ETC2 ACI4410HHU Product data sheet aci 4410 hhu Datasheet

Product Data Sheet ACi 4410 HHU
Product Data Sheet ACi 4410 HHU
ACi 4410 HHU
INDEX
1
General ...................................................................................................................................................................... 3
2
Mechanics ................................................................................................................................................................. 3
2.1
2.2
3
Operating Data .......................................................................................................................................................... 5
3.1
3.2
3.3
3.4
3.5
3.6
4
General .............................................................................................................................................................. 8
Climatic Requirements*) .................................................................................................................................... 8
Safety ......................................................................................................................................................................... 9
5.1
5.2
6
Operating Data - Electrical Interface - Input ...................................................................................................... 5
Electrical Operating Data ................................................................................................................................... 5
Operating Data - Electrical Interface - Output ................................................................................................... 5
Electrical Features ............................................................................................................................................. 6
Aerodynamics .................................................................................................................................................... 7
Sound Data ........................................................................................................................................................ 8
Environment .............................................................................................................................................................. 8
4.1
4.2
5
General .............................................................................................................................................................. 3
Connections ....................................................................................................................................................... 4
Electrical Safety ................................................................................................................................................. 9
Approval Tests ................................................................................................................................................... 9
Reliability ................................................................................................................................................................... 9
6.1
General .............................................................................................................................................................. 9
8/17/2015
page 2 of 10
Product Data Sheet ACi 4410 HHU
1
General
Fan type
Rotating direction looking at rotor
Airflow direction
Bearing system
Mounting position
2
Mechanics
2.1
General
Width
Height
Depth
Diameter
Mass
Housing material
Impeller material
Max. torque when mounted across both mounting
flanges
Screw size
Fan
Clockwise
Air outlet over struts
Ball bearing
Any
120,0 mm
120,0 mm
38,0 mm
0,0 mm
0,275 kg
Plastic
Plastic
wire outlet corner: 50 Ncm
remaining corners: 80 Ncm
ISO 4762 - M4 degreased, without an additional
brace and without washer
8/17/2015
page 3 of 10
Product Data Sheet ACi 4410 HHU
2.2
Connections
Electrical connection
Lead wire length
Cable
L = 310 mm
+- 20 mm
Tolerance
See drawing
Tube length
Tolerance
Wire size (AWG)
Wire 1
Wire 2
20
Colour
brown
black
Operation
L
N
8/17/2015
page 4 of 10
Product Data Sheet ACi 4410 HHU
3
Operating Data
3.1
Operating Data - Electrical Interface - Input
External voltage supply for input and output signals must be SELV conform.
3.2
Electrical Operating Data
Measurement
conditions:
∆p = 0:
I:
Features
Voltage range
Nominal voltage
Frequency
Power consumption
Tolerance
Speed
Tolerance
3.3
Normal air density = 1,2 kg/m3; Temperature 23°C +/- 3°C; Motor axis horizontal;warm-up
time before measuring 5 minutes (unless otherwise specified).In the intake and outlet area
should not be any solid obstruction within 0,5 m.
corresp. to free air flow (see section 3.5)
corresp. to arithm. mean current value
Condition Symbol
Values
∆p = 0
U
∆p = 0
UN
115 V
∆p = 0
f
50 Hz
4,4 W
∆p = 0
P
+- 20,0 %
∆p = 0
3.300 1/min
+- 10,0 %
n
Operating Data - Electrical Interface - Output
External voltage supply for input and output signals must be SELV conform.
Tacho type
None
Alarm type
None
8/17/2015
page 5 of 10
Product Data Sheet ACi 4410 HHU
3.4
Electrical Features
Electronic function
Locked rotor protection
Speed-Controlled
Auto restart
8/17/2015
page 6 of 10
Product Data Sheet ACi 4410 HHU
3.5
Aerodynamics
Measurement
conditions:
Measured with a double chamber intake rig acc. to DIN EN ISO 5801.
Normal air density = 1,2 kg/m3; Temperature 23°C +/- 3°C;
In the intake and outlet area should not be any solid obstruction within 0,5 m.
The information is only valid under the specified test conditions and may be changed by the
installation conditions. If there are deviations from the standard test conditions, the
characteristic values must be checked under the installed conditions.
a) Operation condition:
3.300 1/min at free air flow
Frequency: 50 Hz
Max. free-air flow (∆p = 0 / = max.)
Max. static pressure (∆p = max. / =0)
Nominal voltage: 115 V
175,0 m3/h
78 Pa
8/17/2015
page 7 of 10
Product Data Sheet ACi 4410 HHU
3.6
Sound Data
Measurement
conditions:
Sound pressure level: 1 Meter distance between microphone and the air intake.
Sound power level: Acc. to DIN 45635 part 38 (ISO 10302)
Measured in a semianchoic chamber with a background noise level of Lp(A) < 5 dB(A)
For further measurement conditions see section 3.4
a) Operation condition:
3.300 1/min at free air flow
Optimal operating point
Frequency: 50 Hz
142,0 m3/h @ 27 Pa
Sound power level at the optimal operating
point
Sound pressure level at free air flow,
measured in rubber bands
4
Environment
4.1
General
Min. permitted ambient temperature TU min.
Max. permitted ambient temperature TU max.
Min. permitted storage temperature TL min.
Max. permitted storage temperature TL max.
4.2
Nominal voltage: 115 V
5,5 bel(A)
43,0 dB(A)
-20 °C
75 °C
-40 °C
80 °C
Climatic Requirements*)
IP-protection type (certified)
Humidity requirements
IP 65 (for fan only, not for connector if applicable) **)
humid temperature, cyclic; according to DIN EN
60068-2-38, 10 cycle and condensation water
check; according to DIN EN ISO 6270-2, 14 days
Salt fog requirements
salt fog, cyclic, in operation; according to DIN EN
60068-2-52, 3 cycle
*) Permittet application area:
The product is for the use in open and unsheltered areas. Direct exposure to water as well as saline ambient
conditions are allowed provided that this does not prevent the normal operation.
Pollution degree 3 (according DIN EN 60664-1)
It occurs conductive pollution or dry non-conductive pollution which becomes conductive due to condensation.
**) The specification of the IP protection refers to the conditions mentioned in certification of the fan. The above
mentioned short description of the protection scope is not final. For detailed information of the respective protection
scope and definitions, see certification as well as DIN EN 60529 (protection by housings) and ISO 20653 (for vehicles)
with the letter K.
8/17/2015
page 8 of 10
Product Data Sheet ACi 4410 HHU
5
Safety
5.1
Electrical Safety
A verification of thermal conditions (normal and abnormal operation) as well as the protection against electric shock,
ingress of solid foreign objects and water has to be done in conjuction with the appliance.
Test voltage HV type test
Unit test voltage
Time type test HV
Insulation resistance
Protection class
5.2
CE
EAC
UL
VDE
CSA
CCC
3000 V
VAC
1s
RI > 10 MOhm
built-in fan
Approval Tests
EC Declaration of Conformity
Eurasian Conformity
Underwriters Laboratories
Association for Electrical, Electronic and
Information Technologies
Canadian Standards Association
China Compulsory Certification
6
Reliability
6.1
General
Life expectancy L10 at TU = 40 °C
Life expectancy L10 at TU max.
Life expectancy L10 Delta (40 °C)
Life expectancy L10 acc. to IPC 9591 at TU = 40 °C
Yes
Yes
Yes / UL507, Electric Fans
Yes / Approval acc. to EN 60950 (VDE 0805) - Information
technology equipment
Yes / C22.2 No. 113 Fans and Ventilators
Yes / GB 12350 Safety Requirements for small Power Motors
65.000 h
30.000 h
130.000 h
110.000 h
8/17/2015
page 9 of 10
Similar pages