DKLP-1 Suppression Chokes https://www.schurter.com /PG81_82 Compensated High Inductance Choke, 1-phase Approvals and Compliances Description - Applications Current compensated choke 1-phase choke Flexible wire Flange for mounting onto printed circuit board Fully potted resign - Placed in front of frequency converter Stepper motor drives UPS-systems Inverter Weblinks pdf datasheet, html-datasheet, General Product Information, DistributorStock-Check, Detailed request for product Technical Data Rated voltage ␣ Rated Current Rated inductance Power Operating Frequency Terminal Type Weight Material: Housing Sealing Compound up to 540 VAC up to 760 VDC 4 - 20 A @ Ta 40 °C 14 - 60 mH, Tol. -30% +50% 50 - 400 Hz Flexible wire 145 - 512 g UL 94V-0 UL 94V-0 Test Voltage Isolation Voltage Climatic Category Allowable Operation Temp. 2.5 kV, 50 Hz, 2 sec, winding to winding 2.5 kV eff., 50 Hz, 2 sec, winding to ambient 25/100/21 acc. to IEC 60068-1 -25 °C to 100 °C Approvals and Compliances Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in Details about Approvals Approvals The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products. Approval Reference Type: DKLP Approval Logo Certificates Certification Body Description UL Approvals UL UL File Number: Design Standard Description Designed for applications acc. IEC/UL 60950 IEC 60950-1 includes the basic requirements for the safety of information technologyequipment. Application standards Application standards where the product can be used Organization EMC Products 1 DKLP-1 Suppression Chokes https://www.schurter.com /PG81_82 Compliances The product complies with following Guide Lines Details Initiator Description CE declaration of conformity SCHURTER AG The CE marking declares that the product complies with the applicable requirements laid down in the harmonisation of Community legislation on its affixing in accordance with EU Regulation 765/2008. RoHS SCHURTER AG EU Directive RoHS 2011/65/EU China RoHS SCHURTER AG The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March 2007. It is similar to the EU directive RoHS. REACH SCHURTER AG On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration, Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as "REACH") entered into force. Dimension [mm] Case 29-2W Case 31-2W 30.8 48 48 80 4.3 Case 33-2W 70 120 230 10...20 8 100 100 120 65 10...20 3.1 5.25 2 EMC Products 50.8 80 150 5.8 38.2 38.2 65 Identification 6.8 230 10...20 DKLP-1 Suppression Chokes https://www.schurter.com /PG81_82 Impedance curves DKLP-0229-xxxx DKLP-023x-xxxx z [Ω] 1M z [Ω] 1M 100k 100k 4A 4A 6A 10k 10k 1k 1k 100 100 10 5A 7A 20A 10 10k 100k 1M 10M f [Hz] 10k 100k 1M 10M f [Hz] All Variants In [A] Ln [mH] Rcu [mΩ] Powerloss [W] fRES [MHz] Copper ø [mm] Weight [g] Housings Packing unit [pcs.] Order Number 4 30 96 3 0.2 0.8 145 g 29-2W 12 DKLP-0229-0430 6 14 46 3.3 0.3 1 145 g 29-2W 12 DKLP-0229-0614 4 60 250 8 0.1 0.71 477 g 31-2W 2 DKLP-0231-0460 5 40 126 6.3 0.048 0.9 505 g 31-2W 2 DKLP-0231-0540 7 20 62 6 0.18 1.12 512 g 31-2W 2 DKLP-0231-0720 20 12 19 15.2 0.16 1.8 180 g 33-2W 1 DKLP-0233-2012 30.11.2017 Availability for all products can be searched real-time:https://www.schurter.com/en/Stock-Check/Stock-Check-SCHURTER The specifications, descriptions and illustrations indicated in this document are based on current information. All content is subject to modifications and amendments. Information furnished is believed to be accurate and reliable. However, users should independently evaluate the suitability and test each product selected for their own applications. EMC Products 3