Meder HM12-1A69-150 Hm reed relay Datasheet

Europe: +49 / 7731 8399 0
| Email: [email protected]
Item No.:
USA:
+1 / 508 295 0771
| Email: [email protected]
Asia:
+852 / 2955 1682
| Email: [email protected]
8412169150
Item:
HM12-1A69-150
Conditions
Coil Data at 20 °C
Coil resistance
Coil voltage
Rated power
Thermal resistance
Pull-In voltage
Drop-Out voltage
=
Contact rating
Switching voltage
Switching current
Carry current
Contact resistance static
Insulation resistance
Breakdown voltage
Operate time incl. bounce
Release time
Capacitance
Special Product Data
Number of contacts
Contact - form
Dielectric Strength Coil/Contact
Insulation resistance Coil/Contact
Case colour
Housing material
Sealing compound
Connection pins
Reach / RoHS conformity
Typ
Max
Unit
Min
Typ
Max
Unit
operating temperature + self heating
Conditions
Contact data 69
Min
! "# #! !$ %
not to exceed their individual max.'s
DC or Peak AC
DC or Peak AC
DC or Peak AC
& ' ( )#
Start Value
* !+ ( #+
RH <45 %, 100 V test voltage
according to IEC 255-5
measured with 40% overdrive
measured with no coil excitation
@ 10 kHz across open switch
,
.
'
'
/
Max
Unit
.0
Conditions
Min
Typ
1
A - NO
according to IEC 255-5
RH <45%, 200 VDC test voltage
,
gray
Polycarbonat
Polyurethan
Copper alloy tin plated
yes
Modifications in the sense of technical progress are reserved
Designed at:
21.03.03
Designed by:
EBUNKE
Approval at:
06.05.08
Approval by:
DSTASTNY
Last Change at:
19.04.11
Last Change by:
WKOVACS
Approval at:
19.04.11
Approval by:
CRUF
Version:
08
Europe: +49 / 7731 8399 0
| Email: [email protected]
Item No.:
USA:
+1 / 508 295 0771
| Email: [email protected]
Asia:
+852 / 2955 1682
| Email: [email protected]
8412169150
Item:
HM12-1A69-150
Environmental data
Shock
Vibration
Operating temperature
Storage temperature
Soldering temperature
Washability
Conditions
Min
4
4
wave soldering max. 5 sec.
Max
3
0
Unit
1
1
2
2
2
fully sealed
Conditions
General data
Typ
1/2 sine wave duration 11ms
from 10 - 2000 Hz
Min
Total weigth
Packaging
Typ
Max
carton palete a 10 pcs.
Unit
1
Modifications in the sense of technical progress are reserved
Designed at:
21.03.03
Designed by:
EBUNKE
Approval at:
06.05.08
Approval by:
DSTASTNY
Last Change at:
19.04.11
Last Change by:
WKOVACS
Approval at:
19.04.11
Approval by:
CRUF
Version:
08
Similar pages