Power Systems MUS-2409 Dc-dc converter unit 1 w unregulated dc-dc converter Datasheet

DC-DC Converter UNIT
MU Series ( 1 W UNREGULATED DC-DC CONVERTER )
FEATURES
z
z
1000VDC ISOLATION
EFFICIENCY UP TO 82%
INTERNAL SMD TECHNOLOGY
LOW COST
NO HEATSINK REQUIRED
UP TO 1W UNREGULATED
OUTPUT POWER
SINGLE IN LINE PACKAGE
100% BURNED IN
z
MTBF > 2,000,000 HOURS
z
OUTPUT SPECIFICATIONS
z
z
z
z
z
z
z
Voltage Setpoint Accuracy
+/-2% max
Temperature Coefficient
+/-0.03%/ OC
Ripple & Noise (20MHz
INPUT SPECIFICATIONS
Input Voltage Range
Input Filter
+/-10% max
Capacitor Type
100mVp-p max
BW)
Line Regulation1
Load Regulation
+/-1.2% max
2
+/-8% max
Short Circuit Protection
z
Momentary
ENVIRONMENTAL SPECIFICATIONS
Operating Temperature
Storage Temperature
Cooling
z
GENERAL SPECIFICATIONS
Efficiency
70%-82%
Isolation Voltage3
1000 VDC min
Isolation Resistance
9
10 ohms min
-25 OC to +71 OC
Switching Frequency
100 KHz min
-55 OC to +125 OC
Isolation Capacitance
80pF max
Free-Air Convection
MTBF
Weight
2,000,000 Hours
1.3g Typ
ALL SPECIFICATIONS TYPICAL AT NOMINAL
Case Material
Non-Conductive Plastic
LINE,
Case Size
11.6mm*6.1mm*10.2mm
FULL
LOAD
,
AND
25
O
C
UNLESS
OTHERWISE NOTED.
11.6mm*7.6mm*10.2mm
1
Line Regulation is for a 1.0% change in input Voltage.
2
Load Regulation is for output load current change from 20% to 100%.
3
For 60 seconds
www.Power-Systems.de
Page: 1 / 5
Version: 4-Oct-02
DC-DC Converter UNIT
MU Series ( 1 W UNREGULATED DC-DC CONVERTER )
z SELECTION GUIDE
1W OUTPUT
MODEL
NUMBER
INPUT
OUTPUT
OUTPUT
VOLTAGE VOLTAGE CURRENT
(VDC)
(VDC)
(mA)
INPUT
CURRENT(mA) EFF
FULL
NO
LOAD
LOAD
ISOLATION
(%)
(VDC)
PACKAGE
MUS-0505
5
5
200
274
26
73
1000
A
MUS-0509
5
9
110
260
27
77
1000
A
MUS-0512
5
12
84
253
26
79
1000
A
MUS-0515
5
15
67
253
28
79
1000
A
MUS-1203.3
12
3.3
300
112
11
74
1000
B
MUS-1205
12
5
200
112
11
74
1000
A
MUS-1209
12
9
110
105
11
79
1000
A
MUS-1212
12
12
84
102
11
82
1000
A
MUS-1215
12
15
67
102
12
82
1000
A
MUS-2403.3
24
3.3
300
57
8
73
1000
B
MUS-2405
24
5
200
57
8
73
1000
B
MUS-2409
24
9
110
54
8
77
1000
B
MUS-2412
24
12
84
54
8
77
1000
B
MUS-2415
24
15
67
52
7
80
1000
B
Note: Other input to output voltages may be available. Please contact factory.
www.Power-Systems.de
Page: 2 / 5
Version: 4-Oct-02
DC-DC Converter UNIT
MU Series ( 1 W UNREGULATED DC-DC CONVERTER )
z MECHANICAL DIMENSIONS
PACKAGE ”A”
PIN
SINGLE
1
-Vin
2
+Vin
3
-Vout
4
+Vout
PACKAGE ”B”
www.Power-Systems.de
Page: 3 / 5
PIN
SINGLE
1
-Vin
2
+Vin
3
-Vout
4
+Vout
Version: 4-Oct-02
DC-DC Converter UNIT
MU Series ( 1 W UNREGULATED DC-DC CONVERTER )
z RECOMMENDED FOOTPRINT DETAILS
PACKAGE "A"
PACKAGE "B"
z SIMPLIFIED SCHEMATIC
z TYPICAL APPLICATIONS
INPUT
+Vin
OUTPUT
+Vout
+Vin
+Vout
OSCILLATOR
DRIVER
LOAD
DC-DC
CONVERTER
-Vout
-Vin
-Vin
-Vout
z TYPICAL PERFORMANCE CUREVES
Specifications typical at ta=25 OC , nominal input voltage , rated output current unless otherwise specified.
DERATING CURVE
1.2
80.0
60.0
40.0
20.0
0.0
0
20
40
60
80
100
OUTPUT POWER(W)
EFFICIENCY(%)
EFFICIENCY VS LOAD
0.9
0.3
0.0
-25
0
25
50
70
100
TA(degree C)
% OF RATED LOAD(%)
www.Power-Systems.de
SAFE
OPERATING
AREA
0.6
Page: 4 / 5
Version: 4-Oct-02
DC-DC Converter UNIT
MU Series ( 1 W UNREGULATED DC-DC CONVERTER )
MU SERIES APPLICATION NOTES:
EXTERNAL CAPACITANCE REQUIREMENTS:
Output filtering is required for operation. A minimum of 10uF is needed. Output
capacitance may be increased for additional filtering, not to exceed 220uF.
To meet the reflected ripple requirements of the converter, an input impedance of
less than 0.5 ohm from DC to 250KHz is required.
Negative Outputs:
A negative output voltage may be obtained by connecting the +OUT to circuit ground
and connecting –OUT as the negative output.
FOR MORE INFORMATION CALL:
Power Systems – The Power Solution
Ilsfeld-Auenstein ( Germany ) Dörnet 8
Tel: + 49 / 70 62 / 67 59 – 6
E-mail: [email protected]
Home Page: www.Power-Systems.de
www.Power-Systems.de
Page: 5 / 5
Fax: + 49 / 70 62 / 67 59 -80
Version: 4-Oct-02