Energy Management 3-channel Power Transducer Type APT-DIN • Measurement of: kW • 9 selectable full-scales in 9 intervals from 0 to 5 (range from 0,4kW to 3,6kW) • Degree of protection (front): IP 50 • 3 analogue outputs (0 to 10VDC) • Response time: ≤50ms Product Description Ordering Key APT-DINAV53G3 2 1 ing range from 0,4 to 3,6kW) The house is for DIN-rail mounting and ensures a degree of protection (front) of IP 50. Model Range code System Power supply Rated outputs Number of inputs Calibration Range code System Power supply Rated outputs AV5: 3: D: 230VAC –15+10% 50/60Hz 3: G: 400VAC –15+10% 50/60Hz Active power transducer with auxiliary power supply of 400VAC (phasephase connection). 9 measuring ranges selectable in 9 intervals from 0 to 5 (measur- Type Selection 400 VAC - 5,2 AAC (max. 480 V (L-L) 6,2 A) (standard) Three phase system (3 wires, balanced/ unbalanced load) Number of inputs Calibration 2: 1: 2 x (3-phase inputs) 3 x (0 to 10VDC) 3600W. Input Specifications Rated inputs Accuracy Active power (@ 25°C ± 5°C, R.H. ≤ 60%) Additional errors Humidity Input frequency Magnetic field Ripple 2 (3-phase inputs) for current and voltage measurements ±3% rdg (cos ϕ 0.7 L/C, 0.5 to 1Ph) < 0.5%, 60% to 90% R.H. < 0.5%, 50 to 60 Hz < 0.5% @ 400 A/m balanced load: ≤1% according to IEC 60688-1 and Measurement Ranges (impedances) AV5: Frequency range Over-load protection Continuous: voltage/current For 1 s Voltage: Current: EN 60 688-1 unbalanced load: ≤5% kW 400VAC (≤2W per channel) 5.2AAC (≤0.3 VA per channel) 48 to 62 Hz 1.2 x rated input 2 x rated input 20 x rated input Output Specifications Analogue outputs Number of outputs Range Response time Temperature drift Load: 10 V output 3 (one per channel) 0 to 10 VDC ≤ 50 ms typical ±500 ppm/°C ≥ 10 kΩ Specifications are subject to change without notice Analogue outputs Insulation APT-DIN 3 DS0603 By means of optocouplers, 2000 Vrms output to measuring input / power supply 1 APT-DIN Supply Specifications AC voltage 400 VAC (standard), -15%+10% 50/60 Hz 230VAC (optional) –15+10% 50/60Hz Power consumption ≤ 7 VA General Specifications Operating temperature Storage temperature Insulation reference voltage Insulation Dielectric strength -20 to +60°C (–4 to 140°F) (R.H. < 90% non-condensing) -30 to +80°C (–22 to 176°F) (R.H. < 90% non-condensing) 300 Vrms to ground (with neutral connection), CAT II (double insulation), CAT III (main insulation) Pollution degree 2 4000 Vrms between all inputs/ outputs to ground 4000 Vrms for 1 minute Noise rejection CMRR EMC Safety standards Safety requirements: Products requirements: Connector Housing Dimensions Material Degree of protection Weight 100 dB, 48 to 62 Hz EN 50081-1, EN 50082-1 IEC 61010-1, EN 61010-1 IEC 60688-1, EN 60688-1 Screw-type, max. 4 mm2 wires 115 x 76 x 100 mm ABS, self-extinguishing: UL94 V-0 Front: IP50 Approx. 810 g (packing included) Front Panel Description Wiring Diagrams Three-phase, 3-wire ARON input connections - Unbalanced loads 4 1 2 3 CT connection (3-wire system) 1. Rotary switch 9-position rotary switch for input full scale selection (at every selected input full scale correspond a 10VDC output) . 2. LED Power-ON. 3. Connection terminal blocks 4. Connection terminal blocks Dimensions 2 APT-DIN 3 DS0603 Specifications are subject to change without notice