XP Power AKM45US12 Ac-dc power supply Datasheet

AKM45 Series
AC-DC Power Supplies
45 Watt
xxx Series
• Energy Efficiency Level VI
• European CoC Tier 2
• Medical and ITE Approvals
• Optional Class II Versions
• Optional White Versions
• Output Voltages from 9 V to 48 V
• Optional AC Cable Restraint
• 3 Years Warranty
The AKM45 series of desktop adaptors comply with the latest energy efficiency level VI standards
with high active mode efficiency and extremely low no load power consumption. Available with a
standard jack plug connector these adaptors suit a wide variety of cost sensitive industrial and
medical applications while maintaining industry leading performance.
Dimensions:
AKM:
4.82 x 2.02 x 1.24” (122.4 x 51.4 x 31.5 mm)
Models & Ratings
Output Power
48 W
Output Voltage
Output Current
Total Regulation(1)
Efficiency(2)
Model Number(3,4)
AKM45US09
9.0 V
4.50 A
5%
89.8%
12.0 V
4.00 A
5%
90.5%
AKM45US12
15.0 V
3.20 A
5%
90.5%
AKM45US15
18.0 V
2.66 A
5%
90.6%
AKM45US18
24.0 V
2.00 A
5%
90.2%
AKM45US24
48.0 V
1.00 A
5%
91.2%
AKM45US48
Notes
1. Total regulation includes initial set accuracy, line and load regulation.
2. Typical average value measured at 25%, 50%, 75% and 100% at 230 VAC.
3. For white case version add suffix ‘-W’ e.g. AKM45US12-W. MOQ applies,
contact sales for details.
4. For optional Class II version add suffix C2, e.g. AKM45US24C2.
Input
Characteristic
Input Voltage
Input Frequency
Input Current
Inrush Current
No Load Input Power
Input Protection
Minimum
90
47
Typical
Maximum
264
63
1.3
100
75
Units
VAC
Hz
A
A
mW
Maximum
48
5
Units
V
A
s
ms
ms
%
4
% deviation
200
mV pk-pk
160
%
0.05
%/ ˚C
Notes & Conditions
90 VAC
230 VAC, cold start at 25 °C
Internal fuse in both line and neutral
Output
Characteristic
Output Voltage
Minimum Load
Start Up Delay
Start Up Rise Time
Hold Up Time
Total Regulation
Minimum
9
0
30
Ripple & Noise
1
4
55
10
Transient Response
Overload Protection
Short Circuit Protection
Temperature Coefficient
Typical
130
Notes & Conditions
See Models and Ratings table
No minimum load required
Full load and 100 VAC
See Models and Ratings table
Recovery within <1% within 500 µs for a 60% step load
change at 0.15 A/µs
Measured with 20 MHz bandwidth and 10 µF electrolytic in
parallel with 0.1 µF ceramic capacitor
Continuous, trip and restart (hiccup mode) with auto recovery
www.xppower.com
AKM45 Series
AC-DC Power Supplies
General
Characteristic
Minimum
Typical
Efficiency
Maximum
Notes & Conditions
Units
Typical average of efficiencies measured at 25%, 50%, 75%
and 100% load and 115 VAC input
%
89
Energy Efficiency
Level VI
4000
Isolation
Leakage Current
24
Mean Time Between Failure
250
70
0.75 (340)
Weight
Input to Output, 2 x MOPP
kHz
kHrs
264 VAC, 60 Hz
µA
100
Switching Frequency
VAC
Variable
MIL-HDBK-217F at 25 °C GB
lb (g)
Environmental
Characteristic
Minimum
Maximum
Units
0
+60
°C
Storage Temperature
-25
+70
°C
Operating Humidity
5
90
%
5000
m
Operating Temperature
Typical
Operating Altitude
Notes & Conditions
Derate from 100% load at 40 °C to 50% load at 60 °C.
Agency approval to 40 °C max.
RH, non-condensing
Natural convection
Cooling
1 m drop onto concrete on each of 6 axes, non operating
Shock
10
Vibration
Hz
300
2 g, 0.3 decades/min, 15 mins for each of 3 axes
EMC: Emissions
Phenomenon
Standard
Test Level
Conducted
EN55032
Level B
EN55032
Level B
Radiated
Voltage Flicker
Notes & Conditions
EN61000-3-3
EMC: Immunity
Phenomenon
Medical Device EMC
Low Voltage PSU EMC
Standard
Test Level
Criteria
IEC60601-1-2
Ed.4.0 : 2014
as below
as below
EN61204-3
High severity level
ESD Immunity
EN61000-4-2
±8 kV contact, ±15 kV air
A
Radiated Immunity
EN61000-4-3
10 V/m
A
EFT/Burst
EN61000-4-4
Level 3
A
Surge
EN61000-4-5
Installation Class 3
A
Conducted Immunity
EN61000-4-6
6V
A
Magnetic Fields
EN61000-4-8
30 A/m
Int: 100% 10 ms
Dip: 30% 500 ms
A
A
A
Int: 100% 5000 ms
B
Dip: 30% 25 AC Cycles
A
EN61000-4-11
Dips and Interruptions
EN60601-1-2
Int: 100% 0.5 AC Cycle
A
Int: 100% 1 AC Cycle
B
Int.: >95% 5000 ms
B
Notes & Conditions
At 8 angles
Safety Approvals
Safety Agency
UL
Safety Standard
Notes & Conditions
UL60950-1
TUV
EN60950-1
CB
IEC60950-1
CE
LVD
UL
ANSI/AAMI ES 60601-1
CSA
CSA C22.2 No. 60601
TUV
EN60601-1
CB
IEC60601-1
Information Technology
Medical, 2 x MOPP
www.xppower.com
2
AKM45 Series
AC-DC Power Supplies
Mechanical Details
AKM45USXX
3.14 (80.0)
1.18
(30.0)
Standard Class I
inlet IEC320-C14
Standard Class II inlet
polarised IEC320-C8
S
1.24
(31.5)
39.3 (1000.0)
0.43 (11.0)
1.25
(32.0)
2.02
(51.4)
ø0.09 (ø2.5)
4.81 (122.4)
ø0.21 (ø5.5)
AKM45USXX with Optional AC Cable Restraint
Optional AC Cable Restraint
1.09
(27.8)
0.37
(9.6)
0.53
(13.7)
0.52
(13.4)
0.07
(1.8)
Optional
AC Cable
80º
1.24
(31.5)
Restraint
1.41
(36.0)
Notes
For optional AC cable restraint, order additional part AFM45-65 AC Clip.
For correct restraint, AC mains lead must be Interpower Corporation, part number 70006020300.
AC cable restraint is not suitable for use on Class II version.
Output plug: ø5.5 x ø2.5 x 11.0mm, centre positive