MPD ML105S09E Ml100se sery Datasheet

ML100SE Series
Low Cost, Single Output
Ultra-Miniature SMT
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
• 1W Output Power
• Ultra-Miniature SMT Case
• 1,500 VDC Isolation
• Short Circuit Protected
• Single Output
• -40°C to +105°C Operation
• >3.5 MHour MTBF
• 17 Standard Models
• LOW COST!
Input
Parameter
Conditions
Min.
5 VDC Input
4.5
12 VDC Input 10.8
15 VDC Input 13.5
24 VDC Input 21.6
Capacitor
Input Voltage Range
Input Filter
Typ.
5.0
12.0
15.0
24.0
Max.
5.5
13.2
16.5
26.4
Units
Typ.
±3.0
Max.
Units
%
µF
%
VDC
Output
Parameter
Output Voltage Accuracy
Capacitive Load
Line Regulation
Load Regulation, See Note 1
Ripple & Noise (20 MHz), See Note 2
Temperature Coefficient
Output Short Circuit
Conditions
Min.
For Vin Change of 1%
See Model Selection Guide
Output Voltage <12 VDC
30
15 VDC, 24 VDC Output
60
220
±1.2
mV P - P
±0.03
%/ºC
Typ.
Max.
20
100
300
Units
VDC
M⍀
pF
kHz
Continuous (Autorecovery)
General
Parameter
Isolation Voltage
Isolation Resistance
Isolation Capacitance, See Note 3
Switching Frequency
EMI Characteristics
Parameter
EMI Compliance, See Note 5
EMC Compliance
Conditions
60 Seconds
500 VDC
100 kHz, 1V
Conditions
Min.
1,500
1,000
Min.
Conducted
Electrostatic Discharge (ESD)
Typ.
Max.
Units
CISPR22/EN 55022 Level B
EN 61000-4-2 Level B Contact ±8 kV
Environmental
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Case Size
Case Material
Weight
Conditions
Min.
Typ.
-40
+25
-55
Free Air Convection
RH, Non-condensing
Ambient
Max.
+105
+125
Units
ºC
ºC
95
%
0.50 x 0.327 x 0.285 Inches (12.70 x 8.30 x 7.25 mm)
Non-Conductive Black Plastic (UL94-V0)
0.05 Oz (1.52g)
Reliability Specifications
Parameter
MTBF
Conditions
MIL HDBK 217F, 25ºC, Gnd Benign
Min.
3.5
Typ.
Max.
Units
MHours
Min.
-0.7
-0.7
-0.7
-0.7
Typ.
Max.
9.0
18.0
21.0
30.0
300.0
Units
Absolute Maximum Ratings
Parameter
Conditions
Input Voltage Surge (1 Sec)
Lead Temperature
5 VDC Input
12 VDC Input
15 VDC Input
24 VDC Input
1.5 mm From Case For 10 Sec
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
VDC
ºC
www.micropowerdirect.com
Model Selection Guide
Model
Number
ML105S-05E
ML105S-09E
ML105S-12E
ML105S-15E
ML105S-24E
ML112S-05E
ML112S-09E
ML112S-12E
ML112S-15E
ML112S-24E
ML115S-05E
ML115S-15E
ML124S-05E
ML124S-09E
ML124S-12E
ML124S-15E
ML124S-24E
Input
Voltage (VDC)
Nominal
Range
5
4.5 - 5.5
5
4.5 - 5.5
5
4.5 - 5.5
5
4.5 - 5.5
5
4.5 - 5.5
12
10.8 - 13.2
12
10.8 - 13.2
12
10.8 - 13.2
12
10.8 - 13.2
12
10.8 - 13.2
15
13.5 - 16.5
15
13.5 - 16.5
24
21.6 - 26.4
24
21.6 - 26.4
24
21.6 - 26.4
24
21.6 - 26.4
24
21.6 - 26.4
Output
Current (mA)
Voltage Current
Current
Full-Load No-Load (VDC) (mA, Max) (mA, Min)
250
20
5.0
200.0
20.0
250
20
9.0
111.0
12.0
250
20
12.0
84.0
8.0
250
20
15.0
67.0
7.0
250
20
24.0
42.0
4.0
104
15
5.0
200.0
20.0
104
15
9.0
111.0
12.0
103
15
12.0
84.0
8.0
103
15
15.0
67.0
7.0
103
15
24.0
42.0
4.0
83
10
5.0
200.0
20.0
82
10
15.0
67.0
7.0
52
7
5.0
200.0
20.0
52
7
9.0
111.0
12.0
51
7
12.0
84.0
8.0
51
7
15.0
67.0
7.0
51
7
24.0
42.0
4.0
Notes:
1. Output load regulation is specified for a load change of 10% to 100%.
2. When measuring output ripple, it is recommended that an external 0.33 µF ceramic capacitor be placed from
the +Vout pin to the -Vout pin.
3. The isolation capacitance of model ML124S-24E is 30 pF.
4. Operation at no load will not damage these units, however, they may not meet all specifications.
5. These converters are specified for operation without external components. However, in some applications the
addition of input/output capacitors will enhance stability and reduce output ripple. The simple connection shown
below will typically meet EN 55022 Class B.
VIN
C1
L1
C2
VOUT
C3
5 VDC
12 VDC
15 VDC
24 VDC
4.7 µF/50V
4.7 µF/50V
4.7 µF/50V
4.7 µF/50V
6.8 µH
6.8 µH
6.8 µH
6.8 µH
----470 pF/2kV
470 pF/2kV
5 VDC
9 VDC
12 VDC
15 VDC
24 VDC
10 µF
4.7 µF
2.2 µF
1.0 µF
0.47 µF
6. It is recommended that a fuse be used on the input of a power supply for
protection. See the Model Selection table above for the correct rating.
Rating
Efficiency Fuse
Slow-Blow
(%, Typ)
(mA)
Load Regulation
% Typ.
12.0
8.0
7.0
6.0
5.0
12.0
8.0
7.0
6.0
5.0
12.0
6.0
12.0
8.0
7.0
6.0
5.0
% Max
15.0
10.0
10.0
10.0
10.0
15.0
10.0
10.0
10.0
10.0
15.0
10.0
15.0
10.0
10.0
10.0
10.0
80
80
80
80
80
80
80
81
81
81
80
81
80
80
81
81
81
500
500
500
500
500
200
200
200
200
200
200
200
100
100
100
100
100
Derating Curve
Pin Connections
Pin
1
2
Mechanical Dimensions
Description
-VIN
+VIN
Pin
4
5
8
Description
-VOUT
+VOUT
NC
NC = No Connection
Board Layout
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
• Pin 1 is marked by a “dot” or indentation on the unit
FAX: (781) 344-8481
•
E-Mail: [email protected]
Similar pages