AKM45 Series AC-DC Power Supplies 45 Watt xxx Series • Energy Efficiency Level VI • European CoC Tier 2 • Medical and ITE Approvals • Optional Class II Versions • Optional White Versions • Output Voltages from 9 V to 48 V • Optional AC Cable Restraint • 3 Years Warranty The AKM45 series of desktop adaptors comply with the latest energy efficiency level VI standards with high active mode efficiency and extremely low no load power consumption. Available with a standard jack plug connector these adaptors suit a wide variety of cost sensitive industrial and medical applications while maintaining industry leading performance. Dimensions: AKM: 4.82 x 2.02 x 1.24” (122.4 x 51.4 x 31.5 mm) Models & Ratings Output Power 48 W Output Voltage Output Current Total Regulation(1) Efficiency(2) Model Number(3,4) AKM45US09 9.0 V 4.50 A 5% 89.8% 12.0 V 4.00 A 5% 90.5% AKM45US12 15.0 V 3.20 A 5% 90.5% AKM45US15 18.0 V 2.66 A 5% 90.6% AKM45US18 24.0 V 2.00 A 5% 90.2% AKM45US24 48.0 V 1.00 A 5% 91.2% AKM45US48 Notes 1. Total regulation includes initial set accuracy, line and load regulation. 2. Typical average value measured at 25%, 50%, 75% and 100% at 230 VAC. 3. For white case version add suffix ‘-W’ e.g. AKM45US12-W. MOQ applies, contact sales for details. 4. For optional Class II version add suffix C2, e.g. AKM45US24C2. Input Characteristic Input Voltage Input Frequency Input Current Inrush Current No Load Input Power Input Protection Minimum 90 47 Typical Maximum 264 63 1.3 100 75 Units VAC Hz A A mW Maximum 48 5 Units V A s ms ms % 4 % deviation 200 mV pk-pk 160 % 0.05 %/ ˚C Notes & Conditions 90 VAC 230 VAC, cold start at 25 °C Internal fuse in both line and neutral Output Characteristic Output Voltage Minimum Load Start Up Delay Start Up Rise Time Hold Up Time Total Regulation Minimum 9 0 30 Ripple & Noise 1 4 55 10 Transient Response Overload Protection Short Circuit Protection Temperature Coefficient Typical 130 Notes & Conditions See Models and Ratings table No minimum load required Full load and 100 VAC See Models and Ratings table Recovery within <1% within 500 µs for a 60% step load change at 0.15 A/µs Measured with 20 MHz bandwidth and 10 µF electrolytic in parallel with 0.1 µF ceramic capacitor Continuous, trip and restart (hiccup mode) with auto recovery www.xppower.com AKM45 Series AC-DC Power Supplies General Characteristic Minimum Typical Efficiency Maximum Notes & Conditions Units Typical average of efficiencies measured at 25%, 50%, 75% and 100% load and 115 VAC input % 89 Energy Efficiency Level VI 4000 Isolation Leakage Current 24 Mean Time Between Failure 250 70 0.75 (340) Weight Input to Output, 2 x MOPP kHz kHrs 264 VAC, 60 Hz µA 100 Switching Frequency VAC Variable MIL-HDBK-217F at 25 °C GB lb (g) Environmental Characteristic Minimum Maximum Units 0 +60 °C Storage Temperature -25 +70 °C Operating Humidity 5 90 % 5000 m Operating Temperature Typical Operating Altitude Notes & Conditions Derate from 100% load at 40 °C to 50% load at 60 °C. Agency approval to 40 °C max. RH, non-condensing Natural convection Cooling 1 m drop onto concrete on each of 6 axes, non operating Shock 10 Vibration Hz 300 2 g, 0.3 decades/min, 15 mins for each of 3 axes EMC: Emissions Phenomenon Standard Test Level Conducted EN55032 Level B EN55032 Level B Radiated Voltage Flicker Notes & Conditions EN61000-3-3 EMC: Immunity Phenomenon Medical Device EMC Low Voltage PSU EMC Standard Test Level Criteria IEC60601-1-2 Ed.4.0 : 2014 as below as below EN61204-3 High severity level ESD Immunity EN61000-4-2 ±8 kV contact, ±15 kV air A Radiated Immunity EN61000-4-3 10 V/m A EFT/Burst EN61000-4-4 Level 3 A Surge EN61000-4-5 Installation Class 3 A Conducted Immunity EN61000-4-6 6V A Magnetic Fields EN61000-4-8 30 A/m Int: 100% 10 ms Dip: 30% 500 ms A A A Int: 100% 5000 ms B Dip: 30% 25 AC Cycles A EN61000-4-11 Dips and Interruptions EN60601-1-2 Int: 100% 0.5 AC Cycle A Int: 100% 1 AC Cycle B Int.: >95% 5000 ms B Notes & Conditions At 8 angles Safety Approvals Safety Agency UL Safety Standard Notes & Conditions UL60950-1 TUV EN60950-1 CB IEC60950-1 CE LVD UL ANSI/AAMI ES 60601-1 CSA CSA C22.2 No. 60601 TUV EN60601-1 CB IEC60601-1 Information Technology Medical, 2 x MOPP www.xppower.com 2 AKM45 Series AC-DC Power Supplies Mechanical Details AKM45USXX 3.14 (80.0) 1.18 (30.0) Standard Class I inlet IEC320-C14 Standard Class II inlet polarised IEC320-C8 S 1.24 (31.5) 39.3 (1000.0) 0.43 (11.0) 1.25 (32.0) 2.02 (51.4) ø0.09 (ø2.5) 4.81 (122.4) ø0.21 (ø5.5) AKM45USXX with Optional AC Cable Restraint Optional AC Cable Restraint 1.09 (27.8) 0.37 (9.6) 0.53 (13.7) 0.52 (13.4) 0.07 (1.8) Optional AC Cable 80º 1.24 (31.5) Restraint 1.41 (36.0) Notes For optional AC cable restraint, order additional part AFM45-65 AC Clip. For correct restraint, AC mains lead must be Interpower Corporation, part number 70006020300. AC cable restraint is not suitable for use on Class II version. Output plug: ø5.5 x ø2.5 x 11.0mm, centre positive 3 www.xppower.com 19 June 18