Bothhand B3-0515D3-LF 3 watt dual output dc-dc converter Datasheet

B3-0515D3 LF
1.
3 Watt Dual Output DC-DC Converter
Features:
1.1.
14 Pin DIL Package
1.2.
Low Ripple and Noise
1.3.
Input / Output Isolation :1000Vdc
1.4.
Net Weight : 2.7 g Typical
1.5
RoHS Converter Certified By SGS
2. Input Specifications:
2.1. Input Voltage
: 4.5 ~ 5.5 Vdc
5V ± 10 %
2.2. Max. Input Current
: 720mA Max.
@ Vin = 5 V and Output at Full Load.
2.3. Quiescent Current
: 35 mA Typical
@ Vin = 5 V and No Load.
2.4. Input Ripple
: 100 mV Typical
2.5. Input Filter
: Internal Capacitor
2.6. Switching Frequency
: 90 KHz Typ.
2.7. Input Efficiency
: 83 %
Min.
@ Vin = 5 V ,Output at Full Load ,No Input
Electrolytic Capacitor and 20 MHz BW.
@ Vin = 5V and 100 % Load. ( 87% Typical )
3. Output Specification:
3.1.
Output Voltage
: ±15 Vdc
@ Vin = 5 V and Output at Full Load.
3.2.
Output Voltage Accuracy
: ±3%
Vo = 14.55 ~ 15.45 Vdc
3.3.
Max. Output Current
: ± 100 mA
3.4.
Min. Output Current
: ± 20 mA
3.5.
Ripple
: ±120 mVp-p
3.6.
Line Regulation
: ±1.3 %/ 1.0 % Max.
See Note (1).
3.7.
Load Regulation
: ±8 %
Max.
See Note (2).
3.8.
Max. Capacitive Load
: ±330
uF
3.9.
Temperature Coefficient
: ± 0.02 %/℃
Max. @ 20 MHz BW
Note :
(1). Line Regulation : Set output load to full load, Then adjust input voltage from 4. 5V to 5. 5V ( 10% change ), The output
voltage difference must be within 13% of the output at full load and nominal input.
(2). Load Regulation : Set input voltage at 5V, Then changing Output load from 20% to 100% rated Load. The output
voltage difference must be within 8% of the output at full load and nominal input.
(3). All specification are typical at 25℃ unless otherwise state.
4. General Specification:
4.1.
Isolation Voltage
: 1000 Vdc
Test duration 60 Seconds / 0.5 mA
4.2.
Isolation Resistance
: 1000 MΩ Min.
@ 500 Vdc
4.3.
Operating Temperature (1)
: -40℃ ~ +85℃
@ Ambient Temperature with Natural convention
4.4.
Operating Temperature (2)
: -40℃ ~ +95℃
@ Case Surface Temperature
4.5.
Storage Temperature
: -55℃ ~ +105℃
4.6.
Humidity
: Up to 95 %
4.7.
Cooling
: Free air convection
Bothhand USA http://www.bothhandusa.com
Page 1
of 6
B3-0515D3 LF-Spec-160701
Approve By :
Check By:
Test By:楊陽
B3-0515D3 LF
4.8.
3 Watt Dual Output DC-DC Converter
: Non-Conductive Plastic
Case Type
5. Mechanical Dimension:
1K Vdc – Dual
Pin
-Vin
14
Pin
1
+Vin
2
13
---
3
12
---
-Vo
11
5
---
10
6
+Vo
9
Common
8
4
NC
7
“---” means Omitted
Note:
6. Recommended Footprint Details :
Units : mm (inch)
Tolerance : 0.xx ± 0.25(0.xx ± 0.01)
( Top View )
7. Power Derating Curve :
8. Efficiency & Output Load Chart :
Bothhand USA http://www.bothhandusa.com
Page 2
of 6
B3-0515D3 LF-Spec-160701
Approve By :
Check By:
Test By:楊陽
B3-0515D3 LF
3 Watt Dual Output DC-DC Converter
BOTHHAND USA
Application note
Test Configurations :
All specifications are typical at nominal input, full load and 25°C unless otherwise stated.
A
A
DC
Power Supply
DC/DC
converter
V
V
Load
◎DC Power Supply: It offers a wide voltage and current range precisely.
◎Current meter (A): Accuracy 200μA ~ 200mA 4 ranges+(0.2% rdg + 2 digits)
2000mA ~ 20A
2 ranges+(0.3% rdg + 2 digits).
◎Voltage meter (V): Accuracy +(0.03% rdg + 4 digits).
◎Load: At full load.
◎Wires: The resistance of the wires must be small.
1. Input voltage range: Narrow input voltage range(±10%)、wide input voltage range
(2:1 and 4:1)。
EX: Narrow input voltage range(±10%)
5VDC nominal input 
4.5~5.5VDC
5VDC nominal input

10.8~13.2VDC
24VDC nominal input

21.6~26.4VDC
Wide input voltage range 2:1
5VDC nominal input

5VDC nominal input

24VDC nominal input

48VDC nominal input

Wide input voltage range 4:1 (W)
24VDC nominal input

48VDC nominal input 
2. Input power :
4.5~4.5VDC
4.5~9VDC
9~36VDC
36~75VDC
4.5~36VDC
9~75VDC
Bothhand USA http://www.bothhandusa.com
Page 3
of 6
B3-0515D3 LF-Spec-160701
Approve By :
Check By:
Test By:楊陽
B3-0515D3 LF
Pin = Vin x Iin
3 Watt Dual Output DC-DC Converter
Vin:Input voltage
Iin:Input current
3. Output power :
Pout = Vout x Iout
Vout:Output voltage
Iout:Output current
4. Efficiency :
Efficiency =
Pout x100%
Pin
Pout: Output power
Pin: Input power
5. Voltage accuracy:
│Vout-Vout(nominal)│ x100%
Vout
Vout:Output voltage
Vout(nominal):Nominal output voltage
6. Line regulation: (1) Wide input voltage range and regulated output voltage series.
│Vout(LL)-Vout(HL)│ x100%
Vout(LL)
LL: Low Line input voltage
HL: High Line input voltage
(2) Narrow input voltage range(±10%)and unregulated output voltage series.
│
│
Line regulation=
ΔVout
ΔVin
ΔVout = Vout(+10%)-Vout(-10%) x100%
Vout
Vout(+10%):Output voltage at Vin = 1.1xVin(nominal)&full load
Vout(-10%):Output voltage at Vin = 0.4.5xVin(nominal)&full load
Vout:Output voltage at Vin = Vin(nominal)&full load
ΔVin =
Vin(+10%)-Vin(-10%)
x100%
Vin(nominal)
Vin(+10%):Input voltage = 1.1xVin(nominal)
Bothhand USA http://www.bothhandusa.com
Page 4
of 6
B3-0515D3 LF-Spec-160701
Approve By :
Check By:
Test By:楊陽
B3-0515D3 LF
3 Watt Dual Output DC-DC Converter
Vin(-10%):Input voltage = 0.4.5xVin(nominal)
Vin(nominal):Nominal Input voltage
7. Load regulation :
│Vout(FL)-Vout(NL)│ x100%
Vout(FL)
Vout(FL): Output voltage at full load
Vout(NL): Output voltage at 25% full load or 10% full load
8. Ripple and Noise: as shown below. The bandwidth is 0-20MHz.
Ripple&Noise
Noise
Ripple
Output Ripple&Noise measurement test circuit: as shown below.
Copper strip
DC/DC
converter
Co
Oscilloscope
Load
Copper strip
Co: usually 0.47uF.
9. Temperature derating curve: The DC-DC converter will operate over a wider
temperature range if less power is drawn from the output and the device is already
running. The temperature derating curve shows the operating power-temperature
range. As shown below.
Bothhand USA http://www.bothhandusa.com
Page 5
of 6
B3-0515D3 LF-Spec-160701
Approve By :
Check By:
Test By:楊陽
B3-0515D3 LF
3 Watt Dual Output DC-DC Converter
120
100
Output 80
Power 60
(%)
40
20
0
-40
-20
0
20
40
60
80
100
120
Ambient Temp.TA ( ℃ )
10. Switching frequency: The nominal operating frequency of the DC-DC
converters.
11. Input to output isolation: The dielectric breakdown strength test between input
and output circuits. This is the isolation voltage the device is capable of
withstanding for a specified time, usually 1 second or 1 minute.
Bothhand USA http://www.bothhandusa.com
Page 6
of 6
B3-0515D3 LF-Spec-160701
Approve By :
Check By:
Test By:楊陽
Similar pages