Vicor MI-AIM-M1-F4 Ac input front end module Datasheet

Alternating Input Module
MI-AIM™
Actual size:
2.28 x 2.4 x 0.5in
57,9 x 61,0 x 12,7mm
AC Input Front End Module
Features & Benefits
Packaging Options
• Inputs: 115VAC 60/400Hz
Standard:
Slotted baseplate
• Output power: 250W
SlimMod:
• MIL-STD-704A input transient
protection
Flangeless baseplate, option suffix: - S
Example: MI - AIM - M1 - S
FinMod:
Finned heat sink, option suffix:
- F1, - F2, -F3 or -F4
• MIL-STD-461D/E EMI compliant*
• MIL-STD-810, MIL-STD-202
environments­
• Compatible with MI-x7x family
modules
• Efficiency: 95%
Examples:
MI - AIM - M1 -F1, 0.25” fins, longitudinal
MI - AIM - M1 -F2, 0.50” fins, longitudinal
MI - AIM - M1 -F3, 0.25” fins, transverse
MI - AIM - M1 -F4, 0.50” fins, transverse
Input Characteristics
• Operating temperature to 100˚C
Parameter
• Size: 2.28” x 2.4” x 0.5”
(57,9 x 61,0 x 12,7mm)
AC line input
Min
Typ
Max
Unit
85
115
140
VAC
47
60/400
440
Hz
40
A, peak
Inrush current
Product Highlights
The AC input module interfaces directly with
AC mains to provide line rectification, EMI
filtering, transient protection, and inrush
limiting. These front-end modules accept
115VAC and provide 250W of output power for
any of Vicor’s MI-x7x family of standard and
junior size modules.
Notes
Operates over entire range
125VAC
Conducted EMI*CE102 per MIL-STD-461 D/E
100 – 125VAC; 60Hz
Performance Criteria: Nominal
output voltage may deviate but
self recovers
TABLE SAC109-II normal
Input transient
voltage transients
MIL-STD-704A/
MIL-HDBK-704-1-8
TABLE SAC302-II abnormal
voltage transients
Performance Criteria: Nominal
output voltage may deviate but
self recovers
*EMI performance is subject to a wide variety of external influences such as PCB construction,
circuit layout etc. As such, external components in addition to those listed herein may be required in
specific instances to gain full compliance to the standards specified.
The MI-AIM meets CE102 conducted
emissions requirements of MIL-STD-461D/E*
and the transient and spike requirements of
MIL-STD-704A.
Fully encapsulated in Vicor’s industry standard
package, the MI-AIM meets
MIL-STD-810 Environmental testing
requirements for humidity, fungus,
salt-fog, explosive atmosphere, acceleration,
vibration and shock.
Output Characteristics
Parameter
Min
Output power
Typ
Max
250
Unit
Notes
W
100 °C
Hold-up time Application specific
A function of external
capacitance and power
Efficiency95%
115VAC; 60/400Hz
Model Selection Chart
Model Number Compatible MI-Series
MI-AIM-M1
MI-AIM-I1
MI-AIM™
Page 1 of 5
Rev 1.6
06/2017
MI-27x /MI-J7x
MI-27x /MI-J7x
Converter
Operating Temp (°C)
Storage Temp (°C)
M–grade
I–grade
–55 to +85 /+100
–40 to +85 /+100
–65 to +100 /+125
–55 to +100/+125
vicorpower.com
800 927.9474
MI-AIM™
Specifications
(typical at TBP = 25°C, nominal line and 75% load, unless otherwise specified)
SAFETY SPECIFICATIONS
Parameter
Min
Dielectric withstand
Input to output
Input/output to baseplate
Typ
Max
Unit
None
1,500
Notes
Provided by DC-DC converter
VRMS
ENVIRONMENTAL — MIL-STD-810D
Parameter
Min
Typ
Max
Unit
Notes
Procedure II
Altitude - Method 500.2
70,000 feet
Humidity - Method 507.2
88/ 240 %/ hours
Procedure I, cycle 1
Acceleration - Method 513.3
9.0
g
Procedure II
Vibration - Method 514.3
20
g
Procedure I, category 6
Shock - Method 516.3
40
g
Procedure I
RELIABILITY — MIL-HDBK-217F (MI-AIM-M1)
Parameter
Min
Typ
Max
Unit
25°C Ground Benign: G.B.
5,545
1,000 hrs
50°C Naval Sheltered: N.S.
998
1,000 hrs
65°C Airborne Inhabited Cargo: A.I.C. 782
1,000 hrs
Notes
GENERAL SPECIFICATIONS
Parameter
Min
Size
Typ
Max
2.28 x 2.4 x 0.5 (57,9 x 61,0 x 12,7) Unit
Notes
in (mm)
3.0
Ounces
Weight
(85)
(Grams)
MI-AIM™
Page 2 of 5
Rev 1.6
06/2017
vicorpower.com
800 927.9474
MI-AIM™
Specifications (Cont.)
PRODUCT GRADE SPECIFICATIONS
Parameter
I-Grade
M-Grade
Storage temperature
-55°C to +125°C
-65°C to +125°C
Operating temperature (baseplate)
-40°C to +100°C
-55°C to +100°C
12 hours, 29 cycles
96 hours, 213 cycles
12 cycles
-65°C to +100°C
12 cycles
-65°C to +100°C
-40°C, +80°C
-55°C, +80°C
2 years
2 years
MIL-STD-810
MIL-STD-810
NAVMAT P-4855-1A
NAVMAT P-4855-1A
Power cycling burn-in
Temperature cycled with power off
17°C per minute rate of change
Test data supplied at these temperatures [a]
Warranty
Environmental compliance
Derating
[a]
Test data available for review or download from vicorpower.com
ENVIRONMENTAL QUALIFICATIONS
Parameter
Altitude
Explosive Atmosphere
Qualification
MIL-STD-810D, Method 500.2, Procedure III, explosive decompression (40K ft.).
MIL-STD-810D, Method 500.2, Procedure II, 40,000ft., 1000 – 1500ft./ min. to 70,000ft., unit functioning
MIL-STD-810C, Method 511.1, Procedure I
MIL-STD-810D, Method 514.3, Procedure I, category 6, helicopter, 20g
Vibration
MIL-STD-810D, Method 514.3 random: 10 – 300Hz @ 0.02g 2 /Hz, 2000Hz @ 0.002g 2 / Hz, 3.9 total Grms
3h­rs/axis. Sine: 30Hz @ 20g, 60Hz @ 10g, 90Hz @ 6.6g, 120Hz @ 5.0g, 16.0 total Grms, 3 axes
MIL-STD-810E, Method 514.4, Table 514.4-VII, ±6db/octave, 7.7Grms, 1hr/axis
MIL-STD-810D, Method 516.3, Procedure I, functional shock, 40g
Shock
MIL-STD-202F, Method 213B, 18 pulses, 60g, 9msec
MIL-STD-202F, Method 213B, 75g, 11ms saw tooth shock
MIL-STD-202F, Method 207A, 3 impacts / axis, 1, 3, 5 feet
Acceleration
MIL-STD-810D, Method 513.3, Procedure II Operational test, 9g for 1 minute along 3 mutually perpendicular axes
Humidity
MIL-STD-810D, Method 507.2, Procedure I, cycle I, 240hrs, 88% relative humidity
Solder Test
MIL-STD-202, Method 208, 8hr. aging
Fungus
MIL-STD-810C, Method 508.1
Salt-Fog
MIL-STD-810C, Method 509.1
Storage
Vicor products, when not installed in customer units, should be stored in ESD safe packaging in accordance with ANSI/ESD S20.20,
“Protection of Electrical and Electronic Parts, Assemblies and Equipment” and should be maintained in a temperature controlled factory/
warehouse environment not exposed to outside elements controlled between the temperature ranges of 15°C and 38°C. Humidity shall not
be condensing, no minimum humidity when stored in an ESD compliant package.
MI-AIM™
Page 3 of 5
Rev 1.6
06/2017
vicorpower.com
800 927.9474
MI-AIM™
Mechanical Drawings, Connection Diagram
0.01µF (Two 4700pF)
Y-Rated Capacitors
F1
L1
AC IN
N/C
0.47µF
F2
+OUT
GATE IN
GATE IN
C1[b]
PAR
N/C
GATE OUT
L2/N
+OUT
+IN
GATE OUT
+S
MI-27x/J7x
Driver
TRIM
–OUT
MI-AIM
[b]
0.01µF (Two 4700pF)
Y-Rated Capacitors
1,200µF max.
Fuse 1: 7A F03A type recommended
Fuse 2: MI-x7x-xx – Buss PC – TRON 2 – 5A (450V)
VI-AIM Mechanical
Figure 1 — MI-AIM Connection diagram, typical application
in
(mm)
.30.015
(7,6)(0,38)
.49
(12,4)
2.28
(57,9)
1.30
(33,0)
.65
(16,5)
.080 Dia (2) places
Solder plate
over copper alloy
4
2.10
(53,4)
3
2
9
8
VI-AIM
MI-AIM
1.40
1.00 (35,6)
.70 (25,4)
.40 (17,8)
(10,2)
7
6
1
.15
(3,8)
Pin #
1
2
3
4
5
6
7
8
9
5
.35 .015
(8,9)(0,38)
FULL R
.15
(3,8)
1.90
(48,3)
Function
L1
NC
NC
L2/N
+OUT
Gate In
Parallel
Gate Out
–OUT
.040 (1,0) Dia (7) places
Solder plate
over copper alloy
Product ID
this surface
2.40
(61,0)
.22
(5,6) Min.
.50
(12,7)
.12
(3,0)
1.75 Max.
(44,4)
.30 Min.
(7,6)
+.030
(0,76)
-.000
(0)
.01
Aluminum Base
Figure 2 — Mechanical diagram
Note: For alternate packaging options refer to the mechanical drawing page at vicorpower.com
MI-AIM™
Page 4 of 5
Rev 1.6
06/2017
vicorpower.com
800 927.9474
Load
–S
–IN
–OUT
0.01µF Ceramic
0.01µF Ceramic
MI-AIM™
Vicor’s comprehensive line of power solutions includes high density AC-DC and DC-DC modules and
accessory components, fully configurable AC-DC and DC-DC power supplies, and complete custom
power systems.
Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is assumed by Vicor for its use. Vicor
makes no representations or warranties with respect to the accuracy or completeness of the contents of this publication. Vicor reserves
the right to make changes to any products, specifications, and product descriptions at any time without notice. Information published by
Vicor has been checked and is believed to be accurate at the time it was printed; however, Vicor assumes no responsibility for inaccuracies.
Testing and other quality controls are used to the extent Vicor deems necessary to support Vicor’s product warranty. Except where
mandated by government requirements, testing of all parameters of each product is not necessarily performed.
Specifications are subject to change without notice.
Visit http://www.vicorpower.com/mil-cots_ac-dc/mil-cots_mi-aim_ac_input_module for the latest product information.
Vicor’s Standard Terms and Conditions and Product Warranty
All sales are subject to Vicor’s Standard Terms and Conditions of Sale, and Product Warranty which are available on Vicor’s webpage
(http://www.vicorpower.com/termsconditionswarranty) or upon request.
Life Support Policy
VICOR’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE
EXPRESS PRIOR WRITTEN APPROVAL OF THE CHIEF EXECUTIVE OFFICER AND GENERAL COUNSEL OF VICOR CORPORATION. As used
herein, life support devices or systems are devices which (a) are intended for surgical implant into the body, or (b) support or sustain life and
whose failure to perform when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to
result in a significant injury to the user. A critical component is any component in a life support device or system whose failure to perform
can be reasonably expected to cause the failure of the life support device or system or to affect its safety or effectiveness. Per Vicor Terms
and Conditions of Sale, the user of Vicor products and components in life support applications assumes all risks of such use and indemnifies
Vicor against all liability and damages.
Intellectual Property Notice
Vicor and its subsidiaries own Intellectual Property (including issued U.S. and Foreign Patents and pending patent applications) relating
to the products described in this data sheet. No license, whether express, implied, or arising by estoppel or otherwise, to any intellectual
property rights is granted by this document. Interested parties should contact Vicor’s Intellectual Property Department.
Vicor Corporation
25 Frontage Road
Andover, MA, USA 01810
Tel: 800-735-6200
Fax: 978-475-6715
email
Customer Service: [email protected]
Technical Support: [email protected]
MI-AIM™
Page 5 of 5
Rev 1.6
06/2017
vicorpower.com
800 927.9474