MSKW2000 SERIES DC/DC CONVERTER 5W, SMD-Package FEATURES ►Industrial SMD Package ►Wide 2:1 Input Voltage Range ►Fully Regulated Output Voltage ►I/O Isolation 1500 VDC ►Operating Ambient Temp. Range -40°C to +85°C ►Overload and Short Circuit Protection ►Remote On/Off Control ►Conducted EMI meets EN55022 Class A & FCC Level A ►Qualified for Lead-free Reflow Solder Process According to IPC/JEDEC J-STD-020D.1 ►Tape & Reel Package Available ►UL/cUL/IEC/EN 60950-1 Safety Approval PRODUCT OVERVIEW The MINMAX MSKW2000 series is a range of isolated 5W DC/DC converter modules featuring fully regulated output voltages and wide 2:1 input voltage ranges. These products are in a low profile SMD package with dimensions of 33.4 x 20.8 x 9.8 mm. All models are qualified for lead free reflow solder processes according IPC J-STD-020D.1. An excellent efficiency allows an operating temperature range of–40° to +85°C (with derating). Typical applications for these converters are battery operated equipment and instrumentation, communication and general industrial electronics. Model Selection Guide Model Number Input Voltage (Range) Output Voltage VDC VDC Output Current Input Current Max. Min. @Max. Load @No Load Reflected Ripple Current mA mA mA(typ.) mA(typ.) mA(typ.) MSKW2021 3.3 1200 120 434 MSKW2022 5 1000 100 521 MSKW2023 12 417 41.7 502 15 333 33.3 502 MSKW2024 MSKW2025 12 (9 ~ 18) Max. capacitive Load μF Efficiency (typ.) @Max. Load % 76 680 45 25 80 83 83 ±5 ±500 ±50 521 MSKW2026 ±12 ±208 ±20.8 501 MSKW2027 ±15 ±167 ±16.7 503 MSKW2031 3.3 1200 120 212 78 MSKW2032 5 1000 100 254 82 12 417 41.7 245 MSKW2033 MSKW2034 24 (18 ~ 36) 80 100# 83 83 680 85 15 333 33.3 245 ±5 ±500 ±50 254 MSKW2036 ±12 ±208 ±20.8 245 MSKW2037 ±15 ±167 ±16.7 246 85 MSKW2041 3.3 1200 120 106 78 MSKW2042 5 1000 100 127 MSKW2043 12 417 41.7 123 MSKW2035 MSKW2044 48 (36 ~ 75) 15 333 33.3 122 ±5 ±500 ±50 127 MSKW2046 ±12 ±208 ±20.8 122 MSKW2047 ±15 ±167 ±16.7 123 MSKW2045 15 85 15 82 100# 680 6 10 2016/07/26 Tel:886-6-2923150 REV : 9 Page 1 of 5 82 85 85 82 100# 85 85 # For each output E-mail:[email protected] 85 MSKW2000 SERIES DC/DC CONVERTER 5W, SMD-Package Input Specifications Parameter Input Surge Voltage (1 sec. max.) Start-Up Threshold Voltage Under Voltage Shutdown Model Min. Typ. Max. 12V Input Models -0.7 --- 25 24V Input Models -0.7 --- 50 48V Input Models -0.7 --- 100 12V Input Models 7.5 8 9 24V Input Models 14 16 18 48V Input Models 30 33 36 12V Input Models 6.5 7 8 24V Input Models 13 15 17 48V Input Models 28 31 34 --- 1000 3000 Short Circuit Input Power Input Filter All Models Unit VDC mW Internal Pi Type Conducted EMI Compliance to EN 55022,class A and FCC part 15,class A Remote On/Off Control Parameter Conditions Converter On Min. Typ. Max. Unit 2.5V ~ 5.5V or Open Circuit Converter Off -0.7V ~ 0.8V Control Input Current (on) Vctrl = Min. to Max. --- --- -200 μA Control Input Current (off) Vctrl = Min. to Max. --- --- -300 μA --- --- 10 mA Min. Typ. Max. Unit --- --- ±1.0 %Vnom. Dual Output, Balanced Loads --- ±0.5 ±2.0 % Vin=Min. to Max. --- ±0.1 ±0.3 % Load Regulation Io=20% to 100% --- ±0.3 ±1.0 % Ripple & Noise 0-20 MHz Bandwidth --- --- 85 mV P-P --- 250 500 μsec --- ±2 ±6 % --- ±0.01 ±0.02 %/℃ 115 140 165 % Control Common Referenced to Negative Input Standby Input Current Output Specifications Parameter Conditions Output Voltage Setting Accuracy Output Voltage Balance Line Regulation Transient Recovery Time 25% Load Step Change Transient Response Deviation Temperature Coefficient Over Load Protection Foldback Short Circuit Protection Continuous, Automatic Recovery General Specifications Parameter I/O Isolation Voltage Conditions Min. Typ. Max. Unit 60 Seconds 1500 --- --- VDC 1 Seconds 1800 --- --- VDC I/O Isolation Resistance 500 VDC 1000 --- --- MΩ I/O Isolation Capacitance 100KHz, 1V --- 650 750 pF 200 260 350 KHz Switching Frequency MTBF (calculated) MIL-HDBK-217F@25℃, Ground Benign Moisture Sensitivity Level (MSL) IPC/JEDEC J-STD-020D.1 Safety Approvals Level 2 UL/cUL 60950-1 recognition(CSA certificate), IEC/EN 60950-1(CB-report) E-mail:[email protected] 2016/07/26 1,000,000 Tel:886-6-2923150 REV : 9 Page 2 of 5 Hours MSKW2000 SERIES DC/DC CONVERTER 5W, SMD-Package Environmental Specifications Parameter Operating Ambient Temperature Range (See Power Derating Curve) Case Temperature Storage Temperature Range Humidity (non condensing) Cooling Lead-free Reflow Solder Process Conditions Natural Convection Min. Max. -40 +85 --+90 -50 +125 --95 Natural Convection IPC/JEDEC J-STD-020D.1 Unit ℃ ℃ ℃ % rel. H Power Derating Curve 100 Natural convection 20LFM Output Power (%) 80 400LFM 60 40 20 0 ~ -40 0 20 40 60 80 100 110 Ambient Temperature C Notes 1 2 3 4 5 6 7 Specifications typical at Ta=+25℃, resistive load, nominal input voltage and rated output current unless otherwise noted. Transient recovery time is measured to within 1% error band for a step change in output load of 75% to 100%. These power converters require a minimum output loading to maintain specified regulation, operation under no-load conditions will not damage these modules; however they may not meet all specifications listed. We recommend to protect the converter by a slow blow fuse in the input supply line. Other input and output voltage may be available, please contact factory. That “natural convection” is about 20LFM but is not equal to still air (0 LFM). Specifications are subject to change without notice. Package Specifications Mechanical Dimensions Connecting Pin Patterns 27.94 [1.10] 33.4 [1.31] 9 10 11 12 20.8 [0.82] 1 2 3 23.9 [0.94] 16 15 14 13 20.8 [0.82] 24 23 22 27.0 [1.06] 15.24 [0.60] 7.62 [0.3] 25.6 [1.01] 15.24 [0.6] 5.08 [0.2] 22.6 [0.89] 2.76 [0.11] 10.2 0.5 [0.4 0.02] 5 ►All dimensions in mm 0.15 S ►Tolerance: X.X±0.25 2016/07/26 Tel:886-6-2923150 REV : 9 Page 3 of 5 (inches) (X.XX±0.01) X.XX±0.13 ( X.XXX±0.005) ►Pins ±0.05 E-mail:[email protected] 1.7 [0.07] S SEATING PLANE 0~ 0.4 [0.02] 9.8 [0.39] 2.54 [0.10] (±0.002) 3.1 [0.12] 1.50 [0.06] MSKW2000 SERIES DC/DC CONVERTER 5W, SMD-Package Pin Connections Physical Characteristics Pin Single Output Dual Output 1 Remote On/Off Remote On/Off 2 -Vin -Vin 3 -Vin -Vin 9 NC Common 10 NC NC 11 NC -Vout 12 NC NC 13 NC NC 14 +Vout +Vout 15 NC NC 16 -Vout Common 22 +Vin +Vin 23 +Vin +Vin 24 NC NC NC : No Connection E-mail:[email protected] 2016/07/26 Tel:886-6-2923150 REV : 9 Page 4 of 5 Case Size : 33.4x20.8x10.2mm (1.31x0.82x0.4 inches) Case Material : Non-Conductive Black Plastic (flammability to UL 94V-0 rated) Pin Material : Phosphor Bronze Weight : 14g MSKW2000 SERIES DC/DC CONVERTER 5W, SMD-Package Test Setup Input Reflected-Ripple Current Test Setup Input reflected-ripple current is measured with a inductor Lin (4.7μH) and Cin (220μF, ESR < 1.0Ω at 100 KHz) to simulate source impedance. Capacitor Cin, offsets possible battery impedance. Current ripple is measured at the input terminals of the module, measurement bandwidth is 0-500 KHz. To Oscilloscope + + +Vin Lin Current Probe Cin Battery +Out DC / DC Converter -Vin Load -Out Peak-to-Peak Output Noise Measurement Test Use a Cout 0.47μF ceramic capacitor. Scope measurement should be made by using a BNC socket, measurement bandwidth is 0-20 MHz. Position the load between 50 mm and 75 mm from the DC/DC Converter. +Vin +Out Copper Strip Single Output DC / DC Converter -Vin Cout -Out Scope Resistive Load Copper Strip +Vin +Out Copper Strip Dual Output DC / DC Converter Com. Copper Strip -Vin -Out Scope Cout Resistive Load Cout Scope Copper Strip Technical Notes Remote On/Off Positive logic remote on/off turns the module on during a logic high voltage on the remote on/off pin, and off during a logic low. To turn the power module on and off, the user must supply a switch to control the voltage between the on/off terminal and the -Vin terminal. The switch can be an open collector or equivalent. A logic low is -0.7V to 0.8V. A logic high is 2.5V to 5.5V. The maximum sink current of the switch at on/off terminal during a logic low is 300μA. The maximum sink current of the switch at on/off terminal = 2.5 to 5.5V is 200μA or open. Overcurrent Protection To provide protection in a fault (output overload) condition, the unit is equipped with internal current limiting circuitry and can endure current limiting for an unlimited duration. At the point of current-limit inception, the unit shifts from voltage control to current control. The unit operates normally once the output current is brought back into its specified range. Input Source Impedance The power module should be connected to a low ac-impedance input source. Highly inductive source impedances can affect the stability of the power module. In applications where power is supplied over long lines and output loading is high, it may be necessary to use a capacitor at the input to ensure startup. Capacitor mounted close to the power module helps ensure stability of the unit, it is recommended to use a good quality low Equivalent Series Resistance (ESR < 1.0Ω at 100 KHz) capacitor of a 3.3μF for the 12V input devices and a 2.2μF for the 24V and 48V devices. + DC Power Source +Vin + +Out DC / DC Converter Load Cin - -Vin -Out Output Ripple Reduction A good quality low ESR capacitor placed as close as practicable across the load will give the best ripple and noise performance. To reduce output ripple, it is recommended to use 3.3μF capacitors at the output. + +Vin DC Power Source - +Out Single Output DC / DC Converter -Vin + Cout Load -Out Dual Output Com. DC / DC Converter DC Power Source - +Out +Vin -Vin -Out Cout Load Load Cout Maximum Capacitive Load The MSKW2000 series has limitation of maximum connected capacitance at the output. The power module may be operated in current limiting mode during start-up, affecting the ramp-up and the startup time. For optimum performance we recommend 100μF maximum capacitive load for dual outputs and 680μF capacitive load for single outputs. The maximum capacitance can be found in the data sheet. Thermal Considerations Many conditions affect the thermal performance of the power module, such as orientation, airflow over the module and board spacing. To avoid exceeding the maximum temperature rating of the components inside the power module, the case temperature must be kept below 90℃. The derating curves are determined from measurements obtained in a test setup. Position of air velocity probe and thermocouple 15mm / 0.6in 50mm / 2in Air Flow DUT 18, Sin Sin Road, An-Ping Industrial District, Tainan 702, Taiwan Tel: 886-6-2923150 Fax: 886-6-2923149 E-mail: [email protected] Minmax Technology Co., Ltd. 2016/07/26 REV : 9 Page 5 of 5