RSG HWS1000-60 Single output industrial power supply Datasheet

• Lifetime Warranty
• UL508 Approved
• SEMI F47 Compliant (high line AC)
• Universal Input (85 - 265VAC)
• High Efficiency
• RoHS Compliant Design
Key Market Segments & Applications
Factory Automation:
Test & Measurement:
Automated Service
HWS300-1500 Series
Single Output Industrial
Power Supplies
HWS300-1500 Features and Benefits
Features
Benefits
• Lifetime Warranty
• High Efficiency
• Wide Range AC Input
• Lower Cost of Ownership
• Easier System Cooling
• Supports Global Use
Specifications
MODEL
ITEMS
Input Voltage range (47-63Hz)
Input Current (Typ)
(1)
A
Inrush Current
(1)
Power Factor
Temperature Coefficient
Overcurrent Protection
Overvoltage Protection
Hold Up Time (Typ)
Leakage Curr. (at 240VAC, 60Hz)
Remote Sense
Indicator
Remote on/off
Parallel operation
DC Good
Remote Adjust (PV)
Operating Temperature
Storage Temperature
Humidity (non condensing)
Cooling
Withstand Voltage
(4)
Isolation Resistance
Vibration (non operating)
Shock
Safety Agency Approvals (5)
Line Dip
Conducted & Radiated EMI
Recommended EMI Filter
Immunity
Weight (Typ)
Size
Warranty
A
V
ms
mA
°C
°C
g
mm
HWS300
HWS600
HWS1000
HWS1500
85 - 265VAC or 120 - 330VDC
85 - 265VAC
5V: 7.5/3.6;
3.3V: 9.6/5.0;
3.3V: 15/8
12-48V: 8.1/3.9
5-60V: 13.5/7.0
5-60V: 19/10
20 / 40
Meets EN61000-3-2
<0.02%/°C
>105% (>101% of peak current for peak current capable models)
See table on page 2 (Recycle AC or remote on/off to reset)
20 (HWS1500-7 - 16ms)
<0.75mA
<1.2mA
<1.5mA
Yes
Green LED = ON
Yes (Isolated from output)
Single wire connection (up to 5 units)
Yes
External voltage adjusts output, see options table
-10 to +70, derate linearly to 50% load from 50 to 70 (2, 3)
-30 to +85
Operating: 10 - 90%RH, Non operating 10 - 95%RH
Internal fan
Input to Ground 2.5kVAC, Input to Output 3kVAC, Output to Ground 500VAC for 1 min.
>100M at 25C & 70%RH, Output to Ground 500VDC
10 - 55Hz (1 minute sweep), 19.6m/s2 constant X, Y, Z 1 hour
< 196.1 m/s2
UL60950-1, CSA60950-1, EN60950-1, EN50178, UL508, CE Mark
Complies with SEMI F47 (200VAC line only)
EN55011 / EN55022, FCC VCCI (HWS300, 600 & 1000: Class B, HWS1500: Class A)
MC1206
MC1210
MC1220
MC1230
IEC61000-4-2, -3, -4, -6 (Level 3), -5, -8 (Level 4), -11
1,000
1,600
3,200
3,800
61 x 82 x 165
100 x 82 x 165
240 x 126.5 x 82
280 x 126.5 x 82
Lifetime Warranty (See Lambda’s terms & conditions)
5V: 3.8/1.9;
12-48V: 4.2/2.1
HWS300-1500 Series
1
Model Selector
Model
HWS300-3
HWS600-3
HWS1000-3
HWS1500-3
HWS300-5
HWS600-5
HWS1000-5
HWS1500-5
HWS1000-6
HWS1500-6
HWS1000-7
HWS1500-7
HWS300-12
HWS600-12
HWS1000-12
HWS1500-12
HWS300-15
HWS600-15
HWS1000-15
HWS1500-15
HWS300-24
HWS600-24
HWS1000-24
HWS1500-24
HWS1000-36
HWS1500-36
HWS300-48
HWS600-48
HWS1000-48
HWS1500-48
HWS1000-60
HWS1500-60
Voltage
V
Adjust
Range
V(3)
Max
Curr.
A
Peak
Curr.
A(2)
Max.
Pwr.
W
3.3V
3.3V
3.3V
3.3V
5V
5V
5V
5V
6V
6V
7.5V
7.5V
12V
12V
12V
12V
15V
15V
15V
15V
24V
24V
24V
24V
36V
36V
48V
48V
48V
48V
60V
60V
2.64 - 3.96
2.64 - 3.96
2.64 - 3.96
2.64 - 3.96
4-6
4-6
4-6
4-6
4.8 - 7.2
4.8 - 7.2
6 - 9V
6 - 9V
9.6 - 14.4
9.6 - 14.4
9.6 - 14.4
9.6 - 14.4
12 - 18
12 - 18
12 - 18
12 - 18
19.2 - 28.8
19.2 - 28.8
19.2 - 28.8
19.2 - 28.8
28.8 - 43.2
28.8 - 43.2
38.4 - 52.8
38.4 - 52.8
38.4 - 52.8
38.4 - 52.8
48 - 66
48 - 66
60
120
200
300
60
120
200
300
167
250
134
200
27
53
88
125
22
43
70
100
14
27
46
65/70 (1)
30.7
42/46.5 (1)
7
13
23
32
18.4
28
-
198
396
660
990
300
600
1000
1500
1002
1500
1005
1500
324
636
1056
1500
330
645
1050
1500
336
648
1104
1560
1104
1512
336
624
1104
1536
1104
1536
-
300
160
240
100
80
16.5
31
58.5
105
39
70
29
23.4
42
Peak
Power
W
1800
1200
1800
1200
1200
396
744
1404
2520
1404
2520
1404
1404
2520
Load
Reg
mV
Line
Reg
mV
Ripple
Noise
mV
Overvoltage
V
Eff.
typ
% (1)
30
30
40
60
30
30
40
60
60
60
60
60
72
72
100
72
90
90
120
90
144
144
150
144
150
150
288
288
300
288
360
360
20
20
20
36
20
20
20
36
36
40
36
40
48
48
48
48
60
60
60
60
96
96
96
96
144
144
192
192
192
192
240
240
120
120
120
150
120
120
120
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
200
200
200
350
350
200
200
400
400
4.13 - 4.95
4.13 - 4.95
4.13 - 4.62
4.12 - 4.62
6.25 -7.25
6.25 -7.25
6.25 - 7
4.0 - 6.0
7.5 - 8.4
4.8 - 7.2
9.38 - 10.5
6.0 - 9.0
15 - 17.4
15 - 17.4
15 - 17.4
15 - 17.4
18.8 - 21.8
18.8 - 21.8
18.8 - 21.8
18.7 - 21.8
30 - 34.8
30 - 34.8
30 - 34.8
30 - 34.8
45 - 49.7
45 - 49.7
55.2 - 64.8
55.2 - 64.8
38.4 - 52.8
55.2 - 64.8
69 - 75
48 - 66
74/77
75/78
71/73
72/75
79/82
80/83
76/78
77/81
79/81
79/82
80/82
81/83
80/83
80/83
82/85
82/85
80/83
81/84
83/85
83/87
82/85
82/85
85/87
84/88
85/88
84/88
82/85
83/86
86/88
86/90
85/88
86/90
Notes
(1) 100/200VAC
(2) 200-265VAC Input, 10s maximum on time with 35% duty cycle
(3) Use program input (PV) to adjust from 20-120% of nominal (20-110% for 48V models)
Specification Notes (See Page 1):
Options
Suffix
Blank
/A
/PV
/HD
/ME
2
Description
HWS300-1500 the cover is fitted as standard
Not Applicable
HWS300-1500 the cover is fitted as standard
HWS300, 600 (Standard on HWS1000 & 1500 all output voltages):
1-6V program voltage input to adjust output 20-120%
of nominal (20-110% for 48V) (12V-48V models only for 300 & 600W):
See HWS30-1500/HD Datasheet for details. -40 to
+71(74)°C operation, conformally coated PCBs
See HWS30-1500/ME Datasheet for details.
UL60601-1, EN60601-1 medical approvals
HWS300-1500 Series
(1)
100/200VAC
(2)
HWS start up -20°C. (-40°C see options table)
(3)
HWS1000/1500 with 85VAC input:
See installation manual
HWS1000: -10 to +71°C.
HWS1000-5 derate linearly above 40°C
(4)
2kVAC HWS1000/1500 Input to ground
(5)
UL60601-1, EN60601-1, see options.
UL508; HWS300/600 5V, 12V, 24V & 48V models
Outline Drawing HWS300 -1500 Series
HWS300
Notes
A: Model name, nominal output voltage and
maximum output current are shown in the name
plate in accordance with the specifications.
B: M4 tapped holes (8) for customer chassis
mounting. (Screw penetration depth 6mm
maximum.)
HWS600
Notes
A: Model name, nominal output voltage and
maximum output current are shown in the name
plate in accordance with the specifications.
B: M4 tapped holes (8) for customer chassis
mounting. (Screw penetration depth 6mm
maximum.)
HWS1000 Notes
A: Model name, nominal output voltage and maximum output current are shown in
the name plate in accordance with the specifications.
B: Country of manufacture is shown here.
C: M4 tapped holes (16) for customer chassis mounting. (Screws must not
protrude into power supply by more than 6mm.)
D: I/O Signal Connector.
Connector:
Matching Housing:
Matching Contact:
Hand Crimping Tool:
S12B-PHDSS(LF)(SN)
PHDR-12VS
SPHD-002T-P0.5(AWG28~24)
SPHD-001T-P0.5(AWG26~22)
BPHD-001T-P0.5(AWG26~22)
YRS-620(SPHD-002T-P0.5)
YC-610R(SPHD-001T-P0.5)
YC-610R(BPHD-001T-P0.5)
(JST)
(JST)
(JST) or
(JST) or
(JST)
(JST)
(JST)
(JST)
E: Recommended torque for the terminal piece
Input terminal (M4 screw):
Output terminal (M8 bolt & nut):
Output terminal (M4 screw):
1.27N•m
10.8N•m
1.27N•m
HWS1500 Notes
A: Model name, option, input voltage range, nominal output voltage, maximum
output current are shown in the name plate in accordance with the
specifications.
B: Country of manufacture is shown here.
C: M4 tapped holes (16) for customer chassis mounting. (Screws must not
protrude into power supply by more than 6mm.) Recommended M4 screws
torque: 1.27N•m
D: I/O Signal Connector.
Connector:
Matching Housing:
Matching Contact:
Hand Crimping Tool:
S12B-PHDSS(LF)(SN)
PHDR-12VS
SPHD-002T-P0.5(AWG28~24)
SPHD-001T-P0.5(AWG26~22)
BPHD-001T-P0.5(AWG26~22)
YRS-620(SPHD-002T-P0.5)
YC-610R(SPHD-001T-P0.5)
YC-610R(BPHD-001T-P0.5)
(JST)
(JST)
(JST) or
(JST) or
(JST)
(JST)
(JST)
(JST)
E: Recommended torque for the terminal piece
Input terminal (M4 screw):
Output terminal (M8 bolt & nut):
Output terminal (M4 screw):
HWS300-1500 Series
1.27N•m
10.8N•m
1.27N•m
3
LOCAL DISTRIBUTION
RSG
RSG Electronic Components GmbH Sprendlinger Landstr. 115 D-63069 Offenbach/Germany
Tel. +49 69 984047-0 Fax +49 69 984047-77 [email protected] www.rsg-electronic.de
■
■
ELECTRONIC COMPONENTS
■
Änderungen vorbehalten / subject to change without notice
4
HWS300-1500 Jan09 v1
HWS300-1500 Series
■
■
■