Panasonic ERZV14D220 Â znrâ transient/surge absorbers (type d) Datasheet

“ZNR” Transient/Surge Absorbers (Type D)
“ZNR” Transient/Surge Absorbers
Type:
Series:
D
V
■ Features
■ Recommended Applications
■ Applicable Standards
■ Handling Precautions and Minimum Quantity /
● Large withstanding surge current capability in compact
sizes
● Large “Energy Handling Capability” absorbing transient
overvoltages in compact sizes
● Wide range of varistor voltages
● RoHS compliant
●
●
●
●
● Transistor, diode, IC, thyristor or triac semiconductor
protection
● Surge protection in consumer electronic equipment
● Surge protection in communication, measuring or
controller electronics
● Surge protection in electronic home appliances, gas or
petroleum appliances
UL1449 (VZCA2/UL, VZCA8/C-UL)
VDE IEC61051-1, -2, -2-2, IEC60950-1 Annex.Q
CSA C22.2 No.1
CQC(GB/T10193, GB/T10194, GB4943.1, GB8898)
Refer to page 5 to 8, and 27, for the details
Packing Unit
Please see Related Information
■ Explanation of Part Numbers (Bulk)
1
2
3
4
&
3
;
7
5
6
7
8
9
10
05
07
09
12
%
Series
Product Code
11
Design No.
Element Size
f10 mm
f5 mm
10
f14 mm
f7 mm
14
f20 mm
f10 mm
20
Lead Configuration
D Straight Lead
V Crimped Lead=
= Excluding f20.
= Only the lead cut
Norminal Varistor Voltage
The first two digits are significant
figures and the third one denotes
the number of zeros following.
■ Explanation of Part Numbers (Taping)
1
2
3
4
&
3
;
7
Product Code
A to D
E to H
5
6
7
8
9
11
12
%
Series
Taping / Packaging
Radial Taping (P0=12.7 mm)
Radial Taping (P0=15.0 mm)
10
Design No.
Element Size
f5 mm
5
f7 mm
7
f10 mm
9
f10 mm
A
f14 mm
E
Lead Configuration
D
Straight Lead
Crimped Lead
V
Nominal Varistor Voltage
The first two digits are significant
figures and the third one denotes
the number of zeros following.
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately.
02 Aug. 2013
–4–
“ZNR” Transient/Surge Absorbers (Type D)
■ Reference Guide to Standard Products
Part No.
Applicable
Standards
Varistor
Voltage ✽
Type Name Approvals
(V)
ERZV05D180
V180
◇
ERZV07D180
V7180
◇
ERZV09D180
V9180
◇
ERZV10D180
V10180
◇
ERZV14D180
V14180
◇
ERZV20D180
V20180
ERZV05D220
V220
ERZV07D220
Maximum
Clamping
Allowable
Voltage
Voltage
at 8/20μs
ACrms (V) DC (V) max.(V) Ip (A)
Maximum
Peak Current
at 8/20μs(A)
1 time 2 times
40
1
36
2.5
36
5
36
5
1000
500
36
10
2000
1000
◇
36
20
3000
2000
◇
48
1
250
125
V7220
◇
43
2.5
500
250
ERZV09D220
V9220
◇
43
5
1000
500
ERZV10D220
V10220
◇
ERZV14D220
V14220
◇
ERZV20D220
V20220
ERZV05D270
V270
ERZV07D270
18
(16 to 20)
22
(20 to 24)
11
14
14
18
250
125
500
250
1000
500
43
5
1000
500
43
10
2000
1000
◇
43
20
3000
2000
◇
60
1
250
125
V7270
◇
53
2.5
500
250
ERZV09D270
V9270
◇
53
5
1000
500
ERZV10D270
V10270
◇
53
5
1000
500
ERZV14D270
V14270
◇
53
10
2000
1000
ERZV20D270
V20270
◇
53
20
3000
2000
27
(24 to 30)
17
22
ERZV05D330
V330
◇
73
1
250
125
ERZV07D330
V7330
◇
65
2.5
500
250
ERZV09D330
V9330
◇
65
5
1000
500
ERZV10D330
V10330
◇
65
5
1000
500
ERZV14D330
V14330
◇
65
10
2000
1000
ERZV20D330
V20330
◇
65
20
3000
2000
ERZV05D390
V390
◇
86
1
250
125
ERZV07D390
V7390
◇
77
2.5
500
250
ERZV09D390
V9390
◇
77
5
1000
500
ERZV10D390
V10390
◇
77
5
1000
500
ERZV14D390
V14390
◇
77
10
2000
1000
ERZV20D390
V20390
◇
77
20
3000
2000
ERZV05D470
V470
◇
104
1
250
125
ERZV07D470
V7470
◇
93
2.5
500
250
ERZV09D470
V9470
◇
93
5
1000
500
ERZV10D470
V10470
◇
93
5
1000
500
ERZV14D470
V14470
◇
93
10
2000
1000
ERZV20D470
V20470
◇
93
20
3000
2000
ERZV05D560
V560
◇
123
1
250
125
ERZV07D560
V7560
◇
110
2.5
500
250
ERZV09D560
V9560
◇
110
5
1000
500
ERZV10D560
V10560
◇
110
5
1000
500
ERZV14D560
V14560
◇
110
10
2000
1000
ERZV20D560
V20560
◇
110
20
3000
2000
ERZV05D680
V680
◇
150
1
250
125
ERZV07D680
V7680
◇
135
2.5
500
250
ERZV09D680
V9680
◇
135
5
1000
500
ERZV10D680
V10680
◇
135
5
1000
500
ERZV14D680
V14680
◇
135
10
2000
1000
ERZV20D680
V20680
◇
135
20
3000
2000
33
(30 to 36)
39
(35 to 43)
47
(42 to 52)
56
(50 to 62)
68
(61 to 75)
20
25
30
35
40
26
31
38
45
56
Recommended Applications
For the low voltage circuit
✽ Measuring Current of Varistor Voltage 5 Series : 0.1 mA, Others: 1 mA
○ : UL1449 (VZCA2/UL, VZCA8/C-UL), ● : UL1449 Type3 (or Code-Connected and Direct plug-in), ◎ : UL1449 Type2 (or Permanently Connected),
☆ : VDE (IEC61051-1, -2, -2-2), ★ : VDE (IEC60950-1 Annex.Q), □ : CSA C22.2 No.1
◇ : CQC (GB/T10193, GB/T10194), ◆ : CQC (GB4943.1, GB8898)
※ Approval number (File No.) of safety regulations are subject to revision without notice. Ask factory for a copy of the latest file No.
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately.
02 Aug. 2013
–5–
“ZNR” Transient/Surge Absorbers (Type D)
■ Reference Guide to Standard Products
Part No.
Applicable
Standards
Type Name
Approvals
ERZV05D820
V820U
○☆◇
ERZV07D820
V7820U
○☆◇
ERZV09D820
V9820U
○☆◇
ERZV10D820 V10820U
○☆◇
ERZV14D820 V14820U
ERZV20D820 V20820U
Varistor
Voltage ✽
(V)
Maximum
Clamping
Maximum
Allowable
Voltage
Peak Current
Voltage
at 8/20μs
at 8/20μs(A)
ACrms (V) DC (V) max.(V) Ip (A) 1 time 2 times
145
5
800
600
135
10
1750
1250
135
25
3500
2500
135
25
3500
2500
○◎☆◇
135
50
6000
5000
○◎☆◇
135
100
10000
7000
82
(74 to 90)
50
65
ERZV05D101
V101U
○☆◇
175
5
800
600
ERZV07D101
V7101U
○☆◇
165
10
1750
1250
ERZV09D101
V9101U
○☆◇
165
25
3500
2500
100
(90 to 110)
60
85
ERZV10D101 V10101U
○☆◇
165
25
3500
2500
ERZV14D101 V14101U
○◎☆◇
165
50
6000
5000
ERZV20D101 V20101U
○◎☆◇
165
100
10000
V121U
○☆◇
210
5
800
ERZV07D121
V7121U
○☆◇
200
10
1750
1250
ERZV09D121
V9121U
○☆◇
200
25
3500
2500
ERZV10D121 V10121U
○☆◇
200
25
3500
2500
ERZV14D121 V14121U
○◎☆◇
200
50
6000
5000
ERZV20D121 V20121U
○◎☆◇
200
100
10000
7000
ERZV05D121
120
(108 to 132)
75
100
7000 Telephone, Communication Line
600 (DC 48 V)
ERZV05D151
V151U
○☆◇
260
5
800
600
ERZV07D151
V7151U
○☆◇
250
10
1750
1250
ERZV09D151
250
25
3500
2500
250
25
3500
2500
V9151U
○☆◇
ERZV10D151 V10151U
○☆◇
ERZV14D151 V14151U
○◎☆◇
250
50
6000
5000
ERZV20D151 V20151U
○◎☆◇
250
100
10000
7000
ERZV05D201
V201U
○☆□◇
355
5
800
600
ERZV07D201
V7201U
○☆□◇
340
10
1750
1250
ERZV09D201
V9201U
○☆□◇
340
25
3500
2500
ERZV10D201 V10201U
○☆□◇
340
25
3500
2500
ERZV14D201 V14201U ○◎☆★□◇◆
340
50
6000
5000
ERZV20D201 V20201U ○◎☆★□◇◆
340
100
10000
ERZV05D221
150
(135 to 165)
200
(185 to 225)
95
130
125
170
7000 AC 100 V Line–Line
600 Applications
V221U
○☆□◇
380
5
800
ERZV07D221
V7221U
○☆□◇
360
10
1750
1250
ERZV09D221
V9221U
○☆□◇
360
25
3500
2500
ERZV10D221 V10221U
○☆□◇
360
25
3500
2500
ERZV14D221 V14221U ○◎☆★□◇◆
360
50
6000
5000
ERZV20D221 V20221U ○◎☆★□◇◆
360
100
10000
7000
ERZV05D241
V241U
○☆□◇
415
5
800
600
ERZV07D241
V7241U
○☆□◇
395
10
1750
1250
ERZV09D241
V9241U
○☆□◇
395
25
3500
2500
ERZV10D241 V10241U
○☆□◇
395
25
3500
2500
ERZV14D241 V14241U ○◎☆★□◇◆
395
50
6000
5000
ERZV20D241 V20241U ○◎☆★□◇◆
395
100
10000
ERZV05D271
475
5
800
455
10
1750
1250
455
25
3500
2500
455
25
3500
2500
ERZV14D271 V14271U ○◎☆★□◇◆
455
50
6000
5000
ERZV20D271 V20271U ○◎☆★□◇◆
455
100
10000
7000
V271U
○☆□◇
ERZV07D271
V7271U
○☆□◇
ERZV09D271
V9271U
○☆□◇
ERZV10D271 V10271U
○☆□◇
220
(198 to 242)
240
(216 to 264)
270
(247 to 303)
140
150
175
180
200
225
Recommended Applications
7000 AC 100 V to 120 V, Line–Line
600 Applications
✽ Measuring Current of Varistor Voltage 5 Series : 0.1 mA, Others: 1 mA
○ : UL1449 (VZCA2/UL, VZCA8/C-UL), ● : UL1449 Type3 (or Code-Connected and Direct plug-in), ◎ : UL1449 Type2 (or Permanently Connected),
☆ : VDE (IEC61051-1, -2, -2-2), ★ : VDE (IEC60950-1 Annex.Q), □ : CSA C22.2 No.1
◇ : CQC (GB/T10193, GB/T10194), ◆ : CQC (GB4943.1, GB8898)
※ Approval number (File No.) of safety regulations are subject to revision without notice. Ask factory for a copy of the latest file No.
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately.
02 Aug. 2013
–6–
“ZNR” Transient/Surge Absorbers (Type D)
■ Reference Guide to Standard Products
Part No.
Applicable
Standards
Type Name
Approvals
Varistor
Voltage ✽
(V)
Maximum
Clamping
Maximum
Allowable
Voltage
Peak Current
Voltage
at 8/20μs
at 8/20μs(A)
ACrms (V) DC (V) max.(V) Ip (A) 1 time 2 times
ERZV05D331
V331U
○☆□◇
570
5
800
600
ERZV07D331
V7331U
○☆□◇
545
10
1750
1250
ERZV09D331
V9331U
○☆□◇
545
25
3500
2500
ERZV10D331 V10331U
○☆□◇
545
25
3500
2500
ERZV14D331 V14331U ○◎☆★□◇◆
545
50
6000
4500
ERZV20D331 V20331U ○◎☆★□◇◆
545
100
10000
6500
ERZV05D361
V361U
○☆□◇
620
5
800
600
ERZV07D361
V7361U
○☆□◇
595
10
1750
ERZV09D361
V9361U
○☆□◇
595
25
3500
ERZV10D361 V10361U
○☆□◇
595
25
3500
ERZV14D361 V14361U ○◎☆★□◇◆
595
50
6000
ERZV20D361 V20361U ○◎☆★□◇◆
595
100
10000
330
(297 to 363)
360
(324 to 396)
210
230
270
300
AC 100 V to 120 V, Line–Line
1250 Applications
2500
2500 Telephone Line Applications,
4500 (For DC 250 V Insulation
Resistance Test)
6500
ERZV05D391
V391U
○☆□◇
675
5
800
600
ERZV07D391
V7391U
○☆□◇
650
10
1750
1250
ERZV09D391
V9391U
○☆□◇
650
25
3500
2500
ERZV10D391 V10391U
○☆□◇
650
25
3500
2500
390
(351 to 429)
250
320
ERZV14D391 V14391U ○◎☆★□◇◆
650
50
6000
4500
ERZV20D391 V20391U ○◎☆★□◇◆
650
100
10000
6500
ERZV05D431
V431U
○☆□◇
745
5
800
600
ERZV07D431
V7431U
○☆□◇
710
10
1750
1250
ERZV09D431
V9431U
○☆□◇
710
25
3500
2500
ERZV10D431 V10431U
○☆□◇
710
25
3500
2500
ERZV14D431 V14431U ○◎☆★□◇◆
710
50
6000
4500
ERZV20D431 V20431U ○◎☆★□◇◆
710
100
10000
430
(387 to 473)
275
350
Recommended Applications
ERZV05D471
V471U
○☆□◇
810
5
800
ERZV07D471
V7471U
○☆□◇
775
10
1750
6500 AC 100 V to 220 V, Line–Line
and
600 Line–Ground Applications
1250
775
25
3500
2500
775
25
3500
2500
ERZV14D471 V14471U ○◎☆★□◇◆
775
50
6000
4500
ERZV20D471 V20471U ○◎☆★□◇◆
775
100
10000
6500
ERZV07D511
V7511U
○☆□◇
845
10
1750
1250
ERZV09D511
V9511U
○☆□◇
845
25
3500
2500
845
25
3500
2500
ERZV09D471
V9471U
○☆□◇
470
ERZV10D471 V10471U ○●☆★□◇◆ (423 to 517)
ERZV10D511 V10511U ○●☆★□◇◆
ERZV14D511 V14511U ○◎☆★□◇◆
510
(459 to 561)
300
320
385
410
845
50
6000
4500
ERZV20D511 V20511U ○◎☆★□◇◆
845
100
10000
6500
ERZV10D561 V10561U ○●☆★□◇◆
930
25
3500
930
50
5000
7500
ERZV14D561 V14561U ○◎☆★□◇◆
ERZV20D561 V20561U ○◎☆★□◇◆
ERZV10D621 V10621U ○●☆★□◇◆
ERZV14D621 V14621U ○◎☆★□◇◆
ERZV20D621 V20621U ○◎☆★□◇◆
ERZV10D681 V10681U ○●☆★□◇◆
ERZV14D681 V14681U ○◎☆★□◇◆
ERZV20D681 V20681U ○◎☆★□◇◆
560
(504 to 616)
350
620
(558 to 682)
385
680
(612 to 748)
420
450
505
560
930
100
1025
25
3500
2500
4500 AC 100 to 240 V, Line–Line
and
6500 Line–Ground Applications
2500
1025
50
5000
4500
1025
100
7500
6500
1120
25
3500
2500
1120
50
5000
4500
1120
100
7500
6500
✽ Measuring Current of Varistor Voltage 5 Series : 0.1 mA, Others: 1 mA
○ : UL1449 (VZCA2/UL, VZCA8/C-UL), ● : UL1449 Type3 (or Code-Connected and Direct plug-in), ◎ : UL1449 Type2 (or Permanently Connected),
☆ : VDE (IEC61051-1, -2, -2-2), ★ : VDE (IEC60950-1 Annex.Q), □ : CSA C22.2 No.1
◇ : CQC (GB/T10193, GB/T10194), ◆ : CQC (GB4943.1, GB8898)
※ Approval number (File No.) of safety regulations are subject to revision without notice. Ask factory for a copy of the latest file No.
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately.
02 Aug. 2013
–7–
“ZNR” Transient/Surge Absorbers (Type D)
■ Reference Guide to Standard Products
Part No.
Applicable
Standards
Type Name
Approvals
ERZV10D751
V10751U ○●☆★□◇◆
ERZV14D751
V14751U ○◎☆★□◇◆
ERZV20D751
V20751U ○◎☆★□◇◆
ERZV10D821
V10821U ○●☆★□◇◆
ERZV14D821
V14821U ○◎☆★□◇◆
ERZV20D821
V20821U ○◎☆★□◇◆
ERZV10D911
V10911U ○●☆★□◇◆
Varistor
Voltage ✽
(V)
750
(675 to 825)
460
820
(738 to 902)
510
ERZV20D911
910
V14911U ○◎☆★□◇◆
(819 to 1001)
V20911U ○◎☆★□◇◆
ERZV10D102
V10102U ○●☆★□◇◆
ERZV14D102
V14102U ○◎☆★□◇◆
ERZV20D102
V20102U ○◎☆★□◇◆
ERZV10D112
V10112U ○●☆★□◇◆
ERZV14D112
V14112U ○◎☆★□◇◆
ERZV20D112
V20112U ○◎☆★□◇◆
ERZV14D911
Maximum
Clamping
Maximum
Allowable
Voltage
Peak Current
Voltage
at 8/20μs
at 8/20μs(A)
ACrms (V) DC (V) max.(V) Ip (A) 1 time 2 times
550
1000
(900 to 1100)
625
1100
(990 to 1210)
680
615
670
745
825
895
ERZV10D182CS V10182U ○●☆★□◇◆
1800
1000
ERZV14D182CS V14182U ○◎☆★□◇◆
(1700 to 1980)
ERZV20D182 V20182U ○◎☆★□◇◆
1465
1240
25
3500
2500
1240
50
5000
4500
1240
100
7500
6500
1355
25
3500
2500
1355
50
5000
4500
1355
100
7500
6500
1500
25
3500
2500
1500
50
5000
4500
1500
100
7500
6500
1650
25
3500
2500
1650
50
5000
4500
1650
100
7500
6500
1815
25
3500
2500
1815
50
5000
4500
1815
100
7500
6500
2970
25
3500
2500
2970
50
5000
4500
2970
100
7500
6500
Recommended Applications
AC 380 V, Line–Line and
Line–Ground Applications
(For DC 500 V Insulating Test)
AC 415 V, Line–Line and
Line–Ground Applications
(For DC 500 V Insulating Test)
AC 480 V, Line–Line and
Line–Ground Applications
(For DC 500 V Insulating Test)
Line–Ground Applications
(For AC 1200 V Withstanding
Test)
✽ Measuring Current of Varistor Voltage 5 Series : 0.1 mA, Others: 1 mA
○ : UL1449 (VZCA2/UL, VZCA8/C-UL), ● : UL1449 Type3 (or Code-Connected and Direct plug-in), ◎ : UL1449 Type2 (or Permanently Connected),
☆ : VDE (IEC61051-1, -2, -2-2), ★ : VDE (IEC60950-1 Annex.Q), □ : CSA C22.2 No.1
◇ : CQC (GB/T10193, GB/T10194), ◆ : CQC (GB4943.1, GB8898)
※ Approval number (File No.) of safety regulations are subject to revision without notice. Ask factory for a copy of the latest file No.
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately.
02 Aug. 2013
–8–
“ZNR” Transient/Surge Absorbers (Type D)
5 Series
■ Ratings and Characteristics
● Operating Temperature Range
Maximum
Allowable
Voltage
Varistor
Voltage
Part No.
Clamping
Voltage
(max.)
✽✽
Ip
Rated
Power
Maximum
Peak Current Capacitance
(8/20 μs)
(max.)
(10/1000 μs) (2 ms) 1 time 2 times
Maximum
Energy
V0.1 mA (V)
ACrms (V)
DC (V)
(V)
(W)
(J)
(J)
(A)
(A)
at 1 kHz (pF)
18(16 to 20)
22(20 to 24)
27(24 to 30)
33(30 to 36)
39(35 to 43)
47(42 to 52)
56(50 to 62)
68(61 to 75)
82(74 to 90)
100(90 to 110)
120(108 to 132)
150(135 to 165)
200(185 to 225)
220(198 to 242)
240(216 to 264)
270(247 to 303)
330(297 to 363)
360(324 to 396)
390(351 to 429)
430(387 to 473)
470(423 to 517)
11
14
17
20
25
30
35
40
50
60
75
95
130
140
150
175
210
230
250
275
300
14
18
22
26
31
38
45
56
65
85
100
125
170
180
200
225
270
300
320
350
385
40
48
60
73
86
104
123
150
145
175
210
260
355
380
415
475
570
620
675
745
810
0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.6
0.7
0.9
1.1
1.2
1.5
1.8
2.2
3.5
4.0
5.0
6.5
8.5
9.0
10.5
11.0
13.0
16.0
17.0
20.0
21.0
0.4
0.5
0.7
0.8
0.9
1.1
1.3
1.6
2.5
3.0
3.5
4.5
6.0
6.5
7.5
8.0
9.5
11.0
12.0
13.5
15.0
250
250
250
250
250
250
250
250
800
800
800
800
800
800
800
800
800
800
800
800
800
125
125
125
125
125
125
125
125
600
600
600
600
600
600
600
600
600
600
600
600
600
1600
1500
1450
1400
700
650
600
580
460
400
350
300
120
110
100
90 ✽
80 ✽
80 ✽
80 ✽
70 ✽
60 ✽
✽✽Ip Measuring current of clamping voltage 180 to 680 : 1 A, 820 to 471 : 5 A
✽ Refer to page 24 to 26 about leads cut type and taping.
Part No.
D max.
T max.
W±1.0
H max.
L±1.0
ERZV05D180
ERZV05D220
ERZV05D270
ERZV05D330
ERZV05D390
ERZV05D470
ERZV05D560
ERZV05D680
ERZV05D820
ERZV05D101
ERZV05D121
ERZV05D151
ERZV05D201
ERZV05D221
ERZV05D241
ERZV05D271
ERZV05D331
ERZV05D361
ERZV05D391
ERZV05D431
ERZV05D471
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.1
4.3
4.5
4.8
4.4
4.5
4.6
4.8
5.1
5.3
5.4
5.6
5.8
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.4
1.6
1.8
2.1
1.7
1.8
1.9
2.1
2.4
2.5
2.7
2.9
3.1
D
T
L
W
f0.6
L
■ Dimensions in mm (not to scale)
H
✽ Measured at 1 MHz
20.0 min.
ERZV05D180
ERZV05D220
ERZV05D270
ERZV05D330
ERZV05D390
ERZV05D470
ERZV05D560
ERZV05D680
ERZV05D820
ERZV05D101
ERZV05D121
ERZV05D151
ERZV05D201
ERZV05D221
ERZV05D241
ERZV05D271
ERZV05D331
ERZV05D361
ERZV05D391
ERZV05D431
ERZV05D471
: –40 to 85 °C ● Storage Temperature Range : –40 to 125 °C
W
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately.
01 Aug. 2012
–9–
“ZNR” Transient/Surge Absorbers (Type D)
■ Typical Characteristics
Impulse Derating (Relation between impulse
Voltage vs. Current
width and impulse current multiple)
ERZV05D180 to ERZV05D680
ERZV05D180 to ERZV05D680
1000
Max. Clamping Voltage
Max.
400 Leakage Current
300
470
390
330
200
2
Ti
m
es
Impulse Current (A)
e
m
Ti
10
9
8
7
6
10
m
0
27 0
22
0
18
20
10
3
10 4 Ti
m
Ti es
10 5 me
10 6 Tim s
Tim es
es
10
Ti
0
33
10
30
es
m
Ti
40
2
0
68
0
56
0
47
1
100
90
80
70
60
50
100
270
220
180
390
Voltage (V)
2 times : 5 min. interval
up to 10 times : 2 min. interval
up to 106 times : 10 sec. interval
680
560
es
1
Test current waveform
10–6 to 10–4 A: Direct current
10–1 to 103 A: 8/20 μs
5
4
3
10–6
10–5
10–4
10–2
10–3
10–1
100
Current (A)
101
102
103
104
ERZV05D820 to ERZV05D471
0.1
20
105
100
1000
Impulse Width (μs)
10000
ERZV05D820 to ERZV05D471
1000
2000
2 times : 5 min. interval
up to 10 times : 2 min. interval
up to 106 times : 10 sec. interval
100
100
90
80
70
60
50
40
Surge Current (A)
Voltage (V)
200
820
10 6
1
20
1
15
1
12
Tim
es
1
1
10
0
82
Test Current Waveform
10-6 to 10-4 A: Direct Current
10-1 to 103 A: 8/20 μs
331
221
30
10-6
e
101
271
241
es
Tim
121
300
m
151
1
47
3
Ti
10 4 me
s
Tim
10 5 es
Tim
10
es
2
400
Ti
es s
Tim ime
2 T
10
10
500
1
471
431
391
361
331
271
241
221
201
10
1000
900
800
700
600
.BY$MBNQJOH7PMUBHF
.BY
-FBLBHF$VSSFOU
10-5
10-4
10-3
10-2
10-1
100
Current (A)
101
102
103
104
105
0.1
20
100
1000
Impulse Width (μs)
10000
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately.
01 Aug. 2012
– 10 –
“ZNR” Transient/Surge Absorbers (Type D)
7 Series
■ Ratings and Characteristics
● Operating Temperature Range: –40 to 85 °C ● Storage Temperature Range: –40 to 125 °C
Varistor
Voltage
Part No.
Clamping
Voltage
(max.)
✽✽
Ip
Rated
Power
Maximum
Peak Current Capacitance
(8/20 μs)
(max.)
(10/1000 μs) (2 ms) 1 time 2 times
Maximum
Energy
V1 mA (V)
ACrms (V)
DC (V)
(V)
(W)
(J)
(J)
(A)
(A)
at 1 kHz (pF)
18(16 to 20)
22(20 to 24)
27(24 to 30)
33(30 to 36)
39(35 to 43)
47(42 to 52)
56(50 to 62)
68(61 to 75)
82(74 to 90)
100(90 to 110)
120(108 to 132)
150(135 to 165)
200(185 to 225)
220(198 to 242)
240(216 to 264)
270(247 to 303)
330(297 to 363)
360(324 to 396)
390(351 to 429)
430(387 to 473)
470(423 to 517)
510(459 to 561)
11
14
17
20
25
30
35
40
50
60
75
95
130
140
150
175
210
230
250
275
300
320
14
18
22
26
31
38
45
56
65
85
100
125
170
180
200
225
270
300
320
350
385
410
36
43
53
65
77
93
110
135
135
165
200
250
340
360
395
455
545
595
650
710
775
845
0.02
0.02
0.02
0.02
0.02
0.02
0.02
0.02
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
1.1
1.3
1.6
2.0
2.4
2.8
3.4
4.1
7
8.5
10
13
17.5
19
21
24
28
32
35
40
42
45
0.9
1.1
1.3
1.6
1.9
2.3
2.7
3.3
5
6
7
9
12.5
13.5
15
17
20
23
25
27.5
30
32
500
500
500
500
500
500
500
500
1750
1750
1750
1750
1750
1750
1750
1750
1750
1750
1750
1750
1750
1750
250
250
250
250
250
250
250
250
1250
1250
1250
1250
1250
1250
1250
1250
1250
1250
1250
1250
1250
1250
3800
3600
3400
2900
1600
1550
1500
1200
810
700
590
500
200
190
170
150
130
130
130
120
100
90 ✽
✽✽Ip Measuring current of clamping voltage 180 to 680 : 25 A, 820 tp 511 : 10 A
✽ Refer to page 24 to 26 about leads cut type and taping.
Part No.
D max.
T max.
W±1.0
H max.
L±1.0
ERZV07D180
ERZV07D220
ERZV07D270
ERZV07D330
ERZV07D390
ERZV07D470
ERZV07D560
ERZV07D680
ERZV07D820
ERZV07D101
ERZV07D121
ERZV07D151
ERZV07D201
ERZV07D221
ERZV07D241
ERZV07D271
ERZV07D331
ERZV07D361
ERZV07D391
ERZV07D431
ERZV07D471
ERZV07D511
8.5
8.5
8.5
8.5
8.5
8.5
8.5
8.5
8.5
8.5
8.5
8.5
8.5
8.5
8.5
8.5
8.5
8.5
8.5
8.5
8.5
8.5
4.5
4.6
4.7
4.9
4.8
4.9
5.0
5.2
4.1
4.3
4.5
4.8
4.4
4.5
4.6
4.8
5.1
5.3
5.4
5.6
5.8
6.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
11.5
11.5
11.5
11.5
11.5
11.5
11.5
11.5
11.5
11.5
11.5
11.5
11.5
11.5
11.5
11.5
11.5
11.5
11.5
11.5
11.5
11.5
1.3
1.4
1.5
1.7
1.6
1.7
1.8
2.0
1.4
1.6
1.8
2.1
1.7
1.8
1.9
2.1
2.4
2.5
2.7
2.9
3.1
3.3
D
T
L
W
f 0.6
L
■ Dimensions in mm (not to scale)
H
✽ Measured at 1 MHz
20.0 min.
ERZV07D180
ERZV07D220
ERZV07D270
ERZV07D330
ERZV07D390
ERZV07D470
ERZV07D560
ERZV07D680
ERZV07D820
ERZV07D101
ERZV07D121
ERZV07D151
ERZV07D201
ERZV07D221
ERZV07D241
ERZV07D271
ERZV07D331
ERZV07D361
ERZV07D391
ERZV07D431
ERZV07D471
ERZV07D511
Maximum
Allowable
Voltage
W
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately.
01 Aug. 2012
– 11 –
“ZNR” Transient/Surge Absorbers (Type D)
■Typical Characteristics
Impulse Derating (Relation between impulse
Voltage vs. Current
width and impulse current multiple)
ERZV07D180 to ERZV07D680
ERZV07D180 to ERZV07D680
1000
Max. Clamping Voltage
Max.
Leakage Current
400
100
e
m
es
Ti
im
1
es
T
m
Ti
10
2
10
10
3
10 4 Tim
Tim es
e
10 5 s
T
10 10 6 ime
Tim s
es
Impulse Current (A)
0
0
56
0
7
4 0
39
330
270
40
30
20
es
68
2
m
Ti
Voltage (V)
200
100
90
80
70
60
50
2 times : 5 min. interval
up to 10 times : 2 min. interval
up to 106 times : 10 sec. interval
680
560
470
390
330
270
220
180
300
0
22
0
18
10
9
8
7
6
5
1
Test current waveform
10–6 to 10–3 A: Direct current
10–1 to 103 A: 8/20 μs
4
3
10–6
10–5
10–4
10–3
10–2
10–1
100
101
102
103
104
0.1
20
105
100
Current (A)
1000
10000
Impulse Width (μs)
ERZV07D820 to ERZV07D511
ERZV07D820 to ERZV07D511
10000
471
431
391
361
es
Tim
10-1
100
Current (A)
101
102
103
104
105
1
20
Voltage (V)
e
10-2
es
Tim
10-3
Tim
10-4
Ti
10
10-5
5
m
101
820
Test Current Waveform
10-6 to 10-3 A: Direct Current
10-1 to 104 A: 8/20 μs
1
10
10
331
221
es
30
10-6
es es
m im
4 T
10
40
201
151
121
100
Ti
100
90
80
70
60
50
271
241
3
200
10
820
m
101
300
Ti
121
2
151
511
10
500
400
1000
2
1000
900
800
700
600
2 times : 5 min. interval
up to 10 times : 2 min. interval
up to 106 times : 10 sec. interval
511
471
431
391
361
331
271
241
221
201
Surge Current (A)
2000
.BY$MBNQJOH7PMUBHF
.BY
-FBLBHF$VSSFOU
es
10
6
Ti
m
es
100
1000
Impulse Width (μs)
10000
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately.
01 Aug. 2012
– 12 –
“ZNR” Transient/Surge Absorbers (Type D)
9 Series
■ Ratings and Characteristics
● Operating Temperature Range : –40 to 85 °C
Part No.
ERZV09D180
ERZV09D220
ERZV09D270
ERZV09D330
ERZV09D390
ERZV09D470
ERZV09D560
ERZV09D680
ERZV09D820
ERZV09D101
ERZV09D121
ERZV09D151
ERZV09D201
ERZV09D221
ERZV09D241
ERZV09D271
ERZV09D331
ERZV09D361
ERZV09D391
ERZV09D431
ERZV09D471
ERZV09D511
● Storage Temperature Range : –40 to 125 °C
Maximum
Allowable
Voltage
Varistor
Voltage
Clamping
Voltage
(max.)
✽
Ip
Rated
Power
Maximum
Peak Current Capacitance
(8/20 μs)
(max.)
(10/1000 μs) (2 ms) 1 time 2 times
Maximum
Energy
V1 mA (V)
ACrms (V)
DC (V)
(V)
(W)
(J)
(J)
(A)
(A)
at 1 kHz (pF)
18(16 to 20)
22(20 to 24)
27(24 to 30)
33(30 to 36)
39(35 to 43)
47(42 to 52)
56(50 to 62)
68(61 to 75)
82(74 to 90)
100(90 to 110)
120(108 to 132)
150(135 to 165)
200(185 to 225)
220(198 to 242)
240(216 to 264)
270(247 to 303)
330(297 to 363)
360(324 to 396)
390(351 to 429)
430(387 to 473)
470(423 to 517)
510(459 to 561)
11
14
17
20
25
30
35
40
50
60
75
95
130
140
150
175
210
230
250
275
300
320
14
18
22
26
31
38
45
56
65
85
100
125
170
180
200
225
270
300
320
350
385
410
36
43
53
65
77
93
110
135
135
165
200
250
340
360
395
455
545
595
650
710
775
845
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
2.6
3.2
3.9
4.8
5.6
6.8
8.1
9.8
14
17
20
25
35
39
42
49
58
65
70
80
85
92
2.2
2.6
3.2
4.0
4.7
5.6
6.7
8.2
10
12
14.5
18
25
27.5
30
35
42
45
50
55
60
67
1000
1000
1000
1000
1000
1000
1000
1000
3500
3500
3500
3500
3500
3500
3500
3500
3500
3500
3500
3500
3500
3500
500
500
500
500
500
500
500
500
2500
2500
2500
2500
2500
2500
2500
2500
2500
2500
2500
2500
2500
2500
16000
11000
8000
6300
5200
4600
3750
2800
2000
1700
1400
1100
430
410
380
350
300
300
300
270
230
210
✽Ip Measuring current of clamping voltage 180 to 680 : 5 A, 820 to 511 : 25 A
✽ Refer to page 24 to 26 about leads cut type and taping.
T max.
W±1.0
H max.
L±1.0
ERZV09D180
ERZV09D220
ERZV09D270
ERZV09D330
ERZV09D390
ERZV09D470
ERZV09D560
ERZV09D680
ERZV09D820
ERZV09D101
ERZV09D121
ERZV09D151
ERZV09D201
ERZV09D221
ERZV09D241
ERZV09D271
ERZV09D331
ERZV09D361
ERZV09D391
ERZV09D431
ERZV09D471
ERZV09D511
11.5
11.5
11.5
11.5
11.5
11.5
11.5
11.5
11.5
11.5
11.5
11.5
11.5
11.5
11.5
11.5
11.5
11.5
11.5
11.5
11.5
11.5
3.8
4.0
4.2
4.5
4.0
4.2
4.4
4.5
3.8
3.9
4.1
4.4
4.1
4.2
4.3
4.5
4.8
5.0
5.1
5.3
5.6
5.8
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
14.0
14.0
14.0
14.0
14.0
14.0
14.0
14.0
14.0
14.0
14.0
14.0
14.0
14.0
14.0
14.0
14.0
14.0
14.0
14.0
14.0
14.0
1.3
1.4
1.5
1.7
1.7
1.8
1.9
2.2
1.6
1.8
2.0
2.2
1.7
1.8
1.9
2.0
2.3
2.5
2.6
2.8
3.1
3.2
D
T
L
W
f 0.6
L
D max.
H
Part No.
20.0 min.
■ Dimensions in mm (not to scale)
W
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately.
01 Aug. 2012
– 13 –
“ZNR” Transient/Surge Absorbers (Type D)
■ Typical Characteristics
Impulse Derating (Relation between impulse
Voltage vs. Current
width and impulse current multiple)
ERZV09D180 to ERZV09D680
ERZV09D180 to ERZV09D680
400
1000
Max. Clamping Voltage
Max.
Leakage Current
680
560
470
390
330
270
300
200
2 times : 5 min. interval
up to 10 times : 2 min. interval
up to 106 times : 10 sec. interval
1
Impulse Current (A)
0
68
0
56 470
0
39
40
30
20
0
33
0
27
0
2
2
0
8
1
10
9
8
7
6
10
03
Ti
10 me
4
s
10 5 Tim
Tim es
es
10 6
Tim
e
2
Voltage (V)
100 1
180
100
90
80
70
60
50
e
es
m
es
Ti
m
m
Ti
Ti
10
220
10
2
Ti
m
es
s
1
Test current waveform
10–6 to 10–3 A: Direct current
10–1 to 103 A: 8/20 μs
5
4
3
10–6
10–5
10–4
10–3
10–2
10–1
100
Current (A)
101
102
103
104
0.1
20
105
100
1000
10000
Impulse Width (μs)
ERZV09D820 to ERZV09D511
ERZV09D820 to ERZV09D511
10000
471
431
391
361
Voltage (V)
100
90
80
70
60
50
10 6
10
Tim
es
Test Current Waveform
10-6 to 10-3 A: Direct Current
10-1 to 104 A: 8/20 μs
331
221
10-5
e
201
151
121
101
820
Ti
m
10 5 es
Tim
es
es
271
241
200
4
im
820
100
im
300
10
2T
121
101
1T
511
400
30
10-6
es es
Tim im
es
T
im
3 T
10
2
10
151
500
40
1000
10
1000
900
800
700
600
2 times : 5 min. interval
up to 10 times : 2 min. interval
up to 106 times : 10 sec. interval
511
471
431
391
361
331
271
241
221
201
Surge Current (A)
2000
.BY$MBNQJOH7PMUBHF
.BY
-FBLBHF$VSSFOU
10-4
10-3
10-2
10-1
100
101
102
103
Current (A)
104
105
1
20
100
1000
Impulse Width (μs)
10000
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately.
01 Aug. 2012
– 14 –
“ZNR” Transient/Surge Absorbers (Type D)
10 Series
■ Ratings and Characteristics
● Operating Temperature Range : –40 to 85 °C
● Storage Temperature Range : –40 to 125 °C
Clamping
Voltage
(max.)
✽✽
Ip
Maximum
Allowable
Voltage
Maximum
Peak Current Capacitance
(8/20 µs)
(max.)
(10/1000 µs) (2 ms) 1 time 2 times
Maximum
Energy
Part No.
Varistor
Voltage
(A)
at 1 kHz (pF)
ERZV10D180
18(16 to 20)
11
14
36
0.05
2.6
2.2 1000
500
16000
ERZV10D220
22(20 to 24)
14
18
43
0.05
3.2
2.6
500
11000
V1 mA (V)
ACrms (V)
DC (V)
(V)
Rated
Power
(W)
(J)
(J)
(A)
1000
ERZV10D270
27(24 to 30)
17
22
53
0.05
3.9
3.2 1000
500
8000
ERZV10D330
33(30 to 36)
20
26
65
0.05
4.8
4.0
1000
500
6300
ERZV10D390
39(35 to 43)
25
31
77
0.05
5.6
4.7
1000
500
5200
ERZV10D470
47(42 to 52)
30
38
93
0.05
6.8
5.6
1000
500
4600
ERZV10D560
56(50 to 62)
35
45
110
0.05
8.1
6.7
1000
500
3750
ERZV10D680
68(61 to 75)
40
56
135
0.05
9.8
8.2 1000
500
2800
ERZV10D820
82(74 to 90)
50
65
135
0.4
14
10
3500 2500
2000
ERZV10D101
100(90 to 110)
60
85
165
0.4
17
12
3500 2500
1700
ERZV10D121
120(108 to 132)
75
100
200
0.4
20
14.5 3500 2500
1400
ERZV10D151
150(135 to 165)
95
125
250
0.4
25
18
3500 2500
1100
ERZV10D201
200(185 to 225)
130
170
340
0.4
35
25
3500 2500
430
ERZV10D221
220(198 to 242)
140
180
360
0.4
39
27.5 3500 2500
410
ERZV10D241
240(216 to 264)
150
200
395
0.4
42
30
3500 2500
380
ERZV10D271
270(247 to 303)
175
225
455
0.4
49
35
3500 2500
350
ERZV10D331
330(297 to 363)
210
270
545
0.4
58
42
3500 2500
300
ERZV10D361
360(324 to 396)
230
300
595
0.4
65
45
3500 2500
300
ERZV10D391
390(351 to 429)
250
320
650
0.4
70
50
3500 2500
300
ERZV10D431
430(387 to 473)
275
350
710
0.4
80
55
3500 2500
270
ERZV10D471
470(423 to 517)
300
385
775
0.4
85
60
3500 2500
230
ERZV10D511
510(459 to 561)
320
410
845
0.4
92
67
3500 2500
210
ERZV10D561
560(504 to 616)
350
450
930
0.4
92
67
3500 2500
200
ERZV10D621
620(558 to 682)
385
505
1025
0.4
92
67
3500 2500
190
ERZV10D681
680(612 to 748)
420
560
1120
0.4
92
67
3500 2500
170
ERZV10D751
750(675 to 825)
460
615
1240
0.4
100
70
3500 2500
160
ERZV10D821
820(738 to 902)
510
670
1355
0.4
110
80
3500 2500
140
ERZV10D911
910(819 to 1001)
550
745
1500
0.4
130
90
3500 2500
120
ERZV10D102 1000(900 to 1100)
625
825
1650
0.4
140
100
3500 2500
110
1100(990 to 1210)
680
895
1815
0.4
155
110
3500 2500
110
ERZV10D182CS 1800(1700 to 1980)
1000
1465
2970
0.4
247
183
3500 2500
ERZV10D112
✽ Measured at 1 MHz
70 ✽
✽✽Ip Measuring current of clamping voltage 180 to 680 : 5 A, 820 to 182 : 25 A
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately.
01 Aug. 2012
– 15 –
“ZNR” Transient/Surge Absorbers (Type D)
✽ Refer to page 24 to 26 about leads cut type and taping.
D
T
1.3
1.4
1.5
1.7
1.6
1.7
1.8
2.0
W
1.6
1.8
f 0.8
2.0
2.3
1.9
2.0
2.1
2.3
(ERZV10D182CS)
2.6
2.8
D
2.9
3.1
3.3
3.5
3.8
4.2
f 0.8
4.5
4.9
5.2
5.7
6.2
6.8
10.0(±1.5)
L
L
L±1.0
W
T
L
14.5
14.5
14.5
14.5
14.5
14.5
14.5
14.5
14.5
14.5
14.5
14.5
14.5
14.5
14.5
14.5
14.5
14.5
14.5
14.5
14.5
14.5
15.5
15.5
15.5
15.5
15.5
15.5
15.5
15.5
16.5
2
H max.
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
11.0✽
W
W±1.0
4.6
4.7
4.8
5.0
4.9
5.0
5.1
5.3
4.5
4.7
4.9
5.2
4.8
4.9
5.0
5.2
5.5
5.7
5.8
6.0
6.2
6.4
6.7
7.1
7.4
7.8
8.1
8.6
9.1
9.7
14.4
H
T max.
11.5
11.5
11.5
11.5
11.5
11.5
11.5
11.5
11.5
11.5
11.5
11.5
11.5
11.5
11.5
11.5
11.5
11.5
11.5
11.5
11.5
11.5
12.5
12.5
12.5
12.5
12.5
12.5
12.5
12.5
13.5
20.0 min.
D max.
H
Part No.
ERZV10D180
ERZV10D220
ERZV10D270
ERZV10D330
ERZV10D390
ERZV10D470
ERZV10D560
ERZV10D680
ERZV10D820
ERZV10D101
ERZV10D121
ERZV10D151
ERZV10D201
ERZV10D221
ERZV10D241
ERZV10D271
ERZV10D331
ERZV10D361
ERZV10D391
ERZV10D431
ERZV10D471
ERZV10D511
ERZV10D561
ERZV10D621
ERZV10D681
ERZV10D751
ERZV10D821
ERZV10D911
ERZV10D102
ERZV10D112
ERZV10D182CS
4.0 ±1.5
■ Dimensions in mm (not to scale)
L
✽: W2
■ Typical Characteristics
Impulse Derating (Relation between impulse
Voltage vs. Current
width and impulse current multiple)
ERZV10D180 to ERZV10D680
1000
Max. Clamping Voltage
2 times : 5 min. interval
up to 10 times : 2 min. interval
up to 106 times : 10 sec. interval
680
560
470
390
330
270
300
200
1
100
Impulse Current (A)
Max.
Leakage Current
400
ERZV10D180 to ERZV10D680
220
180
Voltage (V)
100
90
80
70
60
50
0
68
0
56 0
47
0
39
40
30
10
9
8
7
6
T
10 4 ime
10 5 Ti
m
Ti e
m
e
10 6
10
0.1
20
Tim
Tim
e
e
Tim
1
10 2 0 Ti
Tim me
e
e
100
1000
Impulse Width (µs)
10000
Test current waveform
10–6 to 10–3 A: Direct current
10–1 to 103 A: 8/20 µs
5
4
3
2
1
0
33
0
27
0
2
2
0
18
20
10 3
10–6
10–5
10–4
10–3
10–2
10–1
100
101
102
103
104
105
Current (A)
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately.
01 Aug. 2012
– 16 –
“ZNR” Transient/Surge Absorbers (Type D)
■ Typical Characteristics
Impulse Derating (Relation between impulse
Voltage vs. Current
width and impulse current multiple)
ERZV10D820 to ERZV10D511
ERZV10D820 to ERZV10D511
10000
Voltage (V)
30
10-6
10 6
Surge Current (A)
10
271
241
1
20
1000
121
101
ERZV10D561 to ERZV10D112
10000
820
2 times : 5 min. interval
up to 10 times : 2 min. interval
up to 106 times : 10 sec. interval
Test Current Waveform
10-6 to 10-3 A: Direct Current
10-1 to 104 A: 8/20 µs
331
221
10-5
10-4
10-3
10-2
101
102
103
104
1000
105
10
10 2 Tim
e
10 3 Tim s
Tim es
10 4 es
T
100 10 5 imes
Time
s
e
m
Ti s
1 ime
T
2
10-1
100
Current (A)
10 6
10
.BY$MBNQJOH7PMUBHF
.BY
-FBLBHF$VSSFOU
Tim
es
182CS
102
911
821
1
20
112
102
911
821
751
681
621
561
S
2C
18
10000
Impulse Width (µs)
2000
100
1000
10000
Impulse Width (µs)
ERZV10D182CS
10000
2 times : 5 min. interval
up to 10 times : 2 min. interval
up to 106 times : 10 sec. interval
1000
900
800
1000
2
11
2
700
10 4
T
ime
1
56
10
300
200
10-6
751
681
621
10-5
Tim 10 2 Tim
es Ti es
m
es
s1
0 5T
ime
s
10 6
Tim
es
e
400
100
es
10
m
500
m
Ti
600
10 3
Ti
1
Surge Current (A)
Voltage (V)
es
100
201
151
5000
3000
Tim
820
ERZV10D561 to ERZV10D182CS
4000
e
m
40
Ti
100
90
80
70
60
50
es
m
121
101
511
10
10 Tim
2
10 3 Tim es
T
10 4 im es
T es
100 10 5 ime
Tim s
es
Ti
151
300
200
1000
2
471
431
391
361
500
400
2 times : 5 min. interval
up to 10 times : 2 min. interval
up to 106 times : 10 sec. interval
511
471
431
391
361
331
271
241
221
201
1
1000
900
800
700
600
.BY$MBNQJOH7PMUBHF
.BY
-FBLBHF$VSSFOU
Surge Current (A)
2000
Test Current Waveform
10-6 to 10-3 A: Direct Current
10-1 to 104 A: 8/20 µs
10-4
10-3
10-2
10-1
100
Current (A)
101
102
103
104
105
1
20
100
1000
10000
Impulse Width (µs)
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately.
01 Aug. 2012
– 17 –
“ZNR” Transient/Surge Absorbers (Type D)
14 Series
■ Ratings and Characteristics
● Operating Temperature Range : –40 to 85 °C
● Storage Temperature Range : –40 to 125 °C
Maximum
Allowable
Voltage
Clamping
Voltage
(max.)
✽
Ip
Rated
Power
(V)
(W)
Maximum
Peak Current Capacitance
(8/20 µs)
(max.)
(10/1000 µs) (2 ms) 1 time 2 times
Maximum
Energy
Part No.
Varistor
Voltage
ERZV14D180
18(16 to 20)
11
14
36
0.1
5.2
4.3 2000 1000
25000
ERZV14D220
22(20 to 24)
14
18
43
0.1
6.3
5.3 2000 1000
20000
V1 mA (V)
ACrms (V)
DC (V)
(J)
(J)
(A)
(A)
at 1 kHz (pF)
ERZV14D270
27(24 to 30)
17
22
53
0.1
7.8
6.5 2000 1000
16000
ERZV14D330
33(30 to 36)
20
26
65
0.1
9.5
7.9 2000 1000
12200
ERZV14D390
39(35 to 43)
25
31
77
0.1
11
9.4 2000 1000
7000
ERZV14D470
47(42 to 52)
30
38
93
0.1
14
ERZV14D560
56(50 to 62)
35
45
110
0.1
16
ERZV14D680
68(61 to 75)
40
56
135
0.1
20
11
2000 1000
6750
13
2000 1000
6500
16
2000 1000
5500
ERZV14D820
82(74 to 90)
50
65
135
0.6
28
20
6000 5000
3700
ERZV14D101
100(90 to 110)
60
85
165
0.6
35
25
6000 5000
3200
ERZV14D121
120(108 to 132)
75
100
200
0.6
42
30
6000 5000
2700
ERZV14D151
150(135 to 165)
95
125
250
0.6
53
37.5 6000 5000
2200
ERZV14D201
200(185 to 225)
130
170
340
0.6
70
50
6000 5000
770
ERZV14D221
220(198 to 242)
140
180
360
0.6
78
55
6000 5000
740
ERZV14D241
240(216 to 264)
150
200
395
0.6
84
60
6000 5000
700
ERZV14D271
270(247 to 303)
175
225
455
0.6
99
70
6000 5000
640
ERZV14D331
330(297 to 363)
210
270
545
0.6
115
80
6000 4500
580
ERZV14D361
360(324 to 396)
230
300
595
0.6
130
90
6000 4500
540
ERZV14D391
390(351 to 429)
250
320
650
0.6
140
100
6000 4500
500
ERZV14D431
430(387 to 473)
275
350
710
0.6
155
110
6000 4500
450
ERZV14D471
470(423 to 517)
300
385
775
0.6
175
125
6000 4500
400
ERZV14D511
510(459 to 561)
320
410
845
0.6
190
136
6000 4500
350
ERZV14D561
560(504 to 616)
350
450
930
0.6
190
136
5000 4500
340
ERZV14D621
620(558 to 682)
385
505
1025
0.6
190
136
5000 4500
330
ERZV14D681
680(612 to 748)
420
560
1120
0.6
190
136
5000 4500
320
ERZV14D751
750(675 to 825)
460
615
1240
0.6
210
150
5000 4500
310
ERZV14D821
820(738 to 902)
510
670
1355
0.6
235
165
5000 4500
280
ERZV14D911
910(819 to 1001)
550
745
1500
0.6
255
180
5000 4500
250
ERZV14D102 1000(900 to 1100)
625
825
1650
0.6
280
200
5000 4500
230
1100(990 to 1210)
680
895
1815
0.6
310
220
5000 4500
210
ERZV14D182CS 1800(1700 to 1980)
1000
1465
2970
0.6
510
360
5000 4500
120
ERZV14D112
✽Ip Measuring current of clamping voltage 180 to 680 : 10 A, 820 to 182 : 50 A
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately.
01 Aug. 2012
– 18 –
“ZNR” Transient/Surge Absorbers (Type D)
✽ Refer to page 24 to 26 about leads cut type and taping.
L±1.0
D
1.3
1.4
1.5
1.7
1.6
1.7
1.8
2.0
W
1.6
1.8
f 0.8
2.0
2.3
1.9
2.0
2.1
2.3
(ERZV14D182CS)
2.6
2.8
D
2.9
3.1
3.3
3.5
3.8
4.2
f 0.8
4.5
4.9
5.2
5.7
6.2
6.8
10.5(±2.0)
T
L
L
18.5
18.5
18.5
18.5
18.5
18.5
18.5
18.5
18.5
18.5
18.5
18.5
18.5
18.5
18.5
18.5
18.5
18.5
18.5
18.5
18.5
18.5
19.0
19.0
19.0
19.0
19.0
19.0
19.0
19.0
20.5
W
T
L
H max.
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
15.0✽
W
2
W±1.0
4.6
4.7
4.8
5.0
4.9
5.0
5.1
5.3
4.5
4.7
4.9
5.2
4.8
4.9
5.0
5.2
5.5
5.7
5.8
6.0
6.2
6.4
6.7
7.1
7.4
7.8
8.1
8.6
9.1
9.7
14.4
H
T max.
15.5
15.5
15.5
15.5
15.5
15.5
15.5
15.5
15.5
15.5
15.5
15.5
15.5
15.5
15.5
15.5
15.5
15.5
15.5
15.5
15.5
15.5
16.0
16.0
16.0
16.0
16.0
16.0
16.0
16.0
17.0
20.0 min.
D max.
H
Part No.
ERZV14D180
ERZV14D220
ERZV14D270
ERZV14D330
ERZV14D390
ERZV14D470
ERZV14D560
ERZV14D680
ERZV14D820
ERZV14D101
ERZV14D121
ERZV14D151
ERZV14D201
ERZV14D221
ERZV14D241
ERZV14D271
ERZV14D331
ERZV14D361
ERZV14D391
ERZV14D431
ERZV14D471
ERZV14D511
ERZV14D561
ERZV14D621
ERZV14D681
ERZV14D751
ERZV14D821
ERZV14D911
ERZV14D102
ERZV14D112
ERZV14D182CS
4.0 ±1.5
■ Dimensions in mm (not to scale)
L
✽: W2
■ Typical Characteristics
Voltage vs. Current
Impulse Derating (Relation between impulse
width and impulse current multiple)
ERZV14D180 to ERZV14D680
10000
.BY$MBNQJOH7PMUBHF
.BY
-FBLBHF$VSSFOU
300
560
470
200
390
330
Voltage (V)
1000
270
220
470
100
90
80
70
60
50
2 times : 5 min. interval
up to 10 times : 2 min. interval
up to 106 times : 10 sec. interval
680
Impulse Current (A)
400
ERZV14D180 to ERZV14D680
180
0
68
0
6
5
40
10 2
100
1
Tim
e
Tim
10 3 es
10
T
e
i
10 4 me
Tim s
Tim s
es
10 5 es
Tim
es
10 6
Tim
es
Tim
2
10
30
0
39
0
33 70
2
0
22
0
18
20
1
20
10
9
8
7
6
5
100
1000
Impulse Width (µs)
10000
Test current waveform
10–6 to 10–3 A: Direct current
10–1 to 104 A: 8/20 µs
4
3
10–6
10–5
10–4
10–3
10–2
10–1
100
Current (A)
101
102
103
104
105
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately.
01 Aug. 2012
– 19 –
“ZNR” Transient/Surge Absorbers (Type D)
■ Typical Characteristics
Impulse Derating (Relation between impulse
Voltage vs. Current
width and impulse current multiple)
ERZV14D820 to ERZV14D511
ERZV14D820 to ERZV14D511
10000
10
100
90
80
70
60
50
40
30
10-6
271
241
1
20
121
101
10000
2 times : 5 min. interval
up to 10 times : 2 min. interval
up to 106 times : 10 sec. interval
Test Current Waveform
10-6 to 10-3 A: Direct Current
10-1 to 104 A: 8/20 µs
331
221
10-4
10-3
10-2
10-1
100
Current (A)
101
102
103
104
1000
105
5000
3000
10000
ERZV14D561 to ERZV14D112
820
10-5
1000
Impulse Width (µs)
ERZV14D561 to ERZV14D182CS
4000
100
201
151
Surge Current (A)
Voltage (V)
10
10 2 Tim
e
Tim s
es
300
200
1
2 Tim
T
10 3
10 ime e
s
T
10 4 Time 10 2 ime
Tim s
10 5 Tim s
es
T es
100
10 6 imes
Tim
es
10
.BY$MBNQJOH7PMUBHF
.BY
-FBLBHF$VSSFOU
182CS
102
911
821
1
20
112
102
911
821
751
681
621
561
2000
CS
182
100
1000
10000
Impulse Width (µs)
ERZV14D182CS
10000
2 times : 5 min. interval
up to 10 times : 2 min. interval
up to 106 times : 10 sec. interval
1000
2
11
Surge Current (A)
500
400
1
56
Ti
m
es
T
i
10 3 10 2 m
es
T
T
100 10 4 ime im
es
s
10 5 Time
Tim s
10 6
e
Tim s
es
e
600
m
2
700
Ti
1000
900
800
1
Voltage (V)
e
m
Ti es
m
101
820
511
10 3
T
10 4 ime
Tim s
10 5
e
Tim s
100
10 6 es
Tim
es
Ti
151
121
500
400
1000
2
471
431
391
361
1
1000
900
800
700
600
2 times : 5 min. interval
up to 10 times : 2 min. interval
up to 106 times : 10 sec. interval
511
471
431
391
361
331
271
241
221
201
Surge Current (A)
2000
.BY$MBNQJOH7PMUBHF
.BY
-FBLBHF$VSSFOU
10
10
300
200
10-6
Test Current Waveform
10-6 to 10-3 A: Direct Current
10-1 to 104 A: 8/20 µs
751
681
621
10-5
10-4
10-3
10-2
10-1
100
Current (A)
101
102
103
104
105
1
20
100
1000
10000
Impulse Width (µs)
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately.
01 Aug. 2012
– 20 –
“ZNR” Transient/Surge Absorbers (Type D)
20 Series
■ Ratings and Characteristics
● Operating Temperature Range : –40 to 85 °C
● Storage Temperature Range : –40 to 125 °C
Maximum
Allowable
Voltage
Clamping
Voltage
(max.)
✽
Ip
Rated
Power
(V)
(W)
Maximum
Peak Current Capacitance
(8/20 µs)
(max.)
(10/1000 µs) (2 ms) 1 time 2 times
Maximum
Energy
Part No.
Varistor
Voltage
ERZV20D180
18(16 to 20)
11
14
36
0.2
13
12
3000 2000
40000
ERZV20D220
22(20 to 24)
14
18
43
0.2
16
14
3000 2000
30000
V1 mA (V)
ACrms (V)
DC (V)
(J)
(J)
(A)
(A)
at 1 kHz (pF)
ERZV20D270
27(24 to 30)
17
22
53
0.2
19
17
3000 2000
24500
ERZV20D330
33(30 to 36)
20
26
65
0.2
24
21
3000 2000
20000
ERZV20D390
39(35 to 43)
25
31
77
0.2
28
25
3000 2000
13800
ERZV20D470
47(42 to 52)
30
38
93
0.2
34
30
3000 2000
13500
ERZV20D560
56(50 to 62)
35
45
110
0.2
41
36
3000 2000
12200
ERZV20D680
68(61 to 75)
40
56
135
0.2
49
44
3000 2000
11500
ERZV20D820
82(74 to 90)
50
65
135
1.0
56
40
10000 7000
7500
ERZV20D101
100(90 to 110)
60
85
165
1.0
70
50
10000 7000
6500
ERZV20D121
120(108 to 132)
75
100
200
1.0
85
60
10000 7000
5500
ERZV20D151
150(135 to 165)
95
125
250
1.0
106
75
10000 7000
4500
ERZV20D201
200(185 to 225)
130
170
340
1.0
140
100
10000 7000
1700
ERZV20D221
220(198 to 242)
140
180
360
1.0
155
110
10000 7000
1600
ERZV20D241
240(216 to 264)
150
200
395
1.0
168
120
10000 7000
1500
ERZV20D271
270(247 to 303)
175
225
455
1.0
190
135
10000 7000
1300
ERZV20D331
330(297 to 363)
210
270
545
1.0
228
160
10000 6500
1100
ERZV20D361
360(324 to 396)
230
300
595
1.0
255
180
10000 6500
1100
ERZV20D391
390(351 to 429)
250
320
650
1.0
275
195
10000 6500
1100
ERZV20D431
430(387 to 473)
275
350
710
1.0
303
215
10000 6500
1000
ERZV20D471
470(423 to 517)
300
385
775
1.0
350
250
10000 6500
900
ERZV20D511
510(459 to 561)
320
410
845
1.0
382
273
10000 6500
800
ERZV20D561
560(504 to 616)
350
450
930
1.0
382
273
7500 6500
750
ERZV20D621
620(558 to 682)
385
505
1025
1.0
382
273
7500 6500
700
ERZV20D681
680(612 to 748)
420
560
1120
1.0
382
273
7500 6500
650
ERZV20D751
750(675 to 825)
460
615
1240
1.0
420
300
7500 6500
600
ERZV20D821
820(738 to 902)
510
670
1355
1.0
460
325
7500 6500
530
ERZV20D911
910(819 to 1001)
550
745
1500
1.0
510
360
7500 6500
500
ERZV20D102 1000(900 to 1100)
625
825
1650
1.0
565
400
7500 6500
450
ERZV20D112 1100(990 to 1210)
680
895
1815
1.0
620
440
7500 6500
400
ERZV20D182 1800(1700 to 1980)
1000
1465
2970
1.0
1020
720
7500 6500
250
✽Ip Measuring current of clamping voltage 180 to 680 : 20 A, 820 to 182 : 100 A
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately.
01 Aug. 2012
– 21 –
“ZNR” Transient/Surge Absorbers (Type D)
✽ Refer to page 24 to 26A about leads cut type and taping.
ERZV20D180
ERZV20D220
ERZV20D270
ERZV20D330
ERZV20D390
ERZV20D470
ERZV20D560
ERZV20D680
ERZV20D820
ERZV20D101
ERZV20D121
ERZV20D151
ERZV20D201
ERZV20D221
ERZV20D241
ERZV20D271
ERZV20D331
ERZV20D361
ERZV20D391
ERZV20D431
ERZV20D471
ERZV20D511
ERZV20D561
ERZV20D621
ERZV20D681
ERZV20D751
ERZV20D821
ERZV20D911
ERZV20D102
ERZV20D112
ERZV20D182
21.5
21.5
21.5
21.5
21.5
21.5
21.5
21.5
21.5
21.5
21.5
21.5
21.5
21.5
21.5
21.5
21.5
21.5
21.5
21.5
21.5
21.5
22.5
22.5
22.5
22.5
22.5
22.5
22.5
22.5
23.5
5.1
5.2
5.3
5.5
5.5
5.6
5.7
5.8
4.9
5.1
5.3
5.6
5.2
5.3
5.4
5.6
5.9
6.1
6.2
6.4
6.6
6.8
7.1
7.5
7.8
8.2
8.5
9.0
9.5
10.1
14.8
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
15.0✽
24.5
24.5
24.5
24.5
24.5
24.5
24.5
24.5
24.5
24.5
24.5
24.5
24.5
24.5
24.5
24.5
24.5
24.5
24.5
24.5
24.5
24.5
25.5
25.5
25.5
25.5
25.5
25.5
25.5
25.5
28.0
D
L±1.0
1.5
1.6
1.7
1.9
1.9
2.0
2.1
2.2
W
1.8
2.0
f 1.0
2.2
2.5
2.1
2.2
(ERZV20D182)
2.3
2.5
D
2.8
3.0
3.1
3.3
3.5
3.7
4.2
4.4
4.7
5.1
f 1.0
5.4
5.9
6.4
7.0
10.7(±2.0)
T
L
L
H max.
W
T
W2
L
W±1.0
H
T max.
20.0 min.
D max.
H
Part No.
L
20.0 min.
■ Dimensions in mm (not to scale)
✽: W2
■ Typical Characteristics
Voltage vs. Current
Impulse Derating (Relation between impulse
width and impulse current multiple)
ERZV20D180 to ERZV20D680
10000
.BY$MBNQJOH7PMUBHF
.BY
-FBLBHF$VSSFOU
400
ERZV20D180 to ERZV20D680
2 times : 5 min. interval
up to 10 times : 2 min. interval
6
up to 10 times : 10 sec. interval
680
560
470
390
330
300
200
1000
220
100
90
80
70
60
50
Voltage (V)
Impulse Current (A)
270
180
0
68
0
6
5 70
4
0
39
0
3
3 0
27
40
30
20
10
0
22
0
18
10
9
8
7
6
100
1T
im
e
2
T
10 ime
Tim s
10 2 es
10 3 Time
Ti s
10 4 mes
Tim
es
10 5
Tim
es
10 6
Time
s
1
20
100
1000
Impulse Width (µs)
10000
Test current waveform
10–6 to 10–3 A: Direct current
10–1 to 104 A: 8/20 µs
5
4
3
10–6
10–5
10–4
10–3
10–2
10–1
100
101
102
103
104
105
Current (A)
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately.
01 Aug. 2012
– 22 –
“ZNR” Transient/Surge Absorbers (Type D)
■ Typical Characteristics
Impulse Derating (Relation between impulse
Voltage vs. Current
width and impulse current multiple)
ERZV20D820 to ERZV20D511
ERZV20D820 to ERZV20D511
10000
Voltage (V)
Surge Current (A)
151
400
100
121
511
10
101
820
300
271
200
1
20
100
1000
ERZV20D561 to ERZV20D112
10000
2 times : 5 min. interval
up to 10 times : 2 min. interval
6
up to 10 times : 10 sec. interval
820
10
10
-2
-1
0
10
10
Current (A)
10
1
2
10
3
10
4
5
2
T
10 ime
10 Tim s
2
10 3 Tim es
10 4 Tim es
10 5 Tim es
e
10 6 Time s
Tim s
es
10
10
100
e
10
-3
m
-4
Ti
10
-5
1000
1
Test Current Waveform
10-6 to 10-3 A: Direct Current
10-1 to 104 A: 8/20 µs
241
331
221
40
10000
Impulse Width (µs)
201
151
121
101
100
90
80
70
60
50
30
10-6
e
271
241
221
201
500
2
1 Tim
10 0 Ti es
2
m
10 3 Tim es
es
T
i
10 4
me
10 5 Tim s
Tim es
10 6
e
Tim s
es
m
1000
900
800
700
600
1000
Ti
471
431
391
361
1
511
471
431
391
361
331
Surge Current (A)
2000
2 times : 5 min. interval
up to 10 times : 2 min. interval
up to 106 times : 10 sec. interval
.BY$MBNQJOH7PMUBHF
.BY
-FBLBHF$VSSFOU
ERZV20D561 to ERZV20D182
10
5000
4000
3000
.BY$MBNQJOH7PMUBHF
.BY
-FBLBHF$VSSFOU
182
1
20
112
102
911
821
751
681
621
561
102
911
821
2000
10000
Surge Current (A)
500
1
56
e
600
Ti
m
Tim es
2
e
10 3 Tim s
e
s
10 4 Tim
e
100
10 5 Time s
Tim s
es
10 6
Tim
es
10
10
m
1
Ti
2
1000
1
Voltage (V)
2 times : 5 min. interval
up to 10 times : 2 min. interval
up to 106 times : 10 sec. interval
12
400
10000
ERZV20D182
1
700
1000
Impulse Width (µs)
82
1000
900
800
100
10
300
200
10-6
Test Current Waveform
10-6 to 10-3 A: Direct Current
4
10-1 to 10 A: 8/20 µs
751
681
621
10-5
10-4
10-3
10-2
10-1
100
Current (A)
101
102
103
104
105
1
20
100
1000
10000
Impulse Width (µs)
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately.
01 Aug. 2012
– 23 –