Mean Well CEN-60 60w single output led power supply Datasheet

CEN-60
60W Single Output LED Power Supply
series
½ Features :
Universal AC input / Full range (up to 295VAC)
Protections: Short circuit / Over current / Over voltage / Over temperature
Output voltage and constant current level adjustable
Built-in active PFC function
IP66 design for indoor or outdoor installations
Cooling by free air convection
100% full load burn-in test
High reliability
Suitable for LED lighting and moving sign applications
Compliance to worldwide safety regulations for lighting
Suitable for dry / damp / wet locations
3 years warranty
110
F
M
M
SELV
SPECIFICATION
MODEL
DC VOLTAGE
CEN-60-12
CEN-60-15
CEN-60-20
CEN-60-24
CEN-60-30
CEN-60-36
CEN-60-42
CEN-60-48
CEN-60-54
12V
15V
20V
24V
30V
36V
42V
48V
54V
40.5 ~ 54V
11.25 ~ 15V
15 ~ 20V
18 ~ 24V
22.5 ~ 30V
27 ~ 36V
31.5 ~ 42V
36 ~ 48V
RATED CURRENT
5A
4A
3A
2.5A
2A
1.7A
1.45A
1.3A
1.15A
CURRENT RANGE
0 ~ 5A
0 ~ 4A
0 ~ 3A
0 ~ 2.5A
0 ~ 2A
0 ~ 1.7A
0 ~ 1.45A
0 ~ 1.3A
0 ~ 1.15A
RATED POWER
60W
60W
60W
60W
60W
61.2W
60.9W
62.4W
62.1W
2.4Vp-p
1.8Vp-p
2.4Vp-p
3Vp-p
3.6Vp-p
4Vp-p
4.6Vp-p
5Vp-p
VOLTAGE ADJ. RANGE (SVR1) 10.8 ~ 13.5V 13.5 ~ 17V
17 ~ 22V
22 ~ 27V
27 ~ 33V
33 ~ 40V
37 ~ 46V
43 ~ 53V
49 ~ 58V
CURRENT ADJ. RANGE(SVR2) 3.75 ~ 5A
2.3 ~ 3A
1.9 ~ 2.5A
1.5 ~ 2A
1.3 ~ 1.7A
1.1 ~ 1.45A
1 ~ 1.3A
0.9 ~ 1.15A
CONSTANT CURRENT OPERATION VOLTAGE Note.5 9 ~ 12V
RIPPLE & NOISE (max.) Note.2 2Vp-p
OUTPUT
VOLTAGE TOLERANCE Note.3
10%
LINE REGULATION
3.0%
1400ms / 230VAC 2800ms / 115VAC at full load
SETUP TIME
VOLTAGE RANGE
Note.4 90 ~ 295VAC
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.97/115VAC, PF>0.95/230VAC, PF>0.9/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
EFFICIENCY (Typ.)
86%
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
0.8A/115VAC
45A/230VAC
OVER CURRENT
SHORT CIRCUIT
OVER VOLTAGE
OVER TEMPERATURE
EMC
NOTE
88%
89%
90%
90%
90%
54 ~ 60V
59 ~ 65V
<0.75mA / 240VAC
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Hiccup mode, recovers automatically after fault condition is removed
14.5 ~ 17V 17.5 ~ 21V 22.8 ~ 26V 28 ~ 34V
34 ~ 38V
41 ~ 46V
47 ~ 52V
Protection type : Shut down o/p voltage, re-power on to recover
85
10
(RTH1)
Protection type : Shut down o/p voltage, re-power on to recover
WORKING HUMIDITY
(Refer to "Derating Curve")
-40 ~ +80 , 10 ~ 95% RH
0.03%/ (0 ~ 50 )
VIBRATION
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY STANDARDS
UL879, UL8750, TUV EN61347-1, EN61347-2-13, J61347-1, J61347-2-13, IP66 approved
WITHSTAND VOLTAGE
I/P-O/P:3.75KVAC I/P-FG:1.88KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55015, EN61000-3-2 Class C ( 75% load) ; EN61000-3-3
DIMENSION
PACKING
91%
95 ~ 110%
20 ~ 95% RH non-condensing
ISOLATION RESISTANCE
EMC EMISSION
91%
0.4A/230VAC
-30 ~ +70
EMC IMMUNITY
MTBF
OTHERS
87%
WORKING TEMP.
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
SAFETY &
127 ~ 417VDC
FREQUENCY RANGE
LEAKAGE CURRENT
PROTECTION
3 ~ 4A
5.0%
LOAD REGULATION
INPUT
IP66
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61547, light industry level (surge 4KV), criteria A
523.4Khrs min. MIL-HDBK-217F (25
183*62.5*40.5mm (L*W*H)
0.56Kg;24pcs/14.4Kg/1.11CUFT
)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. Constant current operation region is within 75% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please
reconfirm special electrical requirements for some specific system design.
6. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
7. Direct connecting to LEDs is suggested, but is not suitable for using additional drivers.
File Name:CEN-60-SPEC 2011-07-28
CEN-60
60W Single Output LED Power Supply
Mechanical Specification
Case No.993B
series
Unit:mm
183
10.5
162
7.6
300 20
T case
300 20
Vo
Io
ADJ. ADJ.
81
31.25
30.6
45
62.5
AC/L(Brown)
AC/N(Blue)
FG (Green/Yellow)
SJTW 18AWG 3C
+V(Red)
-V(Black)
SVT 18AWG 2C
4.6 4PL
40.5
T case: Max. Case Temperature.
Block Diagram
fosc : 50KHz(115VAC)
75KHz(230VAC)
EMI FILTER
&
RECTIFIERS
I/P
RECTIFIERS
&
FILTER
POWER
SWITCHING
FG
+V
-V
DETECTION
CIRCUIT
O.L.P.
PWM & PFC
CONTROL
O.C.P.
O.V.P.
Derating Curve
Static Characteristics
100
100
90
80
80
70
LOAD (%)
LOAD (%)
60
40
20
-30
-25
-5
0
15
30
50
AMBIENT TEMPERATURE ( )
60
70
(HORIZONTAL)
60
50
40
90
100
125
135
145
155 165
175
180
200
230
295
INPUT VOLTAGE (V) 60Hz
File Name:CEN-60-SPEC 2011-07-28
CEN-60
60W Single Output LED Power Supply
series
Power Factor Characteristic
Constant Current Mode
1.00
0.96
0.92
PF
0.88
0.84
277Vac
0.80
230Vac
0.76
115Vac
0.72
0.68
0.64
50%
60%
70%
80%
90%
100%
(60W)
LOAD
EFFICIENCY vs LOAD (48V Model)
EFFICIENCY (%)
CEN-60 series possess superior working efficiency that up to 91% can be reached in field applications.
94
90
86
82
78
74
70
66
62
58
54
50
277Vac
230Vac
115Vac
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
LOAD
DRIVING METHODS OF LED MODULE
This LED power supply is suggested to work in constant current mode area (CC) to drive the LEDs.
100
Vo(%)
Constant
Current area
75
(max.)
Hiccup
Protection
50
100
Io (%)
Typical LED power supply I-V curve
File Name:CEN-60-SPEC 2011-07-28
Similar pages