NSC LMH6560 Quad, high-speed, closed-loop buffer Datasheet

LMH6560
Quad, High-Speed, Closed-Loop Buffer
General Description
Features
The LMH™6560 is a high speed, closed-loop buffer designed for applications requiring the processing of very high
frequency signals. While offering a small signal bandwidth of
680MHz, and a very high slew rate of 3100V/µs the
LMH6560 consumes only 46mA of quiescent current for all
four buffers. Total harmonic distortion into a load of 100Ω at
20MHz is −51dBc. The LMH6560 is configured internally for
a loop gain of one. Input resistance is 100kΩ and output
resistance is but 1.5Ω. Crosstalk between the buffers is only
−55dB. These characteristics make the LMH6560 an ideal
choice for the distribution of high frequency signals on
printed circuit boards. Differential gain and phase specifications of 0.10% and 0.03˚ respectively at 3.58MHz make the
LMH6560 well suited for the buffering of video signals.
The device is fabricated on National’s high speed VIP10
process using National’s proven high performance circuit
architectures.
n
n
n
n
n
n
n
Closed-loop quad buffer
680MHz small signal bandwidth
3100V/µs slew rate
0.10% / 0.03˚ differential gain / phase
−51dBc THD at 20MHz
Single supply operation (3V min.)
80mA output current
Applications
n
n
n
n
n
n
n
n
n
Multi-channel video distribution
Video switching and routing
High-speed analog multiplexing
Channelized EW
High-density buffering
Active filters
Broadcast and high definition TV systems
Medical imaging
Test equipment and instrumentation
Typical Schematic
20064235
LMH™ is a trademark of National Semiconductor Corporation.
© 2004 National Semiconductor Corporation
DS200642
www.national.com
LMH6560 Quad, High-Speed, Closed-Loop Buffer
December 2004
LMH6560
Absolute Maximum Ratings (Note 1)
Wave Soldering (10 sec.)
Storage Temperature Range
If Military/Aerospace specified devices are required,
please contact the National Semiconductor Sales Office/
Distributors for availability and specifications.
Supply Voltage (V+ –V−)
200V (Note 3)
Output Short Circuit Duration
+
Supply Voltage (V –V )
Voltage at Input/Output Pins
13V
−40˚C to +85˚C
Package Thermal Resistance (θJA) (Note 6), (Note 7)
V+ +0.8V, V− −0.8V
Soldering Information
Infrared or Convection (20 sec.)
3-10V
Operating Temperature Range
(Note 6), (Note 7)
(Note 4),(Note 5)
−
+150˚C
Operating Ratings (Note 1)
2000V (Note 2)
Machine Model
−65˚C to +150˚C
Junction Temperature (Note 6)
ESD Tolerance
Human Body Model
260˚C
235˚C
14-Pin SOIC
137˚C/W
14-Pin TSSOP
160˚C/W
± 5V Electrical Characteristics
Unless otherwise specified, all limits guaranteed for TJ = 25˚C, V+ = +5V, V− = −5V, VO = VCM = 0V and RL = 100Ω to 0V.
Boldface limits apply at the temperature extremes.
Symbol
Parameter
Conditions
Min
(Note 9)
Typ
(Note 8)
Max
(Note 9)
Units
Frequency Domain Response
SSBW
Small Signal Bandwidth
VO < 0.5VPP
680
MHz
GFN
Gain Flatness < 0.1dB
VO < 0.5VPP
375
MHz
FPBW
Full Power Bandwidth (−3dB)
VO = 2VPP (+10dBm)
280
MHZ
DG
Differential Gain
RL = 150Ω to 0V;
f = 3.58MHz
0.10
%
DP
Differential Phase
RL = 150Ω to 0V;
f = 3.58MHz
0.03
deg
3.3V Step (20-80%)
0.6
ns
0.7
ns
ns
Time Domain Response
tr
Rise Time
tf
Fall Time
ts
Settling Time to 0.1%
3.3V Step
9
OS
Overshoot
1V Step
4
%
SR
Slew Rate
(Note 11)
3100
V/µs
Distortion And Noise Performance
HD2
2nd Harmonic Distortion
VO = 2VPP; f = 20MHz
−58
dBc
HD3
3rd Harmonic Distortion
VO = 2VPP; f = 20MHz
−52
dBc
THD
Total Harmonic Distortion
VO = 2VPP; f = 20MHz
−51
dBc
en
Input-Referred Voltage Noise
f = 1MHz
3
CP
1dB Compression Point
f = 10MHz
+23
dBm
CT
Amplifier Crosstalk
Receiving Amplifier:
RS = 50Ω to 0V; f = 10MHz
−55
dB
nV/
SNR
Signal to Noise Ratio
f = 5MHz; VO = 1VPP
120
dB
AGM
Amplifier Gain Matching
RL = 2kΩ to 0V; f = 5MHz;
VO = 1VPP
0.05
dB
Static, DC Performance
ACL
Small Signal Voltage Gain
VOS
Input Offset Voltage
TC VOS
Temperature Coefficient Input
Offset Voltage
www.national.com
VO = 100mVPP
RL = 100Ω to 0V
0.97
0.995
VO = 100mVPP
RL = 2kΩ to 0V
0.99
0.998
2
(Note 12)
28
2
V/V
20
25
mV
µV/˚C
(Continued)
Unless otherwise specified, all limits guaranteed for TJ = 25˚C, V+ = +5V, V− = −5V, VO = VCM = 0V and RL = 100Ω to 0V.
Boldface limits apply at the temperature extremes.
Symbol
Parameter
Conditions
Min
(Note 9)
Typ
(Note 8)
−10
−14
−5
µA
nA/˚C
IB
Input Bias Current
(Note 10)
TC IB
Temperature Coefficient Input
Bias Current
(Note 12)
−4.7
ROUT
Output Resistance
RL = 100Ω to 0V; f = 100kHz
1.5
RL = 100Ω to 0V; f = 10MHz
1.6
PSRR
Power Supply Rejection Ratio
VS = ± 5V to VS = ± 5.25V;
VIN = 0V
IS
Supply Current, All 4 Buffers
No Load
48
44
Max
(Note 9)
Ω
67
46
Units
dB
58
63
mA
Miscellaneous Performance
RIN
Input Resistance
CIN
Input Capacitance
VO
Output Swing Positive
Output Swing Negative
ISC
IO
Output Short Circuit Current
Linear Output Current
100
kΩ
2
pF
RL = 100Ω to 0V
3.10
3.08
3.34
RL = 2kΩ to 0V
3.58
3.55
3.64
V
RL = 100Ω to 0V
−3.34
−3.20
−3.17
RL = 2kΩ to 0V
−3.64
−3.58
−3.55
Sourcing: VIN = V+; VO = 0V
−83
Sinking: VIN = V−; VO = 0V
83
Sourcing: VIN - VO = 0.5V
(Note 10)
−50
−42
−74
Sinking: VIN - VO = −0.5V
(Note 10)
50
40
74
V
mA
mA
5V Electrical Characteristics
Unless otherwise specified, all limits guaranteed for TJ = 25˚C, V+ = +5V, V− = 0V, VO = VCM = V+/2 and RL = 100Ω to V+/2.
Boldface limits apply at the temperature extremes.
Symbol
Parameter
Conditions
Min
(Note 9)
Typ
(Note 8)
Max
(Note 9)
Units
Frequency Domain Response
SSBW
Small Signal Bandwidth
VO < 0.5VPP
455
MHz
GFN
Gain Flatness < 0.1dB
VO < 0.5VPP
75
MHz
FPBW
Full Power Bandwidth (−3dB)
VO = 2VPP (+10dBm)
175
MHZ
DG
Differential Gain
RL = 150Ω to V+/2;
f = 3.58MHz
0.4
%
DP
Differential Phase
RL = 150Ω to V+/2;
f = 3.58MHz
0.09
deg
2.3VPP Step (20-80%)
0.8
ns
1.0
ns
ns
Time Domain Response
tr
Rise Time
tf
Fall Time
ts
Settling Time to 0.1%
2.3V Step
10
OS
Overshoot
1V Step
0
%
SR
Slew Rate
(Note 11)
1445
V/µs
3
www.national.com
LMH6560
± 5V Electrical Characteristics
LMH6560
5V Electrical Characteristics
(Continued)
Unless otherwise specified, all limits guaranteed for TJ = 25˚C, V+ = +5V, V− = 0V, VO = VCM = V+/2 and RL = 100Ω to V+/2.
Boldface limits apply at the temperature extremes.
Symbol
Parameter
Min
(Note 9)
Conditions
Typ
(Note 8)
Max
(Note 9)
Units
Distortion And Noise Performance
HD2
2nd Harmonic Distortion
VO = 2VPP; f = 20MHz
−52
dBc
HD3
3rd Harmonic Distortion
VO = 2VPP; f = 20MHz
−54
dBc
THD
Total Harmonic Distortion
VO = 2VPP; f = 20MHz
−50
dBc
en
Input-Referred Voltage Noise
f = 1MHz
3
CP
1dB Compression Point
f = 10MHz
+14
dBm
CT
Amplifier Crosstalk
Receiving Amplifier:
RS = 50Ω to V+/2; f = 10MHz
−55
dB
SNR
Signal to Noise Ratio
VO = 1VPP; f = 5MHz
120
dB
AGM
Amplifier Gain Matching
VO = 1VPP
RL = 2kΩ to V+/2; f = 5MHz
0.5
dB
nV/
Static, DC Performance
ACL
Small Signal Voltage Gain
VO = 100mVPP
RL = 100Ω to V+/2
0.97
0.994
VO = 100mVPP
RL = 2kΩ to V+/2
0.99
0.998
VOS
Input Offset Voltage
TC VOS
Temperature Coefficient Input
Offset Voltage
(Note 12)
IB
Input Bias Current
(Note 10)
TC IB
Temperature Coefficient Input
Bias Current
ROUT
Output Resistance
2
V/V
13
15
mV
2
µV/˚C
−2.5
µA
(Note 12)
1.3
nA/˚C
RL = 100Ω to V+/2; f = 100kHz
1.7
RL = 100Ω to V+/2; f = 10MHz
2.0
−5
−5.5
PSRR
Power Supply Rejection Ratio
VS = +5V to VS = +5.5V;
VIN = VS/2
IS
Supply Current All 4 Buffer
No Load
48
45
Ω
67
21
dB
26
30
mA
Miscellaneous Performance
RIN
Input Resistance
16
kΩ
CIN
Input Capacitance
2
pF
VO
Output Swing Positive
Output Swing Negative
ISC
Output Short Circuit Current
RL = 100Ω to V+/2
3.74
3.70
3.85
RL = 2kΩ to V+/2
3.92
3.90
3.96
RL = 100Ω to V+/2
1.15
1.22
1.27
RL = 2kΩ to V+/2
1.04
1.08
1.10
Sourcing: VIN = V+; VO = V+/2
−
−40
+
Sinking: VIN = V ; VO = V /2
IO
Linear Output Current
www.national.com
V
22
Sourcing: VIN - VO = 0.5V
(Note 10)
−50
−40
−64
Sinking: VIN - VO = −0.5V
(Note 10)
30
20
45
4
V
mA
mA
Unless otherwise specified, all limits guaranteed for TJ = 25˚C, V+ = 3V, V− = 0V, VO = VCM = V+/2 and RL = 100Ω to V+/2.
Boldface limits apply at the temperature extremes.
Symbol
Parameter
Conditions
Min
(Note 9)
Typ
(Note 8)
Max
(Note 9)
Units
Frequency Domain Response
SSBW
Small Signal Bandwidth
VO < 0.5VPP
265
MHz
GFN
Gain Flatness < 0.1dB
VO < 0.5VPP
40
MHz
FPBW
Full Power Bandwidth (−3dB)
VO = 1VPP (+4.5dBm)
115
MHZ
1V Step (20-80%)
1.1
ns
Time Domain Response
tr
Rise Time
tf
Fall Time
ts
Settling Time to 0.1%
1V Step
OS
Overshoot
0.5V Step
0
%
SR
Slew Rate
(Note 11)
480
V/µs
1.3
ns
11
ns
Distortion And Noise Performance
HD2
2nd Harmonic Distortion
VO = 0.5VPP; f = 20MHz
−55
dBc
HD3
3rd Harmonic Distortion
VO = 0.5VPP; f = 20MHz
−61
dBc
THD
Total Harmonic Distortion
VO = 0.5VPP; f = 20MHz
−54
en
Input-Referred Voltage Noise
f = 1MHz
CP
1dB Compression Point
f = 10MHz
+4
dBm
CT
Amplifier Crosstalk
Receiving Amplifier:
RS = 50Ω to V+/2; f = 10MHz
−55
dB
dBc
3
nV/
SNR
Signal to Noise Ratio
f = 5MHz; VO = 1VPP
120
dB
AGM
Amplifier Gain Matching
RL = 2kΩ to V+/2;
f = 5MHz; VO = 1VPP
0.4
dB
Static, DC Performance
ACL
Small Signal Voltage Gain
VO = 100mVPP
RL = 100Ω to V+/2
0.97
0.99
VO = 100mVPP
RL = 2kΩ to V+/2
0.99
0.997
VOS
Input Offset Voltage
TC VOS
Temperature Coefficient Input
Offset Voltage
(Note 12)
IB
Input Bias Current
(Note 10)
TC IB
Temperature Coefficient Input
Bias Current
(Note 12)
ROUT
Output Resistance
RL = 100Ω to V+/2; f = 100kHz
1.6
−3
−3.5
RL = 100Ω to V /2; f = 10MHz
Power Supply Rejection Ratio
VS = +3V to VS = +3.5V;
VIN = VS/2
IS
Supply Current, All 4 Buffers
No Load
8
10
µV/˚C
−1.4
µA
0.3
nA/˚C
Ω
2.8
48
46
mV
2.6
2.1
+
PSRR
V/V
65
11
dB
15
18
mA
Miscellaneous Performance
RIN
Input Resistance
17
kΩ
CIN
Input Capacitance
2
pF
5
www.national.com
LMH6560
3V Electrical Characteristics
LMH6560
3V Electrical Characteristics
(Continued)
Unless otherwise specified, all limits guaranteed for TJ = 25˚C, V+ = 3V, V− = 0V, VO = VCM = V+/2 and RL = 100Ω to V+/2.
Boldface limits apply at the temperature extremes.
Symbol
VO
Output Swing Positive
Output Swing Negative
ISC
IO
Min
(Note 9)
Typ
(Note 8)
RL = 100Ω to V+/2
2.0
1.93
2.05
RL = 2kΩ to V+/2
2.1
2.0
2.15
Parameter
Output Short Circuit Current
Linear Output Current
Conditions
Max
(Note 9)
V
RL = 100Ω to V+/2
0.95
1.0
1.07
RL = 2kΩ to V+/2
0.85
0.90
1.0
Sourcing: VIN = V+; VO = V+/2
−26
Sinking: VIN = V−; VO = V+/2
14
Sourcing: VIN - VO = 0.5V
(Note 10)
−20
−13
−30
Sinking: VIN - VO = −0.5V
(Note 10)
12
8
20
Units
V
mA
mA
Note 1: Absolute Maximum Ratings indicate limits beyond which damage to the device may occur. Operating Ratings indicate conditions for which the device is
intended to be functional, but specific performance is not guaranteed. For guaranteed specifications and the test conditions, see the Electrical Characteristics.
Note 2: Human body model, 1.5kΩ in series with 100pF
Note 3: Machine Model, 0Ω in series with 200pF.
Note 4: Applies to both single-supply and split-supply operation. Continuous short circuit operation at elevated ambient temperature can result in exceeding the
maximum allowed junction temperature of 150˚C.
Note 5: Short circuit test is a momentary test. See next note.
Note 6: The maximum power dissipation is a function of TJ(MAX), θJA , and TA. The maximum allowable power dissipation at any ambient temperature is PD =
(TJ(MAX) - TA ) / θJA. All numbers apply for packages soldered directly onto a PC board.
Note 7: Electrical Table values apply only for factory testing conditions at the temperature indicated. Factory testing conditions result in very limited self-heating of
the device such that TJ = TA. There is no guarantee of parametric performance as indicated in the electrical tables under conditions of internal self-heating where
TJ > TA. See Applications section for information on temperature de-rating of this device.
Note 8: Typical Values represent the most likely parametric norm.
Note 9: All limits are guaranteed by testing or statistical analysis.
Note 10: Positive current corresponds to current flowing into the device.
Note 11: Slew rate is the average of the positive and negative slew rate. Average Temperature Coefficient is determined by dividing the change in a parameter at
temperature extremes by the total temperature change.
Note 12: Average Temperature Coefficient is determined by dividing the change in a parameter at temperature extremes by the total temperature change.
www.national.com
6
LMH6560
Connection Diagram
14-Pin SOIC/TSSOP
20064234
Top View
Ordering Information
Package
Part Number
Package Marking
Transport Media
NSC Drawing
14-pin SOIC
LMH6560MA
LMH6560MA
55 Units/Rail
M14A
LMH6560MAX
14-pin TSSOP
LMH6560MT
2.5k Units Tape and Reel
LMH6560MT
94 Units/Rail
LMH6560MTX
MTC14
2.5k Units Tape and Reel
7
www.national.com
LMH6560
Typical Performance Characteristics
At TJ = 25˚C, V+ = +5V, V− = −5V; unless otherwise speci-
fied.
Frequency Response
Frequency Response Over Temperature
20064206
20064207
Gain Flatness 0.1dB
Differential Gain and Phase
20064208
20064204
Differential Gain and Phase
Transient Response Positive
20064228
20064205
www.national.com
8
specified. (Continued)
Transient Response Negative
Transient Response Positive for Various VSUPPLY
20064226
20064227
Harmonic Distortion vs. VOUT @ 5MHz
Transient Response Negative for Various VSUPPLY
20064225
20064211
Harmonic Distortion vs. VOUT @ 10MHz
Harmonic Distortion vs. VOUT @ 20MHz
20064210
20064209
9
www.national.com
LMH6560
Typical Performance Characteristics At TJ = 25˚C, V+ = +5V, V− = −5V; unless otherwise
LMH6560
Typical Performance Characteristics At TJ = 25˚C, V+ = +5V, V− = −5V; unless otherwise
specified. (Continued)
THD vs. VOUT for Various Frequencies
Voltage Noise
20064229
20064224
Linearity VOUT vs. VIN
Crosstalk vs. Frequency
20064220
20064202
Crosstalk vs. Time
VOS vs. VSUPPLY for 3 Units
20064203
www.national.com
20064230
10
specified. (Continued)
VOS vs. VSUPPLY for Unit 1
VOS vs. VSUPPLY for Unit 2
20064231
20064232
VOS vs. VSUPPLY for Unit 3
IB vs. VSUPPLY (Note 10)
20064233
20064212
ROUT vs. Frequency
PSRR vs. Frequency
20064221
20064222
11
www.national.com
LMH6560
Typical Performance Characteristics At TJ = 25˚C, V+ = +5V, V− = −5V; unless otherwise
LMH6560
Typical Performance Characteristics At TJ = 25˚C, V+ = +5V, V− = −5V; unless otherwise
specified. (Continued)
ISUPPLY vs. VSUPPLY
ISUPPLY vs. VIN
20064236
20064216
VOUT vs. IOUT (Sinking)
VOUT vs. IOUT (Sourcing)
20064201
20064215
IOUT Sinking vs. VSUPPLY
IOUT Sourcing vs. VSUPPLY
20064213
20064214
www.national.com
12
specified. (Continued)
Large Signal Pulse Response @ VS = 3V
Small Signal Pulse Response
20064223
20064219
Large Signal Pulse Response @ VS = 5V
Large Signal Pulse Response @ VS = 10V
20064218
20064217
13
www.national.com
LMH6560
Typical Performance Characteristics At TJ = 25˚C, V+ = +5V, V− = −5V; unless otherwise
LMH6560
Application Notes
USING BUFFERS
A buffer is an electronic device delivering current gain but no
voltage gain. It is used in cases where low impedances need
to be driven and more drive current is required. Buffers need
a flat frequency response and small propagation delay. Furthermore, the buffer needs to be stable under resistive,
capacitive and inductive loads. High frequency buffer applications require that the buffer be able to drive transmission
lines and cables directly.
20064239
FIGURE 3.
In these three options it is seen that there is more than one
preferred method to reach an (end) point on a transmission
line. Until a certain point the designer can make his own
choice but the designer should keep in mind never to break
the rules about high frequency transport of signals. An explanation follows in the text below.
IN WHAT SITUATION WILL WE USE A BUFFER?
In case of a signal source not having a low output impedance
one can increase the output drive capability by using a
buffer. For example, an oscillator might stop working or have
frequency shift which is unacceptably high when loaded
heavily. A buffer should be used in that situation. Also in the
case of feeding a signal to an A/D converter it is recommended that the signal source be isolated from the A/D
converter. Using a buffer assures a low output impedance,
the delivery of a stable signal to the converter, and accommodation of the complex and varying capacitive loads that
the A/D converter presents to the Op Amp. Optimum value is
often found by experimentation for the particular application.
The use of buffers is strongly recommended for the handling
of high frequency signals, for the distribution of signals
through transmission lines or on pcb’s, or for the driving of
external equipment. There are several driving options:
• Use one buffer to drive one transmission line (see Figure
1)
• Use one buffer to drive to multiple points on one transmission line (see Figure 2)
• Use one buffer to drive several transmission lines each
driving a different receiver. (see Figure 3)
TRANSMISSION LINES
Introduction to transmission lines. The following is an overview of transmission line theory. Transmission lines can be
used to send signals from DC to very high frequencies. At all
points across the transmission line, Ohm’s law must apply.
For very high frequencies, parasitic behavior of the PCB or
cable comes into play. The type of cable used must match
the application. For example an audio cable looks like a coax
cable but is unusable for radar frequencies at 10GHz. In this
case one have to use special coax cables with lower attenuation and radiation characteristics.
Normally a pcb trace is used to connect components on a
pcb board together. An important consideration is the
amount of current carried by these pcb traces. Wider pcb
traces are required for higher current densities and for applications where very low series resistance is needed. When
routed over a ground plane, pcb traces have a defined
characteristic impedance. In many design situations characteristic impedance is not utilized. In the case of high frequency transmission, however it is necessary to match the
load impedance to the line characteristic impedance (more
on this later). Each trace is associated with a certain amount
of series resistance and series inductance and also exhibits
parallel capacitance to the ground plane. The combination of
these parameters defines the line’s characteristic impedance. The formula with which we calculate this impedance is
as follows:
Z0 = √(L/C)
In this formula L and C are the value/unit length, and R is
assumed to be zero. C and L are unknown in many cases so
we have to follow other steps to calculate the Z0. The characteristic impedance is a function of the geometry of the
cross section of the line. In (Figure 4) we see three cross
sections of commonly used transmission lines.
20064237
FIGURE 1.
20064238
FIGURE 2.
www.national.com
14
LMH6560
Application Notes
(Continued)
20064240
FIGURE 4.
Z0 can be calculated by knowing some of the physical dimensions of the pcb line, such as pcb thickness, width of the
trace and er, relative dielectric constant. The formula given in
transmission line theory for calculating Z0 is as follows:
20064243
FIGURE 5.
Next, there will be a discussion of some issues associated
with the interaction of the transmission line at the source and
at the load.
(1)
er relative dielectric constant
h pcb height
W trace width
th thickness of the copper
Connecting a Load Using a Transmission Line
In most cases, it is unrealistic to think that we can place a
driver or buffer so close to the load that we don’t need a
transmission line to transport the signal. The pcb trace
length between a driver and the load may affect operation
depending upon the operating frequency. Sometimes it is
possible to do measurements by connecting the DUT directly
to the analyzer. As frequencies become higher the short
lines from the DUT to the analyzer become long lines. When
this happens there is a need to use transmission lines. The
next point to examine is what happens when the load is
connected to the transmission line. When driving a load, it is
important to match the line and load impedance, otherwise
reflections will occur and this phenomena will distort the
signal. If a transient is applied at T = 0 (Figure 6, trace A) the
resultant waveform may be observed at the start point of the
transmission line. At this point (begin) on the transmission
line the voltage increases to (V) and the wave front travels
along the transmission line and arrives at the load at T = 10.
At any point across along the line I = V/Z0, where Z0 is the
impedance of the transmission line. For an applied transient
of 2V with Z0 = 50Ω the current from the buffer output stage
is 40mA. Many vintage op amps cannot deliver this level of
current because of an output current limitation of about
20mA or even less. At T = 10 the wave front arrives at the
load. Since the load is perfectly matched to the transmission
line all of the current traveling across the line will be absorbed and there will be no reflections. In this case source
and load voltages are exactly the same. When the load and
the transmission line have unequal values of impedance a
different situation results. Remember there is another basic
which says that energy cannot be lost. The power in the
transmission line is P = V2/R. In our example the total power
is 22/50 = 80mW. Assume a load of 75Ω. In that case a
power of 80mW arrives at the 75Ωload and causes a voltage
of the proper amplitude to maintain the incoming power.
If we ignore the thickness of the copper in comparison to the
width of the trace then we have the following equation:
(2)
With this formula it is possible to calculate the line impedance vs. the trace width. Figure 5 shows the impedance
associated with a given line width. Using the same formula it
is also possible to calculate what happens when er varies
over a certain range of values. Varying the er over a range of
1 to 10 gives a variation for the Characteristic Impedance of
about 40Ω from 80Ω to 38Ω. Most transmission lines are
designed to have 50Ω or 75Ω impedance. The reason for
that is that in many cases the pcb trace has to connect to a
cable whose impedance is either 50Ω or 75Ω. As shown er
and the line width influence this value.
15
www.national.com
LMH6560
Application Notes
is half the voltage seen at the output of the buffer, because
the series resistor in combination with Z0 forms a two-to-on
voltage divider. The result is a loss of 6dB. For video applications, amplifier gain is set to 2 in order to realize an overall
gain of 1. Many operational amplifiers have a relatively flat
frequency response when set to a gain of two compared to
unity gain. In trace B it is seen that, if the voltage reaches the
end of the transmission line, the line is perfectly matched
and no reflections will occur. The end point voltage stays at
half the output voltage of the opamp or buffer.
(Continued)
(3)
The voltage wavefront of 2.45V will now set about traveling
back over the transmission line towards the source, thereby
resulting in a reflection caused by the mismatch. On the
other hand if the load is less then 50Ω the backwards
traveling wavefront is subtracted from the incoming voltage
of 2V. Assume the load is 40Ω. Then the voltage across the
load is:
Driving More Than One Input
Another transmission line possibility is to route the trace via
several points along a transmission line (see Figure 2). This
is only possible if care is taken to observe certain restrictions. Failure to do so will result in impedance discontinuities
that will cause distortion of the signal. In the configuration of
Figure 2 there is a transmission line connected to the buffer
output and the end of the line is terminated with Z0. We have
seen in the section ’Connecting a load using a transmission
line’ that for the condition above, the signal throughout the
entire transmission line has the same value, that the value is
the nominal value initiated by the opamp output, and no
reflections occur at the end point. Because of the lack of
reflections no interferences will occur. Consequently the signal has every where on the line the same amplitude. This
allows the possibility of feeding this signal to the input port of
any device which has high ohmic impedance and low input
capacitance. In doing so keep in mind that the transient
arrives at different times at the connected points in the
transmission line. The speed of light in vacuum, which is
about 3 * 108m/sec, reduces through a transmission line or a
cable down to a value of about 2 * 108m/sec. The distance
the signal will travel in 1ns is calculated by solving the
following formula:
S = V*t
Where
S = distance
V = speed in the cable
T = time
This calculation gives the following result:
s = 2*108 * 1*10-9 = 0.2m
That is for each nanosecond the wave front shifts 20cm over
the length of the transmission line. Keep in mind that in a
distance of just 2cm the time displacement is already 100ps.
(4)
This voltage is now traveling backwards through the line
toward the start point. In the case of a sinewave interferences develop between the incoming waveform and the
backwards-going reflections, thus distorting the signal. If
there is no load at all at the end point the complete transient
of 2V is reflected and travels backwards to the beginning of
the line. In this case the current at the endpoint is zero and
the maximum voltage is reflected. In the case of a short at
the end of the line the current is at maximum and the voltage
is zero.
Using Serial Termination To More Than One
Transmission Line
Another way to reach several points via a transmission line is
to start several lines from one buffer output (see Figure 3).
This is possible only if the output can deliver the needed
current into the sum of all transmission lines. As can be seen
in this figure there is a series termination used at the beginning of the transmission line and the end of the line has no
termination. This means that only the signal at the endpoint
is usable because at all other points the reflected signal will
cause distortion over the line. Only at the endpoint will the
measured signal be the same as at the startpoint. Referring
to Figure 6 trace C, the signal at the beginning of the line has
a value of V/2 and at T = 0 this voltage starts traveling
towards the end of the transmission line. Once at the endpoint the line has no termination and 100% reflection will
occur. At T = 10 the reflection causes the signal to jump to 2V
and to start traveling back along the line to the buffer (see
Figure 6 trace D). Once the wavefront reaches the series
20064246
FIGURE 6.
Using Serial and Parallel Termination
Many applications, such as video, use a series resistance
between the driver and the transmission line (see Figure 1).
In this case the transmission line is terminated with the
characteristic impedance at both ends of the line. See Figure
6 trace B. The voltage traveling through the transmission line
www.national.com
16
(Continued)
termination resistor, provided the termination value is Z0, the
wavefront undergoes total absorption by the termination.
This is only true if the output impedance of the buffer/driver
is low in comparison to the characteristic impedance Z0. At
this moment the voltage in the whole transmission line has
the nominal value of 2V (see Figure 6 trace E). If the three
transmission lines each have a different length the particular
point in time at which the voltage at the series termination
resistor jumps to 2V is different for each case. However, this
transient is not transferred to the other lines because the
output of the buffer is low and this transient is highly attenuated by the combination of the termination resistor and the
output impedance of the buffer. A simple calculation illustrates the point. Assume that the output impedance is 5Ω.
For the frequency of interest the attenuation is VB/VA=55/5
=11, where A and B are the points in Figure 3. In this case
the voltage caused by the reflection is 2/11 = 0.18V. This
voltage is transferred to the remaining transmission lines in
sequence and following the same rules as before this voltage is seen at the end points of those lines. The lower the
output resistance the higher the decoupling between the
different lines. Furthermore one can see that at the endpoint
of these transmission lines there is a normal transient equal
to the original transient at the beginning point. However at all
other points of the transmission line there is a step voltage at
different distances from the startpoint depending at what
point this is measured (see trace D).
(5)
As calculated before in the section ‘Driving more than one
input’ the signal travels 20cm/ns so in 5ns this distance
indicated distance is 1m. So this example is easily verified.
APPLYING A CAPACITIVE LOAD
The assumption of pure resistance for the purpose of connecting the output stage of a buffer or opamp to a load is
appropriate as a first approximation. Unfortunately that is
only a part of the truth. Associated with this resistor is a
capacitor in parallel and an inductor in series. Any capacitance such as C1-1 which is connected directly to the output
stage is active in the loop gain as see in Figure 8. Output
capacitance, present also at the minus input in the case of a
buffer, causes an increasing phase shift leading to instability
or even oscillation in the circuit.
Measuring the Length of a Transmission Line
An open transmission line can be used to measure the
length of a particular transmission line. As can be seen in
Figure 7. The line of interest has a certain length. A transient
is applied at T = 0 and at that point in time the wavefront
starts traveling with an amplitude of V/2 towards the end of
the line where it is reflected back to the startpoint.
20064249
FIGURE 8.
Unfortunately the leads of the output capacitor also contain
series inductors which become more and more important at
high frequencies. At a certain frequency this series capacitor
and inductor forms an LC combination which becomes series resonant. At the resonant frequency the reactive component vanishes leaving only the ohmic resistance (R-1 or
R-2) of the series L/C combination. (see Figure 9).
20064247
FIGURE 7.
20064250
To calculate the length of the line it is necessary to measure
immediately after the series termination resistor. The voltage
at that point remains at half nominal voltage, thus V/2, until
the reflection returns and the voltage jumps to V. During an
interval of 5 ns the signal travels to the end of the line where
the wave front is reflected and returns to the measurement
point. During the time interval when the wavefront is traveling to the end of the transmission line and back the voltage
has a value of V/2. This interval is 10ns. The length can be
calculated with the following formula: S = (V*T)/2
FIGURE 9.
Consider a frequency sweep over the entire spectrum for
which the LMH6559 high frequency buffer is active. In the
first instance peaking occurs due to the parasitic capacitance connected at the load whereas at higher frequencies
the effects of the series combination of L and C become
17
www.national.com
LMH6560
Application Notes
LMH6560
Application Notes
USING GROUND PLANES
A ground plane on a printed circuit board provides for a low
ohmic connection everywhere on the board for use in connecting supply voltages or grounds. Multilayer boards often
make use of inner conductive layers for routing supply voltages. These supply voltage layers form a complete plane
rather than using discrete traces to connect the different
points together for the specified supply. Signal traces on the
other hand are routed on outside layers both top and bottom.
This allows for easy access for measurement purposes.
Fortunately, only very high density boards have signal layers
in the middle of the board. In an earlier section, the formula
for Z was derived as:
(Continued)
noticeable. This causes a distinctive dip in the output frequency sweep and this dip varies depending upon the particular capacitor as seen in Figure 10.
(6)
The width of a trace is determined by the thickness of the
board. In the case of a multilayer board the thickness is the
space between the trace and the first supply plane under this
trace layer. By common practice, layers do not have to be
evenly divided in the construction of a pcb. Refer to Figure
12. The design of a transmission line design over a pcb is
based upon the thickness of the different internal layers and
the er of the board material. The pcb manufacturer can
supply information about important specifications. For example, a nominal 1.6mm thick pcb produces a 50Ω trace for
a calculated width of 2.9mm. If this layer has a thickness of
0.35mm and for the same er, the trace width for 50Ω should
be of 0.63mm, as calculated from Equation 7, a derivation
from Equation 6.
20064251
FIGURE 10.
To minimize peaking due to CL a series resistor for the
purpose of isolation from the output stage should be used. A
low valued resistor will minimize the influence of such a load
capacitor. In a 50Ω system as is common in high frequency
circuits a 50Ω series resistor is often used. Usage of the
series resistor, as seen in Figure 11 eliminates the peaking
but not the dip. The dip will vary with the particular capacitor.
Using a resistor in series with a capacitor creates a rolloff of
6db/octave. Choice of a higher valued resistor, for example
500Ω to 1kΩ, and a capacitor of hundreds of pf’s provides
the expected response at lower frequencies. However, at
high frequencies the internal inductance is appreciable and
forms with the capacitor a series LC combination.
(7)
20064255
FIGURE 12.
Using a trace over a ground plane has big advantages over
the use of a standard single or double sided board. The main
advantage is that the electric field generated by the signal
transported over this trace is fixed between the trace and the
ground plane e.g. there is almost no possibility of radiation.
20064252
FIGURE 11.
www.national.com
18
overall circuit performance. This is especially valid for analog
circuits which are more sensitive to spurious noise and other
unwanted signals.
(Continued)
20064256
FIGURE 13.
This effect works to both sides because the circuit will not
generate radiation but the circuit is also not sensible if exposed to a certain radiation level. The same is also noticeable when placing components flat on the printed circuit
board. Standard through hole components when placed upright can act as antennae causing electric fields which can
be picked up by a nearby upright component. If placed
directly at the surface of the pcb this influence is much lower.
20064258
FIGURE 15.
As demonstrated in Figure 15 the power lines are routed
from both sides on the pcb. In this case a current loop is
created as indicated by the dotted line. This loop can act as
an antenna for high frequency signals which makes the
circuit sensitive to RF radiation. A better way to route the
power traces can be seen in the following setup. (see Figure
16).
The Effect of Variation For er
When using pcb material the er has a certain shift over the
used frequency spectrum, so if it is necessary to work with
very accurate trace impedances, one must take into account
the frequency region for which the design is to be functional.
Figure 14 http://www.isola.de gives an example of what the
drift in er will be when using the pcb material produced by
Isola. If working at frequencies of 100MHz then a 50Ω trace
has a width of 3.04mm for standard 1.6mm FR4 pcb material, and the same trace needs a width of 3.14mm. for
frequencies around 10GHz.
20064259
FIGURE 16.
In this arrangement the power lines have been routed in
order to avoid ground loops and to minimize sensitivity to
noise etc. The same technique is valid when routing a high
frequent signal over a board which has no ground plane. In
that case is it good practice to route the high frequency
signal alongside a ground trace. A still better way to create a
pcb carrying high frequency signals is to use a pcb with
ground a ground plane or planes.
20064257
FIGURE 14.
Routing Power Traces
Power line traces routed over a pcb should be kept together
for best practice. If not a ground loop will occur which may
cause more sensitivity to radiation. Also additional ground
trace length may lead to more ringing on digital signals.
Careful attention to power line distribution leads to improved
19
www.national.com
LMH6560
Application Notes
LMH6560
Application Notes
If the overall density becomes too high it is better to make a
design which contains additional metal layers such that the
ground planes actually function as ground planes. The costs
for such a pcb are increased but the payoff is in overall
effectiveness and ease of design.
(Continued)
Discontinuities in a Ground Plane
A ground plane with traces routed over this plane results in
the build up of an electric field between the trace and the
ground plane as seen in Figure 13. This field is build up over
the entire routing of the trace. For the highest performance
the ground plane should not be interrupted because to do so
will cause the field lines to follow a roundabout path. In
Figure 17 it was necessary to interrupt the ground plane with
the blue crossing trace. This interruption causes the return
current to follow a longer route than the signal path follows to
overcome the discontinuity.
Ground Planes at Top and Bottom Layer of a PCB
In addition to the bottom layer ground plane another useful
practice is to leave as much copper as possible at the top
layer. This is done to reduce the amount of copper to be
removed from the top layer in the chemical process. This
causes less pollution of the chemical baths allowing the
manufacturer to make more pcb’s with a certain amount of
chemicals. Connecting this upper copper to ground provides
additional shielding and signal performance is enhanced.
For lower frequencies this is specifically true. However, at
higher frequencies other effects become more and more
important such that unwanted coupling may result in a reduction in the bandwidth of a circuit. In the design of a test
circuit for the LMH6559 this effect was clearly noticeable and
the useful bandwidth was reduced from 1500MHz to around
850MHz.
20064260
FIGURE 17.
If needed it is possible to bypass the interruption with traces
that are parallel to the signal trace in order to reduce the
negative effects of the discontinuity in the ground plane. In
doing so, the current in the ground plane closely follows the
signal trace on the return path as can be seen in Figure 18.
Care must be taken not to place too many traces in the
ground plane or the ground plane effectively vanishes such
that even bypasses are unsuccessful in reducing negative
effects.
20064262
FIGURE 19.
As can be seen in Figure 19 the presence of a copper field
close to the transmission line to and from the buffer causes
unwanted coupling effects which can be seen in the dip at
about 850MHz. This dip has a depth of about 5dB for the
case when all of the unused space is filled with copper. In
case of only one area being filled with copper this dip is
about 9dB.
PCB BOARD LAYOUT AND COMPONENT SELECTION
Sound practice in the area of high frequency design requires
that both active and passive components be used for the
purposes for which they were designed. It is possible to
amplify signals at frequencies of several hundreds of MHz
using standard through hole resistors. Surface mount devices, however, are better suited for this purpose. Surface
mount resistors and capacitors are smaller and therefore
parasitics are of lower value and therefore have less influence on the properties of the amplifier. Another important
issue is the pcb itself, which is no longer a simple carrier for
all the parts and a medium to interconnect them. The pcb
board becomes a real component itself and consequently
contributes its own high frequency properties to the overall
performance of the circuit. Sound practice dictates that a
20064261
FIGURE 18.
www.national.com
20
crosstalk output signal at buffer 3, which input was terminated with a resistor of 50Ω.
Furthermore components should be placed as flat and low
as possible on the surface of the PCB. For higher frequencies a long lead can act as a coil, a capacitor or an antenna.
A pair of leads can even form a transformer. Careful design
of the pcb avoids oscillations or other unwanted behaviors.
For ultra high frequency designs only surface mount components will give acceptable results. (for more information see
OA-15).
NSC suggests the following evaluation boards as a guide for
high frequency layout and as an aid in device testing and
characterization.
(Continued)
design have at least one ground plane on a pcb which
provides a low impedance path for all decoupling capacitors
and other ground connections. Care should be taken especially that on board transmission lines have the same impedance as the cables to which they are connected - 50Ω for
most applications and 75Ω in case of video and cable TV
applications. Such transmission lines usually require much
wider traces on a standard double sided PCB board than
needed for a ’normal’ trace. Another important issue is that
inputs and outputs must not ’see’ each other. This occurs if
inputs and outputs are routed together over the pcb with only
a small amount of physical separation, particularly when
there is a high differential in signal level between them. If
routed close together crosstalk will occur and in that case a
small amount of the original signal will appear at the other
trace. The same effect will occur internally in the device. This
means that signal is jumping over from one buffer to the
other producing a part of the signal of buffer one in the other
buffers. To improve crosstalk performance it is recommended to use a grounded guard-trace between signal lines
and to ground unused pins from the device package.
Crosstalk becomes more and more noticeable for the higher
frequencies. For frequencies below 1MHz crosstalk has a
signal level as low as −70dB below the incoming signal. For
higher frequencies crosstalk will degrade until about −35dB
at 100MHz. (see typical performance characteristics) The
best way to see this, is applying a pulse to one of the buffers
and looking at the output of one of the others. The flat portion
of such a pulse represents the lowest frequencies which are
highly suppressed and the edge of the incoming pulse representing the highest frequencies will appear at the output.
For reducing the effect of crosstalk it is recommended to
terminate unused inputs and outputs with a low ohmic resistor such as 50Ω for an input or 100Ω for an output to ground.
While measuring the crosstalk, signal was applied to buffer 2
which output was terminated with 100Ω, while measuring the
Device
Package
Evaluation board
Part Number
LMH6560MA
SOIC-14
CLC730145
LMH6560MT
TSSOP-14
CLC730132
These free evaluation boards are shipped when a device
sample request is placed with National Semiconductor.
POWER SEQUENCING OF THE LMH6560
Caution should be used in applying power to the LMH6560.
When the negative power supply pin is left floating it is
recommended that other pins, such as positive supply and
signal input should also be left unconnected. If the ground is
floating while other pins are connected the input circuitry is
effectively biased to ground, with a mostly low ohmic resistor, while the positive power supply is capable of delivering
significant current through the circuit. This causes a high
input bias current to flow which degrades the input junction.
The result is an input bias current which is out of specification. When using inductive relays in an application care
should be taken to connect first both power connections
before connecting the bias resistor to the input.
21
www.national.com
LMH6560
Application Notes
LMH6560
Physical Dimensions
inches (millimeters)
unless otherwise noted
14-Pin SOIC
NS Package Number M14A
14-Pin TSSOP
NS Package Number MTC14
www.national.com
22
LMH6560 Quad, High-Speed, Closed-Loop Buffer
Notes
National does not assume any responsibility for use of any circuitry described, no circuit patent licenses are implied and National reserves
the right at any time without notice to change said circuitry and specifications.
For the most current product information visit us at www.national.com.
LIFE SUPPORT POLICY
NATIONAL’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS
WITHOUT THE EXPRESS WRITTEN APPROVAL OF THE PRESIDENT AND GENERAL COUNSEL OF NATIONAL SEMICONDUCTOR
CORPORATION. As used herein:
1. Life support devices or systems are devices or systems
which, (a) are intended for surgical implant into the body, or
(b) support or sustain life, and whose failure to perform when
properly used in accordance with instructions for use
provided in the labeling, can be reasonably expected to result
in a significant injury to the user.
2. A critical component is any component of a life support
device or system whose failure to perform can be reasonably
expected to cause the failure of the life support device or
system, or to affect its safety or effectiveness.
BANNED SUBSTANCE COMPLIANCE
National Semiconductor certifies that the products and packing materials meet the provisions of the Customer Products Stewardship
Specification (CSP-9-111C2) and the Banned Substances and Materials of Interest Specification (CSP-9-111S2) and contain no ‘‘Banned
Substances’’ as defined in CSP-9-111S2.
National Semiconductor
Americas Customer
Support Center
Email: [email protected]
Tel: 1-800-272-9959
www.national.com
National Semiconductor
Europe Customer Support Center
Fax: +49 (0) 180-530 85 86
Email: [email protected]
Deutsch Tel: +49 (0) 69 9508 6208
English Tel: +44 (0) 870 24 0 2171
Français Tel: +33 (0) 1 41 91 8790
National Semiconductor
Asia Pacific Customer
Support Center
Email: [email protected]
National Semiconductor
Japan Customer Support Center
Fax: 81-3-5639-7507
Email: [email protected]
Tel: 81-3-5639-7560
Similar pages