SPSEMI GDT/SPX Series Gas Discharge Tube SPX Series Features Electronic stability Small volume, easy to placement machine operation Large flow capacity, impact resistant ability Static electricity capacity, good insulation Reaction speed is 50 ns - 150 ns Applications ADSL MODEM、FAX、TELEPHONE RS485、RS232、CAN level of protection CATV Power supply prevents thunder common-mode protection Marking Code No Mark Product Name SPX150FX Internal Code(Default) F:Two Parties A:A Round Nom. DC spark-over voltage Vs 150:150V 200:200V 350:350V SPX : 2R/0.5KA SPA : 2R/2.5KA SPB : 2R/5KA SPC : 2R/5KA SPH : 2R/20KA 3SPC : 3R/5KA 3SPH : 3R/20KA REV . 2016 . 12 . 12 www.spsemi.cn Page 1 of 3 SPSEMI GDT/SPX Series Dimensions 1.6±0 . 2 3.2±0 . 2 0.3 1.6±0 . 2 3.2±0 . 2 1.6±0 . 2 0.3 Dimensions in millimeters Electrical Characteristics Impulse Nom. DC Impulse Nom.Impulse Insulation Discharge Alternating Spark-over Spark-over Discharge Resistance Capacitance Current Discharge Voltage Voltage Current Part Number (pF) Current One Operation (@8/20μs) (@100V/s) (@1KV/μs) (@8/20μs) (@50HZ) (@DC) (V) (KA) (V) (GΩ) (KA) (A) (V) SPX150F 150±30 % ≦750 0.5 2 1 >1 50 < 0.8 SPX200F 200±30 % ≦800 0.5 2 1 >1 100 < 0.8 SPX350F 350±30 % ≦850 0.5 2 1 >1 100 < 0.8 SPX450F 450±30 % ≦900 0.5 2 1 >1 250 < 0.8 SPX600F 600±30 % ≦950 0.5 2 1 >1 250 < 0.8 Packaging Speci Cations Packaging:4500 pieces per reel Initial Characteristics Test Item Test Method Specification DC-Spark-Over Voltage Vs Add and measure the DC Voltage gradually Maxto get the discharge threshold voltage. The measuring current is 1mA/1 second max.(1sec ) .(1mA) It depands on each spec. Insulation Resistance Measure the insulation resistance of two end of leadwire under the specified DC voltage. 100MΩ min. Capacitance C(pF) Electrostatic Capacitance under the test condition of 1KHz,DC 6V(max). 0.8pF max. REV . 2016 . 12 . 12 www.spsemi.cn Page 2 of 3 SPSEMI GDT/SPX Series Surge Characteristics Test Item Test Method Specification Surge withstand capability In the glass tube ends in 8/20 us surge tester, applying the model that corresponds to the impact resistance current, time interval for the 60 s of plus or minus the test 5 times. Test the dc voltage, insulation resistance, static capacitance and check the appearance. DC spark-over voltage JSE: △ Vs/Vs ≦ 30% Surge life test Apply 10KV voltage charged in 1500pF condenser and apply the current to the specimen,200 times at 10 seconds of intervals. Within standard mentioned in Initial Characteristics. Enviromental Characteristics Test Item Test Method Specification Cold resistance After -40±3℃ (1000hrs) / room temp.,normal humidity(4 hrs) cycle, measure the properties. Within standard mentioned in Initial Characteristics. Heat resistance After 125±2℃ (1000hrs) / room temp.,normal humidity(4 hrs) cycle, measure the properties. Within standard mentioned in Initial Characteristics. Temperature resistance After 85±2℃ RH85%(1000hrs) / room temp.,normal humidity(4 hrs) cycle, measure the properties. Within standard mentioned in Initial Characteristics. Temperature period 25 times repetition of cycle -40±3℃ (30 Min.),roon temp., (4 Min.), 125±2 ℃ (30Min.), room temp., normal humidity(4hrs) . Within standard mentioned in Initial Characteristics. Tensile strength Apply 2.5kgs load approximately 30 seconds, then check for pull-out and breaking of the lead wire. Within standard mentioned in Initial Characteristics. Bending strength Bend the lead wire, with jig which radius is 0.75~0.8mm, at the point of 2mm from the body, under 0.25 kgs load applied at the right angle the direction of theamis and get the bent lead wire back to its original poing after the procedure was repeated 2times. Within standard mentioned in Initial Characteristics. Resistance to soldering attachment ( by solder dip ) Apply flux and immerse in molten solder, up to the point of 3mm from the body,for 5 sec. (235 ℃ ±5 ℃ ). Wash the leadwire and check for soldering adhesion. Lead wire is evenly covered by solder over 90%. Resistance to soldering heat ( by solder dip ) Apply flux and immerse in molten solder, up to the point of 3mm from the body,for 5 sec. (235 ℃ ±5 ℃ ). Wash the leadwire and check forsoldering adhesion.) Within standard mentioned in Initial Characteristics. REV . 2016 . 12 . 12 www.spsemi.cn Page 3 of 3