Rohm BP5725 Isolated ac/dc converter Datasheet

BP5725
Isolated AC/DC Converter
AC 100 to AC230V input, 6W output
Absolute Maximum Ratings
Dimensions (mm)
Unit
V
Vpeak
mA
W
Tcmax
105
°C
Topr
−25 to +80
°C
−25 to +105
Tstg
Conditions
7.8MAX.
22.5MAX.
MARKING SIDE
Limits
800
45
400
6
24.0MAX.
Symbol
VD
VG
ID
Po
Ambient temperature + module
self-heating
Tcmax
4.0±1.0
Parameter
7-pin input voltage
4-pin input voltage
7-pin input Current
Maximum power
Allowable maximum
surface temperature
Operating
temperature range
Storage temperature
range
1 2 3 4 5
7
0.25±0.05
5.55MAX.
P=2.54±0.2
2.54X6=15.24TYP.
°C
Electrical Characteristics
Line regulation
Load regulation
Output ripple voltage
Power conversion
efficiency
Derating Curve
(Unless otherwise noted, Vi=311V, rated load Ta=25°C)
Parameter
Symbol
Output detection voltage Vod
Output current
Io
Min.
−7.1
10
Typ.
−7.6
−
Max.
−8.1
500
Unit
V
mA
Vr
VI
Vp
−
−
−
380
90
300
500
200
500
mV
mV
mVp-p
η
70
77
−
%
Conditions
Io=500mA
Refer to derating curve
Vi=119V to 405VDC
Io=500mA
Io=200mA to 500mA
∗1
7
6
Output Power (W)
<In case of 12V output>
5
4
Operation Range
3
2
1
0
-30-20-10 0 10 20 30 40 50 60 70 80 90
Ambient Temperature Ta(°C)
∗1: Pulse noise is not included.
Vin+
FUSE
ZNR
Pin
No.
Name
1
Vod
This is the output
detection terminal.
2
Vod
This is the output
detection terminal.
3
Vin(-)
This is the primary side
input minus terminal.
4
VG
MOSFET, GATE driving
input terminal.
5
Vs
This is the start terminal.
Connect this via the external
resistor (720kΩ) to Vi (+).
6
NC
7
VD
FL1
C6
D3
T1
R2
R1
C2
D1
D2
C1
+
Vi n -
Vo
+
R3
C3
+
C4
1 2 3 45 7
BP5725
External Component Settings
C5
R4
GND
Function
This is the NC pin.
This is the built-in FET of
drain terminal. The primary
coil minus side of the external
transformer, and the snubber
circuit for noise reduction are
connected to this.
Be sure to evaluate it under the condition that it
C1: Capacitor for input voltage smoothing 10µF/450V
is mounted by your product. Especially, confirm
C2: For noise terminal voltage reduction
2200pF/1kV
whether output power never exceeds a
maximum standard with current probe.
C3: Capacitor for Vod voltage smoothing 10µF/50V
C4: Capacitor for output voltage smoothing 1000µF/25V
C5: For noise terminal voltage reduction
2200pF/AC250V
C6: Noise terminal voltage
Please set it, if necessary
countermeasure capacitor
Limiting element voltage DC630V or higher 0.1 to 0.22µF
D1: Rectifier diode
FRD 800V/0.5A
D2: Rectifier diode
FRD 200V/1A
D3: Diode bridge
800V/1A
R1, R3: Resistor
360kΩ±5% 0.25W
R2: Resistor
200kΩ±5% 1W
R4: Bleeder resistor
In case Io is less than 10mA, connect a bleeder resistance in parallel to C4.
T1: Switching transformer
FL1: For noise terminal voltage reduction
Please set it, if necessary
FUSE: Fuse
Be sure to use this for safety.
ZNR: Varistor
Must be use. It protects this part from lightning surge and static electricity.
Precautions on use of products
When the capacity of the output smoothing electrolytic capacitor C1 is made large, output may not rise.
100µF to 2200µF is recommended. Set the rise time within 10ms.
Set the Vod electrolytic capacitor C3 to 10µF.
Be sure to use the VG terminal voltage within the operating voltage range.
Set the external starting resistor (R1+R3) to 720KΩ. When reducing the resistance value, start-up may fail.
Take note of the loss of the resistor when it is reduced.
This product has built-in over current (reset type) protection function to prevent destruction at abrupt error.
These protection functions are effective for prevention against destruction owing to abrupt accident,
therefore, avoid using them for continuous protection circuit operating, or at transition
Conversion Efficiency
Conversion Efficiency η (%)
Be sure to use fuse for safety.
<In case of 12V output>
(Vin=311V, Ta=25°C)
100
80
60
40
20
0
0
50 100 150 100 250 300 350 400 450 500
Output Current Io(mA)
Load Regulation
<In case of 12V output>
(Vin=311V, Ta=25°C)
Output Voltage Vo(V)
Sample Application Circuit
18.0
16.0
14.0
12.0
10.0
8.0
6.0
4.0
2.0
0.0
Maximum Io=500mA
0
200
400
600
800
1000
Output Current Io(mA)
1200
Appendix
Notes
No technical content pages of this document may be reproduced in any form or transmitted by any
means without prior permission of ROHM CO.,LTD.
The contents described herein are subject to change without notice. The specifications for the
product described in this document are for reference only. Upon actual use, therefore, please request
that specifications to be separately delivered.
Application circuit diagrams and circuit constants contained herein are shown as examples of standard
use and operation. Please pay careful attention to the peripheral conditions when designing circuits
and deciding upon circuit constants in the set.
Any data, including, but not limited to application circuit diagrams information, described herein
are intended only as illustrations of such devices and not as the specifications for such devices. ROHM
CO.,LTD. disclaims any warranty that any use of such devices shall be free from infringement of any
third party's intellectual property rights or other proprietary rights, and further, assumes no liability of
whatsoever nature in the event of any such infringement, or arising from or connected with or related
to the use of such devices.
Upon the sale of any such devices, other than for buyer's right to use such devices itself, resell or
otherwise dispose of the same, no express or implied right or license to practice or commercially
exploit any intellectual property rights or other proprietary rights owned or controlled by
ROHM CO., LTD. is granted to any such buyer.
Products listed in this document are no antiradiation design.
The products listed in this document are designed to be used with ordinary electronic equipment or devices
(such as audio visual equipment, office-automation equipment, communications devices, electrical
appliances and electronic toys).
Should you intend to use these products with equipment or devices which require an extremely high level
of reliability and the malfunction of which would directly endanger human life (such as medical
instruments, transportation equipment, aerospace machinery, nuclear-reactor controllers, fuel controllers
and other safety devices), please be sure to consult with our sales representative in advance.
It is our top priority to supply products with the utmost quality and reliability. However, there is always a chance
of failure due to unexpected factors. Therefore, please take into account the derating characteristics and allow
for sufficient safety features, such as extra margin, anti-flammability, and fail-safe measures when designing in
order to prevent possible accidents that may result in bodily harm or fire caused by component failure. ROHM
cannot be held responsible for any damages arising from the use of the products under conditions out of the
range of the specifications or due to non-compliance with the NOTES specified in this catalog.
Thank you for your accessing to ROHM product informations.
More detail product informations and catalogs are available, please contact your nearest sales office.
ROHM Customer Support System
www.rohm.com
Copyright © 2007 ROHM CO.,LTD.
THE AMERICAS / EUPOPE / ASIA / JAPAN
Contact us : webmaster@ rohm.co. jp
21, Saiin Mizosaki-cho, Ukyo-ku, Kyoto 615-8585, Japan
TEL : +81-75-311-2121
FAX : +81-75-315-0172
Appendix1-Rev2.0