medical FEATURES: AHP2501 25W Me d i c a l P o wer A dapt ers w i t h I nt erch a n g e a b le In p u t Plu g s series Input Range of 80 to 275VAC, 47 to 63 Hz. RoHSWide 2 2011/65/EU Interchangeable Input Plugs medical IEC60601-1 3rd Edition, 2 MOPP APPLICATIONS: Class II HPU63B series 63 TheLevel HPU63B Efficiency V series of AC/DC switching mode power supplies APPROVALS: 2.95” x 1.71” x IP22 Model Number AHP2501-01 AHP2501-02 AHP2501-03 AHP2501-04 AHP2501-05 AHP2501-06 AHP2501-07 AHP2501-08 AHP2501-09 AHP2501-10 AHP2501-11 AHP2501-12 Symbol Output Vins Watts Vin Fi Po 10.5 Iil 16.5 Iih 20Irl 22Irh 25 25△Voi 25OLP 25ttr thu 25 ts 25 Tc 25HV 25EMI 1.58” CB IP22 Characteristic Output Voltage 3.3VDC 5VDC 6VDC 9VDC 12VDC Efficiency 15VDC 18VDC 24VDC 30VDC 36VDC 48VDC 55VDC Output Amps Efficiency 3.18 3.3 3.3 2.44 2.08 1.66 1.38 1.04 0.83 0.69 0.52 0.45 65% 80% 82% 83% 84% 85% 85% 86% 86% 86% 86% 86% Condition Input NL Power Consumption 0.2 Watts 0.3 Watts 0.3 Watts 0.3 Watts 0.3 Watts 0.3 Watts 0.3 Watts 0.3 Watts 0.3 Watts 0.3 Watts 0.3 Watts 0.3 Watts Environmental: Symbol Characteristic To non-condensing Ho Hs Vsg ESDa ESDc MTBF ELEV VBR Total Regulation Ripple & Noise ±5% 66mV p-p ±5% 50mV p-p ±5% 70mV p-p APPROVALS: ±5% 90mV p-p ±5% 100mV p-p ±5% 100mV p-p ±5% 100mV p-p Electrical ±3% Characteristics: 100mV p-p Symbol Characteristic ±3% 100mV p-p Safety Approval Input Voltage Range Vins ±3% 100mV p-p Input Operate Voltage Range Vin ±3% 100mV p-p Input Frequency Fi ±3% 100mV p-p Output Power Range Po CB EN 60601-1 IEC 60601-1 Vibration WWW.ASTRODYNETDI.COM Min. 100 RoHS2 2011/65/EU * Wide O * IEC-32 * Single * Over V * Medic * Input t * Energy * Class II * 3 year Typ. Max. Unit APPLIC 240 VAC 80 275 47 63 25 0.7 0.4 50 100 PS E 0.5 1 110 150 4 12 * Home VAC * Patien Hz * Blood W * Portab *AECG m A GENER A * Short C *ACoolin * Flamm *%Protec *%Safety (TUV/T-m ms ms s Safety Approval &3Specification i ±0.04 %/°C Detail to see Fig.1 (Derate linearly 4000 VAC Sine wave SeeBRating Chart Iil Low Line Input Current Full Load, Vin=100VAC Iih High Line Input Current Full Load, Vin=240VAC Class Irl Low Line Input Inrush Current Condition Full Load,Typ. 25°C, Max. Cool start, UnitVin=1 Min. Irh High Line Input Inrush Current Full-10 Load, 25°C, Cool °C Vin=2 70 start, Full-40 Load, Vin=230VAC, Detail to 85 °C △Voi Line Regulation Full0Load, Vin=100~120VAC 95% RH or 20 OVP Over Voltage Protection OLP Over Load Protection 0 95% RH Recovers automatically after kV fau 2 Full8Load, Vin=110VAC kV Full6Load, Vin=100VAC kV Efficiency Ts FEATU provide 63 Watts of continuous output power . All supplies are UL94V-1 min compliant. All models meet FCC Part-18 class B and CISPR-11 EN55011 class B emission Limits and are designed to comply with ANSI/AAMI ES 60601-1: 2005(UL/cUL 3rd Edition), EN 60601-1:2006 (TUV/T-mark 3rd Edition) and new CE requirements. Cooling All units are 100% burned in and tested. ttr Time of Transient Response thu Hold-Up Time ts Start-up time Full Load, Vin=100~240VAC 100k h Tc Temperature Coefficient HV Dielectric Withstanding Voltage (P-S) All Condition 3000 m 5 G curre Primary to Secondary, limit EMI EMC Emission Compliance to EN55011 (CISPR1 ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 Environmental: Symbol Characteristic 25W Me d i c a l P o wer A dapt ers w i t h I nt erch a n g e a b le In p u t Plu g s INPUT SPECIFICATIONS Input Voltage Range Frequency Range (Sine Wave) Input Current Inrush Current, typ (Cold Start) Protection Class Input NL Power Consumption 80-275 VAC (100-240V Nominal) See Input Derate curve, Fig. 1 47-63 Hz Low Line (100VAC) 0.7A max. High Line (240VAC) 0.4A max. Low Line (100VAC) 50A max. High Line (240VAC) 100A max. Double Insulated, Class II See Selection Chart See Selection Chart 0 to FL Rating See Selection Chart ± 1%, max. 110-150%, auto recover Auto Recover 110Vin, FL 4mS ±0.04%/°C, typ See Selection Chart 100Vin, FL 3S max. / 12mS min. GENERAL SPECIFICATIONS Input-Out Isolation Efficiency (FL, Nom. Input)) Safety 4000 VAC See Selection Chart ANSI/AAMI ES 60601-1:2005 (UL/cUL 3rd Edition) Oper. Temperature Storage Temperature Operating/Storage Humidity Cooling EMC Surge Voltage ESD Air ESD Contact MTBF MIL-HDBK-217F, 25°C Operating Altitude Vibration Flammability Rating -10 to +40°C (FL) * 50% Load @ 70°C See Output Derate Curve, Fig. 2 -40 to +85°C, 10~95% RH * 0% to 95% RH * Free Air Convection EN55011 (CISPR11), EN61000-3-2,-3 Class B 2kV, All Conditions 8kV, IEC61000-4-2 6kV, IEC61000-4-2 100K h 3000m 5G, 10~500Hz, 10 min./1 cycle, 60 min. each along X, Y, Z axes UL94V-1 NOTES 1. Line Regulation defined as changing the input voltage ±10% from nominal line at rated load. 2. Total Regulation is defined by as changing the load ±40% from 60% rated load. 3. Ripple & Noise is measured by using a 20MHz bandwidth limited oscilloscope and terminating the output with a 0.47uF capacitor at rated load and nominal line. * These are stress ratings. Exposure of the devices to any of these conditions may adversely affect long term reliability. Proper operation under conditions other than the standard operating conditions is neither warranteed nor implied. PHYSICAL SPECIFICATIONS Size Construction Weight series ENVIRONMENTAL SPECIFICATIONS OUTPUT SPECIFICATIONS Voltage and Current Output Power Range Total Regulation (Note 2) Line Regulation, FL (Note 1) Over Load Protection* Short Circuit Protection Transient Response Temperature Coefficient Ripple/Noise (Note 3) Start Up / Hold Up Time AHP2501 2.95” x 1.71” x 1.58” (75 x 43.4 x 40.1mm) Wallmount Style 7.05oz (200g) All specifications are typical at nominal input, full load, and 25°C unless otherwise noted WWW.ASTRODYNETDI.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 50 rated load and nominal line. 6. Hold up time is measured from the end of the last charging pulse to the time which the main output drops down to low limit of main output at rated load and nominal line. 7. Efficiency is measured at rated load, and nominal line. 8. The specifics for testing the energy efficiency of this Series are outlined in a separate document titled "Test Method for Calculating the Energy Efficiency of Single-Voltage Interchangeable AC-DC and AC-AC Power Supplies (August 11, 2004)," which is available on the ENERGY STAR Website. 80 100 120 140 160 180 200 220 INPUT VOLTAGE (VAC) (FIG.1) INPUT VOLTAGE DERATING CURVE 240 260 280 110 100 90 80 70 60 AHP2501 50 40 25W Me d i c a l P o wer A dapt ers w i t h I nt erch a n g e a b le In p u t Plu g s 30 20 series 10 MECHANICAL DIMENSIONS 0 -10 MECHANICAL DIMENSIONS: ( UNIT: mm ) 0 10 20 30 40 50 TEMPERATURE (°C) (FIG.2) TEMPERATURE DERATING CURVE 60 70 80 OUTPUT CABLE RECOMMEND : 1. Selected output connectors and wire, please refer to Appendix. 2. HPU25-101~104 are required to use AWG#18 2C/4FT output cable. 3. HPU25-105~109 are required to use AWG#20 2C/4FT output cable. 4. HPU25-110~112 required to use AWG#22 2C/4FT output cable. DC OUTPUTare CONNECTIONS 5. The regulation and efficiency will be changed by modified output cable. Coaxial Plug: -Vout +Vout PACKING : 5.5mm outer200g diameter 1. Net weight: approx. 2.1mm inner diameter, femaleavailable contact sales for details. 2. Optional output connectors 11mm length, center “+” Dimensions are in mm [inches] Rating Chart: Ripple & Noise Total Regulation Typ. Efficiency No Load Consumption Hold-Up Time MODEL NO. dical (W) (mVp-p) (%) (%) (W) (ms) HPU25-101 (VDC) 3.0 HPU25-103 6.0 eak load when the power supply HPU25-104 starts up. than rated load is not allowed. HPU25-105 condition, each output is checked to be 8.0 11.0 HPU25-106 13.0 changing ±10% of input voltageHPU25-107 from 16.0 HPU25-108 21.0 HPU25-109 27.0 by using 20MHz bandwidth limited HPU25-110 d each output with a 0.47uF capacitor at HPU25-111 . om the end of the last charging pulse to the HPU25-112 t drops down to low limit of main output at . ed load, and nominal line. energy efficiency of this Series are outlined ed "Test Method for Calculating the Energy Interchangeable AC-DC and AC-AC Power " which is available on the ENERGY STAR 33.0 40.0 y changing ±40% of measured output load (VDC) (A) (A) 5.0 2.10 3.50 66 ±5 65 0.2 12 OLP 50 ±5 80 0.3 12 OLP 10.5 25W5.0 Interchangeable Medical Grade Supply 6.0 2.75 3.30 Power 16.5 LOAD (%) DERATE CURVES 25 series HPU25-102 The change if output maxRegulation and minEfficiency willmax cable is modified. min 8.0 2.50 3.30 20 70 ±5 82 0.3 12 OLP 11.0 2.00 2.75 22 90 ±5 83 0.3 12 OLP 13.0 1.92 2.27 25 100 ±5 84 0.3 12 OLP 90 16.0 1.56 1.92 25 100 ±5 85 0.3 12 OLP 80 21.0 1.19 1.56 25 100 ±5 85 0.3 12 OLP 27.0 0.92 1.19 25 100 ±3 86 0.3 12 OLP 33.0 0.75 0.92 25 100 ±3 86 0.3 12 OLP 60 40.0 0.62 0.75 25 100 ±3 86 0.3 12 OLP 50 48.0 0.53 0.62 25 100 ±3 86 0.3 12 OLP ±3 86 0.3 12 OLP 110 100 70 80 100 120 55.0 48.0 140 160 180 200 220 INPUT VOLTAGE (VAC) (FIG.1) INPUT VOLTAGE DERATING CURVE 0.45 240 0.53 260 280 100 25 110 100 90 80 70 60 50 40 30 20 10 0 -10 ENSIONS: ( UNIT: mm ) Protection Mode Maximum Output Power AHP2501-01~04 Output Cord Length 48”, 18AWG Output Current AHP2501-05~09 Output Cord Length 48”, 20AWG Voltage Range (Based on theCord output volt.) AHP2501-110~112 Output Length 48”, 22AWG WWW.ASTRODYNETDI.COM 0 10 20 30 40 50 TEMPERATURE (°C) (FIG.2) TEMPERATURE DERATING CURVE 60 70 80 OUTPUT CABLE RECOMMEND : 1. Selected output connectors and wire, please refer to Appendix. 2. HPU25-101~104 are required to use AWG#18 2C/4FT output cable. 3. HPU25-105~109 are required to0315 use AWG#20 2C/4FT output cable. 4. HPU25-110~112 are required to use AWG#22 2C/4FT output cable. 5. The regulation and efficiency will be changed by modified output cable. ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458