The MBC41 Series of ultra-low open frame medical power supplies feature a wide universal AC input range of 85 V – 264 VAC, offering output power 40 W with natural convection cooling. They are available in a variety of isolated single output voltages. The MBC41 ultra low profile series is also available in a PCB mount format, facilitating simple embedded integration onto user’s main PCB assembly. The MBC Series is designed and approved to the latest medical standards (EN/IEC 60601-1), providing 2 x MOPP isolation for Class I & Class II applications. These power supplies are ideal for medical, telecom, datacom, industrial equipment and other applications. • 3 x 2 x 0.75 Inches Form factor • PCB Mount option available • 40 Watts Convection • Approved to EN/IEC 60601-1 • Efficiencies 85% Typical • -40 to 70 degree operating temperature • Dual fusing • 2 million hours, Telcordia -SR332-issue 3 MTBF • Standby Power < 0.3 W • Medical (BF) Safety Approvals • Diagnostic • Dialysis • Drug Pump • Home Health Care • Monitoring • Portable Equipment MBC41 Series 2 MBC41-1T05L Screw Terminal MBC41-1005L Header MBC41-1005P PCB Mount MBC41-1T12L Screw Terminal MBC41-1012L Header MBC41-1012P PCB Mount MBC41-1T15L Screw Terminal MBC41-1015L Header MBC41-1015P PCB Mount MBC41-1T24L Screw Terminal MBC41-1024L Header MBC41-1024P PCB Mount MBC41-1T30L Screw Terminal MBC41-1030L Header MBC41-1030P PCB Mount MBC41-1T48L Screw Terminal MBC41-1048L Header MBC41-1048P PCB Mount MBC41-1T58L Screw Terminal MBC41-1058L Header MBC41-1058P PCB Mount COVER-41-XBC3 5V 5A 0.0 A 1.5% 12 V 3.33 A 0.0 A 1% 15 V 2.67 A 0.0 A 1% 24 V 1.67 A 0.0 A 1% 30 V 1.33 A 0.0 A 1% 48 V 0.83 A 0.0 A 1% 58 V 0.69 A 0.0 A 1% metal cover kit accessory Specifications are for nominal input voltage, 25°C unless otherwise stated. Input Voltage Universal Input Frequency 85 - 264 VAC / 390 VDC 47 - 63 Hz Input Current 115 VAC: 230 VAC: 0.8 A max. 0.4 A max. No Load Power Typical < 0.3 W 115 VAC: 230 VAC: 264 VAC: Typical (N.A. For Class II Option- without input Earth pin) Touch current 25 A 45 A 75 A 300 A µA < 100 µA Typical 65 kHz Inrush Current Leakage Current Switching Frequency 1 For Class II Option (without input Earth pin) add suffix: -2 (e.g.: MBC41-1012L-2). Ripple is peak to peak with 20 MHz bandwidth and 10 µF (Tantalum capacitor) in parallel with a 0.1 µF capacitor at rated line voltage and load ranges. Output ripple can be more than 10% of the output voltage. 3 When used in Cover Kit, de-rate output power to 70 % under all operating conditions. Cover Kit is not suited for PCB mount version. 2 [email protected] MBC41 Series 3 Output Power Convection cooling 40 W Efficiency Typical 85% Hold-up Time 230 VAC: 6 ms Line Regulation +/-0.5% Load Regulation +/-1% Transient Response 25% step load change, at 0.1 A/ µs slew rate, 50% duty cycle, 50 Hz = 4% recovery time < 5 ms Rise Time Typical 50 ms Set Point Tolerance 2% (3% for 5 V model) Over Current Protection > 110% Over Voltage Protection 110 to 140% Short Circuit Protection Operating Temperature Hiccup mode Startup is guaranteed with spec. deviation, see Fig. 1 Storage Temperature -40 to +70°C -40 to 0°C -40 to +85°C Relative Humidity Non-condensing 5% to 95% Altitude Operating: Non-operating: 16,000 ft 40,000 ft. MTBF Telcordia -SR332-issue 3 2 million hours Conducted Emissions Input Current Harmonics EN 55011-B, CISPR22-B, FCC PART15-B EN 55011 A; with external core (King core K5B RC 25x12x15-M in input cable) EN 61000-3-2 Pass Pass Level B Class D Voltage Fluctuation and Flicker EN 61000-3-3 Pass ESD Immunity EN 61000-4-2 Level 4, Criterion A Radiated Field Immunity EN 61000-4-3 Level 3, Criterion A Electrical Fast Transient Immunity EN 61000-4-4 Level 3, Criterion A Surge Immunity EN 61000-4-5 Level 3, Criterion A Conducted Immunity EN 61000-4-6 Level 3, Criterion A Magnetic Field Immunity EN 61000-4-8 Level 4, Criterion A Voltage Dips, Interruptions EN 61000-4-11 Criterion A & B Radiated Emissions Europe, Middle East +353 61 225 977 North America +1 408 785 5200 © 2017 Bel Power Solutions & Protection BCD.00892_AB Asia-Pacific +86 755 298 85888 MBC41 Series 4 Input to Output: (Medical applications) Input to GND: (Not Applicable For Class II Option) Output to GND: for type BF for type B (N/A for Class II Option) Approved to the latest edition of the following standards: CSA/UL60601-1, EN60601-1 and IEC60601-1. Isolation Voltage Safety Standard(s) Agency Approvals Nemko, UL, C-UL CE mark Complies with LVD Directive 4000 VAC 1500 VAC 1500 VAC 500 VAC AC Input Connector J1 Screw Terminal / Header Pin 1 Pin 2 Pin 3 AC Line Not Fitted AC Neutral Tyco: 640445-3 Mating: 647402-3; Pins: 3-647409-1 DC Output Connector J2 Screw Terminal / Header Pin 1, 2 Pin 3, 4 V1 +VE V1 -VE Tyco: 640445-4 Mating: 647402-4; Pins: 3-647409-1 Weight approx. 100 g Dimensions 76.2 x 50.8 x 19.05 mm (3 x 2 x 0.75 inches) (Header) % Figure 1. Derating Curve for all Outputs De-rate linearly from 100% at 50°C to 50% at 70°C [email protected] MBC41 Series 5 Mechanical Drawing – Options with Header and Screw Terminal Mechanical Drawing – PCB Mount Option NOTES: In case the PCB is mounted in a metal enclosure, using metal hardware ensure the following: 1 Stand off, used to mount PCB has OD of 5.4 mm max. 2 Screws, used to fix PCB on stand off, have head dia of 6.0 mm max. 3 Washer, if used, to have dia of 6.5 mm max. NUCLEAR AND MEDICAL APPLICATIONS - Products are not designed or intended for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. Europe, Middle East +353 61 225 977 North America +1 408 785 5200 © 2017 Bel Power Solutions & Protection BCD.00892_AB Asia-Pacific +86 755 298 85888