AIMTEC AM6CW-11005S-NZ 6 watt | dc-dc converter Datasheet

Series AM6CW-NZ
6 Watt | DC-DC Converter
Picture coming soon
FEATURES:







Wide 4:1 Input Voltage Range
High efficiency up to 85%
1500 VDC Isolation
Low ripple & noise
Operating Temperature -40ºC to +85ºC
Output Over Voltage protection
Continuous Short Circuit Protection
Models
Single output
Model
Input
Voltage (V)
Output
Voltage
(V)
Output Current
max (mA)
Isolation
(VDC)
Max
Capacitive
Load(uF)
Efficiency
(%)
AM6CW-11005S-NZ
AM6CW-11012S-NZ
AM6CW-11015S-NZ
AM6CW-11024S-NZ
40-160
40-160
40-160
40-160
5
12
15
24
1200
500
400
250
1500
1500
1500
1500
1000
100
100
47
81
83
85
85
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Input Specifications
Parameters
Nominal
Typical
Voltage range
Filter
Absolute Maximum Rating (100ms)
No Load Input Current
Input reflected current
110
40-160
Pi
Maximum
Units
VDC
110
180
VDC
mA
mA
Maximum
Units
>1000
VDC
MOhm
pF
2
20
Isolation Specifications
Parameters
Tested I/O voltage
Resistance
Capacitance
Conditions
Typical
60 sec, <1mA
500VDC
1500
1000
Output Specifications
Parameters
Voltage accuracy
Over voltage protection
Short Circuit protection
Short circuit restart
Line voltage regulation
Load voltage regulation
Temperature coefficient
Ripple
Noise
Transient recovery time
Transient recovery deviation
Conditions
Typical
Maximum
±2
110-140
Continuous
Auto-Recovery
±0.5
±1
Full load, LL to HL
5% to 100% load
100% load
%
% of Vo
±0.03
25
100
25% load step change
25% load step change
Units
1
±5
% of Vin
%
%/oC
mV p-p
mV p-p
mS
%
General Specifications
Parameters
Switching frequency
Operating temperature
Storage temperature
Maximum case temperature
Cooling
www.aimtec.com
F 051e R13
Conditions
Typical
100% load
Derating above 71°C
300
Maximum
Units
100
KHz
oC
oC
oC
-40 to +85
-55 to +125
Free air convection
Tel: +1 514 620 2722
1 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM6CW-NZ
6 Watt | DC-DC Converter
General Specifications (continued)
Parameters
Conditions
Humidity
Case material
Weight
Dimensions (L x W x H)
MTBF
Maximum soldering temperature
Vibrations
Typical
Maximum
Units
95
% RH
Aluminum Alloy
14
1 x 1 x 0.46 inches
25.40 x 25.40 x 11.70 mm
o
>1,000,000 hours (MIL-HDBK -217F, Ground Benign, t=+25 C)
1.5mm from case for 10 sec
300
5-150Hz, Displacement: 7.5mm, Acceleration: 2g
g
oC
Safety Specifications
Parameters
Meets EN60950-1
EN 55022, class B (with the recommended EMC circuit)
Standards
Pin Out Specifications
Pin
1
2
3
4
Single
-Vin
+Vin
+Vout
-Vout
Dimensions
Bottom View
20.32
(0.80)
2.54
(0.10)
Top View
25.40
(1.00)
4
3
20.32
(0.80)
25.40
(1.00)
+V Output
-V Output
+V
-V
Input Input
2.54
(0.10)
1
Side View
10.16
(0.40)
2
5.08
(0.20)
Printed Face
9.90
(0.39)
Notes: All dimensions are typical in millimeters (inches).
Case Tolerance ±0.25 (±0.01)
Pin diameter tolerance ±0.1 (±0.004)
Pin height tolerance ±0.5 (±0.02)
2.54
(0.10)
www.aimtec.com
F 051e R13
1.00
(0.39)
Tel: +1 514 620 2722
2 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM6CW-NZ
6 Watt | DC-DC Converter
Derating
Free Air Convection
71º C
Output Power (%)
100
80
Safe Operating Area
60
40
20
0
- 40
- 20
0
20
40
60
80
85
100
Ambient Temperature º C
Recommended EMC Circuit
Y1
L1
10mH
1nF/2KV
L1
10mH
+Vo
+Vin
CX
0.68uF
CX
0.68uF
CX
0.68uF
AM6CW‐NZ
‐Vin
‐Vo
Y2
1nF/2KV
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 051e R13
Tel: +1 514 620 2722
3 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only