ETC2 MGDS-04-J-CT Hi-rel dc/dc converter Datasheet

Hi-Rel DC/DC CONVERTER
MGDM-04 : 4W POWER
Hi-Rel
Grade
Single, Bi & Triple Outputs
Metallic Case - 1.500 VDC Isolation
• 28 Vdc input compliant with MIL-STD-704 D/E
• Low profile : 0,3‘’ (7.5mm)
• Nominal power of 4W without derating
• Wide temperature range : -40°C/+105°C case
• Soft start
• Galvanic isolation 1.500 VDC
• Integrated LC EMI filter
1-General
• Permanent short circuit protection
• Standard pin out DIL24 9 pins
• Inhibit function
• No optocoupler for high reliability
The MGDM-04 series is a full family of high performance and low profile DC/DC power modules
designed for aerospace, military and high-end
industrial applications. These modules use a high
frequency fixed switching technic at 480KHz
providing excellent reliability, low noise
characteristics, high power density and a low profile package. Standard models are available with
nominal input voltages as 5, 12 or 28 volts in
range of 4,5-5,5 , 9-36 or 16-40 volts. The series
include single, bi and triple output voltage choices
of 3.3, 5, 12, 15, +/-5, +/-12 or +/-15 volts. No
external heatsink is required for the MGDM-04
series to supply 4W output power over the case
temperature range of -40°C up to 105°C.
All the modules are designed with LC network
filters to minimize reflected input current ripple
and output voltage ripple.
The modules include a soft-start, a permanent
short circuit protection and an output overvoltage
protection to ensure efficient module protections.
The soft-start allows current limitation and
eliminates inrush current during start-up. The
short circuit protection completely protects the
module against short-circuits of any duration by
a shut-down and restores to normal when the
overload is removed.
The design has been carried out with surface
mount components and is manufactured in a fully
automated process to guarantee high quality. Each
module is tested and burned in with a GAIA
Converter automated test equipment before and
after encapsulation. The modules are potted with
a bi-component thermal conductive compound and
packaged in a metallic case to ensure the module’s
integrity under high environmental conditions.
2-Product Selection
Single output model
: MGDS-04-
(/T) and/or (/S)
Bi output model
: MGDB-04-
(/T) and/or (/S)
Triple output model
: MGDT-04-
(/T) and/or (/S)
(/T) : option for -55°C start up operating temperature.
(/S) : option for screening and serialization
Input Voltage Range
Permanent
Transient
C : 4,5-5,5 VDC
H : 9-36 VDC
J : 16-40 VDC
n/a
40 VDC/100 ms*
50 VDC/100 ms*
Output
B : 3.3 VDC
C : 5 VDC or +/-5VDC
E : 12 VDC or +/-12VDC
F : 15 VDC or +/-15VDC
CF : 5 VDC and +/-15 VDC
* Consult factory for details
REDEFINING THE SOURCE OF POWER
© Gaia Converter FC97-008.08/06 Revision N
For locations, phone, fax, E-Mail see back cover
4
Hi-Rel
Grade
MGDM-04 Series
2- Product Selection (continued)
Input range
4,5-5,5
4,5-5,5
4,5-5,5
4,5-5,5
4,5-5,5
4,5-5,5
4,5-5,5
VDC
VDC
VDC
VDC
VDC
VDC
VDC
Output
Current
Reference
Options
3,3 VDC
5 VDC
12 VDC
15 VDC
+/- 5 VDC
+/- 12 VDC
+/- 15 VDC
1A
800 mA
330 mA
260 mA
+/- 400 mA
+/- 165 mA
+/- 130 mA
MGDS-04-C-B
MGDS-04-C-C
MGDS-04-C-E
MGDS-04-C-F
MGDB-04-C-C
MGDB-04-C-E
MGDB-04-C-F
/T
/T
/T
/T
/T
/T
/T
,
,
,
,
,
,
,
/S
/S
/S
/S
/S
/S
/S
9-36
9-36
9-36
9-36
9-36
9-36
9-36
VDC
VDC
VDC
VDC
VDC
VDC
VDC
3,3 VDC
5 VDC
12 VDC
15 VDC
+/- 5 VDC
+/- 12 VDC
+/- 15 VDC
1A
800 mA
330 mA
260 mA
+/- 400 mA
+/- 165 mA
+/- 130 mA
MGDS-04-H-B
MGDS-04-H-C
MGDS-04-H-E
MGDS-04-H-F
MGDB-04-H-C
MGDB-04-H-E
MGDB-04-H-F
/T
/T
/T
/T
/T
/T
/T
,
,
,
,
,
,
,
/S
/S
/S
/S
/S
/S
/S
16-40
16-40
16-40
16-40
16-40
16-40
16-40
16-40
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
3,3 VDC
5 VDC
12 VDC
15 VDC
+/- 5 VDC
+/- 12 VDC
+/- 15 VDC
5 & +/-15 VDC
1A
800 mA
330 mA
260 mA
+/- 400 mA
+/- 165 mA
+/- 130 mA
500 & +/-50 mA
MGDS-04-J-B
MGDS-04-J-C
MGDS-04-J-E
MGDS-04-J-F
MGDB-04-J-C
MGDB-04-J-E
MGDB-04-J-F
MGDT-04-J-CF
/T
/T
/T
/T
/T
/T
/T
/T
,
,
,
,
,
,
,
,
/S
/S
/S
/S
/S
/S
/S
/S
4
Converter Selection Chart
MGDS
- 04 - J - C / T
Number of Outputs :
S : single output
B : bi ouput
T : triple output
Input voltage range :
C : 4,5-5,5 VDC
H : 9-36 VDC
J : 16-40 VDC
Output voltage :
See table page 1
Option :
/T : -55°C start up operation
/S : screening and
serialization
(consult
application note «screening
grades»)
© Gaia Converter FC97-008.08/06 Revision N
2
For locations, phone, fax, E-Mail see back cover
MGDM-04 Series
Hi-Rel
Grade
3- Electrical Specifications
Data are valid at +25°C, unless otherwise specified.
Parameter
Input
Nominal input voltage
Permanent input
voltage range (Ui)
Transient input voltage
Start up input voltage
Start up time
Reflected ripple current
Input current in short
circuit mode (Average)
No load input current
Input current in inhibit
mode
Output
Output voltage
Set Point accuracy
Output power
Output current
3,3V output
5V output
12V output
15V output
Ripple output voltage *
3,3V and 5V output
12V output
15V output
Line regulation
Load regulation **
Efficiency
Maximum admissible
Capacity load
3,3V and 5V output
12V and 15V output
Conditions
Limit or
typical
Units
Full temperature range
Nominal
Full temperature range
Single Output MGDS-04
04 - C
04 - H
04 - J
VDC
5
20
28
Min. - Max.
VDC
4,5-5,5
9-36
16-40
Full load (consult factory)
Full load
Ui nominal
Nominal output
Full load : resistive
Ui nominal, full load at
switching freq. BW = 20MHz
Ui nominal
Short-circuit
Ui nominal
No load
Maximum
Minimum
VDC/S
VDC
/
4,3
40/0,1
8,5
50/0,1
15,5
Maximum
ms
200
200
200
Maximum
mApp
50
50
30
Maximum
mA
50
30
30
Maximum
mA
50
30
30
inhibit
Maximum
mA
5
5
5
Full temperature range
Ui min. to max.
75% load
Nominal
Nominal
Nominal
Nominal
VDC
VDC
VDC
VDC
3,3
5
12
15
3,3
5
12
15
3,3
5
12
15
Maximum
%
+/- 2
+/- 2
+/- 2
Maximum
W
4
4
4
Full temperature range
Ui min. to max.
Maximum
Maximum
Maximum
Maximum
mA
mA
mA
mA
1.000
800
330
260
1.000
800
330
260
1.000
800
330
260
Ui nominal
Full load
BW = 20MHz
Maximum
Maximum
Maximum
mVpp
mVpp
mVpp
40
50
60
40
50
60
40
50
60
Maximum
%
+/- 0,5
+/- 0,5
+/- 0,5
Maximum
%
+/- 2
+/- 2
+/- 2
Typical
%
Maximum
Maximum
µF
µF
Ambient temperature : +25°c
Ui nominal, 75% load
Full temperature range
Ui min. to max.
Ui min. to max.
Full load
Ui nominal
25% to full load
Ui nominal
Full load
Ui nominal
Full load
Per output
4
see on page 6
1.000
47
1.000
47
1.000
47
Note * : The ripple output voltage is the periodic AC component imposed on the output voltage, an aperiodic and random component (noise) has also to be considered. This
noise can be reduced by adding an external capacitor (typically 10nF/rated voltage depending on isolation requirement) connected between the pin Gin and the pin Gout
of the converter. This capacitor should be layed-out as close as possible from the converter.
Note ** : For load regulation characteristics from 0% to full load, please see page 6.
© Gaia Converter FC97-008.08/06 Revision N
3
For locations, phone, fax, E-Mail see back cover
MGDM-04 Series
Hi-Rel
Grade
3- Electrical Specifications (continued)
Data are valid at +25°C, unless otherwise specified.
Parameter
Input
Nominal input voltage
Permanent input
voltage range (Ui)
Transient input voltage
Start up input voltage
Start up time
Reflected ripple current
Input current in short
circuit mode (Average)
No load input current
Input current in inhibit
mode
Output
Output voltage
Set Point accuracy
Output power
Output current
+/- 5V output
+/- 12V output
+/- 15V output
Ripple output voltage *
5V output
12V output
15V output
Line regulation
Load regulation **
Cross load output
regulation
Efficiency
Maximum admissible
Capacity load
5V output
12V and 15V output
Conditions
Limit or
typical
Units
Full temperature range
Nominal
Full temperature range
Bi Output MGDB-04
04 - C
04 - H
04 - J
VDC
5
20
28
Min. - Max.
VDC
4,5-5,5
9-36
16-40
Full load (consult factory)
Full load
Ui nominal
Nominal output
Full load : resistive
Ui nominal, full load at
switching freq. BW = 20MHz
Ui nominal
Short-circuit
Ui nominal
No load
Maximum
Minimum
VDC/S
VDC
/
4,3
40/0,1
8,5
50/0,1
15,5
Maximum
ms
200
200
200
Maximum
mApp
50
50
30
Maximum
mA
50
30
30
Maximum
mA
50
30
30
inhibit
Maximum
mA
5
5
5
Full temperature range
Ui min. to max.
75% load
Ambient temperature : +25°c
Ui nominal, 75% load
Full temperature range
Ui min. to max.
Nominal
Nominal
Nominal
VDC
VDC
VDC
+/- 5
+/- 12
+/- 15
+/- 5
+/- 12
+/- 15
+/- 5
+/- 12
+/- 15
Maximum
%
+/- 2
+/- 2
+/- 2
Maximum
W
+/- 2
+/- 2
+/- 2
Full temperature range
Ui min. to max.
Maximum
Maximum
Maximum
mA
mA
mA
+/- 400
+/- 165
+/- 130
+/- 400
+/- 165
+/- 130
+/- 400
+/- 165
+/- 130
Ui nominal
Full load
BW = 20MHz
Maximum
Maximum
Maximum
mVpp
mVpp
mVpp
40
50
60
40
50
60
40
50
60
Maximum
%
+/- 0,5
+/- 0,5
+/- 0,5
Maximum
%
+/- 2
+/- 2
+/- 2
Maximum
%
+/- 0,5
+/- 0,5
+/- 0,5
Typical
%
Maximum
Maximum
µF
µF
Ui min. to max.
Full load
Ui nominal
25% to full load
Ui nominal
+ Vout nominal load
- Vout from 25% to full load
Ui nominal
Full load
Ui nominal
Full load
Per output
4
see on page 6
470
22
470
22
470
22
Note * : The ripple output voltage is the periodic AC component imposed on the output voltage, an aperiodic and random component (noise) has also to be considered. This
noise can be reduced by adding an external capacitor (typically 10nF/rated voltage depending on isolation requirement) connected between the pin Gin and the pin Gout
of the converter. This capacitor should be layed-out as close as possible from the converter.
Note ** : For load regulation characteristics from 0% to full load, please see page 6.
© Gaia Converter FC97-008.08/06 Revision N
4
For locations, phone, fax, E-Mail see back cover
Hi-Rel
Grade
MGDM-04 Series
3- Electrical Specifications (continued)
Data are valid at +25°C, unless otherwise specified.
Parameter
Input
Nominal input voltage
Permanent input
voltage range (Ui)
Transient input voltage
Start up input voltage
Triple Output
Conditions
Limit or
typical
Units
Full temperature range
Nominal
VDC
28
Full temperature range
Min. - Max.
VDC
16-40
Maximum
Minimum
VDC/S
VDC
50/0,1
15,5
Maximum
ms
200
Maximum
mApp
30
Maximum
mA
30
Maximum
mA
30
Maximum
mA
5
Nominal
VDC
5 & +/- 15
Maximum
%
+/- 2
Maximum
W
2 & +/- 1
Maximum
mA
500 & +/- 50
Maximum
Maximum
mVpp
mVpp
Full load (consult factory)
Full load
Ui nominal
Start up time
Nominal output
Full load : resistive
Ui nominal, full load at switching
Reflected ripple current
freq. BW = 20MHz
Input current in short circuit Ui nominal
mode (Average)
Short-circuit
Ui nominal
No load input current
No load
Input current in inhibit
inhibit
mode
Output
Full temperature range
Output voltage
Ui min. to max.
75% load
Ambient temperature : +25°c
Set Point accuracy
Ui nominal, 75% load
Full temperature range
Output power
Ui min. to max.
MGDT-04- J
Output current
5V & +/- 15V output
Full temperature range
Ui min. to max.
Ripple output voltage *
5V output
15V output
Ui nominal
Full load
BW = 20MHz
Ui min. to max.
Full load
Ui nominal
25% to full load
Ui nominal
+ Vout nominal load
- Vout from 25% to full load
Ui nominal
Full load
Maximum
%
+/- 0,5
Maximum
%
+/- 2
Maximum
%
+/- 0,5
Typical
%
80
Ui nominal
Full load
Per output
Maximum
Maximum
µF
µF
220
47
Line regulation
Load regulation **
Cross load output regulation
Efficiency
Maximum admissible
Capacity load
5V output
15V output
4
40
60
Note * : The ripple output voltage is the periodic AC component imposed on the output voltage, an aperiodic and random component (noise) has also to be considered. This
noise can be reduced by adding an external capacitor (typically 10nF/rated voltage depending on isolation requirement) connected between the pin Gin and the pin Gout
of the converter. This capacitor should be layed-out as close as possible from the converter.
Note ** : For load regulation characteristics from 0% to full load, please see page 6.
© Gaia Converter FC97-008.08/06 Revision N
5
For locations, phone, fax, E-Mail see back cover
Hi-Rel
Grade
MGDM-04 Series
3- Electrical Characteristics (continued)
Figure 2 : Typical efficiency versus load
at nominal input
83
80
80
80
77
77
77
74
71
input 5V
74
71
2
3
Output Power (W)
4
2
3
Output Power (W)
4
1
80
80
80
77
77
input 9V
input 18V
71
Efficiency (%)
83
Efficiency (%)
83
74
74
input 18V
71
3
Output Power (W)
80
81
Efficiency (%)
84
input 40V
input 16V
3
1
4
2
3
Output Power (W)
(MGDS-04-H-C module)
Figure 8 : Typical efficiency versus load
at various input
83
77
2
Output Power (W)
(MGDS-04-H-B module)
Figure 7 : Typical efficiency versus load
at various input
71
71
65
1
4
4
4
(MGDS-04-H-E module)
Figure 9 : Typical efficiency versus load
at various input
84
81
input 40V
78
Efficiency (%)
2
74
input 18V
input 36V
65
65
1
input 9V
74
68
68
68
4
(MGDS-04-C-F module)
77
input 36V
input 36V
3
Figure 6 : Typical efficiency versus load
at nominal input
83
input 9V
2
Output Power (W)
(MGDS-04-C-E module)
Figure 5 : Typical efficiency versus load
at various input
Figure 4 : Typical efficiency versus
load at various input
input 5V
71
65
1
(MGDS-04-C-C module)
74
68
65
1
input 28V
75
input 16V
72
78
input 40V
75
input 28V
72
input 28V
69
68
66
65
1
2
3
Output Power (W)
66
1
4
2
3
Output Power (W)
(MGDS-04-J-C module)
Figure 10 : Typical load regulation
characteristics at nominal input
4
1
16,4
13,2
16,2
Output voltage (VDC)
13,4
5,5
5,2
5,1
5
13
12,8
12,6
12,4
12,2
100
200
300
400
500
Output Current (mA)
© Gaia Converter FC97-008.08/06 Revision N
600
700
800
(MGDS-04-J-C module)
16
15,8
15,6
15,4
15,2
14,8
11,8
0
4
(MGDS-04-J-F module)
15
12
4,9
3
Figure 12 : Typical load regulation
characteristics at nominal input
5,6
5,3
2
Output Power (W)
(MGDS-04-J-E module)
Figure 11 : Typical load regulation
characteristics at nominal input
5,4
input 16V
69
Output voltage (VDC)
Efficiency (%)
input 5V
68
65
Efficiency (%)
Efficiency (%)
83
68
Output voltage (VDC)
Figure 3 : Typical efficiency versus load
at nominal input
83
Efficiency (%)
Efficiency (%)
Figure 1 : Typical efficiency versus load
at nominal input
0
50
100
150
Output Current (mA)
200
250
300
350
(MGDS-04-J-E module)
0
50
100
Output Current (mA)
150
200
250
300
(MGDS-04-J-F module)
6
For locations, phone, fax, E-Mail see back cover
Hi-Rel
Grade
MGDM-04 Series
4- Switching Frequency
Parameter
Conditions
Limit or typical
Specifications
Switching frequency
Full temperature range
Ui min. to max.
No load to full load
Nominal, fixed
480 KHz for single & bi
output models
400 KHz for triple output
models
Parameter
Conditions
Limit or typical
Specifications
Electric strength test voltage
Input to output
Minimum
1.500 VDC / 1 min
Electric strength test voltage between
outputs (for dual and triple outputs)
Output to output
Minimum
No isolation
Isolation resistance
500 VDC
Minimum
100 MOhm
5- Isolation
6- Protection Functions
Characteristics
Protection Device
Recovery
Limit or typical
Specifications
Output short circuit protection (SCP)
Hiccup circuitry with
auto-recovery
Automatic
recovery
Permanent
See section 11
/
Maximum
Maximum
Maximum
Maximum
For 3.3v : 4v
For 5v : 6v
For 12v : 14v
For 15v : 17v
Output overvoltage protection (OVP)
Zener clamp
4
7- Reliability Data
Characteristics
Mean Time Between Failure (MTBF)
According to MIL-HDBK-217F
Mean Time Between Failure (MTBF)
According to IEC-62380-TR
© Gaia Converter FC97-008.08/06 Revision N
Conditions
Temperature
Specifications
Ground fixed (Gf)
Case at 40°C
Case at 85°C
1.650.000 Hrs
645.000 Hrs
Airborne, Inhabited,
Cargo (AIC)
Case at 40°C
Case at 85°C
900.000 Hrs
350.000 Hrs
Avionics Military Cargo
/
Consult factory
7
For locations, phone, fax, E-Mail see back cover
MGDM-04 Series
Hi-Rel
Grade
8- Electromagnetic Interference
Electromagnetic Interference requirements according to MIL-STD-461C/D/E standards can be easily achieved as indicated in
the following section. The following table resumes the different sections covered by these standards.
MIL-STD-461C
Standard
MIL-STD-461D/E
Standard
Conducted emission (CE) :
Low frequency
High frequency
CE 01
CE 03
CE 101
CE 102
compliant module stand-alone
compliant with additionnal filter
Conducted susceptibility (CS) :
Low frequency
High frequency
CS 01
CS 02
CS 101
CS114
compliant with additionnal filter
compliant with additionnal filter
Radiated emission (RE) :
Magnetic field
Electrical field
RE 01
RE 02
RE 101
RE 102
compliant module stand-alone
compliant module stand-alone
Radiated susceptibility (RS) :
Magnetic field
Electrical field
RS 01
RS 03
RS 101
RS 103
compliant module stand-alone
compliant module stand-alone
Standard Requirements
Applicability
H, J input module
Compliance with GAIA Converter
Module & common mode capacitance
H, J input module
see EMI datasheet
4
8-1 Module Compliance with MIL-STD-461C/D/E Standards
To meet the latest US military standards MIL-STD-461D/E (and also the MIL-STD-461C) requirements and in particular the
conducted noise emission CE102 (and also CE03) requirements, Gaïa Converter can propose a stand-alone ready-to-use EMI
filter module. This EMI filter module has to be used together with a common mode noise capacitance C c (10nF/rated voltage
depending on isolation requirement) connected between Gin and Gout.
EMI Filter module reference : FGDM-2A-50V.
Please consult EMI filter datasheet for further details.
VI
Vo
EMI input Filter
GI
Go
Vo
VI
MGDM-series
GI
Go
Cc
© Gaia Converter FC97-008.08/06 Revision N
8
For locations, phone, fax, E-Mail see back cover
MGDM-04 Series
Hi-Rel
Grade
9- Thermal Characteristics
Conditions
Limit or typical
Performances
Operating ambient temperature
range at full load
Characteristics
Ambient temperature *
Minimum
Maximum
- 40°C
+ 85°C
Operating case temperature
range at full load
Case temperature
Minimum
Maximum
- 40°C
+105°C
Storage temperature range
Non functionning
Minimum
Maximum
- 55°C
+ 125°C
Thermal resistance
Rth case to ambient in free air
natural convection
Typical
20°C /W
Note * : The upper temperature range depends on configuration, the user must assure a max. case temperature of + 105°C.
The MGDM-04 series operating case temperature must not exceed 105°C. The maximum ambient temperature admissible
for the DC/DC converter corresponding to the maximum operating case temperature of 105°C depends on the ambient
airflow, the mounting/orientation, the cooling features and the power dissipated.
To calculate a maximum admissible ambient temperature the following method can be used. Knowing the maximum case
temparature Tcase = 105°C of the module, the power used Pout and the efficiency h:
• determine the power dissipated by the module Pdiss that should be evacuated :
h - 1)
Pdiss = Pout(1/h
• determine the maximum ambient temperature :
Ta = 105°C - Rth x Pdiss
where Rth is the thermal resistance from the case to ambient.
4
The previous thermal calculation shows two areas of operation :
• a normal operation area in a free natural ambient convection (grey area in this following graph),
• an area with cooling features (air flow or heatsink) ensuring a maximum case temperature below the maximum
operating case temperature of 105°C (white area in the following graph).
Power (W)
100%
Additionnal cooling operation area
75%
50%
Natural convection operation area
25%
10
20
30
40
50
60
70
80
90
100 110
Temperature (˚C)
Full load ambient temperature without derating : 85˚C
Maximum case temperature : 105˚C
Maximum storage temperature : 125˚C
© Gaia Converter FC97-008.08/06 Revision N
9
For locations, phone, fax, E-Mail see back cover
MGDM-04 Series
Hi-Rel
Grade
10- Environmental Qualifications
The modules have been subjected to the following environmental qualifications.
Characteristics
Conditions
Severity
Test procedure
Duration
Temperature / status of unit
Test D : 1.000 Hrs
@ 105°C case, unit operating
@ 125°C ambient, unit not operating
MIL-STD-202G
Method 108A
Altitude
Altitude level C
Duration
Climb up
Stabilization
Status of unit
40.000 ft@-55°C
30 min.
1.000 ft/min to 70.000 f@-55°C,
30 min.
unit operating
MIL-STD-810E
Method 500.3
Humidity cyclic
Number of cycle
Cycle duration
Relative humidity variation
Temperature variation
Status of unit
10
Cycle I : 24 Hrs
60 % to 88 %
31°C to 41°C
unit not operating
MIL-STD-810E
Method 507.3
Humidity steady
Damp heat
Temperature
Duration
Status of unit
93 % relative humidity
40°C
56 days
unit not operating
MIL-STD-202G
Method 103B
Salt atmosphere
Temperature
Concentration NaCl
Duration
Status of unit
35°C
5%
48 Hrs
unit not operating
MIL-STD-810E
Method 509.3
Temperature
cycling
Number of cycles
Temperature change
Transfert time
Steady state time
Status of unit
200
-40°C / +85°C
40 min.
20 min.
unit operating
MIL-STD-202A
Method 102A
Temperature shock
Number of shocks
Temperature change
Transfert time
Steady state time
Status of unit
100
-55°C / +105°C
10 sec.
20 min.
unit not operating
MIL-STD-202G
Method 107G
Climatic Qualifications
Life at high
temperature
4
Mechanical Qualifications
Vibration
(Sinusoidal)
Number of cycles
Frequency / amplitude
Frequency / acceleration
Duration
Status of unit
10 cycles in each axis
10 to 60 Hz / 0.7 mm
60 to 2000 Hz / 10 g
2h 30 min. per axis
unit not operating
MIL-STD-810D
Method 514.3
Shock
(Half sinus)
Number of shocks
Peak acceleration
Duration
Shock form
Status of unit
3 shocks in each axis
100 g
6 ms
1/2 sinusoidal
unit not operating
MIL-STD-810D
Method 516.3
Bump
(Half sinus)
Number of bumps
Peak acceleration
Duration
Status of unit
2000 bumps in each axis
40 g
6 ms
unit not operating
MIL-STD-810D
Method 516.3
© Gaia Converter FC97-008.08/06 Revision N
10
For locations, phone, fax, E-Mail see back cover
Hi-Rel
Grade
MGDM-04 Series
11- Description of Protections
11-1 Output Short Circuit Protection (SCP)
The short circuit protection device protects the module
against short circuit of any duration and restores the module to normal operation when the short circuit is removed.
It operates in «hiccup» mode by testing periodically if an
overload is applied (typically every 200ms recovery time).
The overload detection threshold is typically 200% of maximum current with a detection time lower than 5ms.
Vo (%)
100
detection time
x
time
recovery time
recovery time
11-2 Output Overvoltage Protection (OVP)
The output overvoltage protection device protects external
components against high voltage or possible overvoltages
which can be supplied by the module (i.e in case of internal
failure). It consists of a zener diode clamping the output
voltage; under worst case conditions this zener diode will
short-circuit.
The output voltage protection is not designed to withstand
externally applied output overvoltages to protect the module itself.
4
12- Description of Functions
12-1 On/Off Function
The control pin 20 (On/Off) can be used for applications
requiring On/Off operation. By using an open collector
command with a transistor Q referenced to the common
terminal (Gi) :
• A logic pulled low (<0.2V@1mA, referenced to Gi)
on pin 20 disables the converter
• No connection or high impedance on pin 20 enables
the converter.
On/Off
Command
By releasing the On/Off function, the converter will restart
within the start-up time specifications given in table page 3.
For further details please consult ‘’Logic On/Off’’ Application Note.
© Gaia Converter FC97-008.08/06 Revision N
GI
11
For locations, phone, fax, E-Mail see back cover
MGDM-04 Series
Hi-Rel
Grade
13- Application Notes
13-1 Connection of Outputs in Series
Any of the bi output converters can be configured to produce
an output of 10V (+/-5 output models), 24V (+/-12V output models), or 30V (+/-15V output models) by connecting
the load across the output (+) and the output (-) with
either output grounded, and leaving the common pin
floating.
VI
+Vo
Go
GI
-Vo
VI
Vo
GI
Go
2 x Vo
13-2 Connection of Modules in Series
The output of single output units can be connected in
series without any precautions to provide higher output
voltage level.
Nevertheless, GAIA Converter recommends to protect each
individual output by a low power shottky diode rated with
the maximum current of the converter to avoid reverse
polarity at any output.
Reverse polarity may occur at start up if the output voltages do not rise at the same time.
2 x Vo
VI
Vo
4
GI
Go
VI
Vo
13-3 Connection of Modules in Parallel
Several converters with equal output voltage can be
connected in parallel to increase power. Nevertheless some
cares have to be taken in particular as the output voltage
of each converter is slightly different, when paralleling,
the converter with the highest output voltage will source
the most current.
However the GAIA Converter modules are designed with a
“soft’’ output voltage versus current characteristic. This
causes the output voltage of each converter to automatically
adjust downward as its current increases so each converter
very approximately shares the total output current. It is
important that each converter has approximately the same
impedance between their output and the common load.
© Gaia Converter FC97-008.08/06 Revision N
Vo
GI
Go
VI
Vo
GI
Go
12
For locations, phone, fax, E-Mail see back cover
MGDM-04 Series
Hi-Rel
Grade
14- Dimensions
Dimension are given in mm (inches). Tolerance : +/- 0,2 mm (+/- 0.01 “) unless otherwise indicated.
Weight : 10 grams (0.3 Ozs) max.
32,00
19,30
(1.25")
(0.75")
7,00
7,50
(0.25")
(0.31")
5 min
(0,20")
10,15
2,54
(0.40")
(0.10")
1,90
(0.07")
15,24
27,94
(0.60")
(1.10")
Pin dimensions : O 0,53 mm (0.02 ”)
Metallic case black anodized coating solder plated pin
For triple output models outline dimensions are : 35 mm (1.4’’) x 20 mm (0.8’’) x 10,50 mm (0.4’’)
15- Product Marking
Upper face : Company logo, location of manufacturing.
Side face : Module reference, option, date code : year and week of manufacturing.
4
16- Connections
12
11
13
14
13
11
10
20
2
1
23
24
Single output model
2
1
15
13
14
15
20
20
23
24
Bi output model
12
11
2
1
23
24
Triple output model
Pin
1
2
10
11
12
13
14
15
20
23
24
Single
+ Input (Vi)
+ Input (Vi)
/
Common (Go)
Common (Go)
Output (Vo)
Output (Vo)
/
On/Off
- Input (Gi)
- Input (Gi)
Bi
+ Input (Vi)
+ Input (Vi)
Common (Go)
Common (Go)
/
Output - (-Vo)
/
Output + (+Vo)
On/Off
- Input (Gi)
- Input (Gi)
Triple
+ Input (Vi)
+ Input (Vi)
/
Common (Go)
Common (Go)
Output 2- (-V2)
Output 1 (V1)
Output 2+(+V2)
On/Off
- Input (Gi)
- Input (Gi)
Bottom view
© Gaia Converter FC97-008.08/06 Revision N
13
For locations, phone, fax, E-Mail see back cover
International Headquarters
GAÏA Converter - France
ZI de la Morandière
33185 LE HAILLAN - FRANCE
Tel. : + (33)-5-57-92-12-80
Fax : + (33)-5-57-92-12-89
North American Headquarters
GAÏA Converter Canada, Inc
4038 Le Corbusier
LAVAL, QUEBEC - CANADA H7L 5R2
Tel. : (514)-333-3169
Fax : (514)-333-4519
Represented by :
Information given in this datasheet is believed to be accurate and reliable. However, no responsibility is assumed for the consequence of its use nor for any infringement of patents or other rights of third parties which may result from its use.
These products are sold only according to GAIA Converter general conditions of sale, unless otherwise confirmed by writing. Specifications subject to change without notice.
Printed in France by GAIA Converter FC97-008.08/06 Revision N Graphisme : Philippe Clicq
For more detailed specifications and applications information, contact :
Similar pages