Embedded Power for Business-Critical Continuity Rev.03.21.13_185 NPS60-M Series 1 of 3 NPS60-M Series 60 Watts Total Power: Input Voltage: # of Outputs: 60 Watts 90 - 264 VAC 127 - 300 VDC Single Special Features • Medical and ITE Safety Approvals • Universal input • Less than 1U high • 2” x 4” footprint • Remote sense • Overload and short circuit protection • Adjustable output voltage • High efficiency • High MTBF • Built in EMI filter (CISPR 22 Class B) • International Efficiency Level V, Energy Star 2.0 & CeC compliant (except NPS62-M) • Less than 300 mW no-load power consumption • 0˚C to +80˚C operation • Input power < 74 watts • Complies with EN61000 -3-2 • UL Class I approved • Class II approved (with Class A EMI) • LPX50 enclosure kit available • Dual AC fuses Safety • TUV: 60950, 60601-1 • UL: 60950, 60601-1 • CSA: 60950, 60601-1 • NEMKO: 60950, 60601-1 • CB: Certificate and report • CE: Mark (LVD) • CCC: Mark Electrical Specifications Input Input range: 90 - 264 VAC (wide range) 127-300 Vdc Frequency: 47 - 63 Hz Inrush current: < 50 A peak @ 230 VAC, cold start @ 25° C Input power: < 74 Watts Efficiency: EMI/RFI: 87% average (as per Energy Star 2.0 standard) (NPS62-M, 80%) Safety ground leakage current: FCC Class B conducted; CISPR 22 Class B conducted; EN55022 Class B conducted, VDE0878PT3 Class B conducted 275uA @ 50/60 Hz; 264 VAC input Output Maximum power: Adjustment range: 60 W for convection ± 20% minimum Hold-up time: Overload protection: 10/20 ms 115/230 VAC input line Short circuit protection on all outputs. Case overload protected @ 110-180% of normal rating Overvoltage protection: 30-50% above nominal output Remote sense: Compensated for 0.5 V lead drop max. Will operate without remote sense connected. Reverse connection protected. Embedded Power for Business-Critical Continuity Rev.03.21.13_185 NPS60-M Series 2 of 3 Environmental Specifications Operating temperature: Storage temperature: Electromagnetic susceptibility: 0° to 50 °C ambient derate each output at 2.5% per degree from 50° to 80 °C. -20 °C start up -45 °C to +85 °C Designed to meet EN61000-4; -2, -3, -4, -5, -6, -8, -11 Level 3 Humidity: Operating; non-condensing 10% to 90% RH Vibration: IEC68-2-6 to the levels of IEC721-3-2 MTBF demonstrated: > 550,000 hours at full load and 25 °C ambient conditions Mechanical Drawing BARCODE SERIAL LABEL M1 GND TAB (CN1) SK2 SK1 1.72" (43.8) PIN 1 PIN 1 PIN 6 PIN 3 INPUT CONNECTOR (SK1) MODEL LABEL ROHS LABEL M2 6 PIN OUTPUT CONNECTOR (SK2) 1.26" (32.1) 0.16” (4.0) MOUNTING HOLE (4 PLACES) 2.00" (50.8) VR1 OUTPUT VOLTAGE ADJUST POT 4.00" (101.6) 3.73" (94.6) 0.197” (5.0) MINIMUM STANDOFF HEIGHT 1.12" (28.5) Embedded Power for Business-Critical Continuity Ordering Information Americas Rev.03.21.13_185 NPS60-M Series 3 of 3 Model Number Output Voltage Minimum Load Maximum Load with Convection Cooling Peak Load1 Regulation Ripple P/P (PARD)3 NPS62-M 5V 0A 11 A 13 A ± 2% 50 mV NPS63-M 12 V 0A 5A 5.5 A ± 2% 120 mV 5810 Van Allen Way Carlsbad, CA 92008 USA Telephone: +1 760 930 4600 Facsimile: +1 760 930 0698 NPS64-M 15 V 0A 4A 4.4 A ± 2% 150 mV Europe (UK) NPS65-M 24 V 0A 2.5 A 2.75 A ± 2% 240 mV 2 1. Peak current lasting < 15 seconds with a maximum 10% duty cycle. 2. At 25 °C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings. 3. Peak-to-peak with 20 MHz bandwidth and 10 µF (tantalum capacitor) in parallel with a 0.1 µF capacitor at rated line voltage and load ranges. Asia (HK) Pin Assignments Connector SK1-1 SK1-3 CN1 SK2-1 SK2-2 SK2-3 SK2-4 SK2-5 SK2-6 Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX United Kingdom Telephone: +44 (0) 1384 842 211 Facsimile: +44 (0) 1384 843 355 NPS62-M NPS63-M NPS64-M NPS65-M Line Neutral Ground +5 V +5 V Common Common -Sense +Sense Line Neutral Ground +12 V +12 V Common Common -Sense +Sense Line Neutral Ground +15 V +15 V Common Common -Sense +Sense Line Neutral Ground +24 V +24 V Common Common -Sense +Sense Mating Connectors AC Input: Molex 09-50-8031 (USA) 09-93-0300 (UK) PINS: 08-52-0113 DC Outputs: Molex 09-50-8061 (USA) 09-93-0600 (UK) PINS: 08-52-0113 Emerson Network Power Connector Kit #70-841-006, includes all of the above Notes: 1. Specifications subject to change without notice 2. All dimensions in inches (mm), tolerance is ±0.02” (±0.5mm) 3. Mounting holes M1 and M2 should be grounded for EMI purposes 4. Mounting hole M1 is safety ground connection 5. Specifications are for convection rating at factory settings at 115 VAC input, 25 °C unless otherwise stated 6. For DC input an external DC safety rated fuse must be used 7. Warranty: 2 year 8. Weight: 0.26lbs/0.118kg 14/F, Lu Plaza 2 Wing Yip Street Kwun Tong, Kowloon Hong Kong Telephone: +852 2176 3333 Facsimile: +852 2176 3888 For global contact, visit: www.Emerson.com/EmbeddedPower techsupport.embeddedpower @emerson.com While every precaution has been taken to ensure accuracy and completeness in this literature, Emerson Network Power assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. Emerson Network Power. The global leader in enabling business-critical continuity. AC Power Connectivity DC Power Embedded Computing Embedded Power Monitoring Outside Plant Power Switching & Controls Precision Cooling Racks & Integrated Cabinets Services Surge Protection EmersonNetworkPower.com Emerson and the Emerson Network Power logo are trademarks of Emerson Electric Co. ©2012 Emerson Electric Co. All rights reserved. Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Emerson Network Power: NPS64-M