MORNSUN LS03-15B05SR2S Ac/dc converter Datasheet

AC/DC Converter
LS03-15BXXSR2S(-F) Series
FEATURES
3W, AC/DC converter
Wind input voltage: 85~264VAC/70~400VDC
Over current protection and short circuit protection
High efficiency, high power density
Low power consumption, green power
Industrial grade
Open frame, urtal-slim SIP package
Flexible design of peripheral circuit reduces layout
problems
z Meets IEC60950/EN60950/UL60950
z
z
z
z
z
z
z
CB RoHS
E235235
Model marking with number, such as “0312”means“LS03-15B12SR2S
LS03-15BXXSR2S series is a high efficiency green power modules provided by Mornsun. The features of this series are: Accept either AC or DC
input, wide input voltage, high efficiency, low loss, safety isolation etc. All models are particularly suitable for the applications such as
industrial, electric power, instrumentation, smart home which do not have high requirement on EMC.EMC application circuit must be added
if the products need to be applied to EMC harsh environment .
Selection Guide
Model
Output Power
Nominal Output Voltage
and Current(Vo/Io)
Efficiency
(230VAC,%/Typ.)
Max. Capacitive Load
(uF)
LS03-15B03SR2S(-F)*
1.65W
3.3V/500mA
63
470
LS03-15B05SR2S(-F)
2.5W
5V/500mA
68
470
9V/333mA
75
150
12V/250mA
77
100
15V/200mA
78
100
24V/125mA
80
100
Certification
UL/CE
LS03-15B09SR2S(-F)
LS03-15B12SR2S(-F)
3W
LS03-15B15SR2S(-F)
LS03-15B24SR2S(-F)
Note: *The model of 90 degrees of corner is with -F. For example the LS03-15B12SR2S of 90 degrees of corner product is LS03-15B12SR2S-F.
Input Specifications
Item
Operating Conditions
Input Voltage Range
Min.
Typ.
Max.
AC input
85
--
264
VAC
DC input
70
--
400
VDC
47
--
440
Hz
115VAC
--
--
0.12
230VAC
--
--
0.06
115VAC
--
13
--
230VAC
--
23
--
Input frequency
Input current
Inrush current
Unit
A
Output Specifications
Item
Operating Conditions
Output Voltage Accuracy
Min.
Typ.
Max.
LS03-15B03SR2S(-F)
①
--
--
±8
LS03-15B05SR2S(-F)
②
--
--
LS03-15B09SR2S(-F)
--
--
LS03-15B12SR2S(-F)
--
--
LS03-15B15SR2S(-F)
--
--
±5
Unit
%
LS03-15B24SR2S(-F)
Line Regulation
Full load
--
±1.5
--
Load Regulation
5%-100% load
--
±2.5
--
LS03-15B03SR2S(-F)/ LS03-15B05SR2S(-F)
--
70
LS03-15B09SR2S(-F)/LS03-15B12SR2S(-F)/
LS03-15B15SR2S(-F)/ LS03-15B24SR2S(-F)
--
50
Output Ripple & Noise
③
20MHz bandwidth
(peak-peak value)
150
2014.03.13-A/1
mV
Page 1 of 6
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
AC/DC Converter
LS03-15BXXSR2S(-F) Series
Temperature Drift
--
Stand-by Power
--
Short Circuit Protection
--
%/°C
--
0.5
W
Continuous, self-recovery
≥110%lo self-recovery
Over-current Protection
10
Min. Load
Hold-up Time
±0.15
--
--
115VAC input
20
--
--
230VAC input
80
--
--
%
ms
Note: ①②.When LS03-15B03SR2S and LS03-15B05SR2S working in -20℃~-40℃ and 55℃~85℃temperature range output filter capacitor C2 need
270μF/16Vsolid-state capacitor.
③.Ripple and Noise measuring refer to “ripple and noise measure figure”, please see AC-DC Converter Application Notes for specific operation
methods.
General Specifications
Item
Operating Conditions
Min.
Test time: 1min
3000
--
--
Operating Temperature
-40
--
+85
Storage Temperature
-40
Max. Product Surface Temperature
--
Isolation Voltage
Input-output
Typ.
Max.
---
Unit
VAC
+105
℃
+90
Storage Humidity
--
--
85
%RH
Switching Frequency
--
--
60
kHz
Power Derating
-40℃~-20℃
2
--
--
+55℃~+85℃
1.33
--
--
Safety Standard
IEC60950/EN60950/UL60950
Safety-regulated Certification
IEC60950/EN60950/UL60950
Safety Class
CLASS II
Hot Plug
Unavailable
MTBF
MIL-HDBK-217F@25°C > 300,000 h
%/℃
Physical Specifications
Package Dimensions
35.00*18.00*11.00mm
Weight
7 g(Typ)
Cooling method
Free air convection
EMC Specifications
Conducted Disturbance
EMI
Radiated Emission
CISPR22/EN55022, CLASS B (See Fig. 2 for recommended circuit)
CISPR22/EN55022, CLASS A (See Fig. 1 for recommended circuit)
CISPR22/EN55022, CLASS B (See Fig. 2 for recommended circuit)
Electrostatic Discharge
IEC/EN61000-4-2
±4KV
Perf. Criteria B
Radiation Immunity
IEC/EN61000-4-3
10V/m (See Fig. 2 for recommended circuit)
perf. Criteria A
IEC/EN61000-4-4
±2KV (See Fig. 1 for recommended circuit)
perf. Criteria B
IEC/EN61000-4-4
±4KV (See Fig. 2 for recommended circuit)
perf. Criteria B
Surge Immunity
IEC/EN61000-4-5
circuit)
±1KV/2KV(See Fig. 1 or Fig. 2 for recommended
Conducted Disturbance
immunity
IEC/EN61000-4-6
10 Vr.m.s(See Fig. 2 for recommended circuit)
perf. Criteria A
Immunity for Power
IEC/EN61000-4-8
10A/m
perf. Criteria A
Immunities of voltage dip,
drop and short interruption
IEC/EN61000-4-11
EFT
EMS
CISPR22/EN55022, CLASS A (See Fig. 1 for recommended circuit)
0%-70%
perf. Criteria B
perf. Criteria B
1
2014.03.13-A/1
Page 2 of 6
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
AC/DC Converter
LS03-15BXXSR2S(-F) Series
Temperature Dera ting Graph
Output Power Percentag e(%)
Output Power Percentag e(%)
Product Characteristic Curve
10 0
80
60
Inp ut v oltage: 11 0~24 0VA C
100 ~34 0VDC
40
-40
55
-20
85
Inp ut Voltage D erating Gra ph
10 0
80
Ambient temp erature:25℃
60
40
Ambient Temperature(℃ )
70
10 0
34 0
40 0 VDC
85
11 0
24 0
26 4 VA C
Inp ut Voltage( V)
Note: Input volt age should be derated based on temperature derating
when it is 85~110VAC /240~264VAC/70~100VDC/340~400VDC.
84
LS03-15BXXSR2S(-F) AC Input
Efficiency Vs Input Voltage (Full Load)
90
85
82
80
LS03-15B24SR2S(-F)
78
76
Efficiency(%)
Efficiency(%)
LS03-15B12SR2S(-F) AC Input
Efficiency Vs Output Load
LS03-15B12SR2S(-F)
74
72
70
80
110VAC
75
230VAC
70
65
60
55
50
68
45
LS03-15B05SR2S(-F)
66
85
110
120
220
230
240
40
10
264
20
LS03-15BXXSR2S(-F) DC Input
Efficiency Vs Input Voltage (Full Load)
40
50
60
70
80
90
100
LS03-15B12SR2S(-F) DC Input
Efficiency Vs Output Load
90
82
85
80
80
200VDC
78
LS03-15B24SR2S(-F)
75
300VDC
76
LS03-15B12SR2S(-F)
Efficiency(%)
Efficiency(%)
84
30
Output Power Percentage(%)
Input Voltage(VAC)
74
72
70
100
150
200
250
300
350
60
55
45
66
70
65
50
LS03-15B05SR2S(-F)
68
70
40
400
10
Input Voltage(VDC)
20
30
40
50
60
70
80
90
100
Output Power Percentage(%)
Design Reference
1. Typical application circuit
FUSE
AC(L)
MOV 1
AC(N)
NT C
L2
C1
+
3
+Vo
12
5 ACDC
7
1
①
C2
L1
+
C3 TVS C4 RL
+
10
-Vo
CY0
Fig. 1: Typical application circuit
Note: ①is Pi filter circuit.
2014.03.13-A/1
Page 3 of 6
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
AC/DC Converter
LS03-15BXXSR2S(-F) Series
FUSE
(Required)
Model
NTC
MOV1
C1
(Required)
C2
(Required)
L2
L1
(Required)
C3
(Required)
LS03-15B03SR2S(-F)
LS03-15B12SR2S(-F)
CY0
120μF/25V
LS03-15B05SR2S(-F)
LS03-15B09SR2S(-F)
C4
SMBJ
7.0A
330μF/ 35V
1A/
250V
13D5
S14K3
20
10μF/
400V
2.2
μH
5mH
150μF/ 35V
LS03-15B15SR2S(-F)
LS03-15B24SR2S(-F)
TVS
0.1
μF/
50
V
68μF/35V
1nF/
400
VAC
SMBJ
12A
SMBJ
20A
SMBJ
30A
100μF/ 35V
Note:
1. C1,C2and C3 are electrolytic capacitors. They are required both AC input and DC input.
The value of C1 is recommended to be 10μF /400V . When the input voltage is above 370VDC, the recommended value of C1 is 10μF/450V).C2 and C3 are
output filer capacitors, they are recommended to be high frequency and low impedance electrolytic capacitors. Capacitance and rated ripple current of
capacitors refer to the datasheets provided by the manufactures. Voltage derating of capacitors should be 80% or above. C4 is a ceramic capacitor, which is
used to filter high frequency noise. C2,C3 and L1 form a pi-type filter circuit. Current of L1 and L2 refer to the datasheets provided by the manufactures, current
derating should be 80% or above. TVS is a recommended component to protect post-circuits (if converter fails).
2. EMC solution-recommended circuit
Can use MORNSUN’S FC-L01DV1
AC(L)
NTC
FUSE
LDM
LCM
M OV 2
L1
AC(L)
CY1
CX
CY2
C1
+
5
ACDC
7
+
C2
+
C4
RL
C3
-Vo
10
AC(N)
AC(N)
TVS
12
+Vo
CY0
Fig 2: EMC application circuit with higher requirements
Fig 3: Recommended EMC circuit-PCB layout
Suggestions for safety regulation and wiring width: wire width ≥3mm, distance between wires ≥6mm, and distance between wire and
ground ≥6mm, A≥6.4mm
Components
Recommend Parameter
MOV2
S14K320
CY1
1nF/400VAC
CY2
1nF/400VAC
CX
0.1μF/275VAC
LCM
3.5mH
LDM
0.3mH
FC-L01DV1
MORNSUN’s 1KV/2KV Surge protector
FUSE(Required)
1A/250V, slow fusing
3. For more information please find application notes on www.mornsun-power.com
2014.03.13-A/1
Page 4 of 6
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
AC/DC Converter
LS03-15BXXSR2S(-F) Series
LS03-R2S Dimensions and Recommended Layout
LS03-R2S-F Dimensions and Recommended Layout
2014.03.13-A/1
Page 5 of 6
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
AC/DC Converter
LS03-15BXXSR2S(-F) Series
Note:
1. Packing Information please refer to 'Product Packing Information'. Packing bag number: 58220018(LS03-15BXXSR2S)/58220025
(LS03-15BXXSR2S-F);
2. External electrolytic capacitors are required to modules, more details refer to typical applications;
3. This part is open frame, at least 6.4mm safety distance between the the primary and secondary external components of the module is
needed to meet the safety requirement;
4. All specifications were measured at Ta=25°C, humidity<75%, nominal input voltage (115VAC or 230VAC)and rated output load unless
otherwise specified;
In order to increase the conversion efficiency of the product with light load in the design, the product will have slight audio noise when
operating with load less than 30% of rated load, but it will not affect the product's reliability and performance;
6. Module required dispensing fixed after assembled;
7. Recommends placing the insulation sheet between the bottom of the curved legs Module (LS03-R2S-F) and the PCB board,
recommended materials for the FR700, thickness is more than 0.4mm.
8. All index testing methods in this datasheet are based on our Company’s corporate standards;
9. We can provide product customization service;
10. Specifications of this product are subject to changes without prior notice.
5.
Mornsun Guangzhou Science & Technology Co., Ltd.
Address: No. 5, Kehui St. 1, Kehui Development Center, Science Ave., Guangzhou Science City, Luogang District, Guangzhou, P. R. China
Tel: 86-20-38601850-8801
Fax: 86-20-38601272
E-mail: [email protected]
2014.03.13-A/1
Page 6 of 6
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
Similar pages