Littelfuse GTCC23-301M-R01-2 Gas discharge tube Datasheet

Gas Discharge Tubes
GTCC23-XXXM-R01-2 Series
Littelfuse Circuit Protection 3mm 2Pole Chip type
GDTs (ceramic gas discharge tubes), are
commonly used to help protect sensitive telecom
equipment such as communication lines, signal
lines and data transmission lines from damage
caused by transient surge voltages that typically
result from lightning strikes and equipment
switching operations.
Littelfuse Circuit Protection 3mm Chip type GDTs
offer excellent surge protection characteristics, low
capacitance and a broad array of breakover
voltage levels, making them suitable for
applications such as high data-rate telecom
communication network protection (e.g. ADSL,
VDSL).
Benefits:
Features:
 Compact, small form factor suitable for efficient
assembly
 2Poles, 3mm devices
 Broad voltage range from 75V-400V
 Suitable for high-frequency applications
 Form factor: surface mount
 Low capacitance and insertion loss
 Referring to ITUT K.20 and ITUT K.21
 UL 497B recognized
 RoHS compliant
 Devices tested per ITU K.12 recommendations
 Non-radioactive materials
Applications:
 Telecommunications, RF system protection, CATV Modem, Hub protection, Security Systems, Data acquisition
© 2016 Littelfuse,Inc.
Specifications are subject to change without notice
Revised July 26,2016.
1
Document: SCD27776
Status:
RELEASED
Rev: G
Date: JULY 26, 2016
Gas Discharge Tubes
GTCC23-XXXM-R01-2 Series
Device Voltage Ratings
DC Sparkover
Impulse
Sparkover Voltage
@100V/s
±20% Tolerance
(V)
@1000 V/µs (V)
GTCC23-750M-R01-2*
75
600
GTCC23-900M-R01-2
90
600
GTCC23-141M-R01-2
140
600
GTCC23-151M-R01-2
150
600
GTCC23-201M-R01-2
200
700
GTCC23-231M-R01-2
230
700
GTCC23-301M-R01-2
300
900
GTCC23-351M-R01-2
350
1000
GTCC23-401M-R01-2
400
1000
GTCC23-421M-R01-2
420
1000
GTCC23-501M-R01-2
500
1200
Part Number
*DCSO 60~105
Part Marking : Not Applicable
Device Surge Rating, Capacitance, Insulation Resistance, UL
Listing
Part Number
GTCC23-xxxM-R01-2
Insulation
Resistance
Capacitance
Impulse Discharge Current
8/20µs
@100VDC*
@1Mhz
10 hits (5hits each
polarity)
≥ 1,000 (MΩ)
<0.5pF
1kA
Impulse Withstanding
Voltage 10/700µs
UL
Rating
300 hits (150hits
each polarity)
10 hits (5 times each
polarity)**
UL497B
#E179610
100A
4kV
All Devices
* Devices <=150V measured @ 50Vdc
** Effective output impedance: 40ohms
© 2016 Littelfuse,Inc.
Specifications are subject to change without notice
Revised July 26,2016.
2
Document: SCD27776
Status:
RELEASED
Rev: G
Date: JULY 26, 2016
Gas Discharge Tubes
GTCC23-XXXM-R01-2 Series
Product Dimensions
DIMENSIONS = MILLIMETERS [INCHES]
Surface-mount (GTCC23-XXXM-R01-2)
Pad Layout – Surface- mount Devices (GTCC23-XXXM-R01-2)
mm:
in*:
X
NOM
3.5
(0.138)
Y
NOM
2.7
(0.106)
Z1
NOM
2.0
(0.079)
Z2
NOM
2.0
(0.079)
*Rounded off approximation
General Characteristics
No Radioactive Material
Storage Temperature: -40ºC to +90ºC
Operating Temperature: -40ºC to +90ºC
Electrode: Tin Plated
m
Materials Information
ROHS Compliant
ELV Compliant
Pb-Free
Halogen Free*
HF
© 2016 Littelfuse,Inc.
Specifications are subject to change without notice
Revised July 26,2016.
3
Document: SCD27776
Status:
RELEASED
Rev: G
Date: JULY 26, 2016
Gas Discharge Tubes
GTCC23-XXXM-R01-2 Series
Packaging Information
Part Description
Reel
Surface-mount: GTCC23-XXXM-R01-2 2000pcs (Reel)
Standard Package
16,000pcs
Packaging Information
© 2016 Littelfuse,Inc.
Specifications are subject to change without notice
Revised July 26,2016.
4
Document: SCD27776
Status:
RELEASED
Rev: G
Date: JULY 26, 2016
Gas Discharge Tubes
GTCC23-XXXM-R01-2 Series
Part Numbering System
Example Part Number: GTCC23-351M-R01-2
GT =
C=
C=
2=
3=
351 =
M=
R=
01 =
-2 =
Gas Tube
Ceramic
Lead Configuration: C= Chip Type
2 Electrode device
3mm Diameter
DC Spark Over Voltage of 350V (at 100V/s)
Tolerance of 20% on DC Spark Over Voltage
Product Family Designator
Surge rating: 8x20µs 1kA 10 times
Tape and Reel Packaging
Littelfuse products are not designed for, and shall not be used for, any purpose (including, without limitation, automotive, military, aerospace, medical, life-saving, life-sustaining or
nuclear facility applications, devices intended for surgical implant into the body, or any other application in which the failure or lack of desired operation of the product may result in
personal injury, death, or property damage) other than those expressly set forth in applicable Littelfuse product documentation. Warranties granted by Littelfuse shall be deemed void for
products used for any purpose not expressly set forth in applicable Littelfuse documentation. Littelfuse shall not be liable for any claims or damages arising out of products used in
applications not expressly intended by Littelfuse as set forth in applicable Littelfuse documentation. The sale and use of Littelfuse products is subject to Littelfuse Terms and Conditions
of Sale, unless otherwise agreed by Littelfuse.
© 2016 Littelfuse,Inc.
Specifications are subject to change without notice
Revised July 26,2016.
5
Document: SCD27776
Status:
RELEASED
Rev: G
Date: JULY 26, 2016
Similar pages