F2500RU Series 4:1 Input 25W - 30W Single & Dual Output DC/DC Converters Electrical Specifications Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Key Features: • 25W-30W Output Power • 4:1 Input Voltage Range • 1,500 VDC Isolation • Meets EN55022 Class A • Compact 2 x 1.6 In. Case • Single & Dual Outputs • Remote ON/OFF • Industry Standard Pin-Out Input Parameter Input Start Voltage Under Voltage Shutdown Input Filter Reverse Polarity Input Current Short Circuit Input Power Conditions Min. Typ. Max. 24 VDC Input 9.4 9.7 10.0 48 VDC Input 17.0 17.5 18.0 24 VDC Input 9.0 9.3 9.5 48 VDC Input 16.0 16.5 17.0 (Pi) Filter (Meets EN55022 Class “A”) 2.0 4,500 Units VDC VDC A mW Output Parameter Output Voltage Accuracy Output Voltage Balance Line Regulation Load Regulation Ripple & Noise (20 MHz) (Note 1) Ripple & Noise (20 MHz) Output Power Protection Transient Recovery Time (Note 2) Transient Response Deviation Temperature Coefficient Output Short Circuit Conditions Min. Dual Output , Balanced Loads For Vin Min to Max Iout = 50% to 100% Typ. ±0.5 ±0.5 ±0.2 ±0.3 55 Max. ±1.0 ±2.0 ±0.5 ±1.0 80 100 180 300 ±4.0 ±0.02 Units % % % % mV P - P mV P - P % µSec % %/°C Typ. Max. 1,200 330 112 1,500 360 117 Units VDC VDC M⍀ pF kHz °C Over Line, Load & Temp. 120 150 ±2.0 ±0.01 Continuous (Autorecovery) 25% Load Step Change General Parameter Isolation Voltage Isolation Voltage Test Isolation Resistance Isolation Capacitance Switching Frequency Over Temperature Protection Remote On/Off (Note 3) Parameter Supply On Supply Off Standby Input Current Control Common Conditions 60 Seconds Flash Tested For 1 Second 500 VDC 100 kHz, 1V Case Temperature Conditions Min. 1,500 1,650 1,000 290 107 Min. 2.5 -1.0 Typ. Max. Units 100.0 VDC 1.0 VDC 5 mA Referenced to Negative Input (pin 2) Environmental MicroPower Direct 292 Page Street Suite D Stoughton, MA 02072 USA Parameter Operating Temperature Range Operating Temperature Range Storage Temperature Range Cooling Humidity Physical Case Size Case Material Weight Conditions Min. Typ. -40 -40 -50 Free Air Convection RH, Non-condensing Ambient Case Max. +50 +105 +125 Units °C °C °C 95 % 2.0 x 1.6 x 0.37 Inches (50.8 x 40.6 x 9.3 mm) Metal with Non-Conductive Base 1.75 Oz (48g) Reliability Specifications T: (781) 344-8226 F: (781) 344-8481 E: [email protected] W: www.micropowerdirect.com Parameter MTBF Conditions MIL HDBK 217F, 25°C, Gnd Benign Min. 1,000 Typ. Max. Units kHours Conditions 24 VDC Input 48 VDC Input 1.5 mm From Case For 10 Sec All Models Min. -0.7 -0.7 Typ. Max. 50.0 100.0 260 5,500 Units Absolute Maximum Ratings Parameter Input Voltage Surge (1 Sec) Lead Temperature Internal Power Dissipation Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings. www.micropowerdirect.com VDC °C mW www.micropowerdirect.com Model Selection Guide Input Model Number F2501RU F2502RU F2503RU F2504RU F2505RU F2506RU F2511RU F2512RU F2513RU F2514RU F2515RU F2516RU Output Over Voltage Efficiency Voltage Current Current Protection (%, Typ) Nominal Range Full-Load No-Load (VDC) (mA, Max) (mA, Min) (VDC) 24 10.0 - 40.0 922 20 3.3 5,500 400.0 3.9 82 24 10.0 - 40.0 1,225 20 5.0 5,000 350.0 6.8 85 24 10.0 - 40.0 1,404 20 12.0 2,500 166.0 15.0 89 24 10.0 - 40.0 1,404 20 15.0 2,000 133.0 18.0 89 24 10.0 - 40.0 1,404 20 ±12.0 ±1,250 ±83.0 ±15.0 89 24 10.0 - 40.0 1,404 20 ±15.0 ±1,000 ±65.0 ±18.0 89 48 18.0 - 75.0 461 10 3.3 5,500 400.0 3.9 82 48 18.0 - 75.0 613 10 5.0 5,000 350.0 6.8 85 48 18.0 - 75.0 702 10 12.0 2,500 166.0 15.0 89 48 18.0 - 75.0 702 10 15.0 2,000 133.0 18.0 89 48 18.0 - 75.0 702 10 ±12.0 ±1,250 ±83.0 ±15.0 89 48 18.0 - 75.0 702 10 ±15.0 ±1,000 ±65.0 ±18.0 89 Voltage (VDC) Current (mA) Notes: 1. When measuring output ripple, it is recommended that an external 1.0 µF ceramic capacitor be placed from the +Vout pin to the -Vout pin for single output units and from each output to common for dual output units. For noise sensitive applications, the use of 4.7 µF capacitors will reduce the output ripple. The maximum rms value of the output ripple is 10 mV. 2. Transient recovery is measured to within a 1% error band for a load step change of 75% to 100%. 3. The maximum sink current at the on/off pin (pin 4) during a logic low is 100 µA. The maximum allowable leakage current of a switch connected to the on/off pin (Pin 4) at logic high (2.5V to 100V) is 5 µA. If the on/ off pin (Pin 4) is left open, the unit operates. If it is grounded, the unit will shut off. 4. Operation at no-load will not damage these units. However, they may not meet all specifications. 5. Dual output units may be connected to provide a 24 VDC or 30 VDC output. To do this, connect the load across the positive (+Vout) and negative (-Vout) outputs and float the output common. 6. The converter should be connected to a low ac-impedance source. An input source with a highly inductive impedance may affect the stability of the converter. In applications where the converter output loading is high and input power is supplied over long lines, it may be necessary to use a capacitor on the input to insure start-up. In this case, it is recommended that a low Equivalent Series Resistance (ESR <1.0⍀ at 100 kHz) capacitor be mounted close to the converter. A 33 µF is recommended for 24V input models and a 10 µF for 48V units. 7. It is recommended that a fuse be used on the input of a power supply for protection. See the table above for the correct rating. External Trim A simple external circuit may be used to adjust the converter output. To adjust the output DOWN, connect a 5%, 3W resistor between the plus output pin and the Vout trim pin. To adjust the output UP, connect a 5%, 3W resistor between the minus output pin and the Vout trim pin. To calculate the correct resistor value use: UP Radj = (33 x Vout) - (30 x Vadj) Vadj - Vout Down Radj = (36.667 x Vout) - (33 x Vout) Vout - Vadj For UP/Down trimming capability, connect a 10 kW potentiometer between the plus and minus outputs with the wiper arm connected to the Vout trim pin. Capacitive Load (µF Max) 1,000 1,000 1,000 1,000 ±330 ±330 1,000 1,000 1,000 1,000 ±330 ±330 Fuse Rating Slow-Blow (mA) 5,000 5,000 5,000 5,000 5,000 5,000 3,000 3,000 3,000 3,000 3,000 3,000 For Heatsink Option, add suffix “H” to model number (i.e. F2503RU-H) Mechanical Dimensions Mechanical Notes: Pin Connections Pin Single Dual 1 +Vin +Vin 2 -Vin -Vin 4 ON/OFF ON/OFF 5 No Pin +Vout Pin Single 6 +Vout 7 -Vout 8 Trim Dual Comm. -Vout Trim • All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.01 (±0.25) Heatsink Dimensions (Optional) Derating Curves Heatsink Notes: MicroPower Direct • Use of the heatsink will extend the units operating temperature range by approximately 10°C. • The heatsink is black anodized aluminum. We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]