Delta ADP-19V Over-voltage/load/temperature & short circuit protection Datasheet

 TECHNICAL
DATASHEET
ADP Series Power Adapters
19V 40W/65W/90W
ADP 19V
Highlights & Features
–
–
–
–
–
Energy Star Compliance (Level VI)
IT safety approvals
100k Hours MTBF
Over-Voltage/Load/Temperature & Short Circuit protections
Low Leakage Current
Safety Standards
CB Certified for worldwide use
Model Information
ADP Series Power Adapters
Model Number
Input Voltage Range
Output Voltage
Output Current
ADP-40KD BBBM
90-264Vac
19Vdc
2.1A
ADP-65JH HBAN
90-264Vac
19Vdc
3.42A
ADP-90MD HDM
90-264Vac
19Vdc
4.74A
Specifications
Input Ratings / Characteristics
ADP-­‐40KD BBBM ADP-­‐65JH HBAN Nominal Input Voltage
100-240Vac
Input Voltage Range
90-264Vac
Nominal Input Frequency
50-60Hz
Input Frequency Rang
Input Current
47-63Hz
1.2A Max at 100Vac input
voltage
Inrush Current Limit (cold start)
Efficiency at nominal input voltage
85%
84%
>88%
>85.30%
No Load Power Consumption
<0.1W @ 115Vac/60Hz ,
<0.3W @ 230Vac/50Hz
Leakage Current
<100uA at 240Vac/50Hz
1 1.5A Max at 100Vac input voltage
No Damage
Active Mode Efficiency @ 115Vac
Active Mode Efficiency @ 230Vac
ADP-­‐90MD HDM www.DeltaPSU.com (January 2016, Rev. 1.0) >87%
>88%
<0.21W @ 115Vac/60Hz
<50uA at 240Vac/50Hz
<75uA at 240Vac/50Hz
TECHNICAL
DATASHEET
ADP Series Power Adapters
19V 40W/65W/90W
Output Ratings / Characteristics
ADP-­‐40KD BBBM ADP-­‐65JH HBAN Rated Voltage
19V
Voltage Range
18.05 ~ 19.95V
Current
Output Ripple and Noise
Turn On delay time
ADP-­‐90MD HDM 2.1A
3.42A
4.74A
350 mV pk-pk
300mV pk-pk
380mV pk-pk
5 seconds @ 100-240Vac
2 seconds @ 100-240Vac
Hold-up Time
The output voltage shall be sustained 5mS within regulation requirement after loss 100Vac
and maximum load.
Rise Time
DC output rise time from
10% to 90% of output
voltage shall be less than
30mS at nominal line
and maximum load
Transient Load Response
0.1A to 100% load at 2.5A/us slew rate and frequency is
10Hz to 10KHz
DC output rise time from 10% to 90% of output voltage shall be
less than 100ms at nominal line and maximum load
0% to 50% and 50% to 100%
1.0A/us slew rate and frequency
is 100Hz
Environment
ADP-­‐40KD BBBM ADP-­‐65JH HBAN Operating Temperature
ADP-­‐90MD HDM 0 °C to +40 °C
Shipping/Storage Temperature
-30 °C to +80 °C
-20 °C to +85 °C.
Operating Humidity
8% to 90% RH (Non-Condensing)
Shipping/Storage Humidity
5% to 95% RH (Non-Condensing)
Lightning Surge Immunity
IEC-1000-4-5 Level 3
Requirements
L-N 1KV/1.2 * 50uS 5
times No damage
Electric Fast Transients (EFT)
Electrostatic Discharge (ESD)
IEC-61000-4-5 Level 3 requirements
L-N 1KV/1.2 * 50uS 5 times No function error
L-FG 2KV/1.2 * 50uS 5 times No damage.
IEC-1000-4-4/1995
EN 61000-4-4
±15KV air discharge
±8KV contact discharge
Between AC input and
secondary AC 3KV test time
1 minute; 100% of line
products of this Adapter
shall be applied 3000Vac
for 2 seconds between AC
input terminals and output
terminals. Cut off current
10mA.
Dielectric Withstand Voltage (HIPOT)
Between AC input and
secondary AC 3KV test
time 1 minute; 100% of line
products of this Adapter
shall be applied 3000Vac
for 2 seconds between AC
input terminals and output
terminals. Cut off current
3mA.
Insulation Resistance
The insulation resistance shall be not less than 30M ohms
after application of 500Vdc/10mA for 1 minute.
Electromagnetic Interference (EMI)
MTBF
(a) FCC Class B
(b) CISPR 22 Class B
(c) VCCI Class B
150,000 hours
Altitude
2 (a) FCC Class B
(b) CISPR 22 Class B
(c) VCCI Class B
The insulation resistance shall
be not less than 20M ohms after
application of 500Vdc/10mA for
1 minute
(a) FCC Class B
(b) CISPR 22 Class B
(c) VCCI Class B
100,000 hours
5,000m (16,400 ft)
www.DeltaPSU.com (January 2016, Rev. 1.0) 100% of line products of this
Adapter shall be applied
3000Vac for 1 seconds between
AC input terminals and output
terminals. Cut off current is
10mA.
TECHNICAL
DATASHEET
ADP Series Power Adapters
19V 40W/65W/90W
Protections
Over Voltage
Overload / Overcurrent
ADP-­‐40KD BBBM ADP-­‐65JH HBAN ADP-­‐90MD HDM The output shall be protected
to latch off at over-voltage
condition, maximum value
can’t be over 29V.
The output shall be protected
to latch off at over-voltage
condition, maximum value
can’t be over 27V.
The output shall be protected
to latch off at over-voltage
condition, maximum value
shall be more than 22V and
be less than 27V.
The maximum constant
current shall be more than
4.1A. The adapter shall be
Auto-recovery
The minimum constant
current shall be more than
5.214A.
The maximum constant
current shall be less than
6.636A.
The output shall be protected
to latch off at over-current
condition.
The maximum constant
current shall be more than
2.1A and be less than 5.0A
at 90Vac and 264Vac.
The adaptor shall be autorecovery.
Latch Mode
Over Temperature
Auto-Recovery
Short Circuit
Mechanical
ADP-­‐40KD BBBM Color
ADP-­‐65JH HBAN ADP-­‐90MD HDM Black
Outline Dimensions (L x W x D)
89.5 * 37.0 * 26.5 mm
3.52 * 1.45 * 1.04 in
AC Inlet Type
DC Cable Type
108.0 * 46.0 * 29.5 mm
4.25 * 1.81 * 1.16 in
127.0 * 51.0 * 30.5 mm
5.0 * 2.0 * 1.2 in
Socket C6 type
UL 1571 22AWG
DC Cable Length
UL1571 #AWG18
#AWG18
1800 mm
DC Connector - OD
5.5 mm
5.5 mm
5.5 mm
DC Connector - ID
2.5 mm
2.5 mm
1.7 mm
DC Connector - Length
12.5 mm
11 mm
11 mm
3 www.DeltaPSU.com (January 2016, Rev. 1.0) TECHNICAL
DATASHEET
ADP Series Power Adapters
19V 40W/65W/90W
Mechanical
ADP-40KD BBM
ADP-65JH HBAN
4 www.DeltaPSU.com (January 2016, Rev. 1.0) TECHNICAL
DATASHEET
ADP Series Power Adapters
19V 40W/65W/90W
ADP-90MD HDM
5 www.DeltaPSU.com (January 2016, Rev. 1.0) 