MB65S 65W Single Output Medical Series Features 2” x 3.5’ x 1.3” Package, Ideal for 1U Applications 10-year life design with Premium E-Caps 65 Watts convection cooled Class I and Class II models Class B Conducted and Radiated EMI Performance BF Isolation Type Rated th Designed to meet new IEC 60601-1-2 4 Edition EMC Requirements Approved to AAMI ES/CSA C22.2/EN/IEC60601-1, rd 3 Edition 2 x MOPP Isolation Internal Temperature Monitor, DC – OK Signal, LED 3 Year Warranty Description A superior performance 65 Watt AC to DC power supply designed for next generation medical applications. Feature rich and highly efficient, MB65 product family can easily fit in a 1U chassis and provides 65 Watts of convection power. Input & output and internal temperature monitoring/alarms are features of the MB65 family. All models are CE marked to low rd voltage directive and approved to AAMI ES/CSA C22.2 No./EN/IEC60601-1, 3 edition. The design takes into th consideration the pending international release of the new IEC 60601-1-2, 4 Edition EMC requirements. With low leakage current performance, the power supplies are BF rated. Model Selection Model Number Class Volts Output Current (Convection Cooled) Efficiency Total Regulation OVP Threshold MB65S12K Class I 12V 5.4A 88% 0.5% ±1% 17.3 ± 2.4V MB65S12C Class II 12V 5.4A MB65S15K Class I 15V 4.3A 88% 0.5% ±1% 17.3 ± 2.4V 88% 0.5% ±1% MB65S15C Class II 15V 20.1 ± 2.4V 4.3A 88% 0.5% ±1% 20.1 ± 2.4V 1 Ripple &Noise 2 MB65S24K Class I 24V 2.7A 89% 0.5% ±1% 29.3 ± 3.5V MB65S24C Class II 24V 2.7A 89% 0.5% ±1% 29.3 ± 3.5V MB65S48K Class I 48V 1.35A 90% 0.5% ±1% 55.5 ± 4.5V MB65S48C Class II 48V 1.35A 90% 0.5% ±1% 55.5 ± 4.5V Notes: 1) Efficiency, Typical at 115/230Vac, 25°C. See Charts below for load conditions. 2) Measured at 25C using 6 inch twisted pair wires with noise probe directly across output terminals, and load terminated with 0.1µF ceramic and 10µF low ESR capacitors. 3) Part number suffix to include “K” for Class-1 AC input, or “C” suffix for Class-2 AC Input Consult Factory for following Models, availability may vary. MB65S18K Class I 18V 3.6A 89% 0.5% ± 1% 21.7 ± 2.5V MB65S18C Class II 18V 3.6A 89% 0.5% ± 1% 21.7 ± 2.5V MB65S28K Class I 28V 2.3A 89% 0.5% ± 1% 35.2 ± 3.5V MB65S28C Class II 28V 2.3A 89% 0.5% ± 1% 35.2 ± 3.5V MB65S32K Class I 32V 2.0A 89% 0.5% ± 1% 41.5 ± 4.5V MB65S32C Class II 32V 2.0A 89% 0.5% ± 1% 41.5 ± 4.5V www.slpower.com MB65S Aug -14 1 MB65S 65W Single Output Medical Series General Specifications AC Input Input Current 85-264Vac, single phase. (Safety Approved to 90-264Vac). Turn On Time Rise Time 1.5A at 110Vac, 1A at 240Vac <2 Seconds at 110Vac. <30mS, 48V model: < 40mS Inrush Current 40Arms Maximum within a half line cycle, cold start at 25C. See application note. I²T Characteristic See Table below. Over Load Protection (OCP) 115% - 200% of rated output current value. Hiccup Mode, Auto-recovery Turn-On Input Voltage >75Vac ± 8Vac. Full spec performance at 85Vac. Short Circuit Protection (SCP) Short across the output terminals will not cause damage to the unit. Hiccup Mode , Auto-recovery Turn-Off Input Voltage <63Vac ± 8Vac Over Voltage Protection (OVP) Latches off when output voltage is with range as shown in table. Requires AC Power cycle to reset Input Fuses Earth Leakage Current Patient Leakage Current (Output to Earth) Touch Current No Load Input Power Hold-up Time 3.15A, 250Vac, line and neutral inputs Over Temperature Protection (OTP) <350 µA@264Vac, 60Hz input, NC Output Reverse Voltage Protection <4 mA@264Vac, 60Hz input, NC for BF rating Isolation <90 µA@264Vac, 60 Hz input, NC, also suitable for BF rating <450 µA@264Vac, 60Hz input, SFC, also suitable for BF rating Turn-On & Operating Temperature <0.5W Storage Temperature Efficiency 88% - 90% typical at 115/230Vac, 25°C. See chart for additional details Altitude Output Power 65W continuous convection cooled, -20C to 50°C ambient. 85Vac to 264Vac. See chart for derating above 50°C. Relative Humidity Transient Response Ripple and Noise Output Voltage Voltage Adjustability www.slpower.com 500µS typ. response time for return to within 0.5% of final value for a 50% load change, ∆i/∆t< 0.2A/µs. Max. volt. deviation is ±3.5%. Shock (IEC 60068-2-27) 0.5% pk-pk Vibration (IEC 60068-2-6) (IEC 60068-2-64) 12V to 48Vdc. See models chart for part numbering. MTBF E-Cap Life +/- 10%, 48V is +/- 5% MB65S Aug -14 20mS min. from loss of AC input at 110 Vac, full load, 25°C. ℃ Power shuts down at temperature of 70 (typical) at full load. Hiccup Mode , Auto-recovery Outputs protected against momentary reverse current less than 20A peak for less than 10mS with 0.5A average. Sustained reverse current at high levels may damage unit. Input-Output: 4500Vac, 2 x MOPP Input-Ground: 1900Vac, 1 x MOPP Output-Ground: 1900Vac, 1 x MOPP -20°C to +70°C. Turn on Temperature = -40°C at >=120Vac, allowing [x] seconds for stabilization. De-rated output power at 70°C = 45.5W -40°C to +85°C Operating: -500m to 3000m Non-operating: -500 to 40,000 feet 5% to 95%, non-condensing Operating: Half-sine shock waveform. Impact Acceleration: 20g, Pulse duration: 11mS. Cycles: 3 times per axis in X,Y, Z direction Non-Operating: Half-sine shock waveform. Impact Acceleration: 100g, Pulse duration: 6mS Cycles: 3 times per direction on 3 axes (X,Y. Z) Operating: Sinusoidal Frequency: 10-500Hz, Impact Acceleration: 1g, Sweep rate: 1 octave/min Cycles: 10 times per axis in X, Y, Z direction Random Vibration: Operating: 0.003g2/Hz, 1.224grms overall, 3 axes, 10 min per axis, 1-500Hz. Non-Operating: 0.02g2/Hz, 3.1grms overall, 3 axes, 1 hour per axis, 20-500 Hz 564,500 hours (ave) @ 110Vac, 25°C, SR332 Issue 6. Consult Factory @ 220Vac, 25°C, SR332 Issue 6. >10 Years in use condition of 40°C ambient, at 12h/day, 261 days/year. Additional information on other use profiles available on request. 2 MB65S 65W Single Output Medical Series General Specifications (Continued) Overshoot HF Common Mode Noise Total Regulation Minimum Load <2% overshoot at turn-on, <1% overshoot at turnoff, under all conditions. IPC 610 Safety Standards 0.8 Vrms maximum (input class I) Weight ±1.0 % for all models. Dimensions Not required. Class 2 IEC 60601-1, 3rd Edition ANSI/AAMI ES60601-1 (2008) CAN/CSA – C22.2 No 60601-1 (2005) DEMKO EN60601-1:2006 Designed to meet China Safety Doc. No. GB4943.12011 at 5Km, Tropical Standard at 40°C, 93% RH at 120 hours. 140g, typical W: 2.0” x L: 3.5” x H: 1.3” W: 50.8mm x L: 88.9mm x H: 33.02mm Additional Outputs DC OK: During normal operation, this signal is logic HIGH. Signal will go LOW for output less than % (typical) of nominal. Green LED will light on PCB top side during normal operation. 80 PSU Temperature Provides resistive value indicating internal temperature of power supply. See Temp Sensor Conversion Table below. EMI/EMC Compliance EN55011/22: Class B, FCC Part 15. Class B: 6db margin typ, Class 1 PSU configuration EN55011/ 22: Class B, FCC Part 15. Class B: 2db margin typ, Class 2 PSU configuration EN55011/22: Class B, FCC Part 15. Class B: 3db margin typ, Class 1 PSU configuration. EN55011/22: Class B, FCC Part 15. Class B: 3db margin typ, Class 2 PSU configuration. Conducted Emissions Radiated Emissions Harmonic Current Emissions IEC61000-3-2: Class A Voltage Fluctuations & Flicker IEC 61000-3-3 IEC61000-4-2: Level 4, 8kV Contact Discharge, 15kV air discharge, Criteria A. Also meets proposed IEC60601-1-2, 4th edition, Table 4 IEC61000-4-3: Level 3, 10V/m, Criteria A. 80MHz-1000 MHz and 3V/m 1.4Ghz to 2.7 GHz. 80% AM at 1kHz. Also meets proposed IEC60601-1-2, 4th edition, Table 4 Electro Static Discharge Immunity Radiated RF EM Fields Susceptibility Proximity Fields from RF wireless communications Equipment [IEC60601-1-2: 4th edition, Table 4] Rated Power Frequency magnetic fields IEC61000-4-8: Level 5, 30A/m, 50/60 Hz Low Frequency magnetic fields [TBD] Electrical Fast Transients /Bursts Surges Line to Line (DM) and Line to Ground (CM) Conducted Disturbances induced by RF Fields Rated Power Frequency Magnetic Fields Test IEC61000-4-4: Level 3, 2KV, 100Khz rep rate, 40A (PS Output), Criteria A IEC61000-4-4: Level 3, 1kV, 20A, (Other Outputs), Criteria B Also meets proposed IEC60601-1-2, 4th edition standard, Table 5 & 6. IEC61000-4-5: Level 3, +/-1kV DM, +/-2kV CM, Criteria A Also meets proposed IEC60601-1-2, 4th edition standard, Table 5. IEC61000-4-6: 3V/m & 10 V/m – 0.15 to 80Mhz and 10V/m in ISM and amateur radio bands between 0.15 MHz and 80 MHz, 80% AM at 1 KHz Also meets proposed IEC60601-1-2, 4th edition standard, Table 5 & 6 & 8. IEC61000-4-8: Level 4 (30A/m), Criteria A Also meets proposed IEC60601-1-2, 4th edition standard, Table 4 enclosure port. Voltage Dips IEC61000-4-11: 100% dip for 10mS, at 0°, 45°, 90°, 135°, 180°, 225°, 270° and 315°, Criteria A; 60% dip for 100mS, Criteria B; 30% dip for 500mS (25/30 cycles) 1∅, and 0° for 500mS, Criteria A. Also meets proposed IEC60601-1-2, 4th edition standard, Table 5. Enclosure Port Immunity to RF wireless communications equipment IEC61000-4-3 Notes: Performance criteria are based on definitions contained in EN55024. Performance criteria are: A – Normal performance during and after the test, B – Temporary degradation, self-recoverable, C – Temporary degradation, operator intervention required to recover the operation, D – Permanent damage may occur www.slpower.com MB65S Aug -14 3 MB65S 65W Single Output Medical Series Isolation Specifications Parameter Conditions/Description Insulation Safety Rating Input/Ground Input/Output Output/Ground Electric Strength Test Voltage Input/Ground Input/Output Output/Ground Min Nom Max Units - Vac Vac Vac 1 MOPP 2 MOPP 1 MOPP 1900 4500 1900 - Mechanical Drawing Connector Information Input Connector J1 PIN 1) AC Line PIN 2) Empty (removed) PIN 3) AC Neutral DC Output Connector J2 Mating Connector: Pin 1) (+V1) Pin 2) (+V1) Pin 3) (RTN) Pin 4) (RTN) Mating Connector: Tyco/AMP 640250-3 Pins: 640252-2 Tyco/AMP 640250-4 Pins: 640252-2 www.slpower.com Ground Connector G1 FG 0.187” Quickconnect tab Mating Connector: Molex 01-90020005 Signal Connector J3 PIN 1) RTN PIN 2) DC_OK Pin 3) TEMP SEMSOR (+) Pin 4) TEMP SEMSOR (-) Mating Connector: Tyco/AMP 1375820-4 Pins: 1375819 MB65S Aug -14 4 MB65S 65W Single Output Medical Series 1.DC-OK signal (J-3): During normal operation, this signal is logic HIGH for output more than 85% (typical) of normal. Signal will go LOW for output less than 80% (typical) of normal. Green LED will light on PCB top side during normal operation. 2. Temperature sensor signal (J-3): Internal Temperature Sensor Conversion Table Resistance Value across connector J3, pins 3-4 Internal Temperature 6,040K ohms -20℃ 3,227K ohms -10℃ 1,788K ohms 0℃ 1,025K ohms 10℃ 605.1K ohms 20℃ 367.6K ohms 30℃ 229.2K ohms 40℃ 146.4K ohms 50℃ 95.62K ohms 60℃ 63.80K ohms 70℃ 43.40K ohms 80℃ 30.07K ohms 90℃ 21.19K ohms 100℃ Notes: 1) Tolerances: -20°C to 60°C: +/- 4°C; 70°C to 80°C: +/- 5°C; 90°C to 100°C: +/- 6°C. www.slpower.com MB65S Aug -14 5 MB65S 65W Single Output Medical Series 3. Timing Sequence 4. Protection All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted. Parameter Conditions/Description Input Fuses Not user accessible Input Transient Protection Min Nom Max Units KV (CM) 2KV(CM) and 1KV(DM) surge 2 No-load and short circuit proof Hiccup short circuit proof Hiccup overload Hiccup Overvoltage Protection Latch style Latch Over temperature Protection Automatic power shutdown at TA = 80°C(typical) Output 5. Inrush Current, peak (I2T rating) Measured at 264Vac, 50°C at 100% loading, 70°C at de-rated load condition 50°°C - 2 I T rating 70°°C 2 - I T rating Model (A2Seconds, Typical) (A2Seconds, Typical) 12V Model 8.5 11.0 15V Model 6.5 13.2 24V Model 10.9 12.2 48V Model 10.4 11.1 www.slpower.com MB65S Aug -14 6 MB65S 65W Single Output Medical Series 6. Characteristic Curves 6.1 Output vs. Temperature Output Power (Watts) Output Power - Convection vs. Ambient Temperature 70 60 50 40 -20 -10 0 10 20 30 40 50 60 70 Ambient Operating Temperature (°C) 65W convection cooled at -20°C to 50°C operating ambient temperature. De-rated output power to 45.5W at 70°C. 6.2 Efficiency vs. Loading at AC Input Voltages 100% 90% 80% Efficiency 70% 60% 50% 115V 40% 230V 30% 20% 10% 0% 0.0 6.5 13.0 19.5 26.0 32.5 39.1 45.3 51.9 58.4 65.0 Output power(W) High efficiency is achieved by using QR technology. Synchronous MOSFETs or ultra-fast diodes are used as rectifiers in MB65S family. www.slpower.com MB65S Aug -14 7 MB65S 65W Single Output Medical Series 6.3 Efficiency vs. Loading The charts below detail the MB65 efficiency vs input voltage and output loading conditions at 25°C, 50°C and 70°C under de-rated power. 25°C ambient 50°C Ambient 91.0% 92.0% 91.0% Efficiency 90.0% 230V 12V 89.0% 115V 15V 88.0% 230V 15V 87.0% 115V 24V 86.0% 230V 24V Efficiency 115V 12V 115V 12V 90.0% 89.0% 230V 12V 88.0% 87.0% 230V 15V 115V 15V 115V 24V 86.0% 230V 24V 115V 48V 115V 48V Load(% of rated) 230V 48V 70°C Load(% of rated) 230V 48V Ambient Efficiency 91.0% 90.0% 115V 12V 89.0% 230V 12V 88.0% 115V 15V 87.0% 230V 15V 86.0% 115V 24V 230V 24V Load(% of rated) 115V 48V 6.4 Ripple & Noise Measured using a scope probe socket with 0.1µF ceramic and a 10µF electrolytic capacitor connected in parallel across it. Bandwidth limit is 20MHz. 12V OUT, NO LOAD, 85VAC, 60HZ www.slpower.com 12V OUT, FULL LOAD, 85VAC, 60HZ MB65S Aug -14 8 MB65S 65W Single Output Medical Series 6.4 Ripple & Noise (Cont’d) 12V OUT, NO LOAD, 264VAC, 50HZ 12V OUT, FULL LOAD, 264VAC, 50HZ 6.5 Output Transient Response 50% load step within the regulation limits of minimum and maximum load, dI/dt< 0.2A/µSec. Recovery time not specified as there are no lapse in regulation with a 50% Load Step. Maximum voltage deviation is 3.5% 5%~50% Load Transient (AC) at 25°C@115V www.slpower.com 50%~100% Load Transient(AC) at 25°C@115V MB65S Aug -14 9 MB65S 65W Single Output Medical Series 6.6 Output Overload Characteristic Supply protects itself against overload conditions. The Power Supply recovers from Overload Conditions without operator intervention. 12v out, 100Vac 12V out, 240Vac 6.7 Turn-On Time 12v out, FULL Load, 115Vac 12V out, Full Load, 230Vac Data Sheet © 2014 SL Power Electronics Corp. The information and specifications contained herein are believed to be correct at the time of publication. However, SL Power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice. www.slpower.com MB65S Aug -14 10