NI NI3110 Rugged, high-performance, fanless, industrial controller Datasheet

Industrial Controllers
NI 3100, NI 3110 NEW!
◾◾ Rugged, high-performance, fanless,
industrial controllers
◾◾ Processor options
◾◾ NI 3100 – 1.06 GHz Intel Celeron M
◾◾ NI 3110 – 1.66 GHz Intel Core Duo
◾◾ 80 GB SATA HDD with Windows XP
and 1 GB DDR 2 memory
◾◾ 10 to 30 VDC power input
◾◾ Panel mount footprint,
110 by 200 by 220 cm
(4.3 by 7.9 by 8.66 in.)
◾◾ Weight without PCI board:
3.63 kg (8.0 lb)
Connectivity
◾◾ 4 Hi-Speed USB
◾◾ 2 gigabit Ethernet
◾◾ 1 PCI or PCI Express slot
◾◾ 1 MXI Express connector
◾◾ 1 RS232 port
Mounting Options
◾◾ Panel mounting holes included
◾◾ Optional wall mounting kit
Description
Industrial controller
Model Number
NI 3100
Processor
1.06 GHz Intel Celeron M
OS
Windows XP
Hard Drive Options
80 GB SATA HDD
Memory
1 GB DDR2
Form Factor
Panel mount
Expansion Capabilities
1 PCI or PCI Express board
Dual-core industrial
controller
NI 3110
1.66 GHz Intel Core Duo
Windows XP
80 GB SATA HDD
1 GB DDR2
Panel mount
1 PCI or PCI Express board
Table 1. NI Industrial Controller Specifications
Overview
RS232 Serial
NI 3100 and NI 3110 industrial controllers are rugged, fanless, industrial PCs that
feature a wide range of expansion capabilities to other National Instruments
platforms. The NI 3100 incorporates a 1.06 GHz Intel Celeron M processor , and
the NI 3110 features a 1.66 GHz Intel Core Duo processor. NI ships both systems
(2) Gigabit
Ethernet
(4) Hi-Speed USB
(1) MXI Express
External Flash
10 to 30 VDC
Power
DVI
with 1 GB DDR2 memory, an 80 GB or larger SATA hard-disk drive (HDD)., and
Windows XP (see Table 1).
You can use high-performance NI industrial controllers to deploy NI LabVIEW
software in a wide range of applications. These controllers also feature several
standard PC connectivity options (see Figure 1).
◾◾ Four Hi-Speed USB ports
◾◾ Two gigabit Ethernet ports
◾◾ One PCI or PCI Express slot
◾◾ One integrated MXI Express x1 controller
◾◾ One CompactFlash memory card
◾◾ Dual monitor support with one DVI; splitter cable to analog VGA and DVI
provided
(1) PCI or PCI Express Slot
Figure 1. NI Industrial Controller Connectivity Options
These connectivity options provide expansion to a wide range of NI platforms
including PXI, NI CompactDAQ, CompactRIO, Compact FieldPoint, USB data
acquisition (DAQ), and NI plug-in DAQ hardware.
Supported
Platforms
Industrial controller
with Windows XP
PXI
NI CompactDAQ
USB DAQ
PCI or PCI Express
Plug-In
MXI Express
Hi-Speed USB
Hi-Speed
USB
<10 W half-length
plug-in card
Table 2. Supported Industrial Controller Expansion I/O
Industrial Controllers
PCI and PCI Express Support and Operating Temperature
NI 31xx industrial controllers work with half-length PCI or PCI Express boards that dissipate less than 10 W and have been thermally tested by NI in the fanless
configuration. Figure 2 shows the dimensions of a half-length and full-length PCI board.
Full-Length PCI
Half-Length PCI
107 mm
106.68 mm
312 mm
175.26 mm or less
Figure 2. Full-Length and Half-Length PCI Board Dimensions
NI 31xx industrial controllers offer a 0 to 50 °C operating temperature without a PCI board installed. The operating temperature with a PCI or PCI Express board
installed in the peripheral slot depends on the specifications of the PCI/PCI Express board and heat dissipation across the board. With a PCI or PCI Express board that
dissipates less than 10 W of heat, the operating temperature is 0 to 45 °C. For a complete list of PCI and PCI Express boards supported by National Instruments,
visit ni.com/info and enter exfnrw.
MXI Express
PXI Remote
NI 3100 and NI 3110
VGA USB
Touch Screen
USB
4 USB Ports
NI FPI-1015
Flat Panel
Touch Screen
NI CompactDAQ and USB
PCI or PCI
Express
1 Slot
Figure 3. Industrial Controller and Expansion I/O Architecture Options
BUY ONLINE at ni.com or C ALL 800 813 36 93 (U.S.)
2
Industrial Controllers
Ordering Information
NI 3100............................................................................................780309-01
NI 3110............................................................................................780310-01
PS-5 power supply..........................................................................778805-90
BUY NOW
For complete product specifications, pricing,and accessory information,
call 800 813 3693 (U.S.) or go to ni.com/pac.
BUY ONLINE at ni.com or C ALL 800 813 36 93 (U.S.)
3
Industrial Controllers
Specifications
Note: For UL and other safety certifications, refer to the product label or visit
ni.com/certification, search by model number or product line, and click the
Electrical
appropriate link in the Certification column.
Voltage...................................................
10 to 30 VDC
Power.....................................................
40 W maximum (no PCI board installed)
Physical
Electromagnetic Compatibility
This product is designed to meet the requirements of the following standards of
Unit dimensions.....................................
110 by 200 by 220 cm
EMC for electrical equipment for measurement, control, and laboratory use:
◾◾ EN 61326 (IEC 61326): Class A emissions; Basic immunity
(4.3 by 7.9 by 8.66 in.)
◾◾ EN 55011 (CISPR 11): Group 1, Class A emissions
Weight....................................................
3.63 kg (8.0 lb) maximum
◾◾ AS/NZS CISPR 11: Group 1, Class A emissions
(no PCI board installed)
◾◾ FCC 47 CFR Part 15B: Class A emissions
◾◾ ICES-001: Class A emissions
Environment
Maximum altitude..................................
2,000 m (at 25 °C ambient temperature)
Pollution degree.....................................
2
Indoor use only.
Note: For EMC compliance, operate this device according to
product documentation.
CE Compliance
This product meets the essential requirements of applicable European Directives,
Operating Environment
No PCI board installed...........................
0 to 50 °C
as amended for CE marking, as follows:
◾◾ 2006/95/EC; Low-Voltage Directive (safety)
PCI board installed (10 W max).............
0 to 45 °C
◾◾ 2004/108/EC; Electromagnetic Compatibility Directive (EMC)
Note: Thermal performance is orientation-dependent and was tested with the
Note: Refer to the Declaration of Conformity (DoC) for this product for any
heat sink at the top.
additional regulatory compliance information. To obtain the DoC for this product,
Storage Environment
visit ni.com/certification, search by model number or product line, and click
the appropriate link in the Certification column.
Ambient temperature.............................
-40 to 70 °C (tested in accordance with
IEC-60068-2-1 and IEC-60068-2-2)
Online Product Certification
Relative humidity...................................
5 to 95% noncondensing (tested in
Refer to the product Declaration of Conformity (DoC) for additional regulatory
accordance with IEC-60068-2-56)
compliance information. To obtain product certifications and the DoC for this
product, visit ni.com/certification, search by model number or product line,
Shock and Vibration
and click the appropriate link in the Certification column.
Functional shock....................................
30 g peak, 11 ms pulse
(tested in accordance with
Environmental Management
IEC-60068-2-27; test profile developed
NI is committed to designing and manufacturing products in an environmentally
in accordance with MIL-PRF-28800F)
responsible manner. NI recognizes that eliminating certain hazardous substances
from our products is beneficial to the environment and to NI customers.
Random Vibration
Operating vibration................................
5 to 500 Hz, 0.31 grms
Nonoperating vibration..........................
5 to 500 Hz, 2.4 grms
(tested in accordance with
IEC-60068-2-64; nonoperating test
profile exceeds the requirements of
IL-PRF-28800F, Class 3)
Safety and Compliance
Safety
This product is designed to meet the requirements of the following standards of
For additional environmental information, refer to the NI and the Environment
Web page at ni.com/environment. This page contains the environmental
regulations and directives with which NI complies, as well as other
environmental information not included in this document.
Waste Electrical and Electronic Equipment (WEEE)
EU Customers: At the end of their life cycle, all products must be
sent to a WEEE recycling center. For more information about WEEE
recycling centers and National Instruments WEEE initiatives,
visit ni.com/environment/weee.htm.
safety for electrical equipment for measurement, control, and laboratory use:
◾◾ IEC 61010-1, EN 61010-1
◾◾ UL 61010-1, CSA 61010-1
BUY ONLINE at ni.com or C ALL 800 813 36 93 (U.S.)
4
NI Services and Support
your needs around the globe and through
PL
AN
MA
IN
NI has the services and support to meet
IN
TA
the application life cycle – from planning
and development through deployment and
SERVICE
NEEDS
ongoing maintenance. We offer services
P
DE
EL
OP
and service levels to meet customer
LO
Y
requirements in research, design, validation,
V
DE
and manufacturing.
Visit ni.com/services.
Local Sales and Technical Support
In offices worldwide, our staff is local to the country, giving you access to
engineers who speak your language. NI delivers industry-leading technical
support through online knowledge bases, our applications engineers,
and access to 14,000 measurement and automation professionals within NI
Developer Exchange forums. Find immediate answers to your questions at
ni.com/support.
We also offer service programs that provide automatic upgrades to your
application development environment and higher levels of technical support.
Training and Certification
Visit ni.com/ssp.
NI training is the fastest, most certain route to productivity with our products.
Hardware Services
NI training can shorten your learning curve, save development time, and reduce
maintenance costs over the application life cycle. We schedule instructor-led
System Assurance Programs
courses in cities worldwide, or we can hold a course at your facility. We also
NI system assurance programs are designed to make it even easier for you
offer a professional certification program that identifies individuals who have
to own an NI system. These programs include configuration and deployment
high levels of skill and knowledge on using NI products.
services for your NI PXI, CompactRIO, or Compact FieldPoint system. The NI Basic
Visit ni.com/training.
System Assurance Program provides a simple integration test and ensures that
Professional Services
Our NI Professional Services team is composed of NI applications and systems
engineers and a worldwide National Instruments Alliance Partner program of
more than 600 independent consultants and integrators. Services range from
start-up assistance to turnkey system
integration. Visit ni.com/alliance.
your system is delivered completely assembled in one box. When you configure
your system with the NI Standard System Assurance Program, you can select
from available NI system driver sets and application development environments
to create customized, reorderable software configurations. Your system arrives
fully assembled and tested in one box with your software preinstalled. When
you order your system with the standard program, you also receive systemspecific documentation including a bill of materials, an integration test report,
a recommended maintenance plan, and frequently asked question documents.
Finally, the standard program reduces the total cost of owning an NI system
OEM Support
We offer design-in consulting and product integration assistance if you want to
use our products for OEM applications. For information about special pricing and
services for OEM customers, visit ni.com/oem.
by providing three years of warranty coverage and calibration service. Use the
online product advisors at ni.com/advisor to find a system assurance program
to meet your needs.
Calibration Services
NI recognizes the need to maintain properly calibrated devices for highaccuracy measurements. We provide manual calibration procedures, services
to recalibrate your products, and automated calibration software specifically
designed for use by metrology laboratories. Visit ni.com/calibration.
Repair and Extended Warranty
NI provides complete repair services for our products. Express repair and
advance replacement services are also available. We offer extended warranties
to help you meet project life-cycle requirements. Visit ni.com/services.
ni.com
n
800 813 3693
National Instruments
n
[email protected]
©2009 National Instruments. All rights reserved. CompactRIO, FieldPoint, LabVIEW, MXI, National Instruments, National Instruments Alliance Partner, NI, ni.com, and NI CompactDAQ are
trademarks of National Instruments. Other product and company names listed are trademarks or trade names of their respective companies. A National Instruments Alliance Partner is a
business entity independent from National Instruments and has no agency, partnership, or joint-venture relationship with National Instruments. 2009-10604-161-101-D
Similar pages