MG200MRRI4 Medical Approved Compact MiniDIP, 2W DC/DC Converters Key Features: Electrical Specifications • EN 60601 3RD Ed. Approved Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Input • 2W Output Power Parameter Conditions Min. Typ. Max. Units • 4.0 kVrms Isolation • Reinforced Insulation Input Voltage Range • 1 x MOPP & 2 x MOOP per Input Filter EN 60601-1 3RD Edition & Output Parameter ANSI/AAMI ES 60601-1 Output Voltage Accuracy • 2 µA Leakage Current Max Output Voltage Balance • Compact MiniDIP Case Line Regulation • Single & Dual Outputs Load Regulation, See Note 2 Ripple & Noise (20 MHz) • 2.0 MH MTBF Temperature Coefficient Output Short Circuit 5 VDC Input 4.5 5.0 12 VDC Input 10.8 12.0 24 VDC Input 21.6 24.0 Internal Capacitor Conditions Typ. ±2.0 Dual Outputs, Balanced Loads ±0.1 VIN = Min to Max ±1.2 See Model Selection Guide See Note 3 100 ±0.01 0.5 Sec. Max (Autorecovery) 5.5 13.2 26.4 VDC Max. ±4.0 ±1.0 ±1.5 Units % % % 150 ±0.02 mV P - P %/°C Max. Units Vrms 2.0 µA G⍀ pF kHz Min. General Parameter Isolation Voltage, Rated Reinforced Insulation Working Voltage Leakage Current Isolation Resistance Isolation Capacitance Switching Frequency Conditions Min. 60 Seconds 4,000 300 Vrms 500 VDC 100 kHz, 1V Typ. 10 50 15 80 20 100 EMI Characteristics Parameter EMC EMS Standard Criteria Complies With EN 55011 4TH Edition Complies With EN 60601-1-2 Level Environmental Parameter Conditions Ambient Case Operating Temperature Range Storage Temperature Range Cooling Humidity Physical Case Size Case Material Weight MicroPower Direct Reliability Specifications 292 Page Street Suite D Stoughton, MA 02072 USA Parameter MTBF T: (781) 344-8226 F: (781) 344-8481 E: [email protected] W: www.micropowerdirect.com Min. -25 Typ. -50 Free Air Convection RH, Non-condensing Max. +80 +105 +125 Units °C °C °C 95 % See Mechanical Diagram (Page 2) Non-Conductive Black Plastic (UL94-V0) 0.18 Oz (5.1g) Conditions Min. Typ. Max. Units MIL HDBK 217F, 25°C, Gnd Benign 2.0 MHours IEC/EN 60601-1, EN 60601-1 3RD Edition, 1xMOPP & 2xMOPP ANSI/AAMI ES 60601-1 1xMOPP & 2xMOPP Recognition (UL Certificate) ANSI/AAMI ES 60601-1, CAN/CSA-C22.2 No.60601-1 Safety Standards Absolute Maximum Ratings Parameter Conditions Input Voltage Surge (1 Sec) Lead Temperature Min. Typ. 5 VDC Input 12 VDC Input 24 VDC Input 1.5 mm From Case For 10 Sec Max. 9.0 18.0 30.0 260 Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings. www.micropowerdirect.com Units VDC °C www.micropowerdirect.com Model Selection Guide Model Number MG205SMR-05RI4 MG205SMR-12RI4 MG205SMR-15RI4 MG205DMR-12RI4 MG205DMR-15RI4 MG212SMR-05RI4 MG212SMR-12RI4 MG212SMR-15RI4 MG212DMR-12RI4 MG212DMR-15RI4 MG224SMR-05RI4 MG224SMR-12RI4 MG224SMR-15RI4 MG224DMR-12RI4 MG224DMR-15RI4 Input Output Current Voltage (VDC) Current (mA) Voltage (mA, Max) Nominal Range Full-Load No-Load (VDC) 5 4.5 - 5.5 606 60 5.0 400.0 5 4.5 - 5.5 600 60 12.0 165.0 5 4.5 - 5.5 605 60 15.0 133.0 5 4.5 - 5.5 553 60 ±12.0 ±83.0 5 4.5 - 5.5 542 60 ±15.0 ±66.0 12 10.8 - 13.2 253 30 5.0 400.0 12 10.8 - 13.2 250 30 12.0 165.0 12 10.8 - 13.2 252 30 15.0 133.0 12 10.8 - 13.2 224 30 ±12.0 ±83.0 12 10.8 - 13.2 220 30 ±15.0 ±66.0 24 21.6 - 26.4 126 15 5.0 400.0 24 21.6 - 26.4 125 15 12.0 165.0 24 21.6 - 26.4 126 15 15.0 133.0 24 21.6 - 26.4 112 15 ±12.0 ±83.0 24 21.6 - 26.4 110 15 ±15.0 ±66.0 Notes: 1. The specified maximum capacitive load is for each output. 2. Load regulation is measured for a load change of 20% to 100%. 3. When measuring output ripple, it is recommended that an external 0.47 µF ceramic capacitor be placed from the +VOUT pin to the -VOUT pin for single output units and from each output to common for dual output units. For noise sensitive applications, the use of 3.3 µF capacitors will reduce the output ripple. 4. Operation at no-load will not damage these units. However, they may not meet all specifications. 5. For dual output units, the maximum capacitive load is given for each output. 6. The converter should be connected to a low ac-impedance source. An input source with a highly inductive impedance may affect the stability of the converter. In applications where the converter output loading is high and input power is supplied over long lines, it may be necessary to use a capacitor on the input to insure start-up. In this case, it is recommended that a low ESR (ESR <1.0 at 100 kHz) capacitor be mounted close to the converter. For 5V input units a 2.2 µF is recommended, for 12V input units, a 1.0 µF; and for 24V units a 0.47 µF. 7. It is recommended that a fuse be used on the input of a power supply for protection. See the table above for the correct rating. Current (mA, Min) Capacitive Load Rating Efficiency Fuse Slow-Blow Load Regulation (%, Typ) (mA) 8.0 3.0 2.5 ±1.5 ±1.0 8.0 3.0 2.5 ±1.5 ±1.0 8.0 3.0 2.5 ±1.5 ±1.0 (µF, Max) (%, Max) 330 330 330 100 100 330 330 330 100 100 330 330 330 100 100 12 10 10 10 10 12 10 10 10 10 12 10 10 10 10 66 66 66 72 73 66 66 66 74 75 66 66 66 74 75 1,200 1,200 1,200 1,200 1,200 500 500 500 500 500 250 250 250 250 250 Derating Curve Mechanical Dimensions Pin Co Connections Pin Single Dual 1 -Vin -Vin 7 NC NC 8 NC Common 9 +Vout +Vout 10 -Vout -Vout 16 +Vin +Vin NC = No Co Connection MicroPower Direct We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • Mechanical Notes: • All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.01 (±0.25) FAX: (781) 344-8481 • E-Mail: [email protected]