The ABC201 Series of open-frame power supplies, with its wide universal 90-264 VAC input range and high power density, is available at 200 W of output power and a variety of single output voltages. The high efficiency and high power density of the ABC family ensures minimal power loss in end-use equipment, thereby facilitating higher reliability, easier thermal management and meets regulatory approvals for environmentally-friendly end products. These power supplies are ideal for telecom, datacom, industrial equipment and other applications. • 5 x 3 x 1.5 Inch Form Factor • 200 W with Forced-Air Cooling • High Efficiency > 88% • 12 V Fan & 5 V Standby Outputs • Remote Sense • Output Voltage Adjustability • IEC Protection Class Options: • Class I: Earthing Tab J4 (no suffix) • Class II: No Earthing Tab (-2 suffix) • RoHS Compliant • CE Marked • Instrumentation • Renewable Energy • Lighting • Test and Measurement • Industrial Applications • Robotics • Applied Computing • Wireless Communication ABC201 Series 2 CONNECTOR OUTPUT VOLTAGE MAX LOAD CONVECTION 2 MAX LOAD 300 LFM 2, 3, 4 MINIMUM LOAD RIPPLE & NOISE 5 ABC201-1005G JST 5.0 VDC 26.0 A 26.0 A 0.0 A 1% ABC201-1T05G Screw Terminal 5.0 VDC 26.0 A 35.0 A 0.0 A 1% ABC201-1012G JST 12 VDC 13.33 A 16.67 A 0.0 A 1% ABC201-1T12G Screw Terminal 12 13.33 A 16.67 A 0.0 A 1% ABC201-1015G JST 15 10.66 A 13.33 A 0.0 A 1% ABC201-1T15G Screw Terminal 15 10.66 A 13.33 A 0.0 A 1% ABC201-1024G JST 24 6.66 A 8.33 A 0.0 A 1% ABC201-1T24G Screw Terminal 24 6.66 A 8.33 A 0.0 A 1% ABC201-1030G JST 30 5.33 A 6.66 A 0.0 A 1% ABC201-1T30G Screw Terminal 30 5.33 A 6.66 A 0.0 A 1% ABC201-1048G JST 48 3.33 A 4.17 A 0.0 A 1% ABC201-1T48G Screw Terminal 48 3.33 A 4.17 A 0.0 A 1% MODEL1 COVER-201-XBC 6 Metal cover kit accessory Specifications are for nominal input voltage, 25°C unless otherwise stated. PARAMETER DESCRIPTION / CONDITION SPECIFICATION Input Voltage Universal 90-264 VAC / 120-390 VDC Input Frequency Input Current Inrush Current Leakage Current Power Factor Switching Frequency 47 to 63 Hz 120 VAC: 230 VAC: 120 VAC: 230 VAC: 120 VAC: 230 VAC: 120 VAC: 230 VAC: PFC converter (variable) Resonant converter (variable) 2.4 A max. 1.2 A max. 35 A max. 65 A max. < 150 µA < 300 µA 0.99 0.95 35 to 250 kHz, 90 kHz typical 35 to 250 kHz, 90 kHz typical 1 For Class II (without input Earth pin) add suffix -2 (e.g.: ABC201-1012G-2). Combined output power from V1, VSTBY and VFAN should not exceed the total output power rating. 3 Fan output voltage tolerance is +/-20%. During V1 full load, VFAN needs min. 20 mA load to be within regulation band. 4 Peak current for fan output is 1 A. 5 Ripple is 2% up to 20% load and < 1% above 20% load. Ripple is peak to peak with 20 MHz bandwidth and 10 µF (Tantalum capacitor) in parallel with a 0.1 µF capacitor at rated line voltage and load ranges. 6 When used in Cover Kit, de-rate output power to 70 % under all operating conditions. 2 [email protected] ABC201 Series PARAMETER Efficiency Hold Up Time Output Power 3 DESCRIPTION / CONDITION SPECIFICATION 120 VAC: 230 VAC: 120 / 230 VAC 84% typical 86% typical 10 ms 160 W to 200 W Derate output power linearly to 80% from 90 V to 80 VAC input. Peak Power: 250 W for 0.2 s Line Regulation +/-0.5% Load Regulation Transient Response +/-2.0% < 10%, recovery time < 5 ms < 100 ms Main output 50 to 100% load change, 50 Hz, 50% duty cycle, 0.1A / µs Rise Time Set Point Accuracy ± 1% Voltage Adjustment V1 ±3% Over Voltage Protection V1 only 110 to 150 % Over Current Protection Short Circuit Protection 110% typical above rating Short term, auto recovery PARAMETER Operating Temperature DESCRIPTION / CONDITION Refer to derating curve (Figure 1) SPECIFICATION -20 to 70°C -20 to 0°C Start-up is guaranteed Storage Temperature -40 to 70° C 5 V model Cooling Other models Convection: 300 LFM: Convection: 300 LFM: 130 W 175 W 160 W 200 W Humidity Non Condensing 95% Altitude Operating: Non-Operating: 10,000 ft. 40,000 ft. Reliability MTBF according to Telcordia –SR332-Issue 3 1.6 million hours Conducted Emissions EN55032-B, CISPR22-B, FCC PART15-B Pass Radiated Emissions EN 55032 A; with external core (King core K5B RC 25x12x15-M in input cable) Pass Level B Input Current Harmonics EN 61000-3-2 Class D Voltage Fluctuation and Flicker EN 61000-3-3 Pass ESD Immunity EN 61000-4-2 Level 3, Criterion A Radiated Field Immunity EN 61000-4-3 Level 3, Criterion A Electrical Fast Transient Immunity EN 61000-4-4 Level 3, Criterion A Surge Immunity EN 61000-4-5 Level 3, Criterion A Conducted Immunity EN 61000-4-6 Level 3, Criterion A Magnetic Field Immunity EN 61000-4-8 Level 3, Criterion A Voltage Dips, Interruptions EN 61000-4-11 Criterion A & B Europe, Middle East +353 61 225 977 North America +1 408 785 5200 © 2017 Bel Power Solutions & Protection BCD.00284_AE Asia-Pacific +86 755 298 85888 ABC201 Series 4 PARAMETER DESCRIPTION / CONDITION SPECIFICATION Isolation Voltage Input to Output: Min. VDC Safety Standards Approved to the latest edition of the following standards: CSA/UL60950-1, EN60950-1 and IEC60950-1 Agency Approvals Nemko, UL, C-UL CE mark Complies with LVD Directive PARAMETER DESCRIPTION / CONDITION Power Good Signal TTL signal goes high after main output is in regulation band. Delay is 0.1 to 0.3 sec. Power Fail Signal TTL signal goes low 1 ms advance before output goes out of regulation due to mains failure Remote ON / OFF To turn-on power supply short J3 pin 4 to pin 6 (PSU is shipped in this configuration) Remote Sense Compensates for 200 mV cable drop CONNECTOR PIN DESCRIPTION / CONDITION Pin 1 AC Neutral Pin 2 AC Line AC Input Connector J1 DC Output Connector J2 Pin 1,2,3 Pin 4,5,6 RTN Vout Signals & Aux Power7 J3 Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 Pin 7 Pin 8 +VE Remote Sense VFAN (+12 V/0.5 A) -VE Remote Sense Remote ON/OFF VSTBY (+5 V/1 A, +/-5%) RTN (Signal) Power Fail Power Good Earthing Tab J4 MANUFACTURER / PN Molex: 26-60-4030 or equivalent; Mating: 09-50-3031; Pins: 08-50-0106 Option 1: Tyco: 2-1776112-3 or equivalent Mating: 13 AWG wire Option 2: JST: B6P-VH-B (LF) (SN) or B6P-VH (LF) (SN) or equivalent Mating: VHR-6M; Pins: SVH-41T-P1.1 Molex: 22-23-2081 or equivalent Mating: 22-01-2087, Pins: 08-50-0113 Molex: 19705-4301 or equivalent Mating: 190030001 PARAMETER DESCRIPTION / CONDITION Weight 325 g (0.72 lbs.) Dimensions 127.0 x 76.2 x 38.1 mm (5 x 3 x 1.5 inch) Cooling Convection: 83 W; 300 LFM: 175 W (5 V model) Convection: 160 W; 300 LFM: 200 W (other models) 7 PSU is supplied with J3 housing, pin-4 and pin-6 shorted to enable main output without remote on/off feature. [email protected] ABC201 Series 5 Convection load: 83 W up to 40 °C De-rate above 40 °C @ 1.89% per °C Forced air cooled load: 130 W up to 50°C (for screw terminal version) De-rate above 50 °C @ 1.63% per °C Forced air cooled load: 175 W up to 50°C (for JST connector version) De-rate above 50 °C @ 2.5% per °C Convection load: 160 W up to 40 °C De-rate above 40 °C @ 2% per °C Forced air cooled load: 200 W up to 50°C De-rate above 50 °C @ 2.5% per °C Figure 1. Derating Curves Europe, Middle East +353 61 225 977 North America +1 408 785 5200 © 2017 Bel Power Solutions & Protection BCD.00284_AE Asia-Pacific +86 755 298 85888 ABC201 Series 6 Figure 2 - Mechanical Drawing 1 2 3 NOTES: In case the PCB is mounted in a metal enclosure, using metal hardware ensure the following: Stand off, used to mount PCB has OD of 5.4 mm max. Screws, used to fix PCB on stand off, have head dia of 6.0 mm max. Washer, if used, to have dia of 6.5 mm max. NUCLEAR AND MEDICAL APPLICATIONS - Products are not designed or intended for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. [email protected]