XP Power JSM1024S3V3 Dc-dc converter Datasheet

JSM10 Series
DC-DC Converter
10 Watts
xxx Series
• Regulated Single & Dual Output
• 2:1 Input Range
• 1” x 1” Package
• 1500 VDC Isolation
• Operating Temperature -40 °C to +100 °C
• ITE Safety Approvals
• Optional Remote On/Off
• Optional Heatsink
• Metal Case
Dimensions:
• 3 Year Warranty
JSM10:
1.00 x 1.00 x 0.40” (25.4 x 25.4 x 10.16 mm)
Models & Ratings
Input voltage
9-18V
18-36V
36-75V
Output voltage
Output current
Input current(1,2)
No load
Full load
Maximum
capacitive load(3)
Efficiency
Model number(4)
JSM1012S3V3
3V3
2.50 A
840 mA
4700 µF
82%
5V
2.00 A
980 mA
2200 µF
85%
JSM1012S05
5.1 V
2.00 A
1000 mA
2200 µF
85%
JSM1012S5V1
12 V
0.83 A
955 mA
330 µF
87%
JSM1012S12
15 V
0.67 A
950 mA
220 µF
88%
JSM1012S15
±5 V
±1.000 A
990 mA
±1000 µF
84%
JSM1012D05
±12 V
±0.416 A
955 mA
±150 µF
87%
JSM1012D12
±15 V
±0.333 A
955 mA
±100 µF
87%
JSM1012D15
3V3
2.50 A
415 mA
4700 µF
83%
JSM1024S3V3
15 mA
5V
2.00 A
490 mA
2200 µF
85%
JSM1024S05
5.1 V
2.00 A
500 mA
2200 µF
85%
JSM1024S5V1
12 V
0.83 A
470 mA
330 µF
88%
JSM1024S12
15 V
0.67 A
470 mA
220 µF
89%
JSM1024S15
±5 V
±1.000 A
490 mA
±1000 µF
85%
JSM1024D05
±12 V
±0.416 A
475 mA
±150 µF
88%
JSM1024D12
±15 V
±0.333 A
470 mA
±100 µF
89%
JSM1024D15
3V3
2.50 A
205 mA
4700 µF
83%
JSM1048S3V3
12 mA
5V
2.00 A
240 mA
2200 µF
86%
JSM1048S05
5.1 V
2.00 A
250 mA
2200 µF
85%
JSM1048S5V1
12 V
0.83 A
235 mA
330 µF
89%
JSM1048S12
15 V
0.67 A
235 mA
220 µF
89%
JSM1048S15
±5 V
±1.000 A
240 mA
±1000 µF
86%
JSM1048D05
±12 V
±0.416 A
240 mA
±150 µF
87%
JSM1048D12
±15 V
±0.333 A
235 mA
±100 µF
88%
JSM1048D15
10 mA
Notes
1. Input currents measured at nominal input voltage.
2. Input current is typically 5 mA at nominal input voltage when output is turned off with optional remote on/off.
3. Maximum capacitive load is per output.
4. Add suffix “-R” for optional remote on/off, “-HK” for optional heatsink or “-RHK” for optional remote on/off and heatsink.
1
www.xppower.com
JSM10 Series
DC-DC Converter
Input
Characteristic
Input Voltage Range
Input Filter
Minimum
Typical
Notes & Conditions
Maximum
Units
9.0
18
VDC
12 V nominal
18.0
36
VDC
24 V nominal
36.0
75
VDC
48 V nominal
VDC for 1 s
24 V models
Internal Pi type
12 V models
25
50
Input Surge
100
48 V models
ON at >9V, OFF at <8.5 V
12 V models
Undervoltage Lockout
ON at >18V, OFF at <17 V
24 V models
ON at >36V, OFF at <34 V
48 V models
Remote On/Off
ON: Logic high (3.5-12 V) or open circuit
OFF: Logic low (<1.2 V) or short pin 2 to pin 6
Output
Characteristic
Minimum
Output Voltage
3.3
Typical
Maximum
Units
Notes & Conditions
30
VDC
See Models and Ratings table
Initial Set Accuracy
±2.0
%
Output Voltage Balance
±2.0
%
For dual output with balanced laods
A
No minimum load required
Minimum Load
At full load
Line Regulation
±1.0
%
From minimum to maximum input at full load
Load Regulation
±0.5/±1.0
%
Single / Dual output, from 0 to full load
Cross Regulation
±5.0
%
On dual output models when one load is varied between
25% and 100% and other is fixed at 100%
5
% deviation
Transient Response
3
Ripple & Noise
Overload Protection
80/100
mV pk-pk
150
%
Short Circuit Protection
Recovery within 1% in less than 300 µs for a 25% load
change.
3.3 & 5V output / other models. 20 MHz bandwidth.
Measured using 0.47 µF ceramic capacitor.
Continuous Trip & Restart (Hiccup mode), with auto recovery
Maximum Capacitive Load
See Models and Ratings table
Temperature Coefficient
0.02
%/ ˚C
Maximum
Units
General
Characteristic
Minimum
Typical
Efficiency
Isolation: Input to Output
Isolation Resistance
85
%
60 s/1 s
pF
kHz
At 500 VDC
2000
50.8
W/in3
Ω
109
Switching Frequency
330
Power Density
Mean Time Between Failure
Weight
See Models and Ratings table
VDC
1500/1800
Isolation Capacitance
Notes & Conditions
2.5
MHrs
0.03 (15.0)
lb (g)
MIL-HDBK-217F, +25 °C GB
Environmental
Characteristic
Minimum
Operating Temperature
-40
Storage Temperature
-50
Typical
Case Temperature
Humidity
Maximum
Units
Notes & Conditions
+100
°C
See Derating Curve.
+125
°C
+100
°C
95
%RH
Cooling
Non-condensing
Natural convection
EMC: Emissions
Phenomenon
Standard
Test Level
Conducted
EN55022
Class A
www.xppower.com
Notes & Conditions
2
JSM10 Series
DC-DC Converter
EMC: Immunity
Test Level
Criteria
ESD
EN61000-4-2
±8 kV air discharge, ±6 kV contact
A
Radiated
EN61000-4-3
10 V/m
A
EFT/Burst
EN61000-4-4
±2 kV
A
With external capacitor,
suggested part is CHEMI-CON KY 330µF/100V
Surge
EN61000-4-5
±1 kV
A
With external capacitor,
suggested part is CHEMI-CON KY 330µF/100V
Conducted
EN61000-4-6
10 V rms
A
Phenomenon
Standard
Notes & Conditions
Safety Approvals
Safety Agency
Safety Standard
CB Report
IEC60950-1
Notes & Conditions
Information Technology
UL
UL/cUL60950-1
Information Technology
Mechanical Details
Optional Heatsink (-HK)
1.00 (25.4)
0.40 (10.16) 0.40 (10.16)
4
0.80 (20.3)
Bottom View
1
2
0.20
(5.08)
0.24
(6.0)
0.40 ±0.02
(10.16 ±0.5)
5
1.00 (25.4)
3
0.64 (16.3) Max.
0.10
(2.54)
0.69 (17.46) Max.
ø 0.04
(1.00)
1.22 (31.0) Max.
0.77 (19.50) Max.
Heat-Sink
6
0.30
(7.62)
Thermal Pad
Clamp
Converter
0.10
(2.54)
Pin Connections
Pin
1
2
3
4
5
6
Notes
1. All dimensions are in inches (mm)
2. Weight: 0.03 lbs (15.0g) approx.
3. Tolerance: X.XX±0.01 (X.X±0.25)
X.XXX±0.005 (X.XX±0.13)
4. Pin Tolerance: ±0.002 (±0.05)
Application Notes
Single
Dual
+Vin
+Vin
-Vin
-Vin
+Vout
+Vout
No Pin
Common
-Vout
-Vout
Optional Remote On/Off Optional Remote On/Off
Derating Curve
Output Power (%)
100
With optional heatsink (-HK)
0
-40
60
70
100
Ambient Temperature (°C)
3
www.xppower.com
09 Feb 16