FGN Data sheet Sensing element/Gauge ■Features Surface mount package ■Ordering Information FGN-6 07P G SR Terminal leads configuration Surface mount package Model Length of the pressure port 6:6mm Pressure type Rated Pressure (PSI) G:Gauge Pressure Weight (grams) RoHS compliance 0.35 Measurable pressure range(kPa) -13.79 to 13.79 FGN-602PGSR -34.47 to 34.47 FGN-605PGSR -48.26 to 48.26 FGN-607PGSR Part number ■Specifications Model 602PG 605PG 607PG Recommended operating conditions Pressure type Gauge pressure Rated pressure 13.79 34.47 48.26 Measurable pressure range -13.79 to 13.79 -34.47 to 34.47 -48.26 to 48.26 Temperature range 0 to 50 Pressure media Non-corrosive gases only (No liquid) Excitation current (Constant) 1.5 Absolute maximum rating Maximum load pressure Twice of rated pressure Maximum excitation current 3.0 Operating temperature 0 to 80 Storage temperature -20 to 100 Operating humidity 30 to 80 (Non dew condition) Electric characteristics (Drive Current 1.5mA constant ,ambient temperature Ta=25deg.C) Output span voltage 40 to 130 (at 0kPa to rated pressure) Offset voltage +/-25 (at 0kPa) Bridge resistance 4000 to 6000 Response time 2 (for the reference) Accuracy TSO* +/-10 +/-8 TCS* 5.0 2.5 Linearity +/-0.6 +/-0.3 Pressure hysteresis +/-1.0 +/-0.7 *TSO : Temperature sensitivity of offset voltage(Temperature range from 0-50 deg.C) *TCS : Temperature coefficient of output span voltage(Temperature range from 0-50 deg.C) 1 Unit kPa kPa deg.C mADC mADC deg.C deg.C %RH mV mV Ω msec. %FS/0-50deg.C %FS/0-50deg.C %FS %FS FGN Data sheet Sensing element/Gauge P1= 0 kPa P2= 1/2 x P3 (kPa) P3= reted pressure (kPa) T1= 0 deg.C T2= 25 deg.C T3= 50 deg.C Offset voltage (mV) Voff = V(P1,T) Voff(0) = V(P1,T1) Voff(25) = V(P1,T2) Voff(50) = V(P1,T3) Output voltage at full scale (mV) Vfs = V(P3,T) Vfs(0) = V(P3,T1) Vfs(25) = V(P3,T2) Vfs(50) = V(P3,T3) Output span voltage (mV) SV = Vfs - Voff SV(0) = Vfs(0) - Voff(0) SV(25) = Vfs(25) - Voff(25) SV(50) = Vfs(50) - Voff(50) Temperature sensitivity of offset voltage (%FS) TSO = {LARGER ONE} / SV(25) x 100 LARGER ONE = larger absolute value which of {Voff(0)-Voff(25)} and {Voff(50)-Voff(25)} Temperature coefficient of output span voltage (%FS) TCS = {max[SV(0),SV(25),SV(50)] - min[SV(0),SV(25),SV(50)] } / SV(25) x 100 Linearity (%FS) NL = {V(P2,T2) - [Voff(25)+Vfs(25)]/2 } / SV(25) x 100 Pressure hysteresis (%FS) Phys = {Voff’(25) - Voff(25) } / SV(25) x 100 Voff’(25) : Output voltage against P1 after stressing by P3 pressure. 2 FGN Data sheet Sensing element/Gauge ■Outline dimensions■ FGN 2-φ1.1 ■Connection diagram■ 3 FGN Data sheet Sensing element/Gauge ■Output characteristics■ ↑Output voltage(mV) Output span voltage Offset voltage -Rated pressure 0kPa Atomospheric pressure Note ; Rated pressure →Pressure(kPa) Please read instruction “Notes” before using the sensor. Fujikura reserves the right to change specifications without notice. Please keep the sensors sealed using static shielding bags on storage.The pins of the sensor are plated by Ag. If the sensors expose to an atmosphere, the pins will be black by sulfuration. Please set Zero-calibration function up your products. The offset voltage may be shifted some mechanical stress such as mounting, installation and etc. over longtime using. 4 FGN Data sheet Sensing element/Gauge Reflow Soldering process recommendation profile Package Surface Temperature (Degree C) 230 210 150 Room Temp. Time a a: Rump up rate b: Pre-heating c: Rump up rate d: Heating e: Rump down rate Note ; b c d e 1 or 2 deg.C/sec. 150 to 180 deg.C,within 60 to120sec. 1 to 2 deg.C/sec. max.230 deg.C,max.10sec. 210 deg.C,within 30sec. 1 or 2 deg.C/sec. 1 ) Temperature means Surface temperature of the sensor package. 2 ) Reflow process max. 2 times. 3 ) Do not wash the sensor. 4 ) Do not put the solder and flux on the sensor package. If you have any questions regarding technical issues or specifications, please contact us. Fujikura Ltd. Sensor Department 5-1 Kiba 1-chome, Koto-ku, Tokyo 135-8512, Japan Phone +81-(0)3-5606-1072 E-mail : [email protected] 5