Infineon BTS129 Tempfet(n channel enhancement mode temperature sensor with thyristor characteristic) Datasheet

TEMPFET® BTS 129
Features
●
●
●
●
N channel
Enhancement mode
Temperature sensor with thyristor characteristic
The drain pin is electrically shorted to the tab
1
Pin
1
2
3
G
D
S
Type
VDS
ID
RDS(on)
Package
Ordering Code
BTS 129
60 V
27 A
0.05 Ω
TO-220AB
C67078-A5013-A2
2
3
Maximum Ratings
Parameter
Symbol
Values
Unit
Drain-source voltage
VDS
60
V
Drain-gate voltage, RGS = 20 kΩ
VDGR
60
Gate-source peak voltage, aperiodic
Vgs
± 20
Continuous drain current, TC = 25 °C
ID
27
ISO drain current
TC = 85 °C, VGS = 10 V, VDS = 0.5 V
ID-ISO
7.5
A
Pulsed drain current,
TC = 25 °C
ID puls
108
Short circuit current,
Tj = – 55 ... + 150 °C
ISC
80
Short circuit dissipation, Tj = – 55 ... + 150 °C
PSCmax
1200
Power dissipation
Ptot
75
Operating and storage temperature range
Tj, Tstg
– 55 ... + 150
°C
DIN humidity category, DIN 40 040
–
E
–
IEC climatic category, DIN IEC 68-1
–
55/150/56
Thermal resistance
Chip-case
Chip-ambient
Rth JC
Rth JA
≤ 1.67
≤ 75
W
K/W
1
19.02.04
TEMPFET® BTS 129
Electrical Characteristics
at Tj = 25 °C, unless otherwise specified.
Parameter
Symbol
Values
Unit
min.
typ.
max.
60
–
–
2.5
3.0
3.5
Static Characteristics
Drain-source breakdown voltage
VGS = 0, ID = 0.25 mA
V(BR)DSS
Gate threshold voltage
VGS = VDS, ID = 1 mA
VGS(th)
Zero gate voltage drain current
VGS = 0 V, VDS = 60 V
Tj = 25 °C
Tj = 150 °C
I DSS
Gate-source leakage current
VGS = 20 V, VDS = 0
Tj = 25 °C
Tj = 150 °C
I GSS
Drain-source on-state resistance
VGS = 10 V, ID =17 A
RDS(on)
V
µA
–
–
1
100
10
300
–
–
10
2
100
4
–
0.04
0.05
8.0
13.0
18.0
700
940
1250
–
500
750
–
180
270
Turn-on time ton, (ton = td(on) + tr)
td(on)
VCC = 30 V, VGS = 10 V, ID = 3 A, RGS = 50 Ω t
–
25
40
–
60
90
Turn-off time toff, (toff = td(off) + tf)
td(off)
VCC = 30 V, VGS = 10 V, ID = 3 A, RGS = 50 Ω t
–
100
130
–
75
95
nA
µA
Ω
Dynamic Characteristics
Forward transconductance
VDS ≥ 2 × ID × RDS(on)max, ID = 17 A
gfs
Input capacitance
VGS = 0, VDS = 25 V, f = 1 MHz
Ciss
Output capacitance
VGS = 0, VDS = 25 V, f = 1 MHz
Coss
Reverse transfer capacitance
VGS = 0, VDS = 25 V, f = 1 MHz
Crss
r
f
2
S
pF
ns
19.02.04
TEMPFET® BTS 129
Electrical Characteristics (cont’d)
at Tj = 25 °C, unless otherwise specified.
Parameter
Symbol
Values
Unit
min.
typ.
max.
Reverse Diode
Continuous source current
IS
–
–
27
Pulsed source current
I SM
–
–
108
Diode forward on-voltage
I F = 27 A, VGS = 0 V
VSD
Reverse recovery time
I F = I S, diF/dt = 100 A/µs, VR = 30 V
t rr
Reverse recovery charge
I F = I S, diF/dt = 100 A/µs, VR = 30 V
Q rr
A
V
–
1.3
1.8
ns
–
150
–
µC
–
1.0
–
0.7
1.4
1.5
–
–
10
–
–
10
–
–
600
0.05
0.05
0.1
0.2
0.5
0.3
150
–
–
0.5
–
2.5
Temperature Sensor
Forward voltage
ITS(on) = 10 mA, Tj = – 55 ... + 150 °C
Sensor override, tp ≤ 100 µs
Tj = – 55 ... + 160 °C
VTS(on)
Forward current
Tj = – 55 ... + 150 °C
Sensor override, tp ≤ 100 µs
Tj = – 55 ... + 160 °C
ITS(on)
Holding current, VTS(off) = 5 V,
Tj = 25 °C
Tj = 150 °C
IH
Switching temperature
VTS = 5 V
TTS(on)
Turn-off time
VTS = 5 V, ITS(on) = 2 mA
toff
3
V
mA
°C
µs
19.02.04
TEMPFET® BTS 129
Examples for short-circuit protection
at Tj = – 55 ... + 150 °C, unless otherwise specified.
Parameter
Symbol
Examples
Unit
1
2
–
Drain-source voltage
VDS
15
30
–
Gate-source voltage
VGS
8.1
5.9
–
Short-circuit current
ISC
≤ 80
≤ 37
–
A
Short-circuit dissipation
PSC
1200
1100
–
W
Response time
Tj = 25 °C, before short circuit
tSC(off)
ms
25
Short-circuit protection ISC = f (VDS)
Parameter: VGS
Diagram to determine ISC for Tj = – 55 ... + 150 °C
V
25
–
Max. gate voltage VGS(SC) = f (VDS)
Parameter: Tj = – 55 ... + 150 °C
4
19.02.04
TEMPFET® BTS 129
Safe operating area ID = f (VDS)
Parameter: D = 0.01, TC = 25 °C
Typical output characteristics ID = f (VDS)
Parameter: tp = 80 µs
60
ΙD
BTS 129
SIT00562
Ptot = 75W
A
VGS = 20V 10V
8V
9V
50
7.5V
40
7V
6.5V
30
6V
20
5.5V
5V
10
0
4.5V
4V
0
1
2
3
4
V 5
V DS
Drain-source on-state resistance
RDS(on) = f (Tj)
Parameter: ID = 17 A, VGS = 10 V (spread)
Typ. drain-source on-state resistance
RDS(on) = f (ID)
Parameter: VGS
5
19.02.04
TEMPFET® BTS 129
Typ. transfer characteristic
ID = f (VGS)
Parameter: tp = 80 µs, VDS = 25 V
Typ. transconductance gfs = f (ID)
Parameter: tp = 80 µs, VDS = 25 V
Gate threshold voltage VGS(th) = f (Tj)
Parameter: VDS = VGS, ID = 1 mA
Continuous drain current ID = f (TC)
Parameter: VGS ≥ 10 V
6
19.02.04
TEMPFET® BTS 129
Typ. gate-source leakage current
IGSS = f (TC)
Parameter: VGS = 20 V, VDS = 0
Typ. capacitances C = f (VDS)
Parameter: VGS = 0, f = 1 MHz
Forward characteristics of reverse diode
IF = f (VSD)
Parameter: Tj, tp = 80 µs
Transient thermal impedance ZthJC = f (tp)
Parameter: D = tp/T
7
19.02.04
TEMPFET® BTS 129
TO 220 AB
Standard
4.4
3.7
1.3
15.6
9.2
17.5
1)
2)
13.5
3)
4.6
1
12.8
2.8
9.9
9.5
Ordering Code
C67078-A5013-A2
0.75
2.54
1.05
2.54
0.5
2.4
GPT05155
1) punch direction, burr max. 0.04
2) dip tinning
3) max. 14.5 by dip tinning press burr max. 0.05
8
19.02.04
TEMPFET® BTS 129
Edition 04.97
Published by Infineon Technologies AG,
St.-Martin-Strasse 53,
D-81541 München, Germany
© Infineon Technologies AG 2000.
All Rights Reserved.
Attention please!
The information herein is given to describe certain components and shall not be considered as warranted
characteristics.
Terms of delivery and rights to technical change reserved.
We hereby disclaim any and all warranties, including but not limited to warranties of non-infringement, regarding
circuits, descriptions and charts stated herein.
Infineon Technologies is an approved CECC manufacturer.
Information
For further information on technology, delivery terms and conditions and prices please contact your nearest
Infineon Technologies Office in Germany or our Infineon Technologies Representatives worldwide (see address
list).
Warnings
Due to technical requirements components may contain dangerous substances. For information on the types in
question please contact your nearest Infineon Technologies Office.
Infineon Technologies Components may only be used in life-support devices or systems with the express written
approval of Infineon Technologies, if a failure of such components can reasonably be expected to cause the failure
of that life-support device or system, or to affect the safety or effectiveness of that device or system. Life support
devices or systems are intended to be implanted in the human body, or to support and/or maintain and sustain
and/or protect human life. If they fail, it is reasonable to assume that the health of the user or other persons may
be endangered.
9
19.02.04
Similar pages