ILPA30JW SERIES
30W Water-Proof Constant Current LED Driver
–
–
–
–
–
–
–
2 Year Warranty
Wide Input Voltage 90 to 264VAC, 47 to 63Hz
Constant Output Current Available From 0.35A To 2.5A
Over Voltage, Short Circuit, Lighting, and Over Temperature Protection
High Efficiency (up to 86%)
Active Power Factor Correction (PFC) (86% typical)
IP67 Waterproof Rating, Metal Housing
Comply with UL8750 & EN61347 Safety Regulation
Approvals:
Single Output
Output Current Range
Output Voltage Range
Part Number
(Min. / Typ. / Max.)
(Min. / Max.)
ILPA30JW-S250SS
2375 / 2500 / 2625 mA
7 / 12 VDC
ILPA30JW-S166SS
1580 / 1660 / 1740 mA
9 / 18 VDC
ILPA30JW-S125SS
1190 / 1250 / 1310 mA
13 / 24 VDC
ILPA30JW-S083SS
790 / 830 / 870 mA
18 / 36 VDC
ILPA30JW-S070SS
665 / 700 / 735 mA
21 / 42 VDC
ILPA30JW-S045SS
428 / 450 / 472 mA
33 / 66 VDC
ILPA30JW-S035SS
333 / 350 / 367 mA
43 / 86 VDC
Item -S250SS, -S166SS, -S125SS use Class 2 output (USR & CNR).
Item -S083SS, -S070SS -S045SS, -S035SS use Non-Class 2 output (USR & CNR).
Efficiency
(220VAC, Full Load)
83%
84%
85%
86%
86%
86%
87%
Over Voltage Protection
(Min/Typ/Max)
14 / 16 / 18 VDC
22 / 24 / 27 VDC
29 / 32 / 36 VDC
43 / 48 / 54 VDC
50 / 57 / 63 VDC
79 / 89 / 99 VDC
103 / 116 / 129 VDC
Max.
Output Power
30W
30W
30W
30W
30W
30W
30W
Electrical Characteristics
Parameter
Input Voltage
Input Frequency
Output Power Range
Input Current (Low Line)
Input Current (High Line)
High Line Inrush Current
Power Factor Correction
Efficiency
No-Load Power Consumption
Line Regulation
Load Regulation
Over Voltage Protection
Over Temperature Protection
Short Circuit Protection
Output Overshoot / Undershoot
Start Up Time
Ripple & Noise (Peak to Peak)
Test Conditions
Operating Voltage
Min.
90
47
0
Typ.
Max.
264
63
30
0.43
0.25
65
Unit
VAC
Hz
W
A
A
A
%
%
W
%
%
Vin=90 to 264VAC
Io=Full load, Vin=115VAC
Io=Full load, Vin=230VAC
Io=Full load, 25°C, Cool start, Vin=230VAC
Vin=110VAC
86
Io=Full Load, Vin=230VAC
82.5
87
No Load, VIn=230VAC
1
Io=Full Load
1
Vin=230VAC
3
Latch mode. The power unit shall return to normal operation only after the power is turn-on again.
(Please refer to output table.)
110
°C
No damage shall occur when any output operating in a short circuit condition. The power supply shall be
self-recovery when the fault condition is removed.
When power on or off
10
%
Io=Full Load, Vin=100VAC
3
S
Measured by 20 MHz bandwidth oscilloscope and the
output paralleled a 0.1 uF ceramic capacitor and a 10
2
% Vo
uF electrolytic capacitor.
Conditions
Parameter
Test Conditions
Operating Temperature
Humidity: 10% RH to 100% RH
Storage Temperature
Humidity: 5% RH to 100% RH
Operation temperature at 25°C, calculated per MIL-HDBK-217F
Life Time at 25°C ambient temperature
No output power derating from -35°C to 60°C
Min.
-35
-40
0.3M
0.08M
Typ.
Max.
60
85
Unit
°C
°C
Hours
Hours
Approvals and Compliance
Parameter
EMI
EMS
Safety UL/c-UL, CE
Waterproof
Standards
EN55015
EN61000-3-2, EN61000-3-3, EN61000-4-2, EN61000-4.3, , EN61000-4-4, , EN61000-4-5, EN61000-4-6,
EN61000-4-8, EN61000-4-1-1, EN61547
UL8750 Compliant to UL1310 Class 2, UL1012, UL935, CSA-C22.2 No. 0, CSA-C22.2 No. 107.1, CSA-C22.2
No.250.0, EN61347-1,EN61347-2-13
IP67 Rating
Mechanical
Parameter
Dimension,
Net Weight
Specification
162x34.5x42.5mm (6.38x1.36x1.67 inches)
460g