Click on Series name for product info on aimtec.com Series AMEPR60C-AZ up to 5A | AC-DC / DC-DC | LED Driver / Converter FEATURES: AC-DC Constant Current or Constant Voltage LED Driver Input range 90-305VAC/47-440Hz High Efficiency up to 89% Operating temperature -40 to 85°C Dimmable via resistive / 0-10Vdc / PWM 5 Years Limited Warranty Models Single output Model Output Voltage Range (V) ③ Output Current (A) ③ Input Voltage (VAC/Hz) Input Voltage (VDC) Over Temperature Protection Over Current Protection Waterproof Case rated IP68 Power Factor Correction Short Circuit Protection Mode of Operation OCP / OVP Max Output Power (W) ① Efficiency (%) 1.27 90-305 / 130-430 Constant Current 60 89 47-440 50.7 1.77 90-305 / AMEPR60C-36170AZ 24-36 0 - 1.70 130-430 Constant Current 59.8 88 47-440 36.6 2.55 90-305 / AMEPR60C-24250AZ 12-24 0 - 2.50 130-430 Constant Current 60 87 47-440 24.5 5.2 90-305 / AMEPR60C-12500AZ 5-12 0 - 5.0 130-430 Constant Current 60 85 47-440 12.3 ① Exceeding the maximum output power will permanently damage the converter ② The dimming feature is not supported when units are used in Constant Voltage mode only. ③ In constant current mode output current is maximum shown, in constant voltage mode output voltage is the maximum shown. All models can be ordered with optional North American colour input wires (black (L), white (N), green (GND)). Add “–NA” to part number when ordering. Note: Aimtec limited warranty of 5 years is valid based on product operation at datasheet specifications at ambient temperature of 25°C, humidity<75%, nominal input voltage (115/230/277VAC) and at rated output load unless otherwise specified. See http://www.aimtec.com/terms-sale AMEPR60C-AZ’s AC/DC LED drivers have electrical safeguards designed within to protect it from conventional electrical abnormalities with the levels listed in the safety table. Applications for use within rural agricultural, heavy industrial, and other areas or regions which are prone to ‘dirty’ electrical conditions which would subject any of the above models to excessive voltages surges or spikes, may damage or cause early life failure of product. In this case consideration should be made by the end user to ensure that adequate line or mains surge suppression is installed in front of Aimtec device to ensure the longevity of the products. Failure to identify excessive line surges violations prior to installation may damage sensitive equipment permanently. AMEPR60C-50120AZ 36-50 0 - 1.20 Input Specifications Parameters Inrush current <2ms Leakage current AC current Power Factor External fuse Start up time Surge voltage www.aimtec.com F 052.1e R3.G Conditions Typical 115VAC 230VAC 115VAC 230VAC 115VAC 230VAC 115VAC 230VAC 277VAC 30 50 0.5 0.7 0.73 0.33 Maximum Units A mA A 0.98 0.96 0.93 250V/1.5A 250 2sec 440 Tel: +1 514 620 2722 1 of 13 ms V Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEPR60C-AZ up to 5A | AC-DC / DC-DC | LED Driver / Converter Output Specifications Parameters Conditions Typical Maximum Units Current accuracy (CC Mode) ±3 Voltage accuracy (CV Mode) ±3 Line regulation LL-HL ±1 Load regulation 0-100% load ±3 20MHz Bandwidth 75 Ripple & Noise ④ Hold-up time 90 Current adjustment range 100-0 Minimum Load Voltage See the models table ④ Tested with 0.1µF (C/C) or (M/C) and 47µF (E/C) parallel capacitors at the end. % % % % mV p-p ms % Isolation Specifications Parameters Conditions Tested I/O voltage Isolation Resistance Isolation Capacitance Typical 3 sec/3.5mA 500VDC Rated Units 3000 VAC MΩ pF >1000 1000 General Specifications Parameters Conditions Typical Switching frequency Maximum 130 Over current protection Over voltage protection Short circuit protection Short circuit restart Over temperature protection Operating temperature Maximum case temperature Storage temperature Temperature coefficient Cooling Humidity Case material Potting Wires Weight Dimensions (L X H X W) MTBF Units KHz AMEPR60C-50120AZ AMEPR60C-36170AZ AMEPR60C-24250AZ AMEPR60C-12500AZ Refer to Constant Current vs. Constant Voltage Mode curve Continuous Auto recovery >105°C With derating over 55°C -40 to +85 1.27 1.77 2.55 5.2 A oC 100 oC oC -40 to +95 ±0.02 Free air convection % / oC 95 Plastic Epoxy (IP67 rated) UL1015 18AWG *20CM 530 5.30 x 2.27 x 1.59 inches 134.80 x 57.68 x 40.50 mm >400,000 hrs (MIL-HDBK-217F at +25°C) % RH g Safety Specifications Parameters Agency approvals Standards www.aimtec.com F 052.1e R3.G cULus, CE UL8750, UL60950-1, EN55022, class B, EN60529(IP68), EN61347-1, EN61347-2-13 Information Technology Equipment EN55022 Class B Harmonic Current Emissions IEC/EN 61000-3-2, Class C Voltage fluctuations and flicker IEC/EN 61000-3-3, (EN60555-3) Electrostatic Discharge Immunity IEC 61000-4-2 Level 3 RF, Electromagnetic Field Immunity IEC 61000-4-3 Level 2 Electrical Fast Transient / Burst Immunity IEC 61000-4-4 Level 2 Surge Immunity IEC 61000-4-5 Level 3 RF, Conducted Disturbance Immunity IEC 61000-4-6 Level 2 Power frequency Magnetic Field Immunity IEC 61000-4-8 Level 1 Voltage dips, Short Interruptions Immunity IEC 61000-4-11 Tel: +1 514 620 2722 2 of 13 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEPR60C-AZ up to 5A | AC-DC / DC-DC | LED Driver / Converter Dimensions Wire connection: Wire Brown Blue Green Red Black Blue (Dimming) White (Dimming) Connection AC L AC N Ground +V output -V Output + Vs dimming -Vs dimming Temperature Graph www.aimtec.com F 052.1e R3.G Tel: +1 514 620 2722 3 of 13 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEPR60C-AZ up to 5A | AC-DC / DC-DC | LED Driver / Converter Dimming Control “C” Versions AMEPR60C-50120AZ www.aimtec.com F 052.1e R3.G Tel: +1 514 620 2722 4 of 13 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEPR60C-AZ up to 5A | AC-DC / DC-DC | LED Driver / Converter AMEPR60C-36170AZ www.aimtec.com F 052.1e R3.G Tel: +1 514 620 2722 5 of 13 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEPR60C-AZ up to 5A | AC-DC / DC-DC | LED Driver / Converter AMEPR60C-24250AZ www.aimtec.com F 052.1e R3.G Tel: +1 514 620 2722 6 of 13 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEPR60C-AZ up to 5A | AC-DC / DC-DC | LED Driver / Converter AMEPR60C-12500AZ www.aimtec.com F 052.1e R3.G Tel: +1 514 620 2722 7 of 13 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEPR60C-AZ up to 5A | AC-DC / DC-DC | LED Driver / Converter Efficiency Vs. Input Voltage & Output Current (Constant current load) AMEPR60C-50120AZ AMEPR60C-36170AZ www.aimtec.com F 052.1e R3.G Tel: +1 514 620 2722 8 of 13 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEPR60C-AZ up to 5A | AC-DC / DC-DC | LED Driver / Converter AMEPR60C-24250AZ AMEPR60C-12500AZ www.aimtec.com F 052.1e R3.G Tel: +1 514 620 2722 9 of 13 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEPR60C-AZ up to 5A | AC-DC / DC-DC | LED Driver / Converter PFC Value vs. Output Load Current (constant current mode) AMEPR60C-50120AZ AMEPR60C-36170AZ www.aimtec.com F 052.1e R3.G Tel: +1 514 620 2722 10 of 13 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEPR60C-AZ up to 5A | AC-DC / DC-DC | LED Driver / Converter AMEPR60C-24250AZ AMEPR60C-12500AZ www.aimtec.com F 052.1e R3.G Tel: +1 514 620 2722 11 of 13 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEPR60C-AZ up to 5A | AC-DC / DC-DC | LED Driver / Converter Constant Current vs. Constant Voltage Mode AMEPR60C-50120AZ AMEPR60C-36170AZ www.aimtec.com F 052.1e R3.G Tel: +1 514 620 2722 12 of 13 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEPR60C-AZ up to 5A | AC-DC / DC-DC | LED Driver / Converter AMEPR60C-24250AZ AMEPR60C-12500AZ NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 052.1e R3.G Tel: +1 514 620 2722 13 of 13 Toll free: + 1 888 9 AIMTEC (924 6832) North America only