mk150s C o m p a c t 1 5 0 Watt Enclosed Switching Power Supplies series Universal 88-264VAC Auto Range Input Compact Footprint High Efficiency Regulated Outputs 3000V Isolation Built in EMI Filter 3.5”W x 6”L x 1.75”H Model Number Output Voltage Output Amps (max) Ripple/Noise pp,typ MK150S-5 MK150S-12 MK150S-15 MK150S-24 5 VDC 12 VDC 15 VDC 24 VDC 30 12.5 10 6 100mv 100mv 100mv 100mv Order On-Line! WWW.ASTRODYNE.COM astrodyne.com 300 Myles Standish Blvd., Taunton, MA 02780 Ph: 1-800-823-8082 Fax: 508-823-8181 C o m p a c t 1 5 0 Watt Enclosed Switching Power Supplies INPUT SPECIFICATIONS Input Voltage Range Frequency Range Inrush Current, typ: series ENVIRONMENTAL SPECIFICATIONS 88-132/176-264 VAC Auto Voltage Select 47-63 Hz 20A @ 100VAC * 40A @ 200VAC * Oper. Temperature Storage Temperature Relative Humidity EMI (Designed to Meet) MTBF See Selection Chart ± 0.5%, typ ± 1%, typ ± 6%, typ ± 0.03%/°C 100mV, typ 130%, Latching, Re-power * 160%, Indefinite 20mS, typ (Nom I/P, FL) ≤ 1.0 sec, typ ≤ 20 msec, typ < 10% of FS PHYSICAL SPECIFICATIONS OUTPUT SPECIFICATIONS Voltage and Current Line/Load Regulation (10%-FL) Voltage Tolerance DC Voltage Adjust (typ) Temperature Coefficient Ripple/Noise Over Voltage Protection Short Circuit Protection Hold Up Time Turn On Time Rise Time Over/Under Shoot mk150s Size Construction Weight 0 to +60°C (See Derate Curve) -25 to +85°C * 10% to 90%, non-cond * EN55011, Class B 100,000 Hrs Mil Std 217, 25°C 6” x 3.5” x 1.75” Enclosed 1.37 lb, (630g) GENERAL SPECIFICATIONS Isolation Efficiency Switching Frequency Safety I/P-O/P: 3000VAC I/P-Ground: 1500VAC O/P-Ground: 500 VAC 78%, typ 100Khz, (fixed, typical) EN60950, IEC60950 UL60950 All specifications are typical at nominal input, full load, and 25°C unless otherwise noted * These are stress ratings. Exposure of the devices to any of these conditions may adversely affect long term reliability. Proper operation under conditions other than the standard operating conditions is neither warranteed nor implied. WWW.ASTRODYNE.COM Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications. 300 Myles Standish Blvd., Taunton, MA 02780 Ph: 1-800-823-8082 Fax: 508-823-8181 mk150s C o m p a c t 1 5 0 Watt Enclosed Switching Power Supplies series MECHANICAL DIMENSIONS Pin # Outputs 1 2 3 4 5 6 7 ACN ACL GND + Output + Output - Output - Output PLEASE NOTE: To improve specifications and safety isolation, connection designations may have changed from prior revisions. Please verify connections per product labels on input and output connections prior to applying power to the unit OUTPUT DERATING CURVE (Forced air cooling direction: Straight down from top of unit) 22CFM Forced Air - All Outputs (Recommended) 1 2 3 12/15/24VDC Outputs, Convection Cooled 5VDC Output, Convection Cooled 120 1 100 Load, % 80 60 2 40 3 20 0 0 5 10 15 20 25 30 35 40 45 50 55 60 Ambient Temp, C WWW.ASTRODYNE.COM 300 Myles Standish Blvd., Taunton, MA 02780 Ph: 1-800-823-8082 Fax: 508-823-8181