistor select (RS) bits select the resistor that is
connected between VCC1 and VCC2. The resistor and diodes are selected by the RS and DS bits as shown
in Table 2.
Figure 3. PROGRAMMABLE TRICKLE CHARGER
8 of 21
DS1306
Table 2. TRICKLE CHARGER RESISTOR AND DIODE SELECT
TCS
Bit 7
TCS
Bit 6
TCS
Bit 5
TCS
Bit 4
DS
Bit 3
DS
Bit 2
RS
Bit 1
RS
Bit 0
FUNCTION
X
X
X
X
X
X
0
0
Disabled
X
X
X
X
0
0
X
X
Disabled
X
X
X
X
1
1
X
X
Disabled
1
0
1
0
0
1
0
1
1 Diode, 2kΩ
1
0
1
0
0
1
1
0
1 Diode, 4kΩ
1
0
1
0
0
1
1
1
1 Diode, 8kΩ
1
0
1
0
1
0
0
1
2 Diodes, 2kΩ
1
0
1
0
1
0
1
0
2 Diodes, 4kΩ
1
0
1
0
1
0
1
1
2 Diodes, 8kΩ
0
1
0
1
1
1
0
0
Initial power-on state
If RS is 00, the trickle charger is disabled independently of TCS.
Diode and resistor selection is determined by the user according to the maximum current desired for
battery or super cap charging. The maximum charging current can be calculated as illustrated in the
following example. Assume that a system power supply of 5V is applied to VCC1 and a super cap is
connected to VCC2. Also assume that the trickle charger has been enabled with one diode and resister R1
between VCC1 and VCC2. The maximum current IMAX would, therefore, be calculated as follows:
IMAX = (5.0V - diode drop) / R1 » (5.0V - 0.7V) / 2kΩ » 2.2mA
As the super cap charges, the voltage drop between VCC1 and VCC2 decreases and, therefore, the charge
current decreases.
POWER CONTROL
Power is provided through the VCC1, VCC2, and VBAT pins. Three different power supply configurations
are illustrated in Figure 4. Configuration 1 shows the DS1306 being backed up by a non-rechargeable
energy source such as a lithium battery. In this configuration, the system power supply is connected to
VCC1 and VCC2 is grounded. When VCC falls below VBAT the device switches into a low-current battery
backup mode. Upon power-up, the device switches from VBAT to VCC when VCC is greater than
VBAT + 0.2V. The device is write-protected whenever it is switched to VBAT.
Configuration 2 illustrates the DS1306 being backed up by a rechargeable energy source. In this case, the
VBAT pin is grounded, VCC1 is connected to the primary power supply, and VCC2 is connected to the
secondary supply (the rechargeable energy source). The DS1306 operates from the larger of VCC1 or
VCC2. When VCC1 is greater than VCC2 + 0.2V (typical), VCC1 powers the DS1306. When VCC1 is less than
VCC2, VCC2 powers the DS1306. The DS1306 does not write-protect itself in this configuration.
Configuration 3 shows the DS1306 in battery-operate mode, where the device is powered only by a single
battery. In this case, the VCC1 and VBAT pins are grounded and the battery is connected to the VCC2 pin.
Only these three configurations are allowed. Unused supply pins must be grounded.
9 of 21
DS1306
Figure 4. POWER SUPPLY CONFIGURATIONS
CONFIGURATION 1: BACKUP SUPPLY IS
NONRECHARGEABLE LITHIUM BATTERY
NOTE: DEVICE IS WRITE-PROTECTED IF VCC < VCCTP.
CONFIGURATION 2: BACKUP SUPPLY IS A
RECHARGEABLE BATTERY OR SUPER
CAPACITOR
NOTE: DEVICE DOES NOT PROVIDE AUTOMATIC WRITE PROTECTION.
CONFIGURATION 3: BATTERY OPERATE
MODE
10 of 21
DS1306
SERIAL INTERFACE
The DS1306 offers the flexibility to choose between two serial interface modes. The DS1306 can
communicate with the SPI interface or with a standard 3-wire interface. The interface method used is
determined by the SERMODE pin. When this pin is connected to VCC, SPI communication is selected.
When this pin is connected to ground, standard 3-wire communication is selected.
SERIAL PERIPHERAL INTERFACE (SPI)
The serial peripheral interface (SPI) is a synchronous bus for address and data transfer and is used when
interfacing with the SPI bus on specific Motorola microcontrollers such as the 68HC05C4 and the
68HC11A8. The SPI mode of serial communication is selected by tying the SERMODE pin to VCC.
Four pins are used for the SPI. The four pins are the SDO (serial data out), SDI (serial data in), CE (chip
enable), and SCLK (serial clock). The DS1306 is the slave device in an SPI application, with the
microcontroller being the master.
The SDI and SDO pins are the serial data input and output pins for the DS1306, respectively. The CE
input is used to initiate and terminate a data transfer. The SCLK pin is used to synchronize data
movement between the master (microcontroller) and the slave (DS1306) devices.
The shift clock (SCLK), which is generated by the microcontroller, is active only during address and data
transfer to any device on the SPI bus. The inactive clock polarity is programmable in some
microcontrollers. The DS1306 determines on the clock polarity by sampling SCLK when CE becomes
active. Therefore either SCLK polarity can be accommodated. Input data (SDI) is latched on the internal
strobe edge and output data (SDO) is shifted out on the shift edge (Figure 5). There is one clock for each
bit transferred. Address and data bits are transferred in groups of eight.
Figure 5. SERIAL CLOCK AS A FUNCTION OF MICROCONTROLLER
CLOCK POLARITY (CPOL)
CE
CPOL = 1
SCLK
SHIFT DATA OUT (READ)
DATA LATCH (WRITE)
SHIFT DATA OUT (READ)
DATA LATCH (WRITE)
CPOL = 0
SCLK
NOTE 1: CPHA BIT POLARITY (IF APPLICABLE) MAY NEED TO BE SET ACCORDINGLY.
NOTE 2: CPOL IS A BIT THAT IS SET IN THE MICROCONTROLLER’S CONTROL REGISTER.
NOTE 3: SDO REMAINS AT HIGH-Z UNTIL 8 BITS OF DATA ARE READY TO BE SHIFTED OUT DURING A READ.
11 of 21
DS1306
ADDRESS AND DATA BYTES
Address and data bytes are shifted MSB first into the serial data input (SDI) and out of the serial data
output (SDO). Any transfer requires the address of the byte to specify a write or read to either a RTC or
RAM location, followed by one or more bytes of data. Data is transferred out of the SDO for a read
operation and into the SDI for a write operation (Figures 6 and 7).
Figure 6. SPI SINGLE-BYTE WRITE
* SCLK CAN BE EITHER POLARITY.
Figure 7. SPI SINGLE-BYTE READ
* SCLK CAN BE EITHER POLARITY.
The address byte is always the first byte entered after CE is driven high. The most significant bit (A7) of
this byte determines if a read or write takes place. If A7 is 0, one or more read cycles occur. If A7 is 1,
one or more write cycles occur.
Data transfers can occur one byte at a time or in multiple-byte burst mode. After CE is driven high an
address is written to the DS1306. After the address, 1 or more data bytes can be written or read. For a
single-byte transfer, one byte is read or written and then CE is driven low. For a multiple-byte transfer,
however, multiple bytes can be read or written to the DS1306 after the address has been written. Each
read or write cycle causes the RTC register or RAM address to automatically increment. Incrementing
continues until the device is disabled. When the RTC is selected, the address wraps to 00h after
incrementing to 1Fh (during a read) and wraps to 80h after incrementing to 9Fh (during a write). When
the RAM is selected, the address wraps to 20h after incrementing to 7Fh (during a read) and wraps to
A0h after incrementing to FFh (during a write).
12 of 21
DS1306
Figure 8. SPI MULTIPLE-BYTE BURST TRANSFER
READING AND WRITING IN BURST MODE
Burst mode is similar to a single-byte read or write, except that CE is kept high and additional SCLK
cycles are sent until the end of the burst. The clock registers and the user RAM may be read or written in
burst mode. When accessing the clock registers in burst mode, the address pointer will wrap around after
reaching 1Fh (9Fh for writes). When accessing the user RAM in burst mode, the address pointer wraps
around after reaching 7Fh (FFh for writes).
3-WIRE INTERFACE
The 3-wire interface mode operates similar to the SPI mode. However, in 3-wire mode there is one I/O
instead of separate data in and data out signals. The 3-wire interface consists of the I/O (SDI and SDO
pins tied together), CE, and SCLK pins. In 3-wire mode, each byte is shifted in LSB first, unlike SPI
mode, where each byte is shifted in MSB first.
As is the case with the SPI mode, an address byte is written to the device followed by a single data byte
or multiple data bytes. Figure 9 illustrates a read and write cycle. In 3-wire mode, data is input on the
rising edge of SCLK and output on the falling edge of SCLK.
13 of 21
DS1306
Figure 9. 3-WIRE SINGLE BYTE TRANSFER
SINGLE-BYTE READ
CE
SCLK
I/O*
A0
A1
A2
A3
A4
A5 A6
0
D0
D1
D2
D3
D4
D5
D6
D7
SINGLE-BYTE WRITE
CE
SCLK
I/O*
A0
A1
A2
A3
A4
A5
A6
1
D0
D1
D2
D3
D4
D5
D6 D7
NOTE: IN BURST MODE, CE IS KEPT HIGH AND ADDITIONAL SCLK CYCLES ARE SENT UNTIL THE END OF THE BURST.
*I/O IS SDI AND SDO TIED TOGETHER.
14 of 21
DS1306
ABSOLUTE MAXIMUM RATINGS
Voltage Range on Any Pin Relative to Ground……………………………………………..-0.5V to +7.0V
Storage Temperature Range……………………………………………………………….-55°C to +125°C
Soldering Temperature.……………………………….See IPC/JEDEC Standard J-STD-020 Specification
This is a stress rating only and functional operation of the device at these or any other conditions beyond those indicated in the operation
sections of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods of time can affect
reliability.
OPERATING RANGE
RANGE
Commercial
TEMP RANGE
0°C to +70°C
VCC (V)
2.0 to 5.5 VCC1 or VCC2
Industrial
-40°C to +85°C
2.0 to 5.5 VCC1 or VCC2
RECOMMENDED DC OPERATING CONDITIONS
(TA = Over the operating range, unless otherwise specified.)
PARAMETER
Supply Voltage
VCC1, VCC2
Logic 1 Input
SYMBOL
MIN
TYP
MAX
UNITS
NOTES
1, 8
VCC1, VCC2
2.0
5.5
V
VIH
2.0
V
V
V
VBAT Battery Voltage
VBAT
2.0
VCC + 0.3
+0.3
+0.8
5.5
VCCIF Supply Voltage
VCCIF
2.0
5.5
Logic 0 Input
VIL
VCC = 2.0V
VCC = 5V
15 of 21
-0.3
V
10
DS1306
DC ELECTRICAL CHARACTERISTICS
(TA = Over the operating range, unless otherwise specified.)
PARAMETER
Input Leakage
Output Leakage
IOL = 1.5mA
Logic 0 Output
IOL = 4.0mA
IOH = -0.4mA
Logic 1 Output
IOH = -1.0mA
Logic 1 Output Current
(INT1 pin)
IOH,
INT1
VCC1 Active Supply Current
ICC1A
VCC1 Timekeeping Current
ICC1T
VCC2 Active Supply Current
ICC2A
VCC2 Timekeeping Current
ICC2T
Battery Timekeeping Current
Battery Timekeeping Current
(IND)
IBAT
VBAT = 3V
IBAT
VBAT = 3V
VCC Trip Point
SYMBOL
MIN
-100
-1
ILI
ILO
VOL
VOH
VCC = 2.0
VCC = 5V
VCCIF = 2.0V
VCCIF = 5V
(VCC2, VBAT)
-0.3V
VCC1 = 2.0V
VCC1 = 5V
VCC1 = 2.0V
VCC1 = 5V
VCC2 = 2.0V
VCC2 = 5V
VCC2 = 2.0V
VCC2 = 5V
TYP
UNITS
mA
mA
V
-100
mA
0.425
1.28
25.3
81
0.4
1.2
0.4
1
NOTES
V
1.6
2.4
VBAT 50
VCCTP
MAX
+500
+1
0.4
0.4
mA
2, 7
mA
1, 7
mA
2, 8
mA
1, 8
550
nA
9
800
nA
9
VBAT +
200
mV
Trickle Charge Resistors
R1
R2
R3
2
4
8
kW
Trickle Charger Diode Voltage
Drop
VTD
0.7
V
CAPACITANCE
(TA = +25°C)
PARAMETER
Input Capacitance
Output Capacitance
Crystal Capacitance
SYMBOL
CI
CO
CX
16 of 21
MIN
TYP
10
15
6
MAX
UNITS
pF
pF
pF
NOTES
DS1306
3-WIRE AC ELECTRICAL CHARACTERISTICS
(TA = Over the operating range, unless otherwise specified.) (Figure 10 and Figure 11)
PARAMETER
Data to CLK Setup
CLK to Data Hold
CLK to Data Delay
CLK Low Time
CLK High Time
CLK Frequency
CLK Rise and Fall
CE to CLK Setup
CLK to CE Hold
CE Inactive Time
CE to Output High-Z
SCLK to Output High-Z
SYMBOL
VCC = 2.0V
tDC
VCC = 5V
VCC = 2.0V
tCDH
VCC = 5V
VCC = 2.0V
tCDD
VCC = 5V
VCC = 2.0V
tCL
VCC = 5V
VCC = 2.0V
tCH
VCC = 5V
VCC = 2.0V
tCLK
VCC = 5V
VCC = 2.0V
tR, t F
VCC = 5V
VCC = 2.0V
tCC
VCC = 5V
VCC = 2.0V
tCCH
VCC = 5V
VCC = 2.0V
tCWH
VCC = 5V
VCC = 2.0V
tCDZ
VCC = 5V
VCC = 2.0V
tCCZ
VCC = 5V
17 of 21
MIN
200
50
280
70
TYP
MAX
800
200
1000
250
1000
250
DC
0.6
2.0
2000
500
4
1
240
60
4
1
280
70
280
70
UNITS
NOTES
ns
3, 4
ns
3, 4
ns
3, 4, 5
ns
4
ns
4
MHz
4
ns
ms
4
ns
4
ms
4
ns
3, 4
ns
3, 4
DS1306
Figure 10. TIMING DIAGRAM: 3-WIRE READ DATA TRANSFER
* I/O IS SDI AND SDO TIED TOGETHER.
Figure 11. TIMING DIAGRAM: 3-WIRE WRITE DATA TRANSFER
* I/O IS SDI AND SDO TIED TOGETHER.
18 of 21
DS1306
SPI AC ELECTRICAL CHARACTERISTICS
(TA = Over the operating range, unless otherwise specified.)
PARAMETER
Data to CLK Setup
CLK to Data Hold
CLK to Data Delay
CLK Low Time
CLK High Time
CLK Frequency
CLK Rise and Fall
CE to CLK Setup
CLK to CE Hold
CE Inactive Time
CE to Output High-Z
SYMBOL
VCC = 2.0V
tDC
VCC = 5V
VCC = 2.0V
tCDH
VCC = 5V
VCC = 2.0V
tCDD
VCC = 5V
VCC = 2.0V
tCL
VCC = 5V
VCC = 2.0V
tCH
VCC = 5V
VCC = 2.0V
tCLK
VCC = 5V
VCC = 2.0V
tR, t F
VCC = 5V
VCC = 2.0V
tCC
VCC = 5V
VCC = 2.0V
tCCH
VCC = 5V
VCC = 2.0V
tCWH
VCC = 5V
VCC = 2.0V
tCDZ
VCC = 5V
19 of 21
MIN
200
50
280
70
TYP
MAX
800
200
1000
250
1000
250
DC
0.6
2.0
2000
500
4
1
240
60
4
1
280
70
UNITS
NOTES
ns
3, 4
ns
3, 4
ns
3, 4, 5
ns
4
ns
4
MHz
4
ns
ms
4
ns
4
ms
4
ns
3, 4
DS1306
Figure 12. TIMING DIAGRAM: SPI READ DATA TRANSFER
* SCLK CAN BE EITHER POLARITY, TIMING SHOWN FOR CPOL = 1.
Figure 13. TIMING DIAGRAM: SPI WRITE DATA TRANSFER
* SCLK CAN BE EITHER POLARITY, TIMING SHOWN FOR CPOL = 1.
20 of 21
DS1306
NOTES:
1) ICC1T and ICC2T are specified with CE set to a logic 0.
2) ICC1A and ICC2A are specified with CE = VCC, SCLK = 2MHz at VCC = 5V; SCLK = 500kHz at VCC =
2.0V, VIL = 0V, VIH = VCC.
3) Measured at VIH = 2.0V or VIL = 0.8V and 10ms maximum rise and fall time.
4) Measured with 50pF load.
5) Measured at VOH = 2.4V or VOL = 0.4V.
6) VCC = VCC1, when VCC1 > VCC2 + 0.2V (typical); VCC = VCC2, when VCC2 > VCC1.
7) VCC2 = 0V.
8) VCC1 = 0V.
9) VCC1 < VBAT.
10) VCCIF must be less than or equal to the largest of VCC1, VCC2, and VBAT.
21 of 21
Maxim/Dallas Semiconductor cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a Maxim/Dallas Semiconductor product.
No circuit patent licenses are implied. Maxim/Dallas Semiconductor reserves the right to change the circuitry and specifications without notice at any time.
Maxim Integrated Products, 120 San Gabriel Drive, Sunnyvale, CA 94086 408-737-7600
© 2005 Maxim Integrated Products · Printed USA
The Maxim logo is a registered trademark of Maxim Integrated Products, Inc. The Dallas logo is a registered trademark of Dallas Semiconductor Corporation.