Series AMES15-MAZ 15 Watt | AC-DC / DC-DC Converter FEATURES: • • • • • Screw Terminals on Input & Output Operating temperature: -40 to +80°C Over load, Over Voltage, Short Circuit Protection Optional DIN Rail mounting bracket Universal input: 90-264VAC, 47-440Hz • • • • • RoHS compliant Soft start Energy Star compliant CE, cULus, CB approvals 4000VAC I/O Isolation CB Models Single output Model Input Voltage (VAC/Hz) Input voltage (VDC) 90-264/47-440 90-264/47-440 90-264/47-440 90-264/47-440 90-264/47-440 120-370 120-370 120-370 120-370 120-370 Input Voltage (VAC/Hz) Input voltage (VDC) 90-264/47-440 90-264/47-440 90-264/47-440 120-370 120-370 120-370 AMES15-3.3SMAZ AMES15-5SMAZ AMES15-12SMAZ AMES15-15SMAZ AMES15-24SMAZ Max Output wattage (W) 9.9 15 15 15 15 Output Voltage (V) 3.3 5 12 15 24 Output Current max (A) 3 3 1.25 1 0.63 Ripple & Noise (mV) Maximum Capacitive Load (µF) Efficiency (%) 50 50 100 100 100 4700 2200 1000 680 470 74 78 81 81 83 Ripple & Noise* (mV) Maximum Capacitive Load (µF) Efficiency (%) 50 100 100 ±1000 ±470 ±330 78 80 81 Models Dual output Model AMES15-5DMAZ AMES15-12DMAZ AMES15-15DMAZ Max Output wattage (W) 15 15 15 Output Voltage (V) ±5 ±12 ±15 Output Current max (A) ±1.5 ±0.63 ±0.5 *Ripple & Noise measured with 1µF M/C and 47µF E/C (20MHz bandwidth) Input Specifications Parameters Current Inrush current <2ms Leakage current External Fuse (recommend) Input Dissipation Under Voltage Protection Conditions Typical 115VAC 230VAC 115 VAC 230 VAC 115 VAC 264 VAC slow blow type No load Maximum Units 350 180 10 20 0.1 0.2 mA mA A A mA mA A W VAC Maximum Units 2 <0.5 88 Output Specifications Parameters Voltage accuracy Line regulation Load regulation (single output) Cross regulation (dual output) Transient Recovery Time Transient Recovery Deviation Hold-up time www.aimtec.com F 052e R7.M Conditions Typical LL-HL 0-100% st nd 25% load - 1 out, 100% load – 2 out 25% load step min Tel: +1 514 620 2722 1 of 5 ±2 ±0.5 ±0.5 ±5 200 ±2 20 % % % % µs % of Vout ms Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMES15-MAZ 15 Watt | AC-DC / DC-DC Converter Isolation Specifications Parameters Conditions Tested I/O voltage Isolation resistance Typical 3 sec Rated Units 4000 VAC MΩ Maximum Units >1000 General Specifications Parameters Conditions Switching frequency Start up time Over load protection Over voltage protection Short circuit protection Short Circuit restart Operating temperature Storage temperature Max Case temperature Temperature coefficient Cooling Humidity Weight Dimensions (L x W x H) MTBF Typical 132 900 >131 Zener diode clamp Continuous Auto recovery -40 to +80 -50 to +100 Auto recovery, hiccup mode o With derating over 55 C (10CFM) KHz mS % o C C o C o %/ C o 100 ±0.02 Free air convection 95 100 3.62 x 2.56 x 0.94 inches 92.0 x 65.0 x 24.0 mm o > 400 000hrs (MIL-HDBK -217F, t=+25 C) % RH g NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Environment Approval Parameters Shock Vibrations Conditions Wave form: Half sine wave Acceleration amplitude: 5gn Bump duration: 30 ms Number of bumps: 18 (3 in each direction for every axis) Converter operation before and after test, body mounted (on chassis) Test mode: Sweep sine 10-100Hz, speed 0.05Hz/s Displacement: 1mm Acceleration: 3g 3 loops 30min one cycle, 3h total, every axis tested Converter operation before and after test, body mounted (on chassis) Safety & EMC Specifications Parameters Agency approvals Standards www.aimtec.com F 052e R7.M cULus, CE, CB Medical Electrical Equipment Information technology Equipment EMI - Conducted and radiated emission Harmonic Current Emissions Voltage fluctuations and flicker Electrostatic Discharge Immunity RF, Electromagnetic Field Immunity Electrical Fast Transient/Burst Immunity Surge Immunity RF, Conducted Disturbance Immunity Power frequency Magnetic Field Immunity Voltage dips, Short Interruptions Immunity IEC\EN\UL 60601-1, CSA-C22.2 No. 601.1-M90 EN 60950-1:2006+A11:2009 EN55011, class B IEC/EN 61000-3-2, (EN60555-2) IEC/EN 61000-3-3, (EN60555-3) IEC 61000-4-2 IEC 61000-4-3 IEC 61000-4-4 IEC 61000-4-5 IEC 61000-4-6 IEC 61000-4-8 IEC 61000-4-11 Tel: +1 514 620 2722 2 of 5 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMES15-MAZ 15 Watt | AC-DC / DC-DC Converter Derating A A B Free Air Convection Output Power (%) 100 40 º C 80 B 60 40 10 CFM 55 º C Safe Operating Area 20 0 - 40 - 20 0 20 40 60 80 85 100 Ambient Temperature º C Pin Out Specifications Pin Single Dual 1 2 3 4 5 AC Input (N) AC Input (L) -V Output No Connection +V Output AC Input (N) AC Input (L) -V Output Common +V Output www.aimtec.com F 052e R7.M Tel: +1 514 620 2722 3 of 5 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMES15-MAZ 15 Watt | AC-DC / DC-DC Converter 24 Dimensions PCB Mounting Screw PCB Mounting Screw PCB Mylar Film Bracket Mountin g Screw PCB Mylar Film 2.6 mm Max Customer Chassis www.aimtec.com F 052e R7.M Tel: +1 514 620 2722 4 of 5 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMES15-MAZ 15 Watt | AC-DC / DC-DC Converter Optional DIN Rail Bracket NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 052e R7.M Tel: +1 514 620 2722 5 of 5 Toll free: + 1 888 9 AIMTEC (924 6832) North America only