MPD LDC-185-0700x 200w output power Datasheet

LDC-185 Series
Compact, LED, 200W
Constant Current
AC/DC Power Supply
Key Features:
• 200W Output Power
• UL 8750 Approved
• Constant Current Output
• Active PFC
Electrical Specifications
Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Conditions
Input Frequency
Inrush Current, See Note 1
230 VAC
115 VAC
230 VAC
264 VAC
0.98 @ 115 VAC
0.95 @ 230 VAC
0.93 @ 264 VAC
See Note 2
115 VAC
230 VAC
277 VAC
• 90 - 305 VAC Input
• IP65 / IP67 Rated
Input Current
• Meets EN 55015, EN 61547
• Dimming Function
Power Factor Correction
• >50 kHour Life Expectancy Total Harmonic Distortion (THD)
• Lightning Surge Protection Turn On Delay, See Note 3
• Over Volt/Temp Protection
Min.
90
127
47
Input Voltage Range
Leakage Current
Typ.
Max.
305
431
63
75
2.10
0.90
0.80
Units
VAC
VDC
Hz
A Pk
A
10
1.5
0.5
%
S
75
mA
Max.
Units
%
%
V P-P
Output
Parameter
Output Current Accuracy
Line Regulation
Ripple & Noise (20 MHz)
Conditions
Output Ripple Current
Hold-Up Time
Over Temperature Protection
Short Circuit Protection
Overload Protection
Min.
Typ.
±5.0
±1.0
2.0
±5.0
±10.0
VIN = Min to Max
See Note 4
Outputs Below 50 VDC
Outputs Above 71 VDC
115 VAC 12.0
±10%, Autorecovery
85
Continuous (Autorecovery)
Autorecovery
95
%
mS
°C
107
%IOUT
General
Parameter
Conditions
Min.
Typ.
Max.
Units
Input to Output 3,750
Input to FG 2,000
VAC
Output to FG
500
Input to Output
Input to FG 100 M / 500 VDC / 25°C / 70% RH
Output to FG
Isolation Voltage, 60S
Insulation Resistance
EMI Characteristics
Parameter
EMI
EMS
Surge
Standard
EN 55015; EN 6100-3-2, -3; FCC Part 18; CNS 14115; GB 17743
EN 61547; EN 61000-4-2,-3, -4, -5, -6, -8, -11; GB 17625.1
10 kV (L/N - FG), 5 kV (L-N)/1.2 x 50 µS
MicroPower Direct
Environmental
292 Page Street
Suite D
Stoughton, MA 02072
USA
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Physical
Case Size
Weight
Conditions
Min.
Typ.
Max.
-40
+25
+70
-40
+85
Free Air Convection (See Derating Curve on Page 2)
RH, Non-condensing
95
Ambient
Units
°C
°C
%
See Mechanical Diagrams (Page 4)
33.1 Oz (950g)
Reliability Specifications
Parameter
MTBF
Life Expectancy
Safety Standards
Vibration
Conditions
Min.
Typ.
Max.
Units
MIL HDBK 217F, 25°C, Gnd Benign
220
kHours
See Note 5
50
kHours
UL 8750 Approved, Meets EN 61347, GB 19510.1, GB 19510.14
5 - 500 Hz, 1G , 1 Oct/Min, 2 Cycles, Period for 75 Min. Each Along X, Y, & Z Axis
www.micropowerdirect.com
www.micropowerdirect.com
Model Selection Guide
Output
Model
Number
Current
Output
Power
OVP Level
(VDC)
(W)
Efficiency
Max (mA)
Adj. Range (mA)
Voltage
Range (VDC)
LDC-185-0500 x
500
300 - 500
200 - 400
420 - 450
200
92
LDC-185-0700 x
700
360 - 700
143 - 286
320 - 350
200
92
LDC-185-1050 x
1,050
600 - 1,050
95 - 190
210 - 240
200
92
LDC-185-1400 x
1,400
750 - 1,400
71 - 143
160 - 170
200
92
LDC-185-3150 x
3,150
1,650 - 3,150
32 - 58
62 - 80
183
91
LDC-185-3850 x
3,850
2,000 - 3,850
32 - 49
54 - 73
189
91
LDC-185-4200 x
4,200
2,200 - 4,200
27 - 42
49 - 65
177
91
LDC-185-5250 x
5,250
2,750 - 5,250
25 - 35
41 - 55
183
91
(%, Typ)
Notes:
1. Inrush current is given for a cold start
at 25°C.
2. Total Harmonic Distortion (THD) is
specified with an input of 230 VAC/50
Hz at full load.
3. Turn on delay is specified at full load.
4. Ripple & noise is measured at 20 MHz.
Connection to the unit is made with a 0.1 µF
ceramic capacitor and a 22 µF electrolytic
capacitor connected in parallel.
5. Life expectancy is calculated at 230 VAC,
full load and a case temp of +70°C.
6. Recovery from an over voltage fault is
automatic.
Package Type
Model
LDC-185-xxxx A
LDC-185-xxxx B
Ingress Protection
IP65
IP67
Dimming Function
Adjust by internal, variable resistor
Adjust by external resistor, DC voltage level or PWM signal
Derating Curve: Temperature
Efficiency vs Load: LDC-185-5250
292 Page Street Ste D Stoughton, MA 02072
Derating Curve: Input Voltage
PFC vs Load: LDC-185-5250
• TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]
www.micropowerdirect.com
Functional Block Diagram
Dimming Mode: B Model
With the LDC-185 “B” model, the output current level can be adjusted (Dimmed) by three different methods; Resistive, Analog or
Digital. Adjustments are made using the +DIM and -DIM inputs.
Resistive: Connect a 0.1 to 10 k resistor between the DIM+ (Blue) and DIM- (White) wires
Input Frequency
10 k
20 k
30 k
40 k
50 k
60 k
70 k
80 k
90 k
100 k
Open
Percentage of Rated Current
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
95~105%
Analog: Apply 1 VDC to 10 VDC level between the DIM+ (Blue) and DIM- (White) wires
Adjust Voltage
Percentage of Rated Current
1 VDC
2 VDC
3 VDC
4 VDC
5 VDC
6 VDC
7 VDC
8 VDC
9 VDC
10 VDC
Open
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
95~105%
Digital: Apply a PWM signal (100 Hz - 3 kHz) between the DIM+ (Blue) and DIM- (White) wires
Duty Cycle
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
Open
Percentage of Rated Current
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
95~105%
Notes:
1. The -DIM (White) and -LED (Black) wires should not be connected.
2. The Dimming function will not turn the lighting fixture totally off. For more info on how to do this, please contact the factory
MicroPower Direct
•
292 Page Street Ste D Stoughton, MA 02072
• TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]
www.micropowerdirect.com
Mechanical Dimensions: A Model
Wire Connections: Input
Wire Connections: Output
Color
Function
Color
Function
Green/Yellow
Brown
Blue
Field Ground
AC-Line
AC-Neutral
Black
Red
-LED
+LED
Mechanical Dimensions: B Model (Dimming Function)
Wire Connections: Input
Wire Connections: Output
Color
Function
Color
Function
Green/Yellow
Brown
Blue
Field Ground
AC-Line
AC-Neutral
White
Blue
-DIM
+DIM
Black
Red
-LED
+LED
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]