LQ104V1DG51 TFT-LCD Module (Model Number: LQ104V1DG51) Specifications Spec No.: LD-13708A Dated: June 6, 2002 PREPARED BY : DATE SPEC No. LD-13708A FILE No. ISSUE : Jul.18 2001 APPROVED BY : DATE PAGE : TFT Liquid Crystal Display Group SHARP CORPORATION 18 pages APPLICABLE GROUP TFT Liquid Crystal Display Group SPECIFICATION DEVICE SPECIFICATION FOR TFT-LCD Module MODEL No. LQ104V1DG51 □ CUSTOMER'S APPROVAL DATE PRESENTED BY BY K.Shiono General Manager Development Engineering Dept.Ⅱ TFT Division.Ⅱ TFT LIQUID CRYSTAL DISPLAY GROUP SHARP CORPORATION LD13708-1 1. Application This technical literature applies to color TFT-LCD module, LQ104V1DG51 These technical literature sheets are the proprietary product of SHARP CORPORATION(”SHARP) and include materials protected under copyright of SHARP. Do not reproduce or cause any third party to reproduce them in any form or by any means, electronic or mechanical, for any purpose, in whole or in part, without the express written permission of SHARP . The device listed in these technical literature sheets was designed and manufactured for use in general electronic equipment. In case of using the device for applications such as control and safety equipment for transportation(aircraft, trains, automobiles, etc. ), rescue and security equipment and various safety related equipment which require higher reliability and safety, take into consideration that appropriate measures such as fail-safe functions and redundant system design should be taken . Do not use the device for equipment that requires an extreme level of reliability, such as aerospace applications, telecommunication equipment(trunk lines), nuclear power control equipment and medical or other equipment for life support . SHARP assumes no responsibility for any damage resulting from the use of the device which does not comply with the instructions and the precautions specified in these technical literature sheets . Contact and consult with a SHARP sales representative for any questions about this device . 2. Overview This module is a color active matrix LCD module incorporating amorphous silicon TFT (Thin Film Transistor). It is composed of a color TFT-LCD panel, driver ICs, control circuit and power supply circuit and a backlight unit. Graphics and texts can be displayed on a 640×3×480 dots panel with 262,144 colors by supplying 18 bit data signal (6bit/color), four timing signals,+3.3V/ +5V DC supply voltage for TFT-LCD panel driving and supply voltage for backlight. The TFT-LCD panel used for this module is a low-reflection and higher-color-saturation type. Therefore, this module is also suitable for the multimedia use. Optimum viewing direction is 6 o'clock. Backlight-driving DC/AC inverter is not built in this module. LD13708-2 3. Mechanical Specifications Parameter Specifications Diagonal Unit Display size 26 (10.4") cm Active area 211.2(H)×158.4(V) mm Pixel format 640(H)×480(V) pixel (1 pixel=R+G+B dots) Pixel pitch 0.330(H)×0.330(V) Pixel configuration R,G,B vertical stripe Display mode Normally white Unit outline dimensions *1 246.5(W)×179.4(H)×14.2(D) Mass 600±20 Surface treatment Anti-glare and hard-coating Haze value = 26%±5% *1.Note: excluding backlight cables. Outline dimensions is shown in Fig.1-1/Fig.1-2 mm mm g LD13708-3 4. Input Terminals 4-1. TFT-LCD panel driving CN1 Used connector:DF9MA-31P-1V (Hirose Electric Co., Ltd.) 1 31 Corresponding connector: DF9-31S-1V ( 〃 ) 2 30 DF9A-31S-1V( 〃 ) CN1 pin arrangement from module surface DF9B-31S-1V( 〃 ) (Transparent view) DF9M-31S-1V( 〃 ) Pin No. Symbol Function Remark 1 GND 2 CK Clock signal for sampling each data signal 3 Hsync Horizontal synchronous signal 【Note1】 4 Vsync Vertical synchronous signal 【Note1】 5 GND 6 R0 RED data signal(LSB) 7 R1 RED data signal 8 R2 RED data signal 9 R3 RED data signal 10 R4 RED data signal 11 R5 RED data signal(MSB) 12 GND 13 G0 GREEN data signal(LSB) 14 G1 GREEN data signal 15 G2 GREEN data signal 16 G3 GREEN data signal 17 G4 GREEN data signal 18 G5 GREEN data signal(MSB) 19 GND 20 B0 BLUE data signal(LSB) 21 B1 BLUE data signal 22 B2 BLUE data signal 23 B3 BLUE data signal 24 B4 BLUE data signal 25 B5 BLUE data signal(MSB) 26 GND 27 ENAB Signal to settle the horizontal display position 【Note2】 28 Vcc +5.0V power supply 29 Vcc +5.0V power supply 30 R/L Horizontal display mode select signal 【Note3】 31 U/D Vertical display mode select signal 【Note4】 ※The shielding case is not connected with GND. 【Note1】480 line, 400 line or 350 line mode Mode 480 lines 400 lines 350 lines is selected by the polarity combination Hsync negative negative Positive of the both synchronous signals. Vsync negative positive Negative 【Note2】The horizontal display start timing is settled in accordance with a rising timing of ENAB signal. In case ENAB is fixed "Low", the horizontal start timing is determined as described in 7-2. Don't keep ENAB “High" during operation. LD13708-4 【Note3】R/L=High、U/D=Low R/L=Low、U/D=Low 【Note4】R/L=High、U/D=High R/L=Low、U/D=High 4-2. Backlight driving Used connector : BHR-03VS-1(JST) CN2、CN3 Corresponding connector :SM02(8.0)B-BHS(JST) Pin no. Symbol 1 VHIGH Function Cable color Power supply for lamp Pink (High voltage side) 2 NC This is electrically opened. 3 VLOW Power supply for lamp White (Low voltage side) 5. Absolute Maximum Ratings Parameter Input voltage Symbol Condition VI Ratings Unit Ta=25℃ -0.3 ~ Vcc+0.3 V +5V supply voltage Vcc Ta=25℃ 0 ~ + 6 V Storage temperature Tstg - -30 ~ +70 ℃ Operating temperature (Ambient) Topa - -10 ~ +65 ℃ 【Note1】CK,R0~R5,G0~G5,B0~B5,Hsync,Vsync,ENAB, R/L, U/L 【Note2】Humidity:95%RH Max. at Ta≦40℃. Maximum wet-bulb temperature at 39℃ or less at Ta>40℃. No condensation. Remark 【Note1】 【Note2】 LD13708-5 6. Electrical Characteristics 6-1.TFT-LCDpaneldriving Ta=25℃ Parameter Supply voltage Power Supply Current dissipation Permissive input ripple voltage Input voltage (Low) Input voltage (High) Symbol Vcc Min. Typ. Max. +3.0 +3.3 +5.0 +5.5 Unit V Remark 【Note1】 Icc - 350 400 mA Vcc=3.3V 【Note2】 Icc - 250 300 mA Vcc=5.0V 【Note2】 VRF VIL VIH IOL1 - - - - - - 0.7Vcc - 100 mVp-p 0.3Vcc V - V μA 1.0 - - μA 60.0 IOH1 - - 1.0 IOH2 - - 60.0 【Note3】 VI=0V 【Note4】 VI=0V Input current (low) IOL2 Vcc=+5V 【Note5】 VI=Vcc μA 【Note6】 VI=Vcc μA Input current (High) 【Note7】 【 NOTE 1】 Vcc-turn-on conditions VCC VCC 4.5V T1≦15ms 0<T2≦10ms 0<T3≦1s 1s<T4 2.8V 0.3V T3 Vcc-dip conditions 480 line mode/Vcc=+3.3V/+5.0V 【Note3】 CK,R0~R5,G0~G5,B0~B5,Hsync,Vsync,ENAB, R/L,U/D 【Note4】 CK,R0~R5,G0~G5,B0~B5,Hsync,Vsync,ENAB 【Note5】 R/L 【Note6】 CK,R0~R5,G0~G5,B0~B5,Hsnc,Vsync 【Note7】 ENAB,U/D T1 T4 VCC T2 3.0V 1) 2.7V≦Vcc<3.0V td≦10ms 2) Vcc<2.7V Vcc-dip condition should also follow The Vcc-turn-on conditions 【Note2】 Typical current situation : 16-gray-bar pattern. 0.3V 2.7V Td RGB RGB RGB GS0 GS3 GS7 RGB RGB GS59 GS63 .... LD13708-6 6-2. Backlight driving The backlight system is an edge-lighting type with single CCFT (Cold Cathode Fluorescent Tube). The characteristics of single lamp are shown in the following table. Ta=25℃ Parameter Symbol Min. Typ. Max. Unit Remark Lamp current IL 3.5 6.0 7.0 mArms 【Note1】 2.8 Lamp power consumption PL - - W 【Note2】 Lamp frequency FL 40 60 70 KHz 【Note3】 Kick-off voltage Vs 1000 Vrms Ta=25℃ - - 1300 Vrms Ta =0℃【Note4】 - - Lamp life time LL 50000 hour 【Note5】IL=6.0mA - - LL 30000 hour 【Note5】IL=7.0mA - - 【Note1】 Lamp current is measured with current meter for high frequency as shown below. 1 Module 3 1 3 A ~ Inverter A ~ * 3pin is V LOW 【Note2】 At the condition of YL =350cd/m2 【Note3】 Lamp frequency may produce interference with horizontal synchronous frequency,and this may cause beat on the display. Therefore lamp frequency shall be detached as much as possible from the horizontal synchronous frequency and from the harmonics of horizontal synchronous to avoid interference. 【Note4】The open output voltage of the inverter shall be maintained for more than 1sec; otherwise the lamp may not be turned on. 【Note5】Since lamp is consumables, the life time written above is referencial value and it is not guaranteed in this specification sheet by SHARP. Lamp life time is defined that it applied either ① or ② under this condition (Continuous turning on at Ta=25℃, IL=6/7mArms) ① Brightness becomes 50% of the original value under standard condition. ② Kick-off voltage at Ta=0℃ exceeds maximum value,(TBD) Vrms. In case of operating under lower temp environment, the lamp exhaustion is accelerated and the brightness becomes lower. (Continuous operating under for around 1 month under lower temp condition may reduce the brightness to half of the original brightness.) In case of such usage under lower temp environment, periodical lamp exchange is recommended. 【Note6】The performance of the backlight, for example life time or brightness, is much influenced by the characteristics of the DC-AC inverter for the lamp. When you design or order the inverter, please make sure that a poor lighting caused by the mismatch of the backlight and the inverter (miss-lighting,flicker, etc.) never occur. when you confirm it, the module should be operated in the same condition as it is installed in your instrument. 【Note7】 It is required to have the inverter designed so that to allow the impedance deviation of the two CCFT lamps and the capacity deviation of barast capacitor. LD13708-7 7. Timing Characteristics of input signals Timing diagrams of input signal are shown in Fig.2 - ①~③ . 7-1. Timing characteristics Parameter Clock Data Horizontal Symbol Mode Typ. Max. Unit Frequency 1/Tc all - 25.18 28.33 MHz High time Tch 〃 5 - - ns Low time Tcl 〃 10 - - ns Setup time Tds 〃 5 - - ns Hold time Tdh 〃 10 - - ns Cycle TH 〃 30.00 31.78 - μs 〃 770 800 900 clock sync. signal Vertical Min. Pulse width THp 〃 2 96 200 clock Cycle TV 480 515 525 560 line 400 445 449 480 line 350 447 449 510 line sync. signal Pulsewidth TVp all 1 - 34 line Horizontal display period THd 〃 640 640 640 clock Hsync-Clock THc 〃 10 - Tc-10 ns TVh 〃 0 - Remark phase difference Hsync-Vsync TH-THp clock phase difference Note) In case of lower frequency, the deterioration of display quality, flicker etc.,may be occurred. 7-2. Horizontal display position The horizontal display position is determined by ENAB signal and the input data corresponding to the rising edge of ENAB signal is displayed at the left end of the active area. Parameter symbol Min. Typ. Max. Unit Enable signal Setup time Tes 5 - Tc-10 ns Pulse width Tep 2 640 640 clock THe 44 - TH-664 clock Hsync-Enable signal Remark phase difference Note) When ENAB is fixed "Low", the display starts from the data of C104(clock) as shown in Fig.2-①~③. Be careful that the module does not work when ENAB is fixed "High". When the phase difference is below 104 clock, keep the “High level of ENAB is signal longer Than 104-The. If it will not be keeped, the display starts from the data of C104(clock). LD13708-8 7-3. Vertical display position The vertical display position is automatically centered in the active area at each mode of VGA ,480-,400-,and 350-line mode . Each mode is selected depending on the polarity of the synchronous signals described in 4-1(Note1). In each mode ,the data of TVn is displayed at the top line of the active area. And the display position will be centered on the screen like the following figure when the period of vertical synchronous signal,TV,is typical value. In 400-,and 350-line mode,the data in the vertical data invalid period is also displayed, So ,inputting all data "0" is recommended during vertical data invalid period. ENAB signal has no relation to the vertical display position. Mode V-data start(TVs) V-data V-display start(TVn) V-display period Unit Remark period(TVd) 480 34 480 34 480 line 400 34 400 443-TV 480 line 350 61 350 445-TV 480 line data invalid period 40lines data period data period 400lines data invalid period 65lines data invalid period 350lines 65lines data invalid period 40lines 400 lines mode (TV=449) 350 lines mode (TV=449) 7-4. Input Data Signals and Display Position on the screen Display position of input data (480 lines mode) (H,V) D1,DH1 D2,DH1 D1,DH2 D2,DH2 D3,DH1 UP D640,DH1 D1,DH3 R D1,DH480 G B D640,DH480 TH THp THc * Only when enable terminal is fixed "Low" c c V 3 . 0 C1* C2* C104* Number of clock Tds Tdh Number of H-data c c V 7 . 0 Horizontal invalid da ta period D1 D2 THe D3 D639 c c V 3 . 0 Data signal (R0~R5,G0~G5, B0~B5) Tc Tch Tcl c c V 7 . 0 c c V 3 . 0 c c V 3 . 0 c c V 3 . 0 c c V 3 . 0 Clock signal (CK) c c V 3 . 0 c c V 7 . 0 c c V 3 . 0 c c V 3 . 0 Horizontal sync. signal (Hsync) D640 Horizontal invalid da ta period THd c c V 3 . 0 c c V 7 . 0 Tes Data enable signal (ENAB) Tep TV c c V 7 . 0 TVp c c V 3 . 0 c c V 3 . 0 Vertical sync. signal (Vsync) TVh c c V 7 . 0 2 34 TVs Data signal (R0~R5,G0~G5, B0~B5) TVd Vertical invalid data period DH1 DH2 DH3 DH479 DH480 Vertical invalid data period Number of V-data line Fig2-1 Input signal Fig 2-1 Input signal waveforms(480 waveforms (480line line mmode) LD13708-9 1 e n i l f o r e b m u N Horizontal sync. signal (Hsync) TH THp c c V 3 . 0 c c V 7 . 0 c c V 3 . 0 c c V 3 . 0 Horizontal sync. signal (Hsync) THc C2* c c V 3 . 0 c c V 3 . 0 c c V 3 . 0 c c V 3 . 0 C104* k c o l c f o r e b m u N C1* Tds Tdh Number of H-data c c V 7 . 0 D1 Horizontal data invalid period D2 THe D3 D639 c c V 3 . 0 Data signal (R0~R5,G0~G5, B0~B5) c c V 7 . 0 * Only when enable terminal (ENAB) is fixed Clock signal (CK) Tc Tch Tcl Horizontal data invalid period D640 THd c c V 7 . 0 c c V 3 . 0 Tes Data enable signal (ENAB) Tep TV c c V 7 . 0 c c V 7 . 0 c c V 3 . 0 Vertical sync. signal (Vsync) TVp TVh c c V 7 . 0 1 2 34 Number of line TVs Data signal (R0~R5,G0~G5, B0~B5) Vertical invalid data period TVd DH1 DH2 DH3 DH399 DH400 Vertical invalid data period e n i l a t a d V f o r e b m u N Fig2-2 Input waveforms(400 line Fig.2-2 Inputsignal signal waveforms (400 linemode) LD13708-10 Horizontal sync. signal (Hsync) TH c c V 7 . 0 c c V 7 . 0 c c V 7 . 0 c c V 3 . 0 Horizontal sync. signal (Hsync) THp THc * Only when enable terminal (ENAB) fixed to "Low c c V 3 . 0 C2* k c o l c f o r e b m u N C1* C104* Tds Tdh Number of H-data c c V 7 . 0 Horizontal invalid data period D1 D2 THe D3 D639 c c V 3 . 0 Data signal (R0~R5,G0~G5, B0~B5) c c V 7 . 0 c c V 3 . 0 c c V 3 . 0 c c V 3 . 0 Clock signal (CK) Tc Tch Tcl Horizontal invalid data period D640 THd c c V 7 . 0 c c V 3 . 0 Tes Data enable signal (ENAB) Tep TV c c V 7 . 0 TVp c c V 3 . 0 c c V 3 . 0 Vertical sync. signal (Vsync) TVh c c V 3 . 0 Horizontal sync. signal (Hsync) 1 2 61 TVs Vertical invalid data period TVd DH1 DH2 DH3 DH349 DH350 Vertical invalid data period Number of V-data line Fig.2-3 Input signal waveforms (350 line mod Fig2-3 Input signal waveforms(350 line mode) LD13708-11 LD13708-11 Data signal (R0~R5,G0~G5, B0~B5) Number of li LD13708-12 8. Input Signals, Basic Display Colors and Gray Scale of Each Color Colors & Gray scale Data signal Gray RA0 RA1 RA2 RA3 RA4 RA5 GA0 GA1 GA2 GA3 GA4 GA5 BA0 BA1 BA2 BA3 BA4 BA5 Scale RB0 RB1 RB2 RB3 RB4 RB5 GB0 GB1 GB2 GB3 GB4 GB5 BB0 BB1 BB2 BB3 BB4 BB5 Black - 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Blue - 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 Green - 0 0 0 0 0 0 1 1 1 1 1 1 0 0 0 0 0 0 Cyan - 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 1 1 1 Red - 1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 Magenta - 1 1 1 1 1 1 0 0 0 0 0 0 1 1 1 1 1 1 Yellow - 1 1 1 1 1 1 1 1 1 1 1 1 0 0 0 0 0 0 White - 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Black GS0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 × GS1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Darker GS2 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 × È È È È Ø È È È È Brighter GS61 1 0 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 Ø GS62 0 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 Red GS63 1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 Black GS0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 × GS1 0 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 Darker GS2 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 × È È È È Ø È È È È Brighter GS61 0 0 0 0 0 0 1 0 1 1 1 1 0 0 0 0 0 0 Ø GS62 0 0 0 0 0 0 0 1 1 1 1 1 0 0 0 0 0 0 Green GS63 0 0 0 0 0 0 1 1 1 1 1 1 0 0 0 0 0 0 Black GS0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 × GS1 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 Darker GS2 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 × È È È È Ø È È È È Brighter GS61 0 0 0 0 0 0 0 0 0 0 0 0 1 0 1 1 1 1 Ø GS62 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 Blue GS63 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 r o l o C c i s a B d e R f o e l a c S y a r G n e e r G f o e l a c S y a r G e u l B f o e l a c S y a r G 0 :Low level voltage, 1 : High level voltage Each basic color can be displayed in 64 gray scales from 6 bit data signals. According to the combination of total 18 bit LD13708-13 data signals, the 262,144-color display can be achieved on the screen. Ta=25℃, Vcc=+5V 9. Optical Characteristics Parameter Viewing Angle Symbol Condition Min Typ Max Unit Remark Horizontal θ21,θ22 CR≧10 60 70 - Deg. 【Note1,4】 θ11 35 40 - Deg. θ12 55 70 - Deg. θ=0° 150 - - - Best Viewing - 300 - - - 20 - ms ms Vertical Range Contrast ratio CR 【Note2,4】 Angle Response Rise τr Time Decay τd - 40 - Chromaticity of x - 0.313 - White y - 0.329 - Luminance of white YL - 350 - cd/m2 White Unifomity δW - - 1.45 - 【Note5】 - 45 - Deg. 【Note1】 - 35 - Deg. - 35 - Deg. Viewing Horizontal θ21,θ22 50% of 【Note3,4】 【Note4】 the Angle range as a Brightness Definition ※The θ=0° Vertical θ11 θ12 maximum brightness measurement shall be executed 30 minutes after lighting at rating. (typical condition:IL=6.0mArms) The optical characteristics shall be measured in a dark room or equivalent state with the method shown in Fig.3 below. Photodetector (BM-5A:TOPCON) Field=2° 400mm TFT-LCD module LCD panel Center of the screen Fig.3 Optical characteristics measurement method LD13708-14 【Note1】Definitions of viewing angle range: 【Note2】Definition of contrast ratio: The contrast ratio is defined as the following. Luminance (brightness) with all pixels white Contrast Ratio (CR) = Luminance (brightness) with all pixels black 【Note3】Definition of response time: The response time is defined as the following figure and shall be measured by switching the input signal for "black" and "white" . 【Note4】This shall be measured at center of the screen. 【Note5】Definition of white uniformity: White uniformity is defined as the following with five measurements 160 320 480 pixel (A~E). A D 240 C B δw= Maximum Luminance of five points (brightness) Minimum Luminance of five points (brightness) 120 E 360 pixel LD13708-15 10. Display Quantity The display quality of the color TFT-LCD module shall be in compliance with the Incoming Inspection Standard. 11.Handling Precautions a) Be sure to turn off the power supply when inserting or disconnecting the cable. b) Be sure to design the cabinet so that the module can be installed without any extra stress such as warp or twist. c) Since the front polarizer is easily damaged, pay attention not to scratch it. d) Wipe off water drop immediately. Long contact with water may cause discoloration or spots. e) When the panel surface is soiled, wipe it with absorbent cotton or other soft cloth. f) Since the panel is made of glass, it may break or crack if dropped or bumped on hard surface. Handle with care. g) Since CMOS LSI is used in this module, take care of static electricity and injure the human earth when handling. h) Observe all other precautionary requirements in handling components. i) This module has its circuitry PCBs on the rear side and should be carefully handled in order not to be stressed. j) The polarizer surface on the panel is treated with Anti-Glare for low reflection. In case of attaching protective board over the LCD. Be careful about the optical interface fringe etc. Which degrades display quality. k) Connect GND to 4 place of mounting holes to stabilize against EMI and external noise. l) There are high voltage portions on the backlight and very dangerous. Careless touch may lead to electrical shock. When exchange lamps or service. Turn off the power without tail. m) Be sure not to apply tensile stress to the lamp lead cable. 12.Packing form Product country JAPAN Piling number of cartons 7(Max) Packing quantity in one carton 20 Carton size 494(W)×326(D)×433(H) [mm] Total mass of one carton filled 15.6kg with full modules Packing form is shown Fig.1-2 LD13708-16 13.Reliability test items No. Test item Conditions 1 High temperature storage test Ta=70℃ 240h 2 Low temperature storage test Ta=-30℃ 240h 3 High temperature Ta=40℃ ; 95%RH 240h & high humidity operation test (No condensation) 4 High temperature operation test Ta=65℃ 5 Low temperature operation test Ta=-10℃ 6 Vibration test Frequency: 10~57Hz/Vibration width (one side):0.075mm 240h 240h : 58~500Hz/Gravity:9.8m/s2 (non- operating) Sweep time : 11 minutes Test period : 3 hours (1 hour for each direction of X,Y,Z) 7 Shock test Max. gravity : 490m/s2 (non- operating) Pulse width : 11ms, half sine wave Direction : ±X,±Y,±Z once for each direction. 【Result Evaluation Criteria】 Under the display quality test conditions with normal operation state, these shall be no change which may affect practical display function. 14.Others P R A H S 1) Lot No Label: Model No. LQ104V1DG51 07 XXXXXX_ MADE IN □□□□□ Lot No. JAPAN 2) Adjusting volume have been set optimally before shipment, so do not change any adjusted value. If adjusted value is changed, the specification may not be satisfied. 3) Disassembling the module can cause permanent damage and should be strictly avoided. 4) Please be careful since image retention may occur when a fixed pattern is displayed for a long time 5) Do not use LCD module in the atmosphere of corrosive gases, such as sulfide gas or chlorine gases. Polarizer may deteriorated or cause chemical reaction that can lead to short circuits at the terminal Points. Do not use the material, which compounds contain sulfide or chlorine articles in the vicinity of LCD module. At high temperature, these compounds produce corrosive gases. 6) If any problem occurs in relation to the description of this specification , it shall be resolved through discussion with spirit of cooperation. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. Suggested applications (if any) are for standard use; See Important Restrictions for limitations on special applications. See Limited Warranty for SHARP’s product warranty. The Limited Warranty is in lieu, and exclusive of, all other warranties, express or implied. ALL EXPRESS AND IMPLIED WARRANTIES, INCLUDING THE WARRANTIES OF MERCHANTABILITY, FITNESS FOR USE AND FITNESS FOR A PARTICULAR PURPOSE, ARE SPECIFICALLY EXCLUDED. In no event will SHARP be liable, or in any way responsible, for any incidental or consequential economic or property damage. NORTH AMERICA EUROPE JAPAN SHARP Microelectronics of the Americas 5700 NW Pacific Rim Blvd. Camas, WA 98607, U.S.A. Phone: (1) 360-834-2500 Fax: (1) 360-834-8903 Fast Info: (1) 800-833-9437 www.sharpsma.com SHARP Microelectronics Europe Division of Sharp Electronics (Europe) GmbH Sonninstrasse 3 20097 Hamburg, Germany Phone: (49) 40-2376-2286 Fax: (49) 40-2376-2232 www.sharpsme.com SHARP Corporation Electronic Components & Devices 22-22 Nagaike-cho, Abeno-Ku Osaka 545-8522, Japan Phone: (81) 6-6621-1221 Fax: (81) 6117-725300/6117-725301 www.sharp-world.com TAIWAN SINGAPORE KOREA SHARP Electronic Components (Taiwan) Corporation 8F-A, No. 16, Sec. 4, Nanking E. Rd. Taipei, Taiwan, Republic of China Phone: (886) 2-2577-7341 Fax: (886) 2-2577-7326/2-2577-7328 SHARP Electronics (Singapore) PTE., Ltd. 438A, Alexandra Road, #05-01/02 Alexandra Technopark, Singapore 119967 Phone: (65) 271-3566 Fax: (65) 271-3855 SHARP Electronic Components (Korea) Corporation RM 501 Geosung B/D, 541 Dohwa-dong, Mapo-ku Seoul 121-701, Korea Phone: (82) 2-711-5813 ~ 8 Fax: (82) 2-711-5819 CHINA HONG KONG SHARP Microelectronics of China (Shanghai) Co., Ltd. 28 Xin Jin Qiao Road King Tower 16F Pudong Shanghai, 201206 P.R. China Phone: (86) 21-5854-7710/21-5834-6056 Fax: (86) 21-5854-4340/21-5834-6057 Head Office: No. 360, Bashen Road, Xin Development Bldg. 22 Waigaoqiao Free Trade Zone Shanghai 200131 P.R. China Email: [email protected] SHARP-ROXY (Hong Kong) Ltd. 3rd Business Division, 17/F, Admiralty Centre, Tower 1 18 Harcourt Road, Hong Kong Phone: (852) 28229311 Fax: (852) 28660779 www.sharp.com.hk Shenzhen Representative Office: Room 13B1, Tower C, Electronics Science & Technology Building Shen Nan Zhong Road Shenzhen, P.R. China Phone: (86) 755-3273731 Fax: (86) 755-3273735