MPS MBU30-110 30w open frame switching power supplies for medical equipment Datasheet

MBU30 SERIES
30W Open Frame Switching Power Supplies For Medical Equipment.
Description:
The MBU30 series of compact, open frame constructed, AC/DC
switching mode power supplies provide 30 Watts of continuous output
power .They are suited for use in hospital instrument and many other
applications. All models meet FCC Part-18 class B and CISPR-11
EN55011 class B emission Limits and are designed to comply with
UL/c-UL(UL 60601-1:2ndEdition) ,TUV/T-mark(EN 60601-1:2ndEdition)
and new CE requirements. All units are 100% burned in and tested.
Features:
Wide Operating Voltage 90 to 264 VAC,47 to 63 Hz
Internal EMI filter
Single Output
Input connector mates with Molex housing 09-50-3031
and Molex 2478 series crimp terminal
Output connector mates with Molex housing 09-50-3061
and Molex 2478 series crimp terminal
Input Surge Current, Over Voltage and Over Load protection
Output Voltage Protection(Crowbar Design)
Size: 2"x4"
Class I
3 year warranty
Safety Approvals :
EN 60601-1
IEC 60601-1
Electrical Characteristics:
Sym.
Parameter
Vin
Safety Approvals Input
Voltage Range
fin
Po
Vo
Io
Iil
Iih
Operate Voltage Range
Input Frequency
Output Power Range
Output Voltage Range
Output Current Range
Input Current (Low Line)
Input Current (High Line)
I rl
Low Line Inrush Current
I rh
High Line Inrush Current
Eff
REG-i
REG -o
OVP
OCP
Ttr
Thold
Ts
Vp-p
Ilk
TC
Efficiency
Line Regulation
Load Regulation
Over Voltage Protection
Over Current Protection
Time of Transient Response
Hold-Up Time
Start Up Time
Ripple & Noise (Peak to Peak)
Safety Ground Leakage Current
Temperature Coefficient
Test Conditions
Min. Typ. Max. Unit
100
Vin=90 to 264 VAC
Io=Full load,
Io=Full load,
Io=Full load,
Vin=115VAC
Io=Full load,
Vin=230VAC
Io=Full load,
Io=Full load
Vin=230VAC
Vin=115VAC
Vin=230VAC
25 C,Cool start,
VAC
264
90
47
63
30
0
See rating Chart
See rating Chart
0.7
0.3
0.5
VAC
Hz
W
V
A
A
A
15
18
A
21
25
A
80
0.5
3
85
1
7
132
150
4
%
%
%
%
%
mS
mS
S
%
mA
%/ C
25 C,Cool start,
Vin=230VAC
240
70
112
110
Io=Full load to Half Load, Vin=100VAC
10
12
Io=Full load, Vin=110VAC
Io=Full load, Vin=100VAC
1
2
0.3
Full load, Vin=90VAC
0.5
1
Io=Full load, Vin=240VAC
0.1 0.3
All output
-0.04
0.04
Environmental :
Sym.
Parameter
T e s t Conditions
Min. Typ. Max.
Unit
50
70
C
Toper
Operating Temperature
Tstg
Storage Temperature
-40
85
C
Ho
Operating Humidity
0
95
%
Hr
Storage Humidity
0
75
%
MTBF
Operating Temperature at 25 C, Calculated per MIL-HDBK-217F
Pd
Derate linearly from 100% load at 50 C to 50% load at 70 C
0
0.1M
Hrs
MBU30 SERIES
30W Open Frame Switching Power Supplies For Medical Equipment.
Safety Specifications:
Sym.
Parameter
Min. Typ. Max.
Unit
Primary to secondary
5656
VDC
Primary to ground
2828
VDC
50
B
B
M
CLASS
CLASS
1
T e s t Conditions ○
Dielectric Withstanding Voltage
Vps for
Primary to secondary
Dielectric Withstanding Voltage
Vpg for Primary to Ground
Ris Isolation Resistance
CISPR EMI requirements for CISPR-11
FCC EMI requirements for FCC PART-18
Test Voltage=500VDC
Vin=220VAC
Vin=110VAC
1 Recommend to be used on the metal chassis.
○
Output Voltage And Current Rating Chart (Single Output) :
Model Number
Output Voltage
Output Current
Total
Regulation
Maximum
Output Power
MBU30-102
5
VDC
6.00 A
5%
30W
MBU30-103
7
VDC
4.28 A
5%
30W
MBU30-104
9
VDC
3.33 A
5%
30W
MBU30-105
12
VDC
2.50 A
5%
30W
MBU30-106
15
VDC
2.00 A
5%
30W
MBU30-107
18
VDC
1.66 A
5%
30W
MBU30-108
24
VDC
1.25 A
5%
30W
MBU30-109
30
VDC
1.00 A
5%
30W
MBU30-110
36
VDC
0.83 A
3%
30W
Mechanical Specifications :
PIN CHART
PIN 1
2
3
4
5
6
MODEL
MBU30-1XX
RTN RTN RTN Vout Vout Vout
Note:
1. Dimensions are shown in inches or mm.
2. Weight: 200gs approx.
3. Input connector mates with Molex housing 09-50-3031
and Molex 2478 series crimp terminal.
4. Output connector mates with Molex housing 09-50-3061
and Molex 2478 series crimp terminal.
Similar pages