AC-DC 400/600 Watts CCH400-600 Series xppower.com • Baseplate Cooled • High Efficiency up to 90% • -40 °C to +85 °C Operation • Industrial & MIL-STD461E EMC Compliance • Power Fail, Inhibit, Overtemp & Current Share • 5V Standby Output • 3 Year Warranty Specification Input General • 90-264 VAC • 47-400 Hz(1) • CCH400: 4.3/2.1 A typ. at 115/230 VAC, CCH600: 6.3/3.1 A typ. at 115/230 VAC, full load Inrush Current • 60 A max at 230 VAC, 25 °C cold start Power Factor • >0.9 Earth Leakage Current • 0.7/1.1 mA at 115/230 VAC at 60/50 Hz Input Protection • Internal F10 A/250 V fuse Input Voltage Input Frequency Input Current Switching Frequency Signals MTBF • 89% typical • 3000 VAC Input to Output, 1500 VAC Input to Ground, 500 VDC Output to Ground • 30-333 kHz PFC, 51.1 kHz main and 138 kHz standby converter • Power Fail, Inhibit, Current Share, Overtemperature Warning and 5 V Standby • 300 kHrs to MIL-HDBK-217F at 25 °C, GB Environmental Output Output Voltage Output Voltage Trim Initial Set Accuracy Minimum Load Start Up Delay Start Up Rise Time Hold Up Time Drift Line Regulation Load Regulation Over/Undershoot Transient Response • • • • • • • • • • • • Ripple & Noise • Overvoltage Protection • Overload Protection • Short Circuit Protection • Temperature Coefficient Overtemp. Protection Remote Sense Remote On/Off Efficiency Isolation • 12-48 VDC ±10% ±1% V1, ±3% V2 No minimum load required Typically 1 s 50 ms typical 20 ms min ±0.2% after 20 min warm up ±0.5% max ±1% V1, ±5% V2 max 1% typical 4% max. deviation, recovery to within 1% in 500 µs for a 50-75-50% load change Typically 1% pk-pk V1, V2 2%, 20 MHz bandwidth 110-140% Vnom, recycle input to reset 105-140% V1 only Continuous, approximately constant current 0.05%/˚C • Fitted • Compensates for 0.5 V total voltage drop • Uncommitted isolated optocoupler diode, powered diode inhibits V1 Notes 1. Safety approvals cover frequency 47-63 Hz. Operating Temperature • -40 ˚C to +85 ˚C baseplate, see thermal considerations Cooling • Baseplate, conduction cooling Operating Humidity • 95% RH, non-condensing Storage Temperature • -40 ˚C to +85 ˚C Operating Altitude • 3000 m Shock • MIL-STD 810F Clause 516.5 proc 1 Vibration • MIL-STD 810F figure 514.5C-17 EMC & Safety Low Voltage PSU EMC • EN61204-3, high severity level Emissions • EN55022 level B conducted, level A radiated, MIL-STD 461D-F, CE102 Harmonic Currents • EN61000-3-2, class A Voltage Flicker • EN61000-3-3 Radiated Immunity • EN61000-4-3, level 3 Perf Criteria A EFT/Burst • EN61000-4-4, level 3 Perf Criteria A Surge • EN61000-4-5, installation class 3 Perf Criteria A Conducted Immunity • EN61000-4-6, level 3 Perf Criteria A, MIL-STD 461 CS114 Dips & Interruptions • EN61000-4-11, 30% 10 ms, 60% 100 ms, 100% 5000 ms, Perf Criteria A, B, B Safety Approvals • IEC60950-1 CB report, UL60950-1, TUV EN60950-1 Equipment Protection • Class I Class AC-DC CCH400/600 Models and Ratings Output Power 411 W 411 W 409 W 411 W Output Voltage V1 12.0 VDC 24.0 VDC 28.0 VDC 48.0 VDC 603 W 603 W 605 W 603 W 12.0 VDC 24.0 VDC 28.0 VDC 48.0 VDC Output Current V1 34.0 A 17.0 A 14.5 A 8.5 A 50.0 25.0 21.5 12.5 Standby Supply V2 5.0 V/0.5 A 5.0 V/0.5 A 5.0 V/0.5 A 5.0 V/0.5 A A A A A 5.0 V/0.5 5.0 V/0.5 5.0 V/0.5 5.0 V/0.5 Model Number CCH400PS12 CCH400PS24 CCH400PS28 CCH400PS48 A A A A CCH600PS12 CCH600PS24 CCH600PS28 CCH600PS48 Mechanical Details 8.43 (214.00) - + Voltage Adjust. Pin 1 2 3 4 5 6 7 8 9 10 Signals Connector Exploded View Signal Connector Function Current Share Inhibit Overtemp. Warning Power Fail +Sense -Sense -Standby -Standby +Standby +Standby Pin 2 Pin 1 P in 10 Pin 9 4.02 (102.00) See note 5. 0.30 (7.72) Input Connector 3 Way AMP/Tyco Input Connector Connector: 10 WAY 2mm pitch p/n MOLEX 87833-1031 Mating half: p/n MOLEX 51110-1056 Contact: p/n MOLEX 50394-8100 Pin 1 2 3 Output Terminals (M4) Torque 8 in-lb (0.9 Nm) max 1.69 (43.00) Input Connector Function Earth Neutral Line Pin 3 Pin 2 Pin 1 7.84 (199.00) 4.21 (107.00) 0.59 (15.00) Connector: 3 way AMP/Tyco type MATE-N-LOK 1-350943-0 M4 fixings in 6 positions Max. screw penetration to be 0.16 (4.0) from bottom face of baseplate Torque 13.2 in-lb (1.5 Nm) max Mates with MATE-N-LOK 350766-1 0.177 Ø (4.50) thru in 4 positions Notes 3.48 (88.4) 1. All dimensions in inches (mm). 2. Tolerance .xx = ±0.02 (0.50); .xxx = ±0.01 (0.25) 3. Weight 3.3 lbs (1.5 kg) 4. Connector kit available, order part no. ‘CCH CONKIT’ 5. Inhibit, overtemperature and power fail are referenced to the OV power terminal. 2.83 (72.00) 1.18 (30.00) 0.20 (5.00) 0.27 (6.80) 8.23 (209.00) Thermal Considerations The baseplate must be maintainedat or below 85 °C and therefore a suitable heatsink must be selected to remove the heat from the power supply. Details of the heatsink calculations and other considerations can be found in the longform datasheet. 50 0 -40 Some specification parameters may not be met Output Load (%) 100 -20 0 +85 Baseplate Temperature (ºC) 31 Jan 17