HITRON HEG42-240150-7L Ac/dc external desktop adapter universal input single output 42 watts green power switching power supply Datasheet

H HiTRON
AC/DC EXTERNAL DESKTOP ADAPTER UNIVERSAL INPUT
SINGLE OUTPUT 42 WATTS GREEN POWER
SWITCHING POWER SUPPLIES HEG42 SERIES
FEATURES:
ACCOMMODATE UNIVERSAL AC INPUT
DESKTOP IEC320-3P /3PL/2P AC
RECEPTACLE
GREEN POWER
MEET UNIVERSAL SAFETY STANDARDS
EMI MEET EN55022 / FCC CLASS B
CE MARKING COMPLIANCE
SPECIFICATION
INPUT SPECIFICATION
OUTPUT SPECIFICATION
Input Voltage: 90-264Vac typical.
Input Connector: IEC320-3P DT7 or DT7L or 2P DT8
AC inlet receptacle.
Input Frequency: 47-63Hz.
Inrush Current: 8.0Arms @230Vac typical.
Input Current: 0.63A @115Vac & 0.35A @230Vac typical.
Dielectric Withstand: Meet IEC60950-1.
EMI: Meet EN55022 / FCC Class B.
Hold-up Time: 15.6mS @115Vac typical.
89.6mS @230Vac typical.
Green Power: 0.157W@131Vac & 0.256W @ 264Vac
Earth Leakage: Less than 0.17mA for class II or
Less than 0.4mA for class I
Output Voltage: See Ratings Chart.
Output Current: See Ratings Chart.
Output Wattage: 42 Watt typical.
Output Connector & Cord: Optional.
Line Regulation: 0.5% typical.
Load Regulation: ±3.0% typical.
Tolerance: ±5%.
Noise & Ripple: 1.0% typical peak to peak.
OVP: Built-in, Latch.
Overload Protection:
Fully protected against output overload or short circuit.
Typical set at 105-140% at 115Vac.
Consult the factory for special OLP setting.
GENERAL SPECIFICATION
Efficiency: 87-88% typical.
Switching Frequency: Approximate 59-63KHz.
Circuit Topology: Fixed Frequency flyback circuit.
Transient Response: Output voltage returns in less than
1mS following a 25% load change.
Safety Standard: Meet UL60950-1/EN60950-1 Class I or II.
Power Density: Typ. 3.3Watts / Cubic inch.
Operating Temperature: 0 to +25/35/40°C
without derating. (various with output voltage)
Storage Temperature: -20 to +85°C.
Temperature Coefficient: 0.04% /°C.
Cooling: Free air convection.
Construction: Impact resistant thermo-plastic case.
Desktop Format.
NOTE: (1) All measurements are at nominal input, full load, and +25°C unless otherwise specified.
(2) Load regulation is measured at 115Vac or 230Vac in percentage indicate the change in output voltage as the load varied from half load to full load(±%)
(3) The exact obtainable load regulation depends upon the output cord selected and load current. Upper data are for 6 ft. (2 m) cord AWG#18 wires.
(4) Due to requests in market and advances in technology, specifications subject to change without notice
For the details of safety approval, please consult the factory.
-29-
OUTPUT VOLTAGE/CURRENT RATINGS CHART
SINGLE OUTPUT
MODEL NO.
AC PLUG
O/P VOLTAGE
O/P CURRENT
HEG42-120400-7
DT7
12.0Vdc
4.00A
HEG42-120400-8
DT8
12.0Vdc
4.00A
HEG42-150280-7
DT7
15.0Vdc
2.80A
HEG42-150280-8
DT8
15.0Vdc
2.80A
HEG42-190220-7
DT7
19.0Vdc
2.20A
HEG42-190220-8
DT8
19.0Vdc
2.20A
HEG42-240100-7L
DT7L
24.0Vdc
1.00A
HEG42-240150-7L
DT7L
24.0Vdc
1.50A
HEG42-240200-7L
DT7L
24.0Vdc
2.00A
HEG42-240200-7
DT7
24.0Vdc
2.00A
HEG42-240200-8
DT8
24.0Vdc
2.00A
MECHANICAL DIMENSIONS: MM [INCHES]
-30-
WEIGHT: 320g(11.30Oz)
Similar pages