EPIGAP ELD-1300-525 Led - lamp Datasheet

LED - Lamp
ELD-1300-525
15.11.2007
rev. 05
Radiation
Type
Technology
Case
Infrared
MQW
InGaAs/InP
5 mm plastic lens
Description
High-power, high-speed infrared LED in standard
5 mm package, housing without standoff leads
8,6
5,75 - 0,3
1
2,54
0,8 - 0,4
Anode
Note: Special packages with standoff available on request
Applications
1,5
0,6 - 0,2
36,5
± 1,0
Ø5
Optical communications, safety equipment,
automation
Maximum Ratings
Tamb = 25°C, unless otherwise specified
Parameter
Test сonditions
Symbol
Value
Unit
IF
100
mA
IFM
200
mA
PD
150
mW
Operating temperature range
Tamb
-20 to +80
°C
Storage temperature range
Tstg
-55 to +100
°C
Tsd
260
°C
Typ
Max
Unit
VF
0.85
1.0
V
0.95
Forward current (DC)
(tP ≤ 50 µs, tP /T = 1/2)
Peak forward current
Power dissipation
t ≤ 5 s, 3 mm from case
Soldering temperature
Optical and Electrical Characteristics
Tamb = 25°C, unless otherwise specified
Test
Parameter
conditions
IF = 20 mA
Forward voltage
Symbol
Min
Forward voltage*
IF = 100 mA
VF
Reverse voltage
IR = 100 µA
VR
5
Radiant power
IF = 20 mA
Φe
1.6
Radiant power*
IF = 100 mA
Radiant intensity
V
V
2.2
mW
Φe
8.5
mW
IF = 20 mA
Ιe
10
mW/sr
Radiant intensity*
IF = 100 mA
Ιe
38
mW/sr
Peak wavelength
IF = 20 mA
λp
Spectral bandwidth at 50%
IF = 20 mA
∆λ0.5
70
nm
Viewing angle
IF = 20 mA
ϕ
25
deg.
Switching time
IF = 20 mA
tr, tf
10
ns
1250
1300
1350
nm
*measured after 30s current flow
Note: All measurements carried out on EPIGAP equipment
We reserve the right to make changes to improve technical design and may do so without further notice.
Parameters can vary in different applications.All operating parameters must be validated for each customer application by the customer.
EPIGAP Optoelektronik GmbH, D-12555 Berlin, Köpenicker Str.325 b, Haus 201
1 of 3
Tel.: +49-30-6576 2543, Fax : +49-30-6576 2545
LED - Lamp
ELD-1300-525
15.11.2007
Spectral power distribution (typical)
at IF = 20 mA
rev. 05
Typical wavelength shift vs. forward current
(rel. to λP @ IF = 20 mA)
1,0
0,8
Wavelength shift (nm)
rel. Intensity (arb. units)
6
0,6
0,4
4
2
0,2
0
0,0
800
1000
1200
1400
Wavelength (nm)
1600
1800
0
20
40
60
80
100
IF (mA)
We reserve the right to make changes to improve technical design and may do so without further notice.
Parameters can vary in different applications.All operating parameters must be validated for each customer application by the customer.
EPIGAP Optoelektronik GmbH, D-12555 Berlin, Köpenicker Str.325 b, Haus 201
2 of 3
Tel.: +49-30-6576 2543, Fax : +49-30-6576 2545
LED - Lamp
ELD-1300-525
15.11.2007
rev. 05
Remarks concerning optical radiation safety*
Up to maximum forward current, at continuous operation, this LED may be classified as LED product
Class 1 , according to standard IEC 60825-1:A2. Class 1 products are safe to eyes and skin under
reasonably predictable conditions. This implicates a direct observation of the light beam by means of
optical instruments.
*Note: Safety classification of an optical component mainly depends on the intended application and
the way the component is being used. Furthermore, all statements made to classification are based
on calculations and are only valid for this LED "as it is", and at continuous operation. Using pulsed
current or altering the light beam with additional optics may lead to different safety classifications.
Therefore these remarks should be taken as recommendation and guideline only.
LED Class 1
accord. DIN EN/IEC 60825-1:2001-11
We reserve the right to make changes to improve technical design and may do so without further notice.
Parameters can vary in different applications.All operating parameters must be validated for each customer application by the customer.
EPIGAP Optoelektronik GmbH, D-12555 Berlin, Köpenicker Str.325 b, Haus 201
3 of 3
Tel.: +49-30-6576 2543, Fax : +49-30-6576 2545
Similar pages