XP Power CPB1K5PS48 Ac-dc power supply Datasheet

AC-DC
660 - 1680 Watts
xppower.com
CPB1K/1K5 Series
•
Universal PFC Input
•
Low Profile (61 mm)
•
Wide Output Voltage Adjustment
•
Remote On/Off
•
Power Good Signal
•
Remote Sense
•
Peak Current Available
Specification
Input
Input Voltage
Input Frequency
Input Current
Inrush Current
Power Factor
Earth Leakage Current
General
•
•
•
•
•
•
85-264 VAC (120-370 VDC)
47-63 Hz
19 A at 115 VAC
40 A at 230 VAC
0.98/0.95 at 115/230 VAC
1.5 mA max at 230 VAC/60Hz
Output
Output Voltage
Output Voltage Trim
Minimum Load
Start Up Time
Hold Up Time
Drift
Line Regulation
Load Regulation
Ripple & Noise
Overvoltage Protection
Overtemperature
Protection
Overload Protection
Temperature
Coefficient
Remote Sense
Remote On/Off
•
•
•
•
•
•
•
•
•
•
•
See tables
See tables
No minimum load required
400 ms typical at 230 VAC, 100% load
20 ms typical at 100% load
±0.4% max
±0.5% max
±1.0% max 0-100% load
±1.0% pk-pk, 20MHz BW
110-130% Vnom, recycle input to reset
Operates in the event of fan failure or if
the operating temperature / derating
criteria is exceeded
• Operates at 105% of rated current (101%
of pk rating), <5 s auto recovery,
>5 s recycle input to reset
• ±1.25% max -20 ºC to +50 ºC
• Compensates for up to 0.3 V drop max
if not required, sense teminals must be
connected locally i.e +S to +M and
-S to -M on CN1
• 12 V 3 mA applied between RCG &
RC2 will inhibit the output of the unit
and the fan
Efficiency
Isolation
Switching Frequency
• See tables
• 3000 VAC Input to Output
2000 VAC Input to Ground
500 VAC Output to Ground
• 130 kHz PFC, 200 kHz PWM
Environmental
Operating Temperature • -20 ºC to +70 ºC, derate linearly from
+50 ºC to 50% at +70 ºC
Relative Humidity
• 20-90% non-condensing
Storage Temperature
• -20 ºC to +75 ºC
Shock
• 20 G 11 ms, once each x, y and z axis
Vibration
• 2 G, 10 Hz to 55 kHz, 3 min periods for 60
min along each x, y and z axis
EMC & Safety
Emissions
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Safety Approvals
• EN55022, level B conducted
EN55022, level A radiated
• EN61000-4-2, level 2 contact, level 3 air
• EN61000-4-3, level 3
• EN61000-4-4, level 3
• EN61000-4-5, level 3 line to line,
level 4 line to ground
• EN60950, UL60950, cUL (CSA 60950)
Current
Input
Voltage
Regulation
Ripple & Noise(2)
Efficiency(3)
Model
Number
40 mV
120 mV
76%
CPB1KPS3V3
40 mV
120 mV
81%
CPB1KPS05
36 mV
60 mV
150 mV
83%
CPB1KPS7V5
-
48 mV
100 mV
150 mV
84%
CPB1KPS12
-
60 mV
120 mV
150 mV
84%
CPB1KPS15
96 mV
150 mV
150 mV
86%
CPB1KPS24
-
114 mV
150 mV
200 mV
86%
CPB1KPS36
-
192 mV
300 mV
200 mV
86%
CPB1KPS48
Max
Peak
Line
Load
3.3 V (2.64 - 3.96)
200 A
-
20 mV
5.0 V (3.96 - 6.00)
200 A
-
20 mV
7.5 V (5.25 - 8.25)
134 A
-
12 V (8.25 - 13.20)
88 A
15 V (10.50 - 16.50)
70 A
24 V (16.50 - 26.40)
44 A
36 V (25.20 - 39.60)
29 A
48 V (38.40 - 56.00)
22 A
51 A (1)
Notes
1. Peak current duration 10 s max with duty cycle ≤ 35% 170-264 VAC only.
2. Measured over a 20 MHz bandwidth from 0 ºC to +50 ºC.
3. Measured at nominal 230 VAC input and 100% load.
Mechanical Details
Input terminal cover
110 ±0.5
150
H
V .A D J
CN 2
C N1
C N3
Output terminal(+ )
2.5
Output terminal(- )
( 24)
Output voltage
adjustable potentiometer
LED
51.25
165 ±0.5
240
29
(35)
Notes:
1. Tolerance: ±1.
2. Weight: 2.2 Kg.
3. Dimensions in mm.
6max
8-M4
Mounting Hole
(Both sides)
7 13
165±0.5
29
AIR FLOW
11.5
( 18) ( 25)
38±0.5
2-M4
2-º 9
61
10
FG
79
AC
( N)
CN3
CN2
CN1
25max
20
13 9 ( 7.5)
AC
( L)
AC(L)
AC(N)
FG( )
4-M4
Mounting Hole
(Bottom sides)
Name plate
104.75
M4
15.85
Peak Current
CN1/CN2 PIN CONNECTIONS
Function
+M
+ Output Voltage Monitoring
+S
+ Remote Sensing
-M
- Output Voltage Monitoring
-S
- Remote Sensing
VB
Voltage Balance
CB
Current Balance
TRM Adjustment of Output Voltage
- Remote Sensing
-S
RC2 Remote On/Off
RCG Remote On/Off Ground
Pin
1
2
3
4
5
6
7
8
CN3 PIN CONNECTIONS
Function
-S
- Remote Sensing
-S
- Remote Sensing
AUX Auxiliary Output (12V/0.1A)
RC1 Remote On/Off
AUXG AUX Ground
N.C
No Connection
PG
Power Good Signal
PGG Power Good Ground
Peak Current Conditions:
•
•
•
•
l
170-264 VAC
t1 ≤ 10 s
lp ≤ Rated peak current
lave ≤ Rated current
• Duty =
t1
t1 + t2
x 100 [%] ≤ 35%
p
(Peak Current)
Output Current (A)
Pin
1
2
3
4
5
6
7
8
9
10
l
ave
(Average Current)
t1
t2
Mating Connector & Terminal - CN1, CN2 & CN3
Connector
CN1
CN2
CN3
Mating Connector
S10B-PHDSS
PHDR-10VS
S8B-PHDSS
PHDR-8VS
Terminal
Reel SPHD-002T-P0.5
Loose BPHD-001T-P0.5
BPHD-002T-P0.5
Manufacturer
J.S.T
AC-DC
CPB1K
Models and Ratings
Current
Input
Voltage
Regulation
Ripple & Noise(3)
Efficiency(4)
Model
Number(3)
40 mV
120 mV
75%
CPB1K5PS3V3
40 mV
120 mV
81%
CPB1K5PS05
36 mV
60 mV
150 mV
81%
CPB1K5PS7V5
-
48 mV
100 mV
150 mV
82%
CPB1K5PS12
-
60 mV
120 mV
150 mV
86%
CPB1K5PS15
Max
Peak
Line
Load
3.3 V (2.64 - 3.96)
300 A
-
20 mV
5.0 V (3.96 - 6.00)
300 A
-
20 mV
7.5 V (5.25 - 8.25)
200 A
-
12 V (8.25 - 13.20)
125 A
15 V (10.50 - 16.50)
100 A
24 V (16.50 - 26.40)
70 A (1)
105 A (2)
96 mV
150 mV
150 mV
86%
CPB1K5PS24
36 V (25.20 - 39.60)
47 A (1)
70 A (2)
114 mV
150 mV
200 mV
86%
CPB1K5PS36
48 V (38.40 - 56.00)
35 A
192 mV
300 mV
200 mV
86%
CPB1K5PS48
(1)
-
Notes
1. At low input voltage i.e. 115 V nom derate to 65 A, 42 A and 32 A.
2. Peak current duration 10 s max with duty cycle ≤ 35% 170-264 VAC only.
3. Measured over a 20 MHz bandwidth from 0 ºC to +50 ºC.
4. Measured at nominal 230 VAC input and 100% load.
( 7.5)
8-M4
Mounting Hole
(Both sides)
25max
CN1
178
V.ADJ
CN2
CN3
152.4 ±0.5
FG
132
NC
)
CN1
CN2
CN3
Input terminal cover
107
AC
( N)
FG(
AC
( L)
AC(L)
AC(N)
NC
Name plate
13 9
M4
15.85
12.8
Mechanical Details
10
4
LED
Output terminal(-)
( 24)
Output voltage
adjustable potentiometer
Output terminal(+)
51.25
Notes:
1. Tolerance: ±1.
2. Weight: 3.4 Kg.
3. Dimensions in mm.
19
(45)
171.5 ±0.5
268
6max
8-M4
Mounting Hole
(Both sides)
4-M4
2-º 9
CN1/CN2 PIN CONNECTIONS
Function
+M
+ Output Voltage Monitoring
+S
+ Remote Sensing
-M
- Output Voltage Monitoring
-S
- Remote Sensing
VB
Voltage Balance
CB
Current Balance
TRM Adjustment of Output Voltage
- Remote Sensing
-S
RC2 Remote On/Off
RCG Remote On/Off Ground
Output Voltage Adjustment
Peak Current Conditions:
60-110% of the rated output voltage is achieved by:
•
•
•
•
1. Using on-board potentiometer
2. Applying a voltage externally between
TRM & -S on CN1 or CN2
3. Connecting a resistor externally between
TRM & -S on CN1 or CN2
The external voltage level is calculated below and
should not be less than -0.7 V or more than 3.0 V.
External Trim Voltage =
Pin
1
2
3
4
5
6
7
8
CN3 PIN CONNECTIONS
Function
-S
- Remote Sensing
-S
- Remote Sensing
AUX Auxiliary Output (12V/0.1A)
RC1 Remote On/Off
AUXG AUX Ground
N.C
No Connection
PG
Power Good Signal
PGG Power Good Ground
04 AUG 05
171.5 ±0.5
Required Vout x 2.5
Vnom
170-264 VAC
t1 ≤ 10 s
lp ≤ Rated peak current
lave ≤ Rated current
• Duty =
x 100 [%] ≤ 35%
t1
t1 + t2
Peak Current
l
p
(Peak Current)
Output Current (A)
Pin
1
2
3
4
5
6
7
8
9
10
19
11.5
10 15
61
38 ±0.5
AIR FLOW
( 18) ( 25)
AC-DC
CPB1K5
Models and Ratings
l
ave
(Average Current)
t1
t2
Mating Connector & Terminal - CN1, CN2 & CN3
Connector
CN1
CN2
CN3
Mating Connector
S10B-PHDSS
PHDR-10VS
S8B-PHDSS
PHDR-8VS
Terminal
Reel SPHD-002T-P0.5
Loose BPHD-001T-P0.5
BPHD-002T-P0.5
Manufacturer
J.S.T
Similar pages