ETC2 MI4012T-03 Thermoelectric cooler Datasheet

marlow industries inc.®
Thermoelectric Cooler
MI4012T
Performance Values
Hot Side Temperature (°C)
27°C
50°C
∆ Tmax (Vacuum):
114
129
Qmax (watts):
0.76
0.86
Imax (amps):
1.0
1.0
Vmax (vdc):
6.7
7.4
AC Resistance (ohms):
6.22
---
Mechanical Characteristics
Positive Lead
.520
[13.21]
Leads: 30 AWG (0.25) Bus
Solid Tinned Copper
.160
[4.06]
Negative Lead
.314
[7.98]
2.00 +/-.25
[50.80+/-6.35]
.676
[17.17]
Cold Side
.005 [0.13]
A
.001 [0.03]
.343+/-.013
[8.71 +/-0.33]
.001 [0.03]
Ceramic Material: Beryllia (BC)
Millimeters are in [ ]
Ordering Options
MI4012T-01
MI4012T-02
MI4012T-03
A
•
both surfaces are metallized –
cooler is mounted and shipped
on test base
hot side exterior is metallized –
cooler is mounted and shipped
on test base
•
•
•
For example, and MI4012T with only the hot side
metallized is specified as an MI4012T-02BC
Pretinned metallized ceramic surface(s) with
117°C solder.
Thermistor mounted on edge of cold side ceramic.
(Calibration available.)
Elevated temperature burn-in with test data provided.
no exterior metallization
102-0052, Rev F
Thermoelectric Cooler
MI4012T
Performance Curves
Environment: Vacuum
Hot Side Temperature: 27°C
80.0
40.0
120.0
80.0
40.0
0.0
0.0
8.0
8.0
6.0
4.0
Q=0
T=0
2.0
0.0
0.0
0.2
0.4 0.6 0.8 1.0
CURRENT (AMPS)
1.2
VOLTAGE (VDC)
T (C)
120.0
HEAT
LOAD
(WATTS)
0.00
0.10
0.20
0.30
0.40
0.50
0.60
0.70
0.80
160.0
T (C)
HEAT
LOAD
(WATTS)
0.00
0.10
0.20
0.30
0.40
0.50
0.60
0.70
160.0
VOLTAGE (VDC)
Hot Side Temperature: 50°C
6.0
4.0
Q=0
T=0
2.0
0.0
0.0
0.2
0.4 0.6 0.8 1.0
CURRENT (AMPS)
1.2
For performance information with hot side temperatures other than 27°C or 50°C, consult one of our Applications Engineers.
Installation
Recommended mounting methods: Bonding with thermal epoxy or soldering with metallized ceramics. For additional
information, please refer to our TEC Installation Guide.
Operation Cautions
For maximum reliability, storage and operation below 85°C in a non-condensing environment is recommended. To
minimize thermal stress, use linear/proportional temperature control or a similar method rather than an ON/OFF method.
Marlow Industries, Inc.
10451 Vista Park Road
Dallas Texas 75238-1645
TEL: 214-340-4900
FAX: 214-341-5212
Internet: http://www.marlow.com
Marlow Industries Europe
Aberdeen House, South Road
Haywards Heath
West Sussex RH164NG UK
TEL: +44 (0)1444-443404
FAX: +44 (0)1444-443334
Marlow Industries Asia
1-1-8-401
Uehara, Shibuya-ku
Tokyo, Japan 151-0064
TEL: +81 (3) 5454-5280
FAX: +81 (3) 5454-5281
Copyright 2000, Marlow Industries, Inc. Marlow Industries reserves the right to change the design and specifications of products without notice. 102-0052, Rev F