Minmax MJWI10 Dc/dc converter 10w, high power density Datasheet

®
MJWI10 SERIES
DC/DC CONVERTER 10W, High Power Density
FEATURES
►Package Size 1.0”x1.0”x0.4”
►Ultra-wide 4:1 Input Range
►High Efficiency up to 87%
►Operating Temp. Range -40°C to +80°C
►I/O-isolation Voltage 1500VDC
►Remote On/Off Control
►Input Filter complies to EN55022,Class A & FCC,Level A
►Shielded Metal Case with Isolated Baseplate
►CSA/UL/IEC/EN 60950-1 Safety Approval
►3 Years Product Warranty
PRODUCT OVERVIEW
The MINMAX MJWI10 series are cost optimized dc-dc converter modules offering 10W output power in a 1”x1”x0.4” shielded metal package with industry
standard pinout. All models provide ultra-wide 4:1 input voltage range and tight output voltage regulation.
State-of-the-art circuit topology provides a high efficiency up to 87% which allows an operating temperature range of -40°C to +80°C. Further features
include remote On/Off, overload protection and conducted EMI compliance to EN55022, class A.
Typical applications for these converters are battery operated equipment, instrumentation, distributed power architectures in communication and industrial
electronics and other space critical applications.
Model Selection Guide
Model
Input
Output
Number
Voltage
Voltage
Output Current
VDC
24
(9 ~ 36)
48
(18 ~ 75)
Max. capacitive
Load
(Range)
MJWI10-24S033
MJWI10-24S05
MJWI10-24S051
MJWI10-24S12
MJWI10-24S15
MJWI10-24S24
MJWI10-24D05
MJWI10-24D12
MJWI10-24D15
MJWI10-48S033
MJWI10-48S05
MJWI10-48S051
MJWI10-48S12
MJWI10-48S15
MJWI10-48S24
MJWI10-48D05
MJWI10-48D12
MJWI10-48D15
Input Current
VDC
3.3
5
5.1
12
15
24
±5
±12
±15
3.3
5
5.1
12
15
24
±5
±12
±15
Max.
@Max. Load
@No Load
mA
2200
2000
2000
830
660
410
±1000
±410
±330
2200
2000
2000
830
660
410
±1000
±410
±330
mA(typ.)
352
496
506
483
474
477
496
477
474
180
248
253
241
237
238
248
238
237
mA(typ.)
30
20
Efficiency
(typ.)
@Max. Load
μF
560
560
560
150
150
68
220#
100#
100#
560
560
560
150
150
68
220#
100#
100#
# For each output
%
86
84
84
86
87
86
84
86
87
85
84
84
86
87
86
84
86
87
Input Specifications
Parameter
Model
24V Input Models
48V Input Models
24V Input Models
48V Input Models
24V Input Models
48V Input Models
Input Surge Voltage (1 sec. max.)
Start-Up Threshold Voltage
Under Voltage Shutdown
Reverse Polarity Input Current
Short Circuit Input Power
All Models
Internal Power Dissipation
Conducted EMI
Typ.
--------------2500
---
Max.
50
100
9
18
8.5
17
1.5
--5000
Unit
VDC
A
mW
mW
Compliance to EN 55022,class A and FCC part 15,class A
E-mail:[email protected]
2012/07/16 REV:15
Min.
-0.7
-0.7
---------------
Tel:886-6-2923150
Page 1 of 5
®
MJWI10 SERIES
DC/DC CONVERTER 10W, High Power Density
Output Specifications
Conditions
Min.
Typ.
Max.
Unit
Output Voltage Setting Accuracy
Parameter
At 50% Load and Nominal Vin
---
---
±2.0
%Vnom.
Output Voltage Balance
Dual Output, Balanced Loads
---
±1.0
±2.0
%
Line Regulation
Vin=Min. to Max.
---
±0.3
±1.0
%
Load Regulation
Io=0% to 100%
---
±0.5
---
%
Min.Load
No minimum Load Requirement
Ripple & Noise (20MHz)
---
60
100
mV p-p
Transient Recovery Time
---
300
600
μsec
---
±3
±6
%
---
±0.01
±0.02
%/℃
110
150
---
%
25% Load Step Change
Transient Response Deviation
Temperature Coefficient
Over Load Protection
Foldback
Short Circuit Protection
Continuous
General Specifications
Parameter
Conditions
Min.
Typ.
Max.
Unit
60 Seconds
1500
---
---
VDC
I/O Isolation Resistance
500 VDC
1000
---
---
MΩ
I/O Isolation Capacitance
100KHz, 1V
---
---
1500
pF
---
450
---
KHz
I/O Isolation Voltage (rated)
Switching Frequency
MTBF(calculated)
Safety Approvals
MIL-HDBK-217F@25℃, Ground Benign
350,000
----UL/cUL 60950-1 recognition(CSA certificate), IEC/EN 60950-1(CB-scheme)
Hours
Input Fuse
24V Input Models
48V Input Models
2000mA Slow-Blow Type
1000mA Slow-Blow Type
Remote On/Off Control
Parameter
Conditions
Converter On
Min.
Typ.
Max.
Unit
2.5V ~ 50V or Open Circuit
Converter Off
0~1.0V or Short Circuit (Pin 2 and Pin 6)
Control Input Current (on)
Vctrl = 5V
Control Input Current (off)
Vctrl = 0V
Control Common
---
---
500
μA
---
---
-500
μA
---
10
mA
Referenced to Negative Input
Standby Input Current
---
Environmental Specifications
Parameter
Conditions
Min.
Natural Convection
Max.
Unit
-40
+80
℃
Case Temperature
---
+100
℃
Storage Temperature Range
-50
+125
℃
Humidity (non condensing)
---
95
% rel. H
260
℃
Operating Ambient Temperature Range (See Power Derating Curve)
Cooling
Free-Air convection
RFI
Six-Sided Shielded, Metal Case
Lead Temperature (1.5mm from case for 10Sec.)
E-mail:[email protected]
2012/07/16 REV:15
Tel:886-6-2923150
Page 2 of 5
---
®
MJWI10 SERIES
DC/DC CONVERTER 10W, High Power Density
Output Power (%)
Output Power (%)
Power Derating Curve
Derating Curve without Heatsink
Derating Curve with Heatsink
Notes
1
Specifications typical at Ta=+25℃, resistive load, nominal input voltage and rated output current unless otherwise noted.
2
Transient recovery time is measured to within 1% error band for a step change in output load of 75% to 100%.
3
Ripple & Noise measurement bandwidth is 0-20 MHz.
4
All DC/DC converters should be externally fused at the front end for protection.
5
Other input and output voltage may be available, please contact factory.
6
To order the converter with heatsink, please add a suffix -HS (e.g. MJWI10-24S05-HS) to order code.
7
That “natural convection” is about 20LFM but is not equal to still air (0 LFM)
8
Specifications are subject to change without notice.
Package Specifications
Mechanical Dimensions
2.54
[0.10]
25.4 [1.00]
10.16
[0.40]
10.16
[0.40]
4
Bottom View
1
2
5.08
[0.20]
6
7.62
[0.30]
1.00
[0.04]
20.3 [0.80]
5
25.4 [1.00]
3
6.0
10.16 0.5
[0.24] [0.40 0.02]
2.54
[0.10]
Case Size
:
25.4x25.4x10.16mm (1.0x1.0x0.4 inches)
Case Material
:
Aluminium Alloy, Black Anodized Coating
Base Material
:
FR4 PCB (flammability to UL 94V-0 rated)
Pin Material
:
Copper Alloy with Gold Plate Over Nickel Subplate
Weight
:
15g
2012/07/16 REV:15
Tel:886-6-2923150
Page 3 of 5
Dual Output
+Vin
2
-Vin
-Vin
3
+Vout
+Vout
4
No Pin
Common
5
-Vout
-Vout
6
Remote On/Off
Remote On/Off
►All
dimensions in mm (inches)
►Tolerance: X.X±0.25
Physical Characteristics
E-mail:[email protected]
Pin Connections
Pin
Single Output
1
+Vin
(X.XX±0.01)
X.XX±0.13 ( X.XXX±0.005)
►Pin
diameter  1.0 ±0.05 (0.04±0.002)
®
MJWI10 SERIES
DC/DC CONVERTER 10W, High Power Density
Heatsink (Option –HS)
Mechanical Dimensions
Heatsink Material: Aluminum
Finish: Anodic treatment (black)
16.3 [0.64]
Weight: 2g
17.46
[0.69] Max.
►The
31.0 [1.22] Max.
Heat-Sink
Thermal Pad
Clamp
Converter
E-mail:[email protected]
2012/07/16 REV:15
Tel:886-6-2923150
Page 4 of 5
advantages of adding a heatsink are:
1.To help heat dissipation and increase the stability
and reliability of DC/DC converters at high
operating temperature atmosphere.
2.To upgrade the operating temperature of DC/DC
converters, please refer to Derating Curve.
®
MJWI10 SERIES
DC/DC CONVERTER 10W, High Power Density
Test Setup
Input Reflected-Ripple Current Test Setup
Input reflected-ripple current is measured with a inductor Lin (4.7μH) and Cin (220μF, ESR < 1.0Ω at 100 KHz) to simulate source impedance. Capacitor Cin, offsets
possible battery impedance. Current ripple is measured at the input terminals of the module, measurement bandwidth is 0-500 KHz.
To Oscilloscope
+
+
Battery
+Vin
Lin
DC / DC
Converter
Current
Probe
Cin
+Out
-Vin
Load
-Out
Peak-to-Peak Output Noise Measurement Test
Use a Cout 0.47μF ceramic capacitor. Scope measurement should be made by using a BNC socket, measurement bandwidth is 0-20 MHz. Position the load
between 50 mm and 75 mm from the DC/DC Converter.
+Vin
+Out
Copper Strip
Single Output
DC / DC
Converter
-Vin
Cout
-Out
Scope
Resistive
Load
Copper Strip
+Vin
+Out
Copper Strip
Dual Output
DC / DC
Converter
Com.
Copper Strip
-Vin
-Out
Scope
Cout
Resistive
Load
Cout
Scope
Copper Strip
Technical Notes
Remote On/Off
Positive logic remote on/off turns the module on during a logic high voltage on the remote on/off pin, and off during a logic low. To turn the power module on and off,
the user must supply a switch to control the voltage between the on/off terminal and the -Vin terminal.
The switch can be an open collector or equivalent. A logic low is 0V to 1V. A logic high is 2.5V to 50V. The maximum sink current at on/off terminal during a logic
low is -500μA. The maximum allowable leakage current of the switch at on/off terminal (2.5 to 50V) is 500μA.
Overcurrent Protection
To provide protection in a fault (output overload) condition, the unit is equipped with internal current limiting circuitry and can endure current limiting for an unlimited
duration. At the point of current-limit inception, the unit shifts from voltage control to current control. The unit operates normally once the output current is brought back
into its specified range.
Input Source Impedance
The power module should be connected to a low ac-impedance input source. Highly inductive source impedances can affect the stability of the power module.
In applications where power is supplied over long lines and output loading is high, it may be necessary to use a capacitor at the input to ensure startup.
Capacitor mounted close to the power module helps ensure stability of the unit, it is recommended to use a good quality low Equivalent Series Resistance (ESR <
1.0Ω at 100 KHz) capacitor of a 6.8μF for the 24V and 48V devices.
+
DC Power
Source
+Vin
+
+Out
DC / DC
Converter
Load
Cin
-
-Vin
-Out
Output Ripple Reduction
A good quality low ESR capacitor placed as close as practicable across the load will give the best ripple and noise performance. To reduce output ripple, it is
recommended to use 4.7μF capacitors at the output.
+
+Vin
DC Power
Source
-
+Out
Single Output
DC / DC
Converter
-Vin
+
Cout
Load
-Out
+Vin
DC Power
Source
-
+Out
Dual Output
DC / DC
Com.
Converter
-Vin
-Out
Cout
Load
Load
Cout
Maximum Capacitive Load
The MJWI10 series has limitation of maximum connected capacitance at the output. The power module may be operated in current limiting mode during start-up,
affecting the ramp-up and the startup time. The maximum capacitance can be found in the data sheet.
Thermal Considerations
Many conditions affect the thermal performance of the power module, such as orientation, airflow over the module and board spacing. To avoid exceeding the
maximum temperature rating of the components inside the power module, the case temperature must be kept below 100℃. The derating curves are determined
from measurements obtained in a test setup.
Position of air velocity
probe and thermocouple
15mm / 0.6in
50mm / 2in
Air Flow
DUT
18, Sin Sin Road, An-Ping Industrial District, Tainan 702, Taiwan
Tel: 886-6-2923150 Fax: 886-6-2923149 E-mail: [email protected]
Minmax Technology Co., Ltd.
2012/07/16 REV:15
Page 5 of 5
Similar pages