Product Data Sheet ACi 4410 HHU Product Data Sheet ACi 4410 HHU ACi 4410 HHU INDEX 1 General ...................................................................................................................................................................... 3 2 Mechanics ................................................................................................................................................................. 3 2.1 2.2 3 Operating Data .......................................................................................................................................................... 5 3.1 3.2 3.3 3.4 3.5 3.6 4 General .............................................................................................................................................................. 8 Climatic Requirements*) .................................................................................................................................... 8 Safety ......................................................................................................................................................................... 9 5.1 5.2 6 Operating Data - Electrical Interface - Input ...................................................................................................... 5 Electrical Operating Data ................................................................................................................................... 5 Operating Data - Electrical Interface - Output ................................................................................................... 5 Electrical Features ............................................................................................................................................. 6 Aerodynamics .................................................................................................................................................... 7 Sound Data ........................................................................................................................................................ 8 Environment .............................................................................................................................................................. 8 4.1 4.2 5 General .............................................................................................................................................................. 3 Connections ....................................................................................................................................................... 4 Electrical Safety ................................................................................................................................................. 9 Approval Tests ................................................................................................................................................... 9 Reliability ................................................................................................................................................................... 9 6.1 General .............................................................................................................................................................. 9 8/17/2015 page 2 of 10 Product Data Sheet ACi 4410 HHU 1 General Fan type Rotating direction looking at rotor Airflow direction Bearing system Mounting position 2 Mechanics 2.1 General Width Height Depth Diameter Mass Housing material Impeller material Max. torque when mounted across both mounting flanges Screw size Fan Clockwise Air outlet over struts Ball bearing Any 120,0 mm 120,0 mm 38,0 mm 0,0 mm 0,275 kg Plastic Plastic wire outlet corner: 50 Ncm remaining corners: 80 Ncm ISO 4762 - M4 degreased, without an additional brace and without washer 8/17/2015 page 3 of 10 Product Data Sheet ACi 4410 HHU 2.2 Connections Electrical connection Lead wire length Cable L = 310 mm +- 20 mm Tolerance See drawing Tube length Tolerance Wire size (AWG) Wire 1 Wire 2 20 Colour brown black Operation L N 8/17/2015 page 4 of 10 Product Data Sheet ACi 4410 HHU 3 Operating Data 3.1 Operating Data - Electrical Interface - Input External voltage supply for input and output signals must be SELV conform. 3.2 Electrical Operating Data Measurement conditions: ∆p = 0: I: Features Voltage range Nominal voltage Frequency Power consumption Tolerance Speed Tolerance 3.3 Normal air density = 1,2 kg/m3; Temperature 23°C +/- 3°C; Motor axis horizontal;warm-up time before measuring 5 minutes (unless otherwise specified).In the intake and outlet area should not be any solid obstruction within 0,5 m. corresp. to free air flow (see section 3.5) corresp. to arithm. mean current value Condition Symbol Values ∆p = 0 U ∆p = 0 UN 115 V ∆p = 0 f 50 Hz 4,4 W ∆p = 0 P +- 20,0 % ∆p = 0 3.300 1/min +- 10,0 % n Operating Data - Electrical Interface - Output External voltage supply for input and output signals must be SELV conform. Tacho type None Alarm type None 8/17/2015 page 5 of 10 Product Data Sheet ACi 4410 HHU 3.4 Electrical Features Electronic function Locked rotor protection Speed-Controlled Auto restart 8/17/2015 page 6 of 10 Product Data Sheet ACi 4410 HHU 3.5 Aerodynamics Measurement conditions: Measured with a double chamber intake rig acc. to DIN EN ISO 5801. Normal air density = 1,2 kg/m3; Temperature 23°C +/- 3°C; In the intake and outlet area should not be any solid obstruction within 0,5 m. The information is only valid under the specified test conditions and may be changed by the installation conditions. If there are deviations from the standard test conditions, the characteristic values must be checked under the installed conditions. a) Operation condition: 3.300 1/min at free air flow Frequency: 50 Hz Max. free-air flow (∆p = 0 / = max.) Max. static pressure (∆p = max. / =0) Nominal voltage: 115 V 175,0 m3/h 78 Pa 8/17/2015 page 7 of 10 Product Data Sheet ACi 4410 HHU 3.6 Sound Data Measurement conditions: Sound pressure level: 1 Meter distance between microphone and the air intake. Sound power level: Acc. to DIN 45635 part 38 (ISO 10302) Measured in a semianchoic chamber with a background noise level of Lp(A) < 5 dB(A) For further measurement conditions see section 3.4 a) Operation condition: 3.300 1/min at free air flow Optimal operating point Frequency: 50 Hz 142,0 m3/h @ 27 Pa Sound power level at the optimal operating point Sound pressure level at free air flow, measured in rubber bands 4 Environment 4.1 General Min. permitted ambient temperature TU min. Max. permitted ambient temperature TU max. Min. permitted storage temperature TL min. Max. permitted storage temperature TL max. 4.2 Nominal voltage: 115 V 5,5 bel(A) 43,0 dB(A) -20 °C 75 °C -40 °C 80 °C Climatic Requirements*) IP-protection type (certified) Humidity requirements IP 65 (for fan only, not for connector if applicable) **) humid temperature, cyclic; according to DIN EN 60068-2-38, 10 cycle and condensation water check; according to DIN EN ISO 6270-2, 14 days Salt fog requirements salt fog, cyclic, in operation; according to DIN EN 60068-2-52, 3 cycle *) Permittet application area: The product is for the use in open and unsheltered areas. Direct exposure to water as well as saline ambient conditions are allowed provided that this does not prevent the normal operation. Pollution degree 3 (according DIN EN 60664-1) It occurs conductive pollution or dry non-conductive pollution which becomes conductive due to condensation. **) The specification of the IP protection refers to the conditions mentioned in certification of the fan. The above mentioned short description of the protection scope is not final. For detailed information of the respective protection scope and definitions, see certification as well as DIN EN 60529 (protection by housings) and ISO 20653 (for vehicles) with the letter K. 8/17/2015 page 8 of 10 Product Data Sheet ACi 4410 HHU 5 Safety 5.1 Electrical Safety A verification of thermal conditions (normal and abnormal operation) as well as the protection against electric shock, ingress of solid foreign objects and water has to be done in conjuction with the appliance. Test voltage HV type test Unit test voltage Time type test HV Insulation resistance Protection class 5.2 CE EAC UL VDE CSA CCC 3000 V VAC 1s RI > 10 MOhm built-in fan Approval Tests EC Declaration of Conformity Eurasian Conformity Underwriters Laboratories Association for Electrical, Electronic and Information Technologies Canadian Standards Association China Compulsory Certification 6 Reliability 6.1 General Life expectancy L10 at TU = 40 °C Life expectancy L10 at TU max. Life expectancy L10 Delta (40 °C) Life expectancy L10 acc. to IPC 9591 at TU = 40 °C Yes Yes Yes / UL507, Electric Fans Yes / Approval acc. to EN 60950 (VDE 0805) - Information technology equipment Yes / C22.2 No. 113 Fans and Ventilators Yes / GB 12350 Safety Requirements for small Power Motors 65.000 h 30.000 h 130.000 h 110.000 h 8/17/2015 page 9 of 10