Keysight Technologies NFA X-Series Noise Figure Analyzer, Multi-touch N8973B, N8974B, N8975B, N8976B 10 MHz to 3.6, 7.0, 26.5, or 40.0 GHz Data Sheet 02 | Keysight | N8973B, N8974B, N8975B, N8976B NFA X-Series Noise Figure Analyzer, Multi-touch - Data Sheet Specifications Specifications describe the performance of parameters covered by the product warranty. These values are only valid for the stated operating frequency, and apply over 0°C to +55°C unless otherwise noted. 95th percentile values indicate the breadth of the population (approx. 2 s) of performance tolerances expected to be met in 95 percent of the cases with a 95 percent confidence, for any ambient temperature in the range of +20°C to +30°C. In addition to the statistical observations of a sample of instruments, these values include the effects of the uncertainties of external calibration references. These values are not warranted. These values are updated occasionally if a significant change in the statistically observed behavior of production instruments is observed. Typical describes additional product performance information that is not covered by the product warranty. It is performance beyond specifications that 80 percent of the units exhibit with a 95 percent confidence level over the temperature range of +20°C to +30°C. Typical performance does not include measurement uncertainty. Nominal values indicate expected performance, or describe product performance that is useful in the application of the product, but are not covered by the product warranty. The analyzer will meet its specifications when: –– It is within its calibration cycle –– Under auto couple control, except when Auto Sweep Time Rules = Accy –– Signals measured <10 MHz have DC coupling applied –– The analyzer has been stored at an ambient temperature within the allowed operating range for at least two hours before being turned on; if it had previously been stored at a temperature range inside the allowed storage range, but outside the allowed operating range –– The analyzer has been turned on at least 30 minutes with Auto Align set to normal, or, if Auto Align is set to off or partial, alignments must have been run recently enough to prevent an Alert message; if the Alert condition is changed from Time and Temperature to one of the disabled duration choices, the analyzer may fail to meet specifications without informing the user For the complete specifications guide, visit: www.keysight.com/find/NFA_X-Series_specifications 03 | Keysight | N8973B, N8974B, N8975B, N8976B NFA X-Series Noise Figure Analyzer, Multi-touch - Data Sheet Frequency Frequency range N8973B 10 MHz to 3.6 GHz N8974B 10 MHz to 7.0 GHz N8975B N8976B 10 MHz to 26.5 GHz 4 10 MHz to 40.0 GHz Measurement bandwidth (nominal) N8973B, N8974B, N8975B, N8976B 5 1 Hz to 3 MHz (in E24 series increments 1), 4 MHz, 5 MHz, 6 MHz, 8 MHz Frequency reference Accuracy ± [RΔt + T + C] Aging rate ± 0.1 ppm 2 /year ± 0.15 ppm/2 years Temperature stability +20°C to +30°C Full temperature range ± 0.015 ppm ± 0.05 ppm Achievable initial calibration accuracy ± 0.04 ppm Example frequency reference accuracy, Residual FM </= (use less than or equal to symbol) (0.25 Hz x N) p-p in 20 ms nominal 1 year since last adjustment = ± (1 x 10 -7 + 5 x 10 -8 + 4 x 10 -8) Frequency readout accuracy (start, stop, center, marker) ± (marker frequency x frequency reference accuracy + 0.25% x span + 5% x RBW + 2 Hz + 0.5 x horizontal resolution 3) 1. 2. 3. 4. 5. R = aging rate Δt = time since last adjustment T = temperature stability C = calibration accuracy = ± 0 0.19 ppm The E24 series is defined by international standard IEC 60063. E24 is a preferred series of numbers, with each number being approximately 10% larger than the previous number. It is commonly used for the labeling of 5% tolerance resistors, capacitors, etc. Parts per million (10-6) Horizontal resolution is span/(sweep points – 1). The N8976B ships with 346CK40. The 346CK40 has superior match above 26 GHz, which leads to better uncertainty. IQ analyzer (basic) mode has up to 25 MHz analysis BW. Note: The NFA X-Series noise figure analyzer is more than a dedicated noise figure analyzer. Each model has full featured spectrum analyzer and IQ analyzer (basic) modes. The analyzer is specified to 44 GHz when in SA or IQ analyzer mode. 04 | Keysight | N8973B, N8974B, N8975B, N8976B NFA X-Series Noise Figure Analyzer, Multi-touch - Data Sheet Noise figure, gain, and uncertainty Example DUT uncertainties 1 Without a Preamp With a USB Preamp 2 When combined with the U7227A/C/F preamp, the NFA X-Series noise figure analyzer offers improved uncertainty over the previous NFA-A in all of the above hypothetical cases. 1. 2. These uncertainties assume a measurement made with a N8975B at 1 GHz with a N4000A noise source and a non-frequency-converting DUT. The DUT is assumed to have an input/output match of 1.5 VSWR. Assuming a U7227A/C/F External USB Preamp 05 | Keysight | N8973B, N8974B, N8975B, N8976B NFA X-Series Noise Figure Analyzer, Multi-touch - Data Sheet Description Specifications Supplemental information Noise figure ‹ 10 MHz 10 MHz to internal preamplifier’s frequency limit 1 Uncertainty calculator 1 See note 1 Internal and external preamplification recommended 1 Noise source ENR Measurement range Instrument uncertainty 4 to 6.5 dB 0 to 20 dB ± 0.02 dB 12 to 17 dB 0 to 30 dB ± 0.025 dB 20 to 22 dB 0 to 35 dB ± 0.03 dB Gain Instrument uncertainty 1 DUT Gain range = –20 to +40 dB ‹ 10 MHz See note 1 10 MHz to 3.6 GHz ± 0.15 dB › 3.6 GHz ± 0.11 dB additional 1 95th percentile, 5 minutes after calibration Noise Figure uncertainty calculator1, 2 Instrument noise figure uncertainty Instrument gain uncertainty Instrument noise figure See the noise figure table above See the gain table above See graphs of “Nominal instrument noise figure”; noise figure is DANL + 176.24 dB (nominal) 1. Note on DC coupling 1 See graph: nominal VSWR. Note on DC coupling 1 See “Displayed average noise level (DANL) (with noise floor extension) improvement” in the Option NFE - Noise floor extension chapter. Instrument input match Optional NFE improvement/internal Cal 1 Uncertainty versus calibration options1 User calibration Uncalibrated Internal calibration Best uncertainties; noise figure uncertainties calculator applies Worst uncertainties; noise of the analyzer input acts as a second stage noise on the DUT Available with Option NFE. Good uncertainties without the need of reconnecting the DUT and running a clibration. The uncertainty of the analyzer input noise model adds a second-stage noise power to the DUT that can be positive or negative. Running the noise figure uncertainty calculator will usually show that internal calibration achieves 90% of the possible improvement between the uncalibrated and user calibration states. 1. Refer to NFA X-Series specifications guide for footnote details 2. Online uncertainty calculator at www.keysight.com/find/nfuc or use the instrument’s built-in calculator. Nominal instrument noise figure, N8973B, N8974B, N8975B 06 | Keysight | N8973B, N8974B, N8975B, N8976B NFA X-Series Noise Figure Analyzer, Multi-touch - Data Sheet Internal Preamp noise figure Frequency Noise Figure (nominal) 100 kHz to 3.6 GHz 8 dB + (0.001112 * freq in MHz) nominal 3.6 GHz to 8.4 GHz 9 dB nominal 8.4 GHz to 13.6 GHz 10 dB nominal > 13.6 GHz DANL + 176.24 dB nominal Measurement uncertainty is usually dominated by the uncertainty of the noise source, meaning that the instrument’s noise figure is negligible for most measurements. For situations when this noise figure becomes non-negligible (i.e. low-gain, low-noise DUTs), the included U7227 Series USB preamp provides extra measurement reliability. DANL (N8973B, N8974B, N8975B) 1 Frequency Specification Typical 10.0 MHz to 2.1 GHz –161 dBm –163 dBm 2.1 GHz to 7.0 GHz –160 dBm –162 dBm 7.0 GHz to 13.6 GHz –160 dBm –163 dBm 13.5 GHz to 17.1 GHz –157 dBm –160 dBm 17.0 GHz to 20.0 GHz –155 dBm –159 dBm 20.0 GHz to 26.5 GHz –150 dBm –156 dBm Frequency Specification Typical 10.0 MHz to 1.2 GHz –164 dBm –165 dBm 1.2 GHz to 2.1 GHz –163 dBm –164 dBm 2.1 GHz to 3.6 GHz –162 dBm –163 dBm 3.5 GHz to 20.0 GHz –160 dBm –162 dBm 20.0 GHz to 26.5 GHz –158 dBm –160 dBm 26.4 GHz to 34.0 GHz –156 dBm –159 dBm 33.9 GHz to 40.0 GHz –153 dBm –155 dBm DANL (N8976B) 1 Preamp noise figure and gain 2 Specification U7227A U7227C U7227F Frequency 10 MHz to 4 GHz 100 MHz to 26.5 GHz 2 GHz to 50 GHz Noise figure 10 MHz to 100 MHz: < 5.5 dB 100 MHz to 4 GHz: < 5 dB 100 MHz to 4 GHz: < 6 dB 4 GHz to 6 GHz: < 5 dB 6 GHz to 18 GHz: < 4 dB 18 GHz to 26.5 GHz: < 5 dB Gain 10 to 100 MHz: > 16 dB 100 MHz to 4 GHz: > 17 + 0.5F dB 100 MHz to 26.5 GHz: > 16.1 + 0.26F dB Averaging Up to 10,000 measurement results * “F” signifies frequency in GHz 1. 2. Preamp on, input terminated, sample or average detector, log averaging, 0 dB input attenuation, IF Gain = High, +20°C to +30°C. See U7227A/C/F Data Sheet for list of specifications 2 GHz to 50 GHz: > 16.5 + 0.23F dB 07 | Keysight | N8973B, N8974B, N8975B, N8976B NFA X-Series Noise Figure Analyzer, Multi-touch - Data Sheet RF input Connector N8973B, N8974B, N8975B Type-N female, 50 Ω nominal N8976B 2.4 mm male, 50 Ω nominal Input VSWR Input VSWR N8973B, N8974B, N8975B N8976B 10 MHz to 3.6 GHz < 1.2:1 nominal 1.2:1 nominal 3.6 GHz to 26.5 GHz < 1.9:1 nominal 1.5:1 nominal 26.5 GHz to 44.0 GHz N/A < 1.8:1 nominal Measurement Sweep Number of points setting 2 to 501, or fixed frequency Start/stop, center/span, Frequency list of up to 501 points Sweep trigger Continuous or single Measurement speed Local measurement and display update rate 11 ms (90/s) Remote measurement and LAN transfer rate 6 ms (167/s) Marker peak search 5 ms Center frequency tune and transfer (RF) 22 ms Center frequency tune and transfer (µW) 49 ms Measurement/mode switching 75 ms DUT profiles available Amplifier Includes any non-frequency-converting device (e.g. amplifiers, attenuators, filters, etc) Downconverting DUT With fixed or variable IF. Instrument capable of controlling an external LO via GPIB, LAN, or USB Upconverting DUT With fixed or variable IF. Instrument capable of controlling an external LO via GPIB, LAN, or USB System downconverter Allows the use of an external downconverting mixer as part of the measurement system. Instrument capable of controlling an external LO via GPIB, LAN, or USB Measurement Display type and N.F. results Type 4U multitouch Output format Graphical, table of values, or meter mode Display channels 2 Number of markers 4 Limit lines Upper and lower for each of 2 channels Noise figure Noise figure (F dB), or as a ratio (F) Gain Gain (G dB) Y-factor Y-factor (Y dB) T effective Effective noise temperature in Kelvin P hot Relative power density in dB P cold Relative power density in dB 08 | Keysight | N8973B, N8974B, N8975B, N8976B NFA X-Series Noise Figure Analyzer, Multi-touch - Data Sheet Front panel Sweep Probe power Voltage/current +15 Vdc ± 7 % at 150 mA max nominal -12.6 Vdc ± 10 % at 150 mA max nominal USB 2.0 ports Master (2 ports) Standard Connector Output current Compatible with USB 2.0 USB Type-A female 0.5 A nominal Master (1 port) High power Connector Output current Compatible with USB 2.0 USB Type-A Female 1.0A nominal Rear panel connectivity 10 MHz out Connector Output amplitude Frequency BNC female, 50 Ω nominal ≥ 0 dBm nominal 10 MHz ± (10 MHz x frequency reference accuracy) Ext ref in Connector Input amplitude range Input frequency Frequency lock range BNC female, 50 Ω nominal –5 to 10 dBm nominal 10 MHz nominal ± 5 x 10 -6 of specified external reference input frequency Trigger 1 and 2 inputs Connector Impedance Trigger level range BNC female > 10 kΩ nominal –5 to 5 V Trigger 1 and 2 inputs Connector Impedance Trigger level range BNC female 50 Ω nominal 5 V TTL nominal Monitor output Connector Format Resolution VGA compatible, 15-pin mini D-SUB XGA (60 Hz vertical sync rates, non-interlaced) analog RGB 1024 x 768 Rear panel Noise source drive +28 V (pulsed) Connector BNC female SNS Series noise source connector For use with Keysight SNS Series noise sources USB 2.0 ports Master (4 ports) Standard Connector Oupt current Compatible with USB 2.0 USB Type-A female 0.5 A nominal Slave (1 port) Standard Connector Output current Compatible with USB 2.0 USB Type-B female 0.5 A nominal GPIB interface Connector GPIB codes GPIB mode IEEE-488 bus connector SH1, AH1, T6, SR1, LR1, PP0, DC1, C1, C2, C3, C28,DT1, L4, C0 Controller or device LAN TCP/IP interface Standard Connector 1000 Base-T RJ45 Ethertwist 09 | Keysight | N8973B, N8974B, N8975B, N8976B NFA X-Series Noise Figure Analyzer, Multi-touch - Data Sheet General Specifications Temperature range Operating 0 to 55°C Storage –40 to 70°C EMC Complies with European EMC Directive 2004/108/EC –– IEC/EN 61326-1 or IEC/EN 61326-2-1 –– CISPR Pub 11 Group 1, class A –– AS/NZS CISPR 11:2002 –– ICES/NMB-001 This ISM device cmplies with Canadian ICES-001 Get appareil ISM est conforme à la norme NMB-001 du Canada Safety Complies with European Low Voltage Directive 2006/95/EC –– IEC/EN 61010-1 3rd Edition –– Canada: CSA C22.2 No. 61010-1-12 –– U.S.A.: UL 61010-1 3rd Edition Acoustic statement (European Machinery Directive 2002/42/EC, 1.7.4.2u) Acoustic noise emission LpA < 70 dB Operator position Normal position Per ISO 7779 Environmental stress Samples of this product have been type tested in accordance with the Keysight Environmental Test Manual and verified to be robust against the environmental stresses of storage, transportation, and end-use; those stresses include, but are not limited to, temperature, humidity, shock, vibration, altitude, and power line conditions; test method are aligned with IEC 60068-2 and levels are similar to MILPRF-28800F Class 3. Power requirements Voltage and frequency Power consumption On Standy 100 to 120 V, 50/60/400 Hz 220 to 240 V, 50/60 Hz 350 W maximum 20 W Display Resolution 1280 × 768, WXGA Size 269 mm (10.6 in.) diagonal (nominal) Data storage Internal External ≥ 160 GB nominal (removable solid-state drive) Supports USB 2.0 compatible memory devices Weight (without options) Net Shipping 16 kg (35 Ibs) nominal 28 kg (62 Ibs) nominal Dimensions Height Width Length 177 mm (7.0 in) 426 mm (16.8 in) 368 mm (14.5 in) Warranty The NFA noise figure analyzer is supplied with a standard 3-year warranty Calibration cycle The recommended calibration cycle is two years: calibration services are available through Keysight service centers 10 | Keysight | N8973B, N8974B, N8975B, N8976B NFA X-Series Noise Figure Analyzer, Multi-touch - Data Sheet From Hewlett-Packard through Agilent to Keysight For more than 75 years, we‘ve been helping you unlock measurement insights. Our unique combination of hardware, software and people can help you reach your next breakthrough. Unlocking measurement insights since 1939. 1939 THE FUTURE myKeysight www.keysight.com/find/mykeysight A personalized view into the information most relevant to you. Three-Year Warranty www.keysight.com/find/ThreeYearWarranty Keysight’s committed to superior product quality and lower total cost of ownership. Keysight is the only test and measurement company with a three-year warranty standard on all instruments, worldwide. And, we provide a one-year warranty on many accessories, calibration devices, systems and custom products. Keysight Assurance Plans www.keysight.com/find/AssurancePlans Up to ten years of protection and no budgetary surprises to ensure your instruments are operating to specification, so you can rely on accurate measurements. For more information on Keysight Technologies’ products, applications or services, please contact your local Keysight office. The complete list is available at: www.keysight.com/find/contactus Americas Canada Brazil Mexico United States (877) 894 4414 55 11 3351 7010 001 800 254 2440 (800) 829 4444 Asia Pacific Australia China Hong Kong India Japan Korea Malaysia Singapore Taiwan Other AP Countries 1 800 629 485 800 810 0189 800 938 693 1 800 11 2626 0120 (421) 345 080 769 0800 1 800 888 848 1 800 375 8100 0800 047 866 (65) 6375 8100 Europe & Middle East Austria Belgium Finland France Germany Ireland Israel Italy Luxembourg Netherlands Russia Spain Sweden Switzerland Keysight Infoline www.keysight.com/find/service Keysight’s insight to best in class information management. Free access to your Keysight equipment company reports and e-library. Keysight Channel Partners www.keysight.com/find/channelpartners Get the best of both worlds: Keysight’s measurement expertise and product breadth, combined with channel partner convenience. United Kingdom 0800 001122 0800 58580 0800 523252 0805 980333 0800 6270999 1800 832700 1 809 343051 800 599100 +32 800 58580 0800 0233200 8800 5009286 800 000154 0200 882255 0800 805353 Opt. 1 (DE) Opt. 2 (FR) Opt. 3 (IT) 0800 0260637 For other unlisted countries: www.keysight.com/find/contactus (BP-01-01-16) www.keysight.com/go/quality Keysight Technologies, Inc. DEKRA Certified ISO 9001:2008 Quality Management System This information is subject to change without notice. © Keysight Technologies, 2016 Published in USA, February 3, 2016 5992-1270EN www.keysight.com