DELTA P/N : MPT136-H1 Series Mechanical dimensions Unit : mm A’ 13.45 ± 0.35 A 12.6 ± 0.2 B 5.8 ± 0.2 C 2.0 ± 0.5 C’ 2.5 ± 0.1 D 5.0 ± 0.5 D’ 6.0 ± 0.2 E 0~0.15 F 5.5 G 8.0 H 14.5 Electrical Characteristics DCR Lo @0A (uH) ± 20% Ir(Adc) MPT136-8R2H1 8.2 11.0 MPT136-100H1 10.0 MPT136-120H1 Part No. (mΩ) Isat(Adc) TYP. MAX 13.5 13.6 16.0 10.0 12.5 18.0 20.7 12.0 7.0 10.0 20.0 23.0 MPT136-150H1 15.0 6.0 9.0 25.0 29.0 MPT136-180H1 18.0 5.0 8.0 30.0 35.0 MPT136-220H1 22.0 5.0 7.5 34.0 39.5 MPT136-270H1 27.0 4.0 6.5 49.0 56.0 MPT136-330H1 33.0 4.0 6.0 65.0 75.0 MPT136-470H1 47.0 3.5 5.5 80.0 90.0 MPT136-680H1 68.0 3.0 4.5 120.0 140.0 MPT136-101H1 100.0 2.5 3.5 180.0 200.0 MPT136-121H1 120.0 2.3 3.2 210.0 235.0 MPT136-151H1 150.0 2.0 2.7 300.0 350.0 NOTES: (1) All test data is referenced to 25℃ ambient. (2) Ir is the DC current which cause the surface temperature of the part increse approximate 40℃ (3) Isat is the DC current which cause the inductance drop approximate 30% of Lo. (4) Operating temperature range -55℃ to 125℃. (The part temperature should be keepped under 125℃ when the worse operating condition apply on it. Circuit design, component placement, PWB tracesize and thickness, airflow and other cooling provision may affect the part temperature. Part temperature should be verified in the end application.) (5) The rated current is depended on Ir and Isat which one is lower.